Hunter Fan 50816 Owner's manual

Type
Owner's manual
www.ventiladoreshunter.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
ENGLISH
Important Instructions: Keep Instructions for future use
1
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
PAG E
5
30 inches
7 feet
PAG E
2
What to Expect with
Your Installation
Ceiling Bracket
Ladder
PAG E
3
Tools Needed
Table of Contents
Mounting Options
PAG E
10
PAG E
6
Wiring Canopy
PAG E
7
Downrod
PAG E
16
Wall Control
Preparation
PAG E
11
PAG E
19
Maintenance &
Cleaning
Troubleshooting
?
?
?
PAG E
20
Warranty Statement
PAG E
18
PAG E
14
Light Kit
PAG E
13
Switch Housing
Blades
PAG E
12
PAG E
4
Congratulations on purchasing your new Hunter®
ceiling fan! It will provide comfort and performance
in your home or ofce for many years. This installation
and operation manual contains complete instructions
for installing and operating your fan.
We are proud of our work and appreciate the
opportunity to supply you with the best ceiling fan
available anywhere in the world.
www.hunterfan.com.br
2
MD510-01 • 09/30/14 • © Hunter Fan Company
What to Expect with Your Installation
w.1 - To reduce the risk of re, electrical shock, or personal injury,
mount fan directly from building structure and/or an outlet
box marked acceptable for fan support of 31.8 kg and use the
mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the circuit
breakers to the outlet box and associated wall switch location. If
you cannot lock the circuit breakers in the off position, securely
fasten a prominent warning device, such as a tag, to the service
panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades, or
cleaning the fan. Do not insert foreign objects in between rotating fan
blades.
w.5 - This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
people with a lack of experience and knowledge, unless they have
received instructions regarding the use of the device or under the
supervision of a person responsible for their safety.
w.6 - It is recommended that children be supervised to ensure that
they are not using the appliance improperly
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualied electrician.
c.2 - Use only Hunter replacement parts.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
0,76 meters
from blade tip to
nearest wall or
obstruction
2,3 meters
from bottom
edge of blade to
the oor
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
Must be able to
secure the fan to
building structure or
fan-rated outlet box.
Do not use a plastic
outlet box.
Select a downrod length
1
2
3
Standard Downrod
for ceilings 2,4 -3 meters high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 3 meters or higher
Use ONLY Hunter
Ceiling Fan branded
accessory light kits.
www.hunterfan.com.br
Tools Needed
Ladder
Pliers Wire Strippers
Screwdrivers
Power Drill
(optional)
3.5 mm Drill
Bit (optional)
8 mm Drill Bit
(optional)
If mounting to a support structure, you
will also need these tools.
Hammer
(optional)
3
MD510-01 • 09/30/14 • © Hunter Fan Company
4
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Hang your fan by a standard downrod
(included) or use a shorter downrod (sold
separately) for Low-Prole Mounting.
Mounting Options
Note: Do not hang the fan from a
ceiling that is angled greater than 34°
Support
Structure
Ceiling
Outlet Box
(required)
Angled
Mounting
Style
Standard
Mounting
Style
Support
Structure
Ceiling
Outlet Box
(required)
Carefully choose the installation location
that allows for optimal air ow.
The support structure must be able to support 5
times the weight of the fan. The weight of the fan is
located on the product packaging.
You will need a longer downrod (sold
separately) to hang the fan from a
vaulted or angled ceiling.
If you have a at ceiling: If you have an angled ceiling:
5
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Ceiling Bracket
Refer to warning w.1 on pg. 2
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
Make sure all four (4) bumpers
are still attached.
For angled ceilings, point
opening toward peak.
Use wood screws
(included) when securing
to support structure with
approved electrical outlet
box. Drill 3.5 mm pilot
holes in support structure
to aid in securing ceiling
bracket with hardware
found in the hardware
bag.
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg or less.
OFF
Turn Power
Note: Do not mount ceiling fan
to a plastic outlet box.
Use concrete anchors (included)
when securing to support structure
with approved outlet box in a concrete
ceiling. Drill 8 mm pilot holes in
support structure. Hammer the M6
expansion anchors into the holes until
the ends are ush with the ceiling.
Install the washer, isolator, and nut
found in the hardware bag to
the expansion anchors.
www.hunterfan.com.br
Ceiling Bracket (continued)
Preparation
D
I
S
C
A
R
D
K
E
E
P
!
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
Time Saver Tip: Get a helper
to insert grommets, found in the
hardware bag, into the blades
while you’re doing the next
couple of steps.
6
MD510-01 • 09/30/14 • © Hunter Fan Company
7
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Downrod
S lide
S lide
1 2 3 4 5
678910
Sold Separately
Longer
Downrod
for angled
ceilings or
ceilings 3 m or
higher
Shorter
Downrod
for fans installed
close to ceiling
Standard
Downrod
for ceilings 2,4-3 m
high
Option 1Option 2
Option 3
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Steps 6-10 to reassemble with new pipe
Included
(pre-assembled)
Sold Separately
8
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
20 cm
1 cm
C
U
T
&
S
T
R
I
P
(not to scale)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
The wires can be cut,
but leave at least 20 cm
extending from the top of
the downrod.
Downrod (continued)
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
If the setscrew is not tightened
securely, the fan may fall.
K
E
E
P
!
20 cm 1 cm
9
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Downrod (continued)
DO NOT PICK THE FAN UP BY THE CANOPY
OR WIRES. Place the downrod ball into the slot
in the ceiling bracket.
Put the wires and downrod through the canopy.
Let the canopy sit loosely on top of the fan.
10
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Wiring
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
F
R
O
M
F
A
N
F
R
O
M
C
E
I
L
I
N
G
B
R
A
C
K
E
T
F
R
O
M
F
A
N
Using an orange wire
connector from the
hardware bag, connect
the 3 grounding wires
(green, green/yellow
stripe, or bare copper)
coming from the ceiling,
downrod, and hanging
bracket.
(Grounding)
Green/Yellow
Stripe
Green/Yellow
Stripe
Blue
Brown
(Grounded)
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
Using the orange wire
connectors from the
hardware bag, connect the
brown wire (ungrounded)
from the ceiling to the
brown and the black with
white stripe wires from the
fan. Connect the blue wire
(grounded) from the ceiling to
the blue wire from the fan.
Using the orange wire
connectors from the
hardware bag, connect the
blue wire (grounded) from
the ceiling to the blue wire
from the fan.
Connect the brown wire
(ungrounded) from the
ceiling to the brown wire
from the fan. Connect the
second (ungrounded)
wire from the ceiling to
the black with white stripe
wire from the fan.
F
R
O
M
F
A
N
Blue
(Ungrounded)
Brown
Black with white stripe
(Grounded)
F
R
O
M
C
E
I
L
I
N
G
(Ungrounded)
For Dual Switches
For a Single Switch
F
R
O
M
C
E
I
L
I
N
G
F
R
O
M
C
E
I
L
I
N
G
Bl
a
c
k
w
i
t
h
White Stripe
(Ungrounded)
11
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Canopy
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Screw
Holes
Insert the two canopy screws
found in the hardware bag.
Note: Fan style may vary.
12
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Blades
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the nishes.
12
Lightly attach the blade irons to the
motor with screws found in the
hardware bag, then securely tighten
after both screws are attached.
Install the grommets, found in the hardware
bag, in the blades by hand. Place each blade
between a blade iron and medallion. Install
three blade screws, found in the hardware
bag, to attach the medallion to the blade
iron. Repeat for all blades.
13
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Screw two housing assembly screws from
the hardware bag halfway into the
motor housing. It does not matter which
two screw holes you choose.
Insert the third screw, found in the
hardware bag, into place and then tighten
all three screws.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing xture falling.
Switch Housing
14
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Install three housing screws, found in
the hardware bag. Tighten all three
screws securely.
Light Kit
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the light xture falling.
Connect the plugs from the upper and
lower switch housings. Make sure to line up
the colored markings on the connectors.
Place the light kit over the upper switch
housing and align the screw holes.
15
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Light Kit (continued)
Note: Globe style and number of
lights may vary.
Lift the globe and align the notches in the
globe with the tabs in the light kit. Attach
the glass bowl to the light kit by twisting it
clockwise until it snaps into place.
Tab
Bulb
Notch
CONGRATULATIONS!
YOU’RE DONE!
Install a 14W CFL bulb (sold separately) into
each of the E27 sockets. When necessary,
replace with bulbs of same wattage.
16
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Press the rotary switch terminal
into the hole in the faceplate as
shown with screw terminals facing
away from the light switch. Install
the knob onto the switch after it is
pressed into the faceplate.
Attach a jumper wire (not included)
from terminal 2 of the rotary switch to
the center terminal of the rocker switch.
Tighten the set screws.
Connect the wires from the capacitor
to the rotary switch terminal as
follows:
Grey from the capacitor to
terminal 3. Tighten the set
screw.
Brown from the capacitor to
terminal 1 . Tighten the set
screw.
Green from the capacitor to
terminal 4. Tighten the set
screw.
To install the wall control, you must
first remove the faceplate and switch
assembly from the existing wall control,
if you have one.
Save the screws you removed from
the faceplate to use with the new
included faceplate.
Wall Control
4
1
2
3
Rotary Switch
Terminal
Rotary Switch
Terminal
Capacitor
Knob
4
1
2
3
Rotary Switch
Terminal
Rocker
Switch
Note: A power disconnect switch should be
installed in conjunction with the wall control.
17
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
Wall Control (continued)
The light switch turns the light on and off.
The fan control controls the speed of the fan
as follows:
High Speed
Medium Speed
Low Speed
Fan Off
3
2
1
0
Be sure no bare wire is exposed at the
connection points. Attach the faceplate
assembly to the wall box using the two screws
you saved from the original faceplate intalled
with your wall switch.Press the faceplate onto
the faceplate assembly.
Faceplate
Faceplate
Assembly
Connect the wire for the fan to the rotary
switch terminal 3. Tighten the set screw.
Connect the wire to the light to the
rocker switch top terminal. Tighten the
set screw.
Connect the wire from the supply main to
the rocker switch center terminal. Tighten
the set screw.
Fan Wire
Supply Main
Light Wire
Rocker Switch
Terminal
4
1
2
3
Note: The rocker switch terminal may have
an additional bottom terminal that will not
be used.
ON
Turn Power
18
www.hunterfan.com.br
MD510-01 • 09/30/14 • © Hunter Fan Company
For cleaning the fan, use soft brushes or
cloths to prevent scratching. Cleaning
products may damage the nishes.
Maintenance & Cleaning
Reverse
Switch
To switch the direction of air ow, move
the reverse switch to the opposite
position. You will need to remove the
light kit glass to do so.
Press the Fan Off button for at
least three seconds to initiate the
Safe-Exit Mode.
The lights will ash for visual
conrmation.
The lights will stay on 50%
brightness for 15 seconds and
then begin to dim. After a total
of 30 seconds, the lights will be
completely off.
Note: For CFL lighting, the lights
will stay on 100% brightness for 30
seconds. After a total of 30 seconds,
the lights will be completely off.
The Safe-Exit Program gives
you about thirty seconds of light
when you turn the lights off to
exit the room before the lights go
out. To use Safe-Exit:
Safe-Exit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Hunter Fan 50816 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI