EOS SteamRock II Basic Operating instructions

Category
Power generators
Type
Operating instructions
INNO VATIVE S A U NA TECH N O L OGY
Made in Germany
EOS SteamRock II Basic
steam generator
EN
Installation and operation manual
print no. 2902 5140 / 27.20
Subject to technical changes
Version 00 | rmware R0.91
2
EN
3
EN
English
Contents
1. Identification ..................................................................................................................................5
1.1 Manufacturer ..................................................................................................................5
1.2 Copyright .........................................................................................................................5
1.3 Identification of the device ........................................................................................5
1.4 Intended use ...................................................................................................................5
1.5 Foreseeable incorrect use ..........................................................................................6
1.6 Applicable norms ..........................................................................................................6
2. Safety advice ...........................................................................................................................7-12
3. Delivery scope ............................................................................................................................ 13
4. Technical Data ............................................................................................................................ 14
5. Installation
5.1 Installation example ..................................................................................................15
5.2 Construction and location of components .......................................................16
5.3 Prerequisites on the installation site ................................................................... 19
5.4 Mechanical installation ............................................................................................ 21
5.5 Water and steam pipes .............................................................................................24
5.6 Mounting the steam pipe .......................................................................................27
6. Electrical installation ................................................................................................................ 30
6.1 SteamRock II Basic 18 kW connection terminals .....................................................30
6.1 SteamRock II Basic 9 kW connection terminals ....................................................... 31
6.2 SteamRock II Basic 9 -18kWmain circuit diagram ........................................... 32+33
6.4-6.5 Connection examples ........................................................................................ 34+35
6.7 Leakage current ..................................................................................................................36
6.7 Special advice for water quality .................................................................................... 36
7. Cleaning system ........................................................................................................................37
8. Adjustment of the performance ..........................................................................................39
9. General operation ..................................................................................................................... 41
9.1 Resetting the safety temperature limiter (STB) ....................................................... 42
10. Cleaning and servicing ............................................................................................................ 43
10.1 Regular maintenance ..................................................................................................... 43
10.2 Servicing the vaporiser tank / Checking the Niveausensor ............................. 43
10.3 Dismantle the vaporiser tank with heating spirals ..............................................46
11. Troubleshooting ........................................................................................................................ 49
12. Recycling ...................................................................................................................................... 49
13. Service Address: .........................................................................................................................51
13. General Terms and Conditions of Service ......................................................................... 52
4
EN
Introduction
Dear customer
Thank you very much for purchasing EOS sauna & steam equipment. You have purchased a mod-
ern, technically advanced product which will provide you with years of reliable operation.
EOS steam generators have been designed and tested to comply or exceed the currently applica-
ble European safety norms and are produced in our factory in accordance with the quality man-
agement norms DIN EN ISO 9001:2015.
This installation manual or operating guide is intended for your information. Please read it careful-
ly before installing and operating the steam generator, in order to prevent damages of the device
or physical injuries. Please keep this document for further references.
We wish you a pleasant and relaxing time in your steam room.
Your EOS team.
5
EN
A Product description
B Model name
C Product code (item no.)
D Supply voltage (model dependent)
E Operating pressure Pascal (bar)
F Country of origin
G Manufacturer
H Production date
I Serial number
1. Identication
1.1 Manufacturer
EOS Saunatechnik GmbH
Schneiderstriesch 1
D-35759 Driedorf
Tel.: +49 2775 82-0
Fax: +49 2775 82-431
1.2 Copyright
The copyright owner of the present installation manual and operating guide is EOS Saunatechnik
GmbH.
Copyright as per DIN ISO 16016:
The copying and distribution of this document, as well as the use and communicatio n of its con-
tents without express authorisation, are not permitted. Compensation will claimed in the event of
infringements. All rights reserved with regard to patent claims or submission of design or utility
patent.
1.3 Identication about the unit
Product name
SteamRock II Basic
1.4 Information about the unit
Nameplate
The nameplate is attached to the underside of the base of the housing.
Dampfgenerator
Type SteamRock II Basic
Art.-Nr. 94 XXXX 0X
XXX V XN AC XX kW
0 Pa (0 bar)
Made in Germany
EOS-SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 23.20 00001
A
B
C
D
E
F
G
H I
6
EN
1.5 Intended use
The SteamRock II Basic steam generator is intended for production of steam in steam rooms or
sauna rooms with humid operation. The SteamRock II Basic requires an external control unit (e.g.
EOS Econ S2) which is not included in the scope of delivery. Third party control units may not be
used without prior written consent of EOS Saunatechnik GmbH.
1.4 Foreseeable incorrect use
Following may be regarded as foreseeable incorrect use:
Steam room size does not match the steam generator power (incorrect power selection).
Incorrect connection of the steam generator and control unit.
Operation without proper knowledge of the safety instructions (chapter 3).
Operation without adherence to the required operation rules, maintenance and servicing re-
quirements.
Operation of the device after unauthorized technical alterations or repairs.
The unit is operated by children or persons with reduced mental capacity or by persons who
have not been thoroughly instructed in its use.
Operation or use by persons with certain ailments or health conditions, such as for instance
heart and cardiovascular disorders, which might lead to physical injuries through the use of a
sauna or a steam room (a doctor should be consulted in advance).
7
EN
2. General safety instructions
Safety instructions and important operating instructions are classied according to ANSI Z535.6.
Please familiarise yourself with the following terms and symbols:
Safety levels
Danger
Indicates a hazardous situation which, if not avoided, will result in death.
Warning
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Caution
Indicates a hazardous situation which, if not avoided, could result in minor or moderate in-
jury.
Notice
Indicates a hazardous situation which, if not avoided, will result in damage to the unit.
DANGER
WARNING
CAUTION
NOTICE
8
EN
General safety instruction - Mounting and electric installation
These installation instructions are intended for qualied personnel familiar with
the laws and regulations applicable to electrical installations at the installation
site. Observe the following general safety instructions during assembly, setup
and commissioning.
DANGER
Risk to life and limb and risk of re
Risk to life and limb from electric shock and re in the event of improper or faulty electri-
cal connection. This risk also applies following completion of the installation work.
The electrical installation of the steam generator and other electrical systems or
equipment with a xed mains connection must only be performed by a trained
electrician from an authorised electrical company.
Observe the stipulations in VDE 0100 part 701 or applicable local regulations.
The system must be disconnected and removed entirely from the mains supply
before commencing installation and repair work.
WARNING
Fire hazard from overheating
Insucient ventilation can lead to device overheating and re.
Do not install the control panel and power units in enclosed cabinets or wood
panelling.
Do not install steam generators in enclosed cabinets or wood panelling.
WARNING
Risk of burns
Touching hot pipelines can result in skin burns.
Insulate hot device parts.
Insulate hot pipelines; they must not remain exposed.
9
EN
General safety instruction - Mounting and electric installation
WARNING
Risk of poisoning from steam
Descaler can react with other chemicals, which can create poisonous steam.
Place the container for descaler only under the steam generatorand secure it so it
does not tip.
Ensure that the container with descaler cannot be mistaken for the container with
essence.
When relling a container, ensure that descaler is not poured into the container for
essence.
Never place containers with descaler close to other chemicals.
Never place other chemicals close to the container of descaler.
WARNING
Risk of scalding
Contact made with hot steam or hot water can result in scalding of the skin.
The steam pipe must always have an unobstructed exit outlet in the cabin.
The hose for excess pressure and the drain outlet for emptying the vaporiser tank
must be routed in such a way that there is no risk of scalding if hot water escapes
unintentionally.
When commissioning, take measurements to ensure that the set output does not
heat the cabin to over 50°C.
Wear safety goggles/protective clothing (gloves).
WARNING
Risk of chemical burns
Descaler consists of an acidic solution, which can burn eyes and skin.
Wear eye and skin protection when connecting the descaler line and relling descaler.
Clean contaminated clothing thoroughly.
10
EN
NOTICE
Damage to the unit due to high levels of lime
Lime deposits clog the vaporiser tank, slowing down the transfer of heat to the water.
This can lead to malfunctions because of overheating and blockages in the drain. A water
softening system does not replace regular descaling.
Non-compliance with these guidelines resulting in damage to the unit renders the
warranty void.
Check the hardness of the water before installing the unit.
In locations where the water is high in calcium carbonate (above 5° dH), a water
softening system is recommended.
If the level on the hardness scale is 11° dH or above, connecting a water softening
system to the steam generator is recommended.
A water softening system is required if the steam generator is used commercially.
NOTICE
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the control panel, in the
relay box and in the sensors.
The control panel and sensors should not be installed in a corrosive or heavy saline
atmosphere.
General safety instruction - Mounting and electric installation
11
EN
General safety instruction - Operator Instruction
The operator of the steam generator must be instructed in the general safety instructions dur-
ing commissioning. The operator must be given a copy of the instructions for use.
DANGER
Risk of electric shock
A risk to life and limb from electric shock and re arises in the event of improper repair
work. This risk also applies after work is completed.
The housing cover must only be removed by a specialist.
Repairs and installations must only be performed by a trained specialist.
The system must be disconnected and removed entirely from the mains supply
before commencing repair work.
Use only original spare parts from the manufacturer.
WARNING
Risk of burns and chemical burns
Touching hot parts may lead to skin burns and chemical burns of the skin.
The operator must be familiar with the unit’s hot parts and be able to identify them.
The operator must be familiar with the settings for the steam supply and understand
how it is controlled.
WARNING
Health risks
Spending time in a steam room can lead to serious health risks or even death for persons
with health impairments.
These persons must consult with a doctor before visiting a steam room.
12
EN
General safety instruction - Operator Instruction
NOTICE
Equipment damage due to overuse
In commercial steam rooms, excessive humidity in the spatial surroundings of the steam
room(s) can lead to material damage
In a commercial steam room, the steam generator must be set so that it turns itself
o after a specic period of time.
If the steam generator does not shut itself o, usage must be supervised at all times.
Inspect the steam room each time you start the system.
WARNING
Operation by children or persons with reduced mental capacity
Children and persons with reduced mental capacity can be a risk.
Children must be supervised to ensure they do not play with the unit.
Children under 8 years of age should not operate the steam generator.
The settings for the steam generator may only be used by children over 8 if they are
supervised by an adult.
The steam generator must only be started by persons with reduced mental capacity,
or limited physical or sensory abilities under supervision or if they have already been
instructed in its use and understand the risks.
Children and persons who have not received proper instruction must not clean or
service the system.
13
EN
3. Scope of delivery
The SteamRock II Basic scope of delivery includes:
SteamRock II Basic steam generator
4 screws 5 x 40 with 4 dowels F6 for installing the steam generator on the wall
2-part brass union 1 1/4“ - 35 mm for steam pipe connection
0,5 m connection hose for water supply 3/8“ - 3/4“
5 l container for descaler liquid with rod electrode (level sensor)
Installation & user manual
Pre-mounted power supply cable with CEKON type plug (16A or 32A)
Steam outlet, 1 1/4“ external thread
14
EN
3. Specications
Dimensions H x W x D [mm] 670 x 460 x 350 mm
Weight [kg] 28 kg (type 1 - 9 kW) / 30 kg (type 2 - 18 kW)
Water supply pressure [bar] 2 - 8 bar
Operation pressure max. [bar] Pressureless type steam generator
Performance at 3 bar [steam/h] 3 kW - 4 kg/h, 6 kW - 8 kg/h, 9 kW - 12 kg/h, 12 kW - 16
kg/h, 15 kW - 20 kg/h, 18 kW - 24 kg/h
Vaporizer tank High grade stainless steel
Internal overheating protection Thermofuse with capillary sensor, 3-pole circuit
breaker
Heating system External heating elements, switchable in 3 kW steps
Cleaning and drain system Integrated automatic descaling and draining
system, built-in peristaltic pump, external 5 l
container for cleaning liquid with level probe
Water drain 1“ drain pipe at the unit’s bottom side
Water level control Automatic with overheating protection
Control system not included (external control unit required)
Water supply ¾“ external thread
Steam output 1 1/4“ external thread, with 2-part brass union
Ambient temperature (operation / storage)
5°C to 45°C / 0°C to 60°C
Ambient humidity (operation) 30% bis 75%
Outputs / Connections Mains (pre-mounted mains cable)
Connection for external control unit
Connection for Level sensor in the descaler tank
Connection for Level sensor in the fragrance con-
tainer
Power output [kW] type 1 - 3.0 / 6.0 / 9.0 kW (9 kW default)
type 2 - 9 / 12 / 15 / 18 kW (18 kW default)
Fuse protection [A] type 1 - 3 x 16 A
type 2 - 3 x 32 A
Min. cross section power supply line type 1 - 5 x 2,5 mm²
type 2 - 5 x 6,0 mm²
Power supply 400 V 3N AC, 50/60Hz, with pre-mounted mains
cable with Cekon-type plug
15
EN
5.1 Installation example
5. Installation
1000
300
150-250
1600 - 1700
drain
steam pipeline
steam outlet
cabin lighting
door
sensor
drain in the
steam cabin
container for descailer
* For installation details of the tem-
perature sensor please refer to the
installation manual of the respec-
tive control unit.
steam generator
duct vent
(ceiling panel)
16
EN
5.2 SteamRock II Basic - position of key components
top view
*The prime heating element (G) has a special colour-coded marking of the connection wire. This
specially marked heating element (G) is located next to the overheating limiter fuse (F). After dis-
connection make sure, that this heating element (G) is connected to the same colour-coded wire.
Incorrect connection may lead to damages to the unit.
D
B
A
C
A drain line of the pressure relief valve
B pressure relief valve with drain
C water supply line
D descaler liquid supply hose
E water tank lid
F tube for overheating limiter fuse (STB)
G mounting nuts SW 19 and connection terminals for *heating elements
H rinsing line (high pressure water jet)
I water level probe (level sensor)
J steam output pipe with exible pivot joint
K chassis (rear side with ventilation holes)
K
J
I
H
G
E
F
example of the 9 kW unit
NOTICE
17
EN
drain line from pres-
sure relief valve
Status LED for operation
states and error signals
Bottom view
water supply, 3/4” ex-
ternal thread
water tank drain, 1“ external
thread
cable to descaler level probe
mains connection*
9 kW: with pre-mounted cable and CEE-plug 16A
18 kW: with pre-mounted cable and CEE-plug 32A
no pre-mounted power plug for single-phase connection!
white hose for descaler (plugs
into the container for descaler)
steam output, 1 1/4”
external thread
connection (strain reliefs) for cable
connection to control unit
* The cable gland of the mains cable has a warrant
seal. Make sure not damage the seal. Warranty void
by damaged or removed seal.
All incoming and outgoing connections go through
the bottom panel (steam pipe may also lead up-
wards) and are accessible from outside.
18
EN
water tank
main terminal bank with
colour-coded terminals
main board
water supply line
dual way magnet valve
(water supply)
Status LED for operation
condition and error signals
F-fuses for heating elements
9 kW - F1/F2/F3
18 kW - F1/F2/F3/F4/F5/F6
descaler pump
pressure relief valve drain
thermal fuse (STB)
with reset button
drain valve with actuator
contactors
Mains cable is tted with a Cekon plug
(not with single-phase connection)
pressure relief valve
descaler supply hose
Overview without external housing
example of a 18 kW unit
19
EN
5.3 Installation location requirements
The steam generator is only intended for installation outside of steam rooms and is connected to
the room via a steam pipe. The following climatic conditions must be met at the installation site:
Ambient temperature during operation 5°C to 40°C
Air humidity during operation 30% to 75% rel. air humidity
Storage temperature: 0°C to 60°C
Stable wall for installation as the total weight can equal approx. 45 kg.
Near the unit: Mains connection 400 V 3N AC, with standardised CEE plug sockets (not with sing-
le-phase connection)
Drain outlet below the unit or in close proximity
Water supply line in close proximity
Length of steam pipe, max. 10 m
All pipelines and connections must be accessible for service.
The room in which the steam generator is installed should be as near to the steam room as pos-
sible so that the pipeline distances are as short as possible.
Steam room requirements
Floor drain
Air extractor so that temperature control works properly
Steam generator requirements
Stable wall
Mains connection (as per technical data)
Water connection
Drain outlet
20
EN
alle Maße in mm
all sizes in mm
535
670
min. 500
1000
460
420
min. 250
min. 250
NOTICE
Damage due to inadequate installation site
The steam generator may vibrate slightly when the water boils.
If the wall bearing capacity is insucient or the wall is of poor quality, the steam generator
cannot be securely installed and may fall o.
Before installation, check the quality and bearing capacity of the wall intended for instal-
lation. The wall must be able to support a total weight of max. 45 kg.
Before installation, check how the steam pipe is to be laid. Standard routing leads the
line out from the steam generator downwards.
Measurements for installation
The following distances must be observed:
Distance bet-
ween drill holes
Horizontal: 420 mm
Vertikal: 535 mm
On the side to the
left and right
Min. 250 mm
Top Min. 500 mm
Bottom Approx 1000 mm
The space underneath the unit may not be
occupied by other installations.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

EOS SteamRock II Basic Operating instructions

Category
Power generators
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI