K-100 Series • Updated 8-10 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
K-100 Series Technical Specifications
Water Specifications
Incoming water line size................................................................................... 1/2” NPT
Recommended water hardness...................................................... 1-6 grains/U.S. gal.
Consumption at 100% capacity: ............................... 105.0 U.S. gals. (397.5 liters)/hr.
0.37 U.S. gals. (1.40 liters)/rack
Final rinse flow pressure .........................................................15-25 PSI (1.0-1.7 bars)
Flow rate ...................................................................... 1.75 U.S. gals.(6.62 liters)/min.
Venting Specifications
Load end .................................................................................... 200 CFM (336m
3
/h)
Unload end................................................................................. 350 CFM (588m
3
/h)
Total .......................................................................................... 550 CFM (924m
3
/h)
Shipping Information
K-100E, K-100S:
Machine weight........................................................................... 979 lbs. (444kg)
Shipping weight ....................................................................... 1,097 lbs. (498kg)
Crating (LxWxH) ...........................................10’ 3” x 3’ x 6’ 3” (3.1 x 0.9 x 1.9m)
192.2 cu. ft. (5.4m
3
)
K-100ET, K-100ST:
Machine weight........................................................................ 1,099 lbs. (499kg)
Shipping weight ....................................................................... 1,217 lbs. (553kg)
Crating (LxWxH) .........................................10’ 3” x 3’ x 6’ 11” (3.1 x 0.9 x 2.1m)
212.7 cu. ft. (6.0m
3
)
Operating Capacities (NSF Rated)
Racks per hour......................................................................................................284
Dishes per hour .................................................................................................7,100
Glasses per hour ............................................................................................ 10,224
Conveyor Specifications
Conveyor belt speed ..................................................... 7.91 feet/min. (2.41m/min.)
Horizontal clearance..................................................................... 1’ 8-1/2” (520mm)
Vertical clearance (K-100E, K-100S).................................................. 1’ 6” (457mm)
Vertical clearance (K-100ET, K-100ST) .............................................2’ 2” (660mm)
Minimum water temperatures:
Prewash tank ......................................................................110-140°F (43-60°C)
Wash tank ....................................................................................... 150°F (66°C)
Recirculating rinse tank.................................................................. 160°F (72°C)
Final rinse........................................................................................ 180°F (82°C)
Minimum incoming water temperature:
Machines without internal booster ................................................. 180°F (82°C)
Machines with internal booster ............................. 110° or 140°F (43° or 60°C)
Initial fill ........................................................................ 69.5 U.S. gals. (263.1 liters)
Prewash tank capacity ........................................... 28.5 U.S. gals. (107.9 liters)
Wash tank capacity................................................... 20.5 U.S. gals. (77.6 liters)
Recirculating rinse tank capacity ............................. 20.5 U.S. gals. (77.6 liters)
Electrical Specifications
Internal booster heater Rating, Rating, Peak Minimum Maximum
supply connection machine machine current supply circuit breaker/
startup operation draw ampacity disconnect
40°F rise electric booster (140°F/60°C water supply temperature)
208V/60 Hz/3 Ph 14.4 kW 9.6 kW 40.0 A 50 A 50 A
230V/60 Hz/3 Ph 14.4 kW 9.6 kW 36.1 A 50 A 50 A
460V/60 Hz/3 Ph 14.4 kW 9.6 kW 18.1 A 25 A 25 A
70°F rise electric booster (110°F/43°C water supply temperature)
208V/60 Hz/3 Ph 28.8 kW 21.6 kW 79.9 A 100 A 100 A
230V/60 Hz/3 Ph 28.8 kW 21.6 kW 72.3 A 100 A 100 A
460V/60 Hz/3 Ph 28.8 kW 21.6 kW 36.1 A 50 A 50 A
Electric tank heater ratings (K-100E, K-100ET)
208V/60Hz/3Ph 230V/60Hz/3Ph 460V/60Hz/3Ph
Wash tank 15.0 kW 14.6 kW 15.0 kW
Recirculating rinse tank 9.0 kW 8.8 kW 9.0 kW
Machine supply Peak Minimum Maximum
connection current supply circuit breaker/
draw ampacity disconnect
K-100E, K-100ET (standard height and tall hood, electric tank heat)
208V/60 Hz/3 Ph 94.2 A 125 A 125 A
230V/60 Hz/3 Ph 86.0 A 110 A 110 A
460V/60 Hz/3 Ph 42.1 A 60 A 60 A
K-100S, K-100ST (standard height and tall hood, steam coil tank heat)
208V/60 Hz/3 Ph 27.5 A 35 A 35 A
230V/60 Hz/3 Ph 27.5 A 35 A 35 A
460V/60 Hz/3 Ph 12.0 A 15 A 15 A
External Booster Heater Recommendations (for machines without
optional internal booster heater)
Booster ratings are based on peak capacity of 105.0 U.S. gals/hr. and a flow rate of
1.75 U.S. gals./min. Recommended boosters are one size larger than required to help
compensate for any local conditions that may prevent full performance.
Water supply Required Recommended
temperature temperature rise booster rating
110°F/43°C ................................ 70°F/39°C........................................ 24 kW
140°F/60°C ................................ 40°F/22°C........................................ 12 kW
Steam Specifications (K-100S, K-100ST)
Steam line connection ...................................................................................... 3/4” NPT
Condensate return connection......................................................................... 3/4” NPT
Steam pressure ........................................................................ 10-30 psi (0.7-2.0 bars)
Consumption:...................................................................................................60 lbs./hr.
Internal Steam Booster Heater:
40°F rise steam booster (140°F/60°C water supply temperature) .........50 lbs./hr.
70°F rise steam booster (110°F/43°C water supply temperature)........100 lbs./hr.
Note: All specifications are subject to change without notice
based on MEIKO’s dedicated product improvement program.
Prewash pump motor ............................................................................................3.0 hp
Wash pump motor .................................................................................................3.0 hp
Recirculating rinse pump motor ............................................................................3.0 hp
Conveyor motor ................................................................................................ 0.125 hp