POINT PRO HYDRO LUFTFUKTER Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the POINT PRO HYDRO LUFTFUKTER Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Hydro
Ultrasonic Humidifier
POHYDRO
User Manual
2
GB
NO
FI
DK
SE
Thank you for purchasing your new
Point Ultrasonic Humidifier.
These operating instructions will help you use it properly and safely. We recommend
that you spend some time reading this instruction manual in order that you fully
understand all the operational features it oers. Read all the safety instructions
carefully before use and keep this instruction manual for future reference.
Takk for at du kjøpte ditt nye Point Ultrasoniske Luftfukter.
Denne bruksanvisningen vil hjelpe deg med å bruke den på en trygg og riktig måte. Vi
anbefaler at du tar deg tid til å lese gjennom hele bruksanvisningen for å bli fortrolig
med alle funksjonene som tilbys. Les alle sikkerhetsanvisningene nøye før bruk, og
oppbevar bruksanvisningen for fremtidig referanse.
Kiitos, kun valitsit uuden Point Ultrasonic-ilmankostuttimen.
Nämä käyttöohjeet opastavat sinua käyttämään laitetta oikein ja turvallisesti.
Suosittelemme, että käytät hetken tämän käyttöoppaan lukemiseen, jotta ymmärrät
täysin, mitä toimintoja laitteessa on. Lue kaikki turvallisuusohjeet huolellisesti ennen
laitteen käyttöä ja säilytä käyttöopas myöhempää tarvetta varten.
Tak for købet af dit nye POINT Ultrasoniske Luftfugter.
Disse brugervejledninger hjælper dig med at bruge dette apparat rigtigt og sikkert. Vi
anbefaler, at du læser denne brugervejledning, så du får en fuld forståelse af hvordan
alle funktionerne virker. Læs sikkerhedsforskrifterne grundigt inden brug, og gem
denne brugervejledning til senere brug.
Tack för att du har köpt ditt nya POINT Ultraljudsluftfuktare.
Denna bruksanvisning hjälper dig att använda den på ett säkert och korrekt sätt.
Vi rekommenderar att du tar dig tid att läsa igenom denna bruksanvisning för att till
fullo förstå alla driftfunktioner som den erbjuder. Läs noga igenom alla
säkerhetsinstruktioner före användning och spara bruksanvisningen för framtida bruk.
3
NO
DK
SE FI GB
Instruction Manual – English ..........................page 4 - 21
Bruksanvisning – Norsk ...................................side 22 - 39
Käyttöopas - Suomi .........................................sivu 40 - 57
Brugervejledning – Dansk ................................side 58 - 75
Bruksanvisning – Svenska ...............................sida 76 - 93
4
SAFETY WARNINGS
Read all the safety instructions carefully before use and keep this
instruction manual for future reference:
Follow all the safety precautions listed below for safety
and to reduce the risk of injury or electrical shock.
This appliance can be used by children aged 8 years and
older and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they are
supervised or instructed on the safe use of the appliance
and understand the hazards involved. Children are not to
play with the appliance. Cleaning and user maintenance are
not to be carried out by children without supervision.
Before using this appliance ensure that the voltage of your
electricity supply is the same as that indicated on the
rating plate of the appliance.
Always place the humidifier on a hard, flat and level
surface. Avoid exposure to direct sunlight and always keep
it away from walls and heat sources such as stoves,
radiators, etc. Warning: The appliance may not work
correctly if it is not placed on a level surface.
Do not insert or remove the electric plug on the appliance
with wet hands.
If the mains power cable is damaged, it must be replaced
by the manufactures, its service agent, or similarly
qualified persons in order to avoid a hazard.
To reduce the risk of electric shock, do not try to
disassemble it. The unit does not contain any
userserviceable parts. Leave all maintenance work to
qualified personnel.
Fill the tank with fresh, distilled or demineralised water.
Do not switch on the appliance when there is no water in
the tank.
Do not shake the appliance as this might cause the water
to spill over into the base unit.
5
If you spill any liquid into the unit, it can cause serious
damage. Switch it o at the mains power supply
immediately. Withdraw the mains plug and consult your
dealer.
Never touch the water or components while the unit is in
operation.
If there is an unusual smell when the device is being used
as described in this manual, switch the appliance o,
unplug it and have it examined by your dealer.
Do not pour hot water into the tank, i.e. at a temperature
in excess of 40 degree °C.
Unplug the appliance before cleaning it or removing the
tank.
Do not immerse the appliance or the mains power cable or
plug in water or other liquids.
Never scrape the transducer with a hard tool. The
humidifier must be cleaned regularly. To do this, refer to
the cleaning instructions in this manual.
Disconnect the appliance from the mains power supply
when not in use and before cleaning. Ensure that the
mains power cable does not touch any hot surfaces and
that it does not hang over the edge of the table.
Never use this appliance in a room where aerosol products
(sprays) are used or in a room or where oxygen it being
administered.
Do not put items of clothing or towels on top of the
appliance. If the nozzle is obstructed, this may cause the
appliance to malfunction.
When moving the appliance, lift it by the base unit and not
by the water tank.
GB
6
Do not use the humidifier if the air in the room is already
suciently humid (relative humidity of at least 50%). The
ideal relative humidity level for human comfort is between
45% and 60%. Excess humidity shows in the form of
condensation on cold surfaces or cold walls in the room. To
measure the rooms humidity correctly, use a hygrometer
available in most specialist shops and hypermarkets.
The humidifier is designed for indoor and domestic use
only.
Be aware that high humidity levels may encourage the
growth of biological organisms in the environment.
Do not permit the area around the humidifier to become
damp or wet. If dampness occurs, turn the output of the
humidifier down. If the humidifier output volume cannot
be turned down, use the humidifier intermittently. Do not
allow absorbent materials, such as carpeting, curtains,
drapes, or tablecloths, to become damp.
Never leave water in the reservoir when the appliance is not
in use.
Empty and clean the humidifier before storage. Clean the
humidifier before next use.
Warning: The water should be renewed and the tank
properly cleaned at least every 3 days to prevent the
growth of micro-organisms that may be present in the
water or in the environment where the appliance is used. If
the micro-organisms are allowed to grow in the water
reservoir and are blown in the air during use, they can
cause very serious health risks.
7
Clean the water tank every three days.
Empty the tank and refill every third day. Before refilling, clean it with fresh tap
water or cleaning agents. Remove any scale deposits, or film that has formed on
the sides of the tank or on interior surfaces, and wipe all surfaces dry.
Filter cleaning/changing.
Clean filters as described on page 20.
CAUTION: Hot water vapour.
Working Principle: Your Ultrasonic Humidifier uses the ultrasonic high-frequency
oscillator to break up water into tiny water particles with the diameter of about
1-5um.The ventilation system blows out this water into the dry air where it
evaporates. The clearly visible smooth and even fog can be seen coming out of the
unit.
Features:
Highly ecient humidification process with large output.
Low energy consumption, save up to 85-90 percent of electricity compared to that of
a normal steam humidifier.
Long lifetime.
Automatic control of humidity level, lack-of-water security protection.
GB
8
Correct Humidity Level:
Relative humidity is the amount of water vapor in the air, expressed as a percentage of the
maximum amount that the air could hold at the given temperature. It is normally marked
with RH, like 45RH.
Atmospheric air always contains water vapor, the percentage of which depends on the
meteorological conditions. The higher the temperature is, the more water vapor the air can
contain. Therefore, we use the concept of ‘relative humidity. When cold air is heated up to a
comfortable temperature in winter, the relative percentage of the water vapor falls, which
means the relative humidity drops. In order to keep a comfortable and healthy environment
at home, we need some artificial addition of water or water vapor to the room air – air
humidification.
Ideal relative humidity levels under di˛ erent situations.
The most comfortable RH for human being 45-65RH
Ideal RH for prophylactic and curative purpose: 40-55RH
Computer and telecom apparatuses: 45-60RH
Furniture and musical instruments: 40-60RH
Libraries, art galleries and museums: 40-60RH
FUNCTIONS
1. Relative Humidity
The term used to describe the amount of water vapor in a specific volume of air at a particular
temperature is known as relative humidity, usually marked as %RH, i.e. 45%RH.
The presence of water vapor in the air can fluctuate. The ratio of water vapor to air changes
depending on the temperature; higher temperatures typically result in increased amounts of
water vapor present in the air.
2. Water filter:
1) The plastic part is mixed with a NANO-SILVER material to prevent the growth of bacteria.
2) Ceramic balls soften hard water.
3) Ceramic filter eliminates unpleasant smells in the water.
9
PRODUCT OVERVIEW
ON/OFF
MAX/MIN
HUMIDITY
TIMER
PLASMA
AUTO
Top Cover
Nozzle
Filter
Handle
Water Tank
Water Supply Controller
Housing
PTC Heating
Control Panel
Aroma Box
Transducer PCB
Air Outlet
Power Cord & Plug
Mist Block Cover Base
GB
Remote Control
Before using the remote control, ensure that the plastic tab has been removed from the
battery compartment.
10
WIFI CONNECTION
1. Download the application.
Scan the QR code to download the Smart
Life APP. Or search for the Smart Life in
APP stores.
2. Registration and log in.
Open the Smart Life App to register an
account by using either your phone number
or email address.
3. Please make sure below 3 points are satisfied.
a. Connect the mobile phone to a 2.4Ghz internet-connected router.
b. Activate the phone’s Bluetooth function.
c. Keep the humidifier, cell phone and router as close to each other as possible.
4. Connection via Bluetooth.
Long press the humidifier’s ‘Power’ button for
about 3 seconds until you hear a beep. WIFI
icon flashes quickly. It means the device has
entered the networking state successfully.
a. Enter the App. The device will automatically
pop up onto the screen. It can also be searched by
clicking Add Device button. Choose the
corresponding device (if there are many) and
press Add.
11
b. Enter and check your WIFI name and password then click Next.
c. Press Done to complete the process once the device is added.
5. Connect manually
Same as step 4 to set the humidifier in the networking state.
a. On the home page, click Add Device or the ‘+’ icon in the upper right corner, then choose Add
Device.
b. Select ‘Small Home Appliances’ on the left side categories, then find and click ‘Humidifier
(Wi-Fi)’ under ‘Surroundings’ on the right side.
GB
12
c. Enter and check your Wi-Fi name
and password, then click ‘Next’.
d. Touch ‘Confirm the indicator is blinking’ and then ‘Blink Quickly’ button.
13
e. Wait until your device is shown on the screen and click ‘Done’ at the bottom to finish the
adding process.
6. When the App is connected to your humidifier successfully, the WIFI icon on the screen
will stop flashing. Now you can control the humidifier by the phone.
GB
14
OPERATION
During first time use, put the humidifier in room temperature for half of an hour before
running.
It is recommended to use the humidifier with ambient temperature under 20°C and relative
humidity less than 80%RH.
Use clean water under 40°C in temperature.
Check the water basin, make sure it is clear.
Put the humidifier on a flat surface.
Open the top cover and pour water into the water tank, then place back the top cover.
Or take out the water tank for filling in and then place it back on the main base.
Check if the rated voltage meets the input voltage and plug the device into a socket. The
display will show the POWER symbol and the buzzer rings once. 1 second later, if the
water tank is not in place, the display will show a red flickering POWER button. If there is a
water tank in but no water, the display will show a lack of water icon . If there is too much
water in the water tank, the display will show ‘EF’. If the water level is proper, the
display shows POWER button in red, and the device enters into standby mode.
Touch the POWER button on the unit. The background LED light will be on. The unit will
begin to work in AUTO mode. The display will show the temperature, the current humidity,
and the corresponding mist output symbol . In AUTO mode, the unit determines the
optimal humidity and starts to work towards it at maximum power. When the current
humidity is low, the unit enters high speed operation. When the humidity gets higher, the
unit will then enter low speed operation. The device will work according to the table below.
1.
2.
3.
4.
AUTO MODE HUMIDITY TABLE
You may select the humidity range from 30%RH to 75%. Touching once will increase by
5%RH each time. After you set the expected humidity, the device will keep the memory and
confirm by flashing 3 times and then switches to show current humidity.
-
-
-
-
-
When set humidity is 1%RH~9%RH higher than current humidity, mist output speed will
run by the minimum speed 1.
When set humidity is 10%RH~15%RH higher than current humidity, mist output speed will
run by the middle speed 4.
When set humidity is 15%RH higher than current humidity, mist output speed will run by
the highest maximum speed 7.
When current humidity is higher than set humidity, the humidifier will shift into sleep
state. Once current humidity is 3%RH lower than set humidity, the humidifier will resume
in the above working mode.
Hold down this button for 2 seconds to exit the constant humidity mode and switch to
AUTO mode.
NOTE: Under this mode, the slide touch bar is unavailable for mist adjustment.
Ambient
Temp( C)
Recommended
humidity RH%
<18 19-20 21 22 23 24 25-26 27 28 29 30 31 32 33 34 35-36 37 38 >39
65 60 60 55 55 55 50 50 45 45 40 40 35 35 35 30 30 30 30
5. Constant Humidity: Touch the HUMIDITY button . Display flashes ‘--’ and shows symbol .
15
Timer setting: You can set a timer for 1-12 hours with 1-hour intervals. Touch the TIMER .
The display will show ‘00’, the icon and ‘H’ as well. With another touch it shows ‘01’.
After the timer is set, the device will keep the memory and confirm by flashing 3 times.
The timer shows the rest of the operation time every minute and decreases by 1 hour, i.e., if
the timer is set at 12 hours, display shows 11 after 1 hour.
To cancel the timer, you can touch the TIMER button until the display shows ‘00’. As a
shortcut, you can also long press the button for 2 seconds to cancel the timer.
Degerming: Touch the DEGERMING symbol . The LED display will show the HEATING
symbol . Warm mist will come out after 10~15 minutes. Touch again to start the
plasma(degerming) function while the display shows the PLASMA icon . Touch for a 3rd
time, the heating function will be shut down. Touch for a 4th time, the plasma(degerming)
function will be shut down.
Night Mode: Touch the SLEEP button to enter into night mode. All the lights will be
turned o except the SLEEP button in 1/3 lightness. When touch any buttons, the control
button backlight and the display light up in 1/3 brightness. Then you can press buttons to
change functions or press SLEEP button to exit the mode within about 15 seconds.
NOTE: Long touch the button to turn on/o water tank lights when it’s not under the
Night Mode.
Mist Output Speed: In AUTO mode, slide the ‘slide touch’ button to exit AUTO mode and
enter manual mode (Total 7 levels). In the sliding process, the humidity value is converted
to display 1~7, and after 3 seconds the display will show current environmental humidity.
If there is no operation in about 15 seconds, no matter which working mode, the control
button backlight and the display will turn dim in 1/3 brightness. Touch any button to wake
up the backlight and then to operate the device.
Auto Shut-O: Once the water in the basin is not enough to keep the humidifier working,
the humidifier will automatically stop and stay in standby mode. Display will show a water
shortage symbol only in 1/3 brightness and will give warning with 3 beeps (no sound
under NIGHT mode). Unplug from the main socket and refill the water tank. Plug in again
and press the power button to restart the humidifier.
6.
7.
8.
9.
10.
11.
GB
16
Press out the aroma box from the base.
Use water-soluble aroma oil and drop some on to the sponge.
Put the aroma box back into humidifier, the aroma function will remain on when the
humidifier is running.
To stop the aroma function or when storing the humidifier, clean the sponge in the aroma
box.
Only drop aroma oil into the aroma cotton. Do not drop any liquid except clean water into
water tank or basin. (pictures only for reference)
Replace the Remote-Control Battery
1. Take out the battery compartment by pinching the tab and pulling the compartment out as
in the picture below.
2. Remove the old battery.
3. Replace it with a new battery. Make sure that the polarities match.
4. Put the battery compartment back.
1.
2.
3.
4.
5.
Aroma box
Pinch Pull out
17
TROUBLE SHOOTING GUIDE
If there is any trouble during normal operation, refer to the solutions below:
GB
Trouble
Possible Cause
Solution
Power lamp is
o when
switched on.
Humidifier is not plugged in. Plug the humidifier into a powered
electrical socket.
Power cord is damaged.
Immediately discontinue use and contact
Customer Support.
Humidifier is defective or
malfunctioning.
Power lamp is
on when
switched on,
but no mist
comes out.
Humidifier is not turned on. Press the power button to turn it on.
The target humidity is reached.
Increase the target humidity or change
mode.
Water
shortage
indicator is on.
No water in the tank.
Refill the water tank and wait at
least 1 minute.
Water level is low.
The water level required has not yet
reached the vaporization
compartment.
Wait at least 1 minute.
The water tank isn’t well positioned.
Check the positioning of tank on the base.
The humidifier isn’t on a flat surface. Check the positioning of the humidifier.
Humidifier
produces an
unusual smell
Humidifier is new. Take out water tank, open cover, let it stay
12 hours in a cool place.
Dirty water or water sitting too long.
Clean water tank, fill with clear water.
Residual smell from diusing aroma
oil on the aroma cotton.
Remove the aroma cotton, rinse it under
clean water and allow it to dry.
Humidifier
makes a loud
or unusual
sound.
Resonance in water tank when water
is too low.
Fill water into water tank.
Humidifier is on an unstable surface. Move the humidifier to a stable flat
surface.
Water tank is positioned incorrectly.
Turn o and unplug the humidifier, then
align the water tank cover with its
respective opening in the inner chamber.
Humidifier is malfunctioning. Immediately discontinue use and contact
Customer Support.
The
humidification
capacity is too
low.
There is natural or artificial air
replacement in the room which
interfere the increase of %RH.
Check if doors and windows are closed.
Check that there is no air
conditioning working in the room.
The air inlet grids, and nozzle could be
blocked.
Remove any blocking items from the grids
and the nozzle.
Too much scale in the water basin.
Clean transducer.
The humidity selected rate is too low. Increase mist output speed.
Increase humidity setting rate.
18
Water is too dirty, or water kept too
long in the tank.
Clean water tank, change to fresh clear
water.
The ambient
humidity is too
high.
Humidifier is working in CONTINUOUS
MODE.
Change the mode.
The humidity target is too high.
Select a lower %RH target.
Room is not well-ventilated.
Open a window to ensure proper air flow
for your humidifier or move the humidifier
to a more well-ventilated room.
Excess water, tank has spilled while
filling the water tank or replacing the
water tank back onto the base.
Wipe o excess water from the top and
bottom of the base before replacing the
water tank.
There is
condensation
in the room.
The room temperature is too low.
Heat the room up.
The mist
suddenly stops
coming out.
Programmed timer period has run
out.
Turn humidifier on.
The water shortage indicator is on.
Refill water tank.
The target humidity level is reached.
Incorrect
humidity level
is being
displayed.
Room is larger than the eective
range of the humidifier.
Move the humidifier to a room which is
within the suitable room size.
Moisture has built up inside of the
humidity sensor.
Turn o the humidifier and allow the
humidity sensor to completely air dry
before resuming use.
The nozzle is facing the direction of
the humidity sensor.
Turn the nozzle so that it is facing away
from the humidity sensor.
Humidity sensor is broken or
defective.
Contact Customer Support.
Control panel
does not work.
Hands are too wet when operating
control panel.
Keep hands dry while operating the
control panel.
Humidifier has malfunctioned. Contact Customer Support.
White dust
appears
around the
humidifier.
Water being used has a high mineral
content.
Use distilled water with the humidifier. If
distilled water is not available, use
purified or filtered water. Remember to
clean water tank at least once a week.
Humidifier was not properly cleaned
after last use.
Clean humidifier.
Mist is coming
out from the
base.
Water tank is not positioned correctly.
Turn o and unplug the humidifier, then
align the water tank cover with its
respective opening in the inner chamber.
Mist fog
coming out
from around
nozzle.
There are apertures between the
nozzle and water tank.
Reposition the cover and check if the
nozzle is well plugged in the cover.
19
If your water is very hard (containing abnormally high levels of minerals) the humidifier may
produce white dust. This is not a malfunction. The solution would be to clean the filter more
often or use softer water.
If you stand very close to the humidifier, you will hear the gurgling sound of water. This is
normal.
The humidifier operates very quietly but it is not completely silent. Noise levels less than
38dB(A) is considered normal.
1.
2.
3.
The following is not considered faulty operation:
GB
The humidifier is in warm-up phase. Wait a few minutes till the end of the
phase.
unction doesn't
roduce warm
mist.
The mist is too fine to feel the
warmth.
Increase the speed level.
The room temperature is too cold and
the mist may cool down too quickly.
Increase the speed level and heat the
room up.
Remote
control does
not work.
Remote control is out of range from
the humidifier.
Use the remote control within 5m of the
humidifier.
The plastic tab blocks the battery. Remove the plastic tab from the battery
compartment.
Battery needs to be changed.
Replace the battery.
Display shows
error code EF.
Too much water in water basin.
Remove water tank and empty water
from the base.
Check and clean particles in the water
outlet of water tank that lead to leakage.
If no leaks, replace into base.
Display shows
error code E0,
E1, E2.
The unit needs repairing.
Contact the vendor or service center.
20
MAINTENANCE
In a case when the water is hard which means water contains too much calcium and
magnesium, it can cause a “white powder” problem and leave heavy scale on the surface of
water basin, transducer, and inner surface of the water tank. Scale on the surface of
transducer will cause the humidifier to work improperly.
Use cold boiled water or distilled water.
Clean the transducer, water tank and water basin every 3 days.
Change the water in the water tank more often to keep it fresh.
Make sure to pour out water from the water tank and dry the water basin before you store
it unused for a long time.
Clean the whole humidifier and make sure that all parts of the humidifier are dried
completely if it is supposed to be left unused for a long time.
1)
2)
3)
4)
5)
We recommend:
How to clean the transducer:
1) Clean with clean water or citric acid if there is scale in it.
2) Brush o the scale from the surface.
3) Rinse the transducer with clean water.
How to clean the water basin:
1) Clean the water basin with soft cloth or use citric acid if there is scale in it.
2) Rinse the water basin with clean water.
How to clean ceramic filter:
1) Clean and activate the ceramic ball filter regularly. The frequency depends on water
quality. If ceramic balls are dirty, it needs to be cleaned more frequently.
2) Clean the filter by dipping it in vinegar for about 5 minutes. Then rinse it clean with clean
water.
3) Dry the filter under the sunlight for 4~6 hours.
1/94