LG LW1013ER Owner's manual

Type
Owner's manual

LG LW1013ER is a compact, yet powerful air conditioner that will efficiently cool your room up to 406 sq. ft. It features 3 cooling and fan speeds, allowing you to customize your comfort level. Additionally, it includes an energy-saving mode that can be used while sleeping, raising the temperature 1 degree Celsius after 30 minutes and again after another 30 minutes to save energy.

LG LW1013ER is a compact, yet powerful air conditioner that will efficiently cool your room up to 406 sq. ft. It features 3 cooling and fan speeds, allowing you to customize your comfort level. Additionally, it includes an energy-saving mode that can be used while sleeping, raising the temperature 1 degree Celsius after 30 minutes and again after another 30 minutes to save energy.

AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
P/NO:MFL67781904
www.LG.com
CLIMATISEUR DE PIÈCE
MFL67781904
MODELMODÈLE:LW1013ER
FRANÇAIS
OWNER’S MANUAL
GUIDE D’UTILISATION
S'il vous plaît lisez attentivement ce manuel avant d'utiliser
votre appareil et le conserver pour référence future.
23
Do not operate the air conditioner if
you smell gas.
Do not operate the air conditioner if
you smell gas.
For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of product, fire, or electronic shock.
13
15
11
14
12
10
9
7
1. CABINET
2. FRONT GRILLE
3. AIR FILTER
4. AIR INTAKE (INLET GRILLE)
5. AIR DISCHARGE
6. VERTICAL AIR DEFLECTOR
(HORIZONTAL LOUVER)
7. EVAPORATOR
8. HORIZONTAL AIR DEFLECTOR
(VERTICAL LOUVER)
9. CONTROL PANEL
10. POWER CORD
11. COMPRESSOR
12. BASE PAN
13. BRACE
14. CONDENSER
15. REMOTE CONTROLLER(OPTIONAL)
4
6
5
8
1
2
3
Use of adapter plugs not pemitted in Canada.
H
84
406
1
2
POWER
Operation starts when this button is pressed and stops when you
press the button again.
FAN SPEED SELECTOR
For increased power while cooling,select a higher fan speed.
3 steps:High
LowMed.
ON/OFF TIMER
The Timer can be set to start and stop the unit in hourly increments
up to 24 hours
You will usually use shut-off time while you sleep.
For your sleeping comfortonce timer is set the temperature setting will
raise 1 C
after 30min and once again after another 30min.
OPERATION MODE SELECTOR
Energy Saver:
Approximately every 3 minutes the fan will turn on
and check the room air tedetermine of cooling is need.
The fan stops when the compressor stops cooling.
C
Temp
Fan Speed
Timer Mode
1
2
4
3
5
Select dry mode for dry operation.
Drydry model is used to remove humidity from the room without additional cooling.
Once the set temperature is reachedthe compressor and circulation fan turns off.
Fan speed is pre-set and cannot be adjusted.
TEMPERATURE CONTROL
The thermostat monitors room temperature to maintain the desired temperature.
The thermostat can be set between 16
The unit takes an average of 30 minutes to adjust the room temperature by 1 C.
C~30 C.
REMOTE CONTROL SENSOR
CAUTION
The Remote Controller will not function properly if strong light strikes the sensor window
of the air conditioner or if there are obstacles between the Remote Controller and the air
conditioner.
y
one
battery
the
battery is
battery
battery
VENTCLOSE
OPEN
Vent Control
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation.
OPEN the vent to discharge stale air.
NOTICE
Adjusting horizontal air flow Adjusting vertical air flow
Adjusting Horizontal Air Flow Direction
Adjusting the vertical louvers left and right will
change horizontal airflow.
Adjusting Vertical Air Flow Direction
Adjusting the horizontal vane up and down will
change vertical airflow. The vane can be adjusted
by nudging the vane backward or forward.
Adjusting the Air Flow Direction
ENGLISH
Operating Instructions
Adjusting the Air Flow Direction
Recommended orientation of louvers
Adjust louvers to face upwards when cooling to maximize cooling efficiency.
Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the
cooling efficiency of the air conditioner.
Before using the ventilation feature, position the
vent lever by pulling Part A out straight and
snapping it into place.
below
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49

LG LW1013ER Owner's manual

Type
Owner's manual

LG LW1013ER is a compact, yet powerful air conditioner that will efficiently cool your room up to 406 sq. ft. It features 3 cooling and fan speeds, allowing you to customize your comfort level. Additionally, it includes an energy-saving mode that can be used while sleeping, raising the temperature 1 degree Celsius after 30 minutes and again after another 30 minutes to save energy.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages