American Standard 2425.XXXW SERIES, 2425.XXXW, Hampton 2425.XXXW SERIES User manual

  • Hello! I am an AI chatbot trained to assist you with the American Standard 2425.XXXW SERIES User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION INSTRUCTIONS
753457-100 REV. B
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
HAMPTON
5' x 32"™
DROP-IN
WHIRLPOOL
2425.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Tile Bead Kit 751755-100*
• Safe-T-Heater 9075.120*
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
GENERAL SPECIFICATIONS FOR 2425 WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP 1.6 HP, 9.7 AMPS,120V.
60 x 32 x 21-1/2 (1524 x 813 x 546mm)
115 Lbs. (52 Kg.)
574 Lbs. (258 Kg.)
55 Gal. (208 L.)
45 Gal. (171 L.)
16-1/4 x 38-1/4 (413 x 972mm)
26-1/4 x 52-1/2 (667 x 1334mm)
15 (381mm)
43 Lbs./Sq.Ft. (208 Kgs./Sq.m)
15.6
35.3
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
19-1/2
(495mm)
21-1/2
(546mm)
1-1/2 O.D.TAILPIECE
INTEGRAL
FEET
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
FINISHED
WALL
60
(1524mm)
32
(813mm)
16
(406mm)
10-1/4
(260mm)
12
(305mm)
3
(76mm)
(8) JETS
3-1/2
(89mm)
2
(51mm)
CUTOUT IN FLOOR FOR DRAIN
PUMP
FINISHED
WALL
12
(305mm) OPT.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65 & 78
(1651 & 1981mm)
C/L OF
OVERFLOW
4
(102mm)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
2-3/4
(70mm)
4-5/8
(117mm)
1-1/2 N.P.T.M.
THREADS
3/4
(19mm)
9
(229 mm)
C/L OF
SUPPLIES
C/L OF DRAIN
SEE FITTING
SPECS FOR
DIMENSIONS
(2) AIR VALVES
ON/OFF
SWITCH
PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
UNDERSIDE
OF DECK
SAFE-T-HEATER
REMOVABLE
BLANK
OUTLINE OF CUTOUT
58-1/2 X 30-1/2
(1486 X 775mm)
753457-100 REV. B
(2)
495mm
(19-1/2)
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 1 x 3 stringer to the studs, with the top of the stringer touching the traced line.
3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
TILE
TILE
BEAD
STRIP
LEVELING
STRINGER
BATH
ADHESIVE
SEALANT
WALLBOARD
NOTE: Tile bead kit not included and must be
purchased separately.
FIG. 1
TYPICAL RECESS INSTALLATION
LEVELING
SURFACE
WATERPROOF
SEALANT
BATH
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
775mm
(30-1/2)
CUTOUT
AS
DESIRED
1486mm
(58-1/2)
CUTOUT
495mm
(19-1/2)
ACCESS PANEL
610mm
(24)
305mm
(12)
610 mm
(24)
305mm
(12)
495mm
(19-1/2)
1527mm
(60-1/8)
762mm
(30)
813mm
(32)
TUB WIDTH
LEVELING
STRINGERS
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BLACK
WHITE
120 VAC
GND.
SEPARATE
15 AMP GFCI
OUTLET
WHIRLPOOL MOUNTED
AIR SWITCH OR
WALL TIMER
ELECTRICAL INSTALLATION
PUMP/MOTOR
753457-100 REV. B
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the
electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A
SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.
(3)
WIRE SELECTION GUIDE
753457-100 REV. B
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings
are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or
stains may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing
with a white automotive-type polishing compound and waxing with a liquid wax.
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Motor
Hi Performance
Rating
50' 100'
120V Power Line
150' 200'
12 12 10 8
(4)
SPIC AND SPAN
®
IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
1.6
/