Zhurui PR10-E User manual

Type
User manual

Zhurui PR10-E is a power recorder that can measure and monitor power consumption of household appliances, factory equipment, and office devices. It displays various electrical parameters such as voltage, current, power, power factor, and frequency on its 2.4-inch TFT color LCD screen. The device can also record historical data, set alarms and timers, and protect against output overloads. With its compact size and multiple plug and socket options, the Zhurui PR10-E is a versatile tool for measuring and managing electricity consumption.

Zhurui PR10-E is a power recorder that can measure and monitor power consumption of household appliances, factory equipment, and office devices. It displays various electrical parameters such as voltage, current, power, power factor, and frequency on its 2.4-inch TFT color LCD screen. The device can also record historical data, set alarms and timers, and protect against output overloads. With its compact size and multiple plug and socket options, the Zhurui PR10-E is a versatile tool for measuring and managing electricity consumption.

ZHURUI
User Manual
PR10-E
Power
Recorder
Shenzhen Zhurui Technology Co.,Ltd.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
2 / 13
Thank you for purchasing this ZHURUI "PR10 Power Recorder". To get the
maximum performance from the unit, please read this manual first, and keep this at
hand.
Packing Lists
1.PR10 Power Recorder ……………………………………………………………………………………………………………1 Set
2.User Manual ………………………………………………………………………………………………………………1 Copy
3.Warranty Card …………………………………………………………………………………………………………………1 Copy
4.Product Certification ………………………………………………………………………………………………………1 Copy
If the machine fails, do not open the machine and
replace the parts
yourself, so as to avoid electric shock
accident.
There is no replace parts inside of this
machine
. Please contact the manufacturer or
authorized dealer after failure.
The manufacturer
disclaims all
responsibility for any accident or injury.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
3 / 13
Product Overview
PR10 Power Recorder is displayed by 2.4 inch TFT color LCD, and it can measuring a variety of electrical equipment ’s power, power factor, voltage, current,
frequency, accumulated electricity consumption, accumulated electricity bill, accumulated electricity time, one shot electricity consumption, one shot electricity
bill and one shot electricity time. Daily use of electricity and electricity bill will be recorded, you can see the form of a chart or list of historical records. PR10 is
suitable for the measuring and monitor power consumption of the household, factory, office and other cases, and can be used to power on or power off a
various electric equipment according your setting.
Main Features:
The full digital operation and control.
2.4 - inch true color TFT LCD display.
0.5FS - level measuring accuracy.
8 Languages UI can freely to be chosen.
23 currency units can be set freely.
Four operation keys.
Date and time can be set, 5 date formats are supported.
After power on, the outlet can be set to automatic power on, no electricity, or maintain the working state of the last working.
Power statistics have two types: cumulative electricity and one shot electricity, one shot electricity can be cleared, it is convenient for the
measurement of electric charges in specific situations.
There are three main display pages: the overview page, the one shot electrical page and real-time electrical parameters page, the default page is
overview page, users can press key to switch different display page;
Automatic record historical data, which can be review in the form of a list or chart, and can be stored for up to 30 years.
Charge rates can be set up to 4 decimal places, the number of decimal places can be adjusted freely, support 8 time sections of sub billing function,
can be easily used for peak load billing occasions.
There are 9 timers, two are advanced timers, which can be set to power on or power off the power supply in the specific time on “no repeated”,
everyday , working dayor weekend, and other 7 timers are general timers can be set to open or close the power supply on the certain period
of time in one day.
It has alarm function and can be set to alarm when the voltage, current, power or temperature exceeds alarm settings.
It has output protection function and can be set to cut off the power supply when the voltage, current, power or temperature exceeds output
protection value. The “Launch overloadmode can be set when the current is 2A or above. No current and power are detected whether exceeds
the setting or not within 15 seconds when the “Launch overload is checked. It also has automatic recovery function. When Auto Recovery is
checked, if the machine is in output protection mode, 1 minutes later the power supply will be turned on automatically, if the power, voltage,
current or temperature exceed the output protection value, it will restart the output protection again, and the power supply will not powered on.
Energy-saving setting: it can be set to turn off the screen automatically without operation in 1 minute, 5 minutes or 10 minutes, it also can be set
not to turn off the screen. The measurement function continues after the screen is closed, press any key to turn on the screen.
The total power consumption and historical records can be cleared or do the factory restore in the system setting page.
Power resolution switch automatically according to the measurement results, when less than 100W it display two decimal places, when greater
than 100W it display one decimal, when greater than 1000W there’s no decimal display.
Over range hint.
6 different forms of plug and socket optional, respectively, for the new GB 10A, GB 16A, EU 16A, FR 16A, American 15A, BS 13A.
Small size, beautiful appearance, easy to carry, suitable for all kinds of electrical equipment for measurement.
Function Lists
Function Function Function
Power Measuring Time and Date Display 2
Advanced Timers
Voltage Measuring Five Date Format 7 General Timers
Current Measuring History Record Time and Date Setting
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
4 / 13
Power Factor Measuring Record View by Annual Charts Alarm
Frequency Measuring Record View by Annual Lists Output Protect
Accumulated Electricity Consumption Record View by Monthly Charts Switch State Can Be Setting
Accumulated Electricity Bill Record View by Monthly Lists Screen Power Saving
Accumulated Electricity Time Charge Rate Setting History Record Clearing
One Shot Electricity Consumption Segment Charging Function Accumulated Electricity Clearing
One Shot Electricity Bill 8 Languages Factory Reset
One Shot Electricity Time 23 Currency Units Help
supported Functions
Technical index
Electrical parameter measurement
Parameter Measure range Resolution Measuring accuracy
Voltage AC85~265v[1] 0.1v ±(0.5FS+0.1v)
Power 0.1~3750w[2] 0.01w[3] ±(0.5FS+0.01w) [3]
Current 0.005~15A[1] 0.001A ±(0.5FS+0.001A)
Power factor 0~1.000 0.001 ±(0.5FS+0.001)
Frequency 45~65Hz 0.1Hz ±(0.5FS+0.1Hz)
Electricity bill 0~999999 0.01 [4] ±(0.5FS+0.01) [4]
Electricity consumption 0~999999kwh 0.00001kwh[5] ±(0.5FS+0.00001kwh) [5]
Note: [1].Voltage and current measurements are true rms value;
[2].Power measurement is active power;
[3].If power <100w, the resolution is 0.01w, the measuring accuracy is
±
(0.5FS+0.01w),power>100w, the resolution is 0.1w, the measuring accuracy is
±
(0.5FS+0.1w),the power> 1000w, the resolution is 1w, the measuring accuracy
±
(0.5FS+1w);
[4].If Electricity bill<10000,the resolution is 0.01, the measuring accuracy is
±
(0.5FS+0.01), Electricity bill >=10000, the resolution is 0.1, the
measuring accuracy is
±
(0.5FS+0.1), Electricity bill >100000, the resolution is 1, the measuring accuracy is
±
(0.5FS+1);
[5]. The resolution of Electricity consumption is adjusted with the measurement results, the highest one is 0.00001kwh
Timing index
Timing range 999 days 23 hours 59 minutes
Timing resolution 1 minutes
Currency unit maintained
Currency name CNY TWD USD EUR GBP JPY RUB INR
Currency symbols $ £ ¥ руб Rs.
Currency name KRW TRY THB PHP IDR MYR ZAR AED
Currency symbols ฿ Rp RM R إ.د
Currency name SAR ILS CHF DKK UAH BRL Common
Currency symbols ل ا
Fr kr R$ ¤
Other indicators
Operating voltage AC85~265V Operating frequency 45~65Hz
Temperature 0~40 Humidity 90%RH
Size (length x width x
height)
125mmx79mmx38.5mm(the height does not contain the plugs), Weight 180g
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
5 / 13
PR10 Exterior
PR10-E Front PR10-E Back
Interfaces
Home page
Overview Page One Shot Page Real-time Parameters Page
Status bar icons
WarningThe icon flashes when there is an alarm event;
Timer: The icon appears in the status bar when the timer is turned on.
Output power off: The icon appears in the status bar when the outlet is powered off.
Output power on: The icon appears in the status bar when the outlet is powered on.
Home page 1: The icon appears in the status bar when the machine is in overview page.
Home page 2: The icon appears in the status bar when the machine is in one shot page.
Home page 3: The icon appears in the status bar when the machine is in real-time parameters page.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
6 / 13
Key Functions
Keys Function
In Main page In Setting page
Press this key to show the
System Menu.
If confront digits to confirm the number, then jump to next setting, if confront checkbox to check or
not check, if confront radiobox to check the radiobox or not where the cursor on, and jump to next
setting, then confirm it.
Long press this key to power
on or power off the outlets.
If confront digits to reduce the value where the cursor on, if confront the checkbox, radiobox or
button to jump to the previews setting.
Press this key to switch the
main
page, long press it to
show the serial number of this
machine.
If confront digits to increase the value where the cursor is, if confront the checkbox, radiobox or
button to jump to the next setting.
Press this key to clear one shot
electricity consumption, one
shot electricity bill and one
shot elapse time.
Press this key to quit the settings without any changes.
View history
1. Press key in operating state, to pop up system menu;
2. Press key to select “Historytem, now “Historyis white letters on blue;
3. Press key to pop up history menu;
4. Press key or key to select “Month-Chart”,Month-List”, Yea r -Chartor “Year-Listitem.
5. Press key again to enter the history records pages.
History Records Pages
Month-Chart Month-List
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
7 / 13
Year-Chart Year-List
Function Settings
Process of entering into setting page.
Function settings in detail
Set languages
1. Press ” key in main pages, to pop up the main menu.
2. Press ” key to select the menu item that needed, now the item is
white letters on blue.
3. If the item have submenu, press key to pop up the submenu, then
select the submenu item and press ” key to enter into the setting page,
if no submenu, press key to enter into the setting page.
1. See the Process of entering into setting pages”, enter the language setting page.
2. Press key or key to move the cursor to the language which is
needed.
3. Press ” key to set language which is needed.
4. Press key to move the cursor to the OKbutton, then press key
to save the settings and quit. Press key to quit without any changes.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
8 / 13
Currency settings
Charge rate settings
1. See the Process of entering into setting pages”, select the "General " sub item,
enter the charge rate setting page;
2. Press ” key to move the cursor to the “Enable segment charge” checkbox,
if want to charge with time division (e.g. charge the peak-valley electricity charge
rates), press key to check this checkbox, if not need the segment
charging, please do not check this checkbox;
3. Press key to move the cursor to the “Decimal digits” checkbox, then
press key or key to set the decimal digits;
4. Press key, if “Enable segment charge” checkbox is checked, then jump to
the OKbutton, press key again to set the segment charge rates, do as
the step 7. If Enable segment charge” checkbox not checked, then set the
charge rate, press key or key to set the charge rate, press
key to jump to the next digit, then press key to confirm it .
5. Press key to move the cursor to the OKbutton, press key t o
keep the setting and quit. Press Return/Clearto save the settings and quit.
6. If “Enable segment charge” checkbox is checked, then need to set the charge rate
of segment charging, according to the “Process of entering into setting pages,
select SegX(X=1~8) submenu item, enter into the setting page of the charge
rate of segment charging;
7. Use key, key, and ” key to set the time segment and
charge rate;
8. If needed, can do the settings in the previews segment or next segment, or press
key to move the cursor to the “OK” button, press key to save
the settings and quit. Press key to quit without any changes.
1. See the Process of entering into setting pages”, enter the currency setting page;
2. Press key or key to move the cursor to the currency which is
needed;
3. Press ” key to set the currency which is needed;
4. Press key to move the cursor to the “OK” button, then press key
to save the settings and quit. Press key to quit without any changes.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
9 / 13
The date formats setting
The time setting
Setting the timing (Advanced timer (timer 1,timer 2) setting )
1. See the Process of entering into setting pages, enter the date format setting
page;
2. Press key or key to select the needed date formats;
3. Press ” key to move the cursor to the “OK” button, press key to
save the settings and quit. Press key to quit without any changes.
1. See the Process of entering into setting pages”, select timer1 or timer2
submenu item and enter the advanced timer setting page.
2. Press ” key to set the timer, now the “Enabled” checkbox is blue;
3. Press key to check or uncheck this checkbox, then press key
to set the start time of the timer;
4. Use key, key and key to set the start time of the
timer.
5. Press key or key to select the time option of the timer, then
press key to complete time option setting, the time has 4 options:
"Not repeated", "Every day", "Work day" and "Weekend", "Not repeated"
means the machine will power on or power off on the date and time of
setting, "Every day" means no matter which date, the machine will power on
or power off at the setting time, "Work day" means it will do from Monday to
Friday, "Weekend" means it will do only on Saturday and Sunday;
6. Press key or key to select outlet state when the time
reached, press key to complete outlet state setting, now the cursor
jump to the OKbutton.
7. Press ” key to save the settings and quit. Press ” key to quit
without any changes.
1. See the Process of entering into setting pages”, enter the time setting page;
2. Press key to set the time, now the tenth of Year is white letters on
blue;
3. Press key or key to adjust the value, then press key
to achieve the adjustment and enter the next step;
4. Continue to set as the step 3, until to adjust the time;
5. At last press key to move the cursor to the OK button, press
key to save the settings and quit. Press key to quit without
any changes.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
10 / 13
Timer setting ( common timer(timers 3-9)setting)
Switch settings
Alarm settings
1. See the Process of entering into setting pages, enter the alarm setting page.
2. Press key to set the alarm, now the hundreds place of Voltage is white
words on blue background.
3. Use key, “ key, and key to set the alarm value of
voltage, now the cursor jump to the “Enabled” checkbox of voltage.
4. Press key to set voltage alarm or not, then press key to the
current alarm setting.
5. Repeat step 3 and step 4 until all items are set, now the cursor jump to the
OKbutton.
6. Press ” key to save the settings and quit. Press ” key to quit
without any changes.
1. See the Process of entering into setting pages”, select timer3 to timer9
submenu item and enter the general timer setting page.
2. Press ” key to set the timer, now the “Enabled” checkbox is blue.
3. Press ” key to check or uncheck this checkbox, then press key ,
key and key to set the start time and outlet state of the timer;
4. Next set the time and outlet state of the Second groups.
5. Set the outlet state is whether repeated everyday or not, if needed to do the
action of the group timer everyday, please check “Everyday checkbox, if not
needed, please don’t check this checkbox. If the “Everyday” checkbox is not
checked, then it will turn off this timer after the second group timer
performed.
6. At last press key to move the cursor to the OK button, press
key to save the settings and quit. Press key to quit without
any changes.
1. See the Process of entering into setting pages, enter the outlet setting page.
2. Press key or key to move the cursor to item needed, On
means it automatically power on the outlet and begin to supply electricity to
the electrical equipment after the machine start up; Off means it power off
the outlet after the machine start up, unless press more than 3
seconds to power on the outlet , “Same as last time means the machine will
remember the last outlet states, and will set the outlet state same as last time
after the machine start up.
3. Press key to move the cursor to the OK button, press key to
save the settings and quit. Press key to quit without any changes.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
11 / 13
Output protection settings
Screen setting
System settings (Clear accumulated electricity consumption, clear history recording , restore the factory settings)
1. See the Process of entering into setting pages”, enter the Output Protect
setting page.
2. According to the alarm settings, complete the output protection parameter
settings of voltage, current, power and temperature.
3. If needed, press key to check or uncheck the “Launch overload”
checkbox, press key to jump to next setting item. If the start-up
current of the equipment test (e.g. the motor) exceed the output protection
current, then the “Launch overload” checkbox need to be checked, if this
checkbox is checked, the machine will not monitor the output current and
power exceed the max current and power limit which was set before, “Launch
overloadwill not take effect when the load current less than 2A.
4. If needed, press key to check or uncheck the “Auto Recovery
checkbox, press key to move the cursor to the “OK” button; if this
checkbox is checked, when the machine is in output protection and power off
the outlets, one minute later if the voltage, current, power or temperature of
the machine are not in the output protection limits, the machine will
automatically power on the outlets to the test equipment.
5. Press ” key to save the settings and quit. Press ” key to quit
without any changes.
1. See the Process of entering into setting pages”, enter the screen setting page.
2. Press key or key to adjust the time option for turn off the
screen, press key to select the option, now the cursor jump to the
OK” button.
3. Press ” key to save the settings and quit. Press ” key to quit
without any changes.
1. See the Process of entering into setting pages”, enter the system setting page.
2. Press key or key to move the cursor to the item need
operation, then press key, the confirm dialog will pop up at this time.
3. Press ” key or key to decide whether to perform the operation
or not, press key to perform, press key to quit and not perform
this operation.
4. Pease use this function cautiously, especially Factory Reset will clear all the
records.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
12 / 13
Enter the help page
*During setting, long press key or key can achieve rapid adjustment
Frequently Asked Questions
Number Problems Solutions
1 After startup, outlet is powered off, icon in the
bottom right corner of screen doesnt change to Icon.
Long press key for 3 seconds to turn on the power, or enter “switch
settings” page, set the switch state to “On”, the machine will power on the outlet
automatically after startup.
2 Outlet is powered off during working, icon appears or
blinks, or icon blinks.
The machine is in output protection. Check whether the voltage, current, power or
temperature exceed the output protection limit or not, if needed, modify the output
protection limit or cancel it or checked “Launch overload” checkbox.
3 The machine give out alarm sound when working, the
icon on the lower right corner of screen blinks.
The machine is in alarm status. Check whether the voltage, current, power or
temperature exceed the alarm limit, if needed, modify the alarm settings or cancel it.
4 After power off, the time and the total power consumption
are not saved.
Built-in button cell has run out, now it needs to replace a new button cell, the
battery model is CR2032.
Considerations
1. The machine cannot works in hot and humid environment, please use it in normal temperature and humidity.
2. The working voltage of the machine is AC85V~AC265V.
3. The working current cannot be greater than the maximum operating current.
4. Do not let the machine expose to the dust, corrosive gases or other harmful substances in the environment when use and keep.
5. Do not touch the plug of the machine when using, or you will get an electric shock.
6. If the machine failed working, don not open the machine and replace parts by yourself to avoid electric shock, please contact the manufacturer.
1. See the Process of entering into setting pages”, enter the help page.
2. The help page has some prompt of simple operation.
ZHURUI
Shenzhen Zhurui Technology Co.,Ltd.
13 / 13
Legal Notices
All Rights Reserved © Shenzhen Zhurui Technology Co., Ltd. 2016.
Without permission of Shenzhen Zhurui Technology Co., Ltd. any unit or individual will not be allowed to extract, copy parts or all of this manual and
transmit in any form. The product described by this manual may contain the copyright of the hardware and software of Shenzhen Zhurui Technology Co., Ltd.
and it may exist license, unless with the written permission of related rights, otherwise, any person cannot be allowed to copy, distribute, copy board,
decompile, disassemble, decrypt, reverse engineer, lease, transfer and do other violations with the aforementioned hardware and software in any form.
Within the limits permitted by applicable law, Shenzhen Zhurui Technology Co., Ltd. can modify the contents of this manual in any case.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Zhurui PR10-E User manual

Type
User manual

Zhurui PR10-E is a power recorder that can measure and monitor power consumption of household appliances, factory equipment, and office devices. It displays various electrical parameters such as voltage, current, power, power factor, and frequency on its 2.4-inch TFT color LCD screen. The device can also record historical data, set alarms and timers, and protect against output overloads. With its compact size and multiple plug and socket options, the Zhurui PR10-E is a versatile tool for measuring and managing electricity consumption.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI