18
C. HEATER STARTS BUT IT DOES NOT RUN REGULARLY
a. Heater stops in lock-out and reset lamp is on (red light)
i.Flamefailurebecauseofmissingfuel
1.Checkfueltankisnotempty
2.Checkfueltypebecorrect,cleanandwithoutwater
3.Checkandcleanfuelltercartridge
4.Checkallconnectionsoffuellinefromtanktofuelpump:untightenedconnectionscancause
suction of air to fuel pump
5.Checkfuellinearenotobstructedordamagedandeventuallyreplace
6.Checkadjustmentoffuelpumppressure
ii.Flamefailurebecauseofbadcombustion
1.Checkandcleanfuelnozzle(eventuallyreplaceit)
2.Checkandcleancombustionhead(nozzle,nozzlesupportanddiffuserdisc)
3.Checkadjustmentoffuelpumppressure
4.Checkadjustmentofcombustionair
iii.FlamefailurebecauseofairpressureswitchPAnotworking.
1.Checkfanistightenedonfanmotorshaft.
2.Checkthereisnoobjectobstructingairinlet
3.Checkhosetoairpressureswitcharenoobstructed
4.Checkconnectionstoelectricalwiringsofairpressureswitch
5.Checkandeventuallyreplaceairpressureswitch
iv.FlamefailurebecauseofsafetythermostatLIcuttingin
1.Checkthereisnoobjectobstructingairoutlet
2.Checkairoutlethoserespectmaximumlengthanddiameterasspecied
3.Checkconnectionstoelectricalwiringsofoverheatingthermostat
4.Checkandeventuallyreplacesafetythermostat
b. Heater stops in stand-by and reset lamp is off
i. Voltage lower than 70 V or higher than 150 V
1.Checksupplyvoltageiscorrespondenttoratingplate.
2.Unitwillautomaticallyrestartwhenvoltagebecomeshigherthan80Vorlowerthan140V.
c. Heater starts and stops ames and main fan remains on (unit is in stand-by and rest lamp is off)
i.Airbubblesinthesuctionlinetofuelpump
1.Checkoilltercasingistightened
2.Checkallconnectiononfuellinetofuelpumparetightened
3.Checkfuellinearenotobstructed
4.Checkfueltanklevel
D. HEATER RUNS WITH BAD COMBUSTION AND EVENTUALLY WITH WHITE OR BLACK SMOKES
a. Heater runs with white smokes
i.Fuel/airmixingoncombustionheadisincorrect:excessairorlittlefuel
1.Checkadjustmentoffuelpumppressure
2.Checkadjustmentofcombustionair
b. Heater runs with black smokes
i.Fuel/airmixingoncombustionheadisincorrect:littleairorexcessfuel
1.Checkadjustmentoffuelpumppressure
2.Checkadjustmentofcombustionair
c. Heater runs with noisy / irregular combustion with/without smokes
i.Combustionisincorrect
1.Checkandcleanfuelnozzle(eventuallyreplaceit)
2.Checkandcleancombustionhead(nozzle,nozzlesupportanddiffuserdisc)
3.Checkexhaustisnotobstructed
4.Checkcombustionchamberisnotcloggedbysootandeventuallywashandcleanit