Temperature sensor
installation on pipe
The temperature sensors are fitted using heat conduct-
ing paste, cable ties (the first cable tie is secured to the
pipe in the middle of the sensor and the other cable tie
is mounted approx. 5 cm after the sensor) and alumini-
um tape. Then insulate them using the enclosed insula-
tion tape.
NOTE
Sensor and communication cables must not
be laid near power cables.
Fixed condensing
If SMO 20 is to control the air/water heat pump in rela-
tion to the water heater with fixed condensing, you must
connect an external supply temperature sensor (BT25),
according to the description on page 23. Place the
sensor in a suitable location in the tank In addition, you
must perform the following menu settings.
Menu setting (local variations
may be required)
Menu
Desired temperature in the
tank.
1.9.3.1 - min. flow line temp.
heating
Desired temperature in the
tank.
5.1.2 - max flow line temper-
ature
intermittent5.11.1.2 - charge pump
(GP12)
manual4.2 - op. mode
Docking alternatives
SMO 20 can be connected with other products from
NIBE in several different ways, some of which are
shown below (accessories may be required).
Further option information is available at nibe.eu and in
the respective assembly instructions for the accessories
used. See page 49 for a list of the accessories that can
be used with SMO 20.
Installations with SMO 20 can produce heating and hot
water. Cooling can also be produced, depending on
which heat pump is used.
On cold days of the year when the access to energy
from the air is reduced the additional heating can com-
pensate and help to produce heat. The additional heating
is also good to have as assistance if the heat pump ends
up outside its working range or if it has been blocked
for any reason.
NOTE
The heating medium side and the domestic
hot water side must be fitted with the neces-
sary safety equipment in accordance with the
applicable regulations.
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
13Chapter 4 | Pipe connectionsNIBE SMO 20