Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Pack Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Removing the Compressor Safety Band (G592/G593/G594/G595/U629/U630 only) . . . . . . 1
Fitting the Waste Water Tray (G592/G593/G594/G595/U629/U630 only) . . . . . . . . . . . . . . 1
Fitting the Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Storing Food . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Turn On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Lock/Unlock the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Enter the Parameter Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Manual Defrost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Lock/Unlock the Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cleaning, Care & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cleaning the Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1
UK
Safety Tips
Position on a flat, stable surface.
A service agent/qualified technician should carry out installation and any
repairs if required. Do not remove any components or service panels on
this product.
Consult Local and National Standards to comply with the following:
• Health and Safety at Work Legislation
• BS EN Codes of Practice
• Fire Precautions
• IEE Wiring Regulations
• Building Regulations
DO NOT use jet/pressure washers to clean the appliance.
DO NOT use the appliance outside.
DO NOT use this appliance to store medical supplies.
DO NOT use electrical appliances inside the appliance (e.g. heaters, ice-
cream makers etc.)
DO NOT stand or support yourself on the base, drawers or doors.
DO NOT allow oil or fat to come into contact with the plastic
components or door seal. Clean immediately if contact occurs.
Bottles that contain a high percentage of alcohol must be sealed and
placed vertically in the refrigerator.
Always carry, store and handle the appliance in a vertical position and
move by holding the base of the appliance.
Always switch off and disconnect the power supply to the unit before
cleaning.
Keep all packaging away from children. Dispose of the packaging in
accordance with the regulations of local authorities.
If the power cord is damaged, it must be replaced by a POLAR agent or
a recommended qualified technician in order to avoid a hazard.
Product Description
G590 - 400 litre Single Door Stainless Steel Refrigerator
G591 - 400 litre Single Door Stainless Steel Freezer
G592 - 600 litre Single Door Stainless Steel Refrigerator
G593 - 600 litre Single Door Stainless Steel Freezer
G594 - 1200 litre Double Door Stainless Steel Refrigerator
G595 - 1200 litre Double Door Stainless Steel Freezer
U629 - 600 litre Single Glass Door Refrigerator
U630 - 1200 litre Double Glass Door Refrigerator
Introduction
Please take a few moments to carefully read through this manual. Correct
maintenance and operation of this machine will provide the best possible
performance from your POLAR product.
Pack Contents
The following is included:
POLAR prides itself on quality and service, ensuring that at the time of
packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR
dealer immediately.
Installation
1. Remove the appliance from the packaging. Make sure that all protective
plastic film and coatings are thoroughly removed from all surfaces.
2. Maintain a distance of 20cm (7 inches) between the unit and walls or
other objects for ventilation. Increase this distance if the obstacle is a
heat source.
3. Level the appliance by adjusting the screw feet.
Removing the Compressor Safety Band
(G592/G593/G594/G595/U629/U630 only)
The compressor is located on the top of the appliance, and sits on rubber
washers. Under normal operating conditions the compressor is allowed to
vibrate.
To avoid damage through excessive motion during transit, a stainless steel
safety band is placed over the compressor and screwed into the top of the
appliance.
This safety band and the two screws fixing it to the appliance must be
removed before the appliance is turned on.
Fitting the Waste Water Tray
(G592/G593/G594/G595/U629/U630 only)
The waste water tray and supports comes ready to fit to the underside of the
appliance.
1. Carefully tip the appliance to gain access to the underside.
2. Screw the supports into the holes on the underside of the appliance,
using the screws and washers provided.
3. Lower the appliance and slide the tray onto the supports.
Note: If the unit has been stored in a non-vertical position,
stand it in an upright position for approximately 12 hours
before operation.
Note: Before using the appliance for the first time, clean the
internal cabinet and shelves with soapy water.
Compressor
Safety Band
Screws
Compressor
POLAR Refrigerator or Freezer
•Keys x 2
Shelf guides x 8 (Single)/
x 16 (Double)
Shelves x 4 (Single)/
x 8 (Double)
Instruction manual
Waste water tray
Waste water tray supports x 2
•Screws x 6
•Washers x 6
Spring washers x 6
2
UK
Fitting the Shelves
1. Place one set of shelf guides on either side of the cabinet at the desired
height.
2. Slide the shelf into place.
3. Repeat for the remaining shelves.
Operation
Storing Food
To get the best results from your POLAR appliance, follow these instructions:
Only store foodstuffs in the appliance when it has reached the correct
operating temperature.
Do not place uncovered hot food or liquid inside the appliance.
Wrap or cover food where possible.
Do not obstruct the fans inside the appliance.
Avoid opening the doors for prolonged periods of time.
Turn On
1. Close the door(s) of the appliance.
2. Ensure the power switch is set to [O] and turn on at the socket.
3. Switch on the Power [I]. The current temperature within the appliance
is displayed.
Control Panel
Lock/Unlock the Control Panel
To lock the control panel:
1. Press and hold the UP and DOWN
buttons simultaneously for 10
seconds.
2. Pof flashes on the display and the keyboard is locked.
To unlock the control panel:
1. Press and hold the UP and DOWN
buttons simultaneously for 10
seconds.
2. Pon flashes on the display and the keyboard is unlocked.
Enter the Parameter Menu
1. Unlock the control panel, if locked.
2. Press and hold the SET
button until ‘d1’ flashes on the display.
3. Press the SET
button repeatedly to scroll to the desired parameter
(see below).
.
Note: Always place one shelf in the lowest available position,
or if that position is higher than 40mm, place the shelf
directly onto the floor of the cabinet without the guides.
This is vital for ensuring correct drainage of condensation.
Note:
If a button is not pressed for 10 seconds while using the
control panel it times out and reverts to standby mode.
When parameters are being set the Setpoint LED will flash on
the display.
Pon
Parameter Name Description Range
d1 Operating temperature Set the operating temperature of the appliance -2°C to 10°C
d2
Temperature
Differential
The Temperature Differential is the allowed temperature difference above and below the
operating temperature before the compressor starts/cuts off
0 to 20°C
d3
Temperature Range
Set the minimum (d3) and maximum (d4) temperatures that the appliance can fluctuate
between
-40°C
d4 95°C
d5
Compressor Activation
Time Intervals
Enter the minimum time interval between the compressor turning off after turning on. 0-999 seconds
d6
Maximum Temperature
Differential Alarm
Set an alarm to sound if the temperature inside the appliance exceeds the set operating
temperature by a specified amount
0°C-50°C
d7
Temperature
Differential Alarm Delay
Set a delay before the temperature differential alarm is triggered 0-99 minutes
d8
Defrost Cycle Time
Intervals
Set the time between each defrost cycle 1-999 hours
d9
Maximum Defrost
Duration
Set the maximum length of the defrost cycle
Note: The defrost duration can be overridden by parameter d10 (below), if the
cut-off temperature is reached before the end of the defrost duration
0-999 minutes
d10
Defrost Cut-off
Temperature
(G591/G593/G595 only) Set the defrost cut-off temperature -45°C to 50°C
d11
Additional Cut-off
Defrost Period
(G591/G593/G595 only) Set an additional amount of defrost time after the defrost cut-off
point has been reached (if required)
0-99 minutes
d12
Delayed Actual
Temperature Display
Set the length of time the inner temperature of the appliance (before defrost started) is
displayed for after a defrost cycle has finished
0-99 minutes
d13
Compressor On/Off
During Defrost
(G591/G593/G595 only) Turn the Compressor On or Off during the defrost cycle On (1) or Off (0)
d14 Evaporator Drying Time
Set the amount of time the compressor remains turned Off after a defrost cycle, reducing the
amount of frost build up
0-99 minutes
3
UK
Manual Defrost
The appliance will automatically run a defrost cycle every six hours.
To manually defrost the appliance:
1. Press and hold the DEFROST button for 5 seconds.
2. The defrost cycle will start immediately and the Defrost LED illuminates.
The defrost will last a maximum of 30 minutes.
3. Waste water is collected in the waste water tray.
Lock/Unlock the Doors
A lock is fitted to the doors to ensure foodstuffs are kept secure within your
POLAR appliance.
Use the keys provided to lock/unlock the doors.
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the interior of the appliance as often as possible.
Do not use abrasive cleaning agents. These can leave harmful residues.
Clean the door seal with water only.
Always wipe dry after cleaning.
Do not allow water used in cleaning to run through the drain hole into
the evaporation pan.
Take care when cleaning the rear of the appliance. Sharp edges can cut.
A POLAR agent or qualified technician must carry out repairs if required.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance.
POLAR recommend that a POLAR agent or qualified technician clean the
condenser.
Troubleshooting
If your POLAR appliance develops a fault, please check the following table
before making a call to the Helpline.
Parameter Name Description Range
=19 Temperature Offset
Should there be any variance between measured and actual temperature, the measured
temperature can be offset to compensate
-20°C to 20°C
=22 Unit of Measurement Set whether the temperature is displayed in Centigrade or Fahrenheit Centigrade (0) or Fahrenheit (1)
=23
Compressor Operation
During Probe Failure
Set whether the compressor runs or remains Off during a temperature probe failure
Compressor runs (1)
Remains Off until fault fixed (0)
Runs intermittently with
parameters =24 and =25 (2)
=24
Compressor ‘On’
Duration
Set the length of time the compressor runs during a temperature probe failure 1-99 minutes
=25
Compressor ‘Off’
Duration
Set the length of time the compressor remains Off during a temperature probe failure 1-99 minutes
=34
Initial Defrost After
Startup
(G591/G593/G595 only) Set whether the appliance starts a defrost cycle 10 minutes after
startup or after the time programmed in parameter d8 (Defrost Cycle Time Intervals)
Begins 10 minutes after startup
(0) or when programmed (1)
=38
Minimum Temperature
Alarm
Set the display to flash should the inner temperature of the appliance drop beyond a specified
point from the programmed operating temperature
1°C to 50°C
Note: The cycle starts from the time the appliance is initially
powered up.
Note: Starting a manual defrost also resets the automatic
defrost timer.
The next automatic defrost will start six hours after the
manual defrost has finished.
Fault Probable Cause Action
The appliance
is not working
The unit is not switched on Check the unit is
plugged in correctly
and switched on
Plug and lead are damaged Call POLAR agent or
qualified Technician
Fuse in the plug has blown Replace the fuse
Power supply Check power supply
Internal wiring fault Call POLAR agent or
qualified Technician
The appliance
turns on, but
the
temperature is
too high/low
Too much ice on the condenser Defrost the appliance
Condenser blocked with dust Call POLAR agent or
qualified Technician
Doors are not shut properly Check doors are shut
and seals are not
damaged
Appliance is located near a heat
source or air flow to the
condenser is being interrupted
Move the refrigerator to
a more suitable location
Ambient temperature is too
high
Increase ventilation or
move appliance to a
cooler position
Unsuitable foodstuffs are being
stored in the appliance
Remove any excessive
hot foodstuffs or
blockages to the fan
Appliance is overloaded Reduce the amount of
food stored in the
appliance
The appliance
is leaking water
The appliance is not properly
levelled
Adjust the screw feet to
level the appliance
The discharge outlet is blocked Clear the discharge
outlet
Movement of water to the drain
is obstructed
Clear the floor of the
appliance
The water container is
damaged
Call POLAR agent or
qualified Technician
The drip tray is overflowing Empty the drip tray
The appliance
is unusually
loud
The frame has become loose Check and tighten all
nuts and screws
The appliance has not been
installed in a level or stable
position
Check installation
position and change if
necessary
4
UK
Error Messages
The following table details the cause and subsequent response of the appliance to errors.
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.
Technical Specifications
Electrical Wiring
POLAR Refrigerators and Freezers are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR Refrigerators and Freezers are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR Refrigerators and Freezers must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Compliance
BUFFALO parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and
federal authorities.
BUFFALO products have been approved to carry the following symbol:
Error Message
(flashing)
Cause Appliance Response Action
HtA
The inner temperature exceeds
the set maximum temperature
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
LtA
The inner temperature exceeds
the set minimum temperature
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
PF1
Short circuit or interruption of
the thermostat probe input line
Display flashes
Compressor operates as specified by
parameter ‘=23
PF2
Short circuit or interruption of
the evaporator probe input line
Display flashes Defrost as specified by parameters d8 and d9
HLA
Inner temperature greater than
90°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
LLA
Inner temperature lower than -
45°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
Model Voltage Power Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight
(Kg)
G590 230V 50Hz 250W 1.1A -2°C to 10°C 400 R134a 230 grams 1915 x 600 x 700 125
G591 230V 50Hz 250W 1.1A -15°C to -22°C 400 R404a 300 grams 1915 x 600 x 700 125
G592 230V 50Hz 450W 2A -2°C to10°C 600 R134a 230 grams 1990 x 660 x 800 120
G593 230V 50Hz 750W 5.8A -15°C to -22°C 600 R134a 410 grams 1990 x 660 x 800 120
G594 230V 50Hz 400W 3.5A -2°C to10°C 1200 R134a 400 grams 1990 x 1345 x 800 180
G595 230V 50Hz 750W 5.8A -15°C to -22°C 1200 R404a 440 grams 1990 x 1345 x 800 180
U629 230V 50Hz 450W 2A -2°C to 10°C 600 R134a 290 grams 1990 x 660 x 800 115
U630 230V 50Hz 650W 2.8A -2°C to 10°C 1200 R134a 500 grams 1990 x 1345 x 800 180
POLAR Telephone Helpline: (+44) 0845 146 2887
POLAR, Fourth Way, Avonmouth, United Kingdom, BS11 8TB
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Polar Refrigeration G593 User manual

Category
Barbecues & grills
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document