GROHE 19376000 is a concealed thermostat mixer that allows you to precisely control the temperature of your water. It features a safety stop that limits the temperature to 100 °F, preventing scalding. The flow rate is limited by the economy stop, which can be overridden by depressing the button on the flow control knob. The thermostat knob has a temperature scale, allowing you to easily set the desired temperature. The unit is easy to install and maintain, with all parts accessible for cleaning and replacement if necessary.

GROHE 19376000 is a concealed thermostat mixer that allows you to precisely control the temperature of your water. It features a safety stop that limits the temperature to 100 °F, preventing scalding. The flow rate is limited by the economy stop, which can be overridden by depressing the button on the flow control knob. The thermostat knob has a temperature scale, allowing you to easily set the desired temperature. The unit is easy to install and maintain, with all parts accessible for cleaning and replacement if necessary.

D
.....1
NL
.....6
PL
.....11
P
.....16
BG
.....21
CN
.....26
GB
.....2
S
.....7
UAE
.....12
TR
.....17
EST
.....22
UA
.....27
F
.....3
DK
.....8
GR
.....13
SK
.....18
LV
.....23
RUS
.....28
E
.....4
N
.....9
CZ
.....14
SLO
.....19
LT
.....24
I
.....5
FIN
...10
H
.....15
HR
.....20
RO
.....25
DESIGN + ENGINEERING
GROHE GERMANY
www.grohe.com
19 304
ALLURE
96.173.031/ÄM 228507/07.14
D
.....1
NL
.....2
PL
.....4
P
.....6
BG
.....7
CN
.....9
GB
.....1
S
.....3
UAE
.....4
TR
.....6
EST
.....8
UA
.....9
F
.....1
DK
.....3
GR
.....5
SK
.....6
LV
.....8
RUS
...10
E
.....2
N
.....3
CZ
.....5
SLO
.....7
LT
.....8
I
.....2
FIN
.....4
H
.....5
HR
.....7
RO
.....9
English .....1
Français .....2
Español .....3
I
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
1
B
A
E
3
F
F1
4
K
G1
G
G2
2
A
D
C
C1
D1
J
H
5
M
L
P
N
O
7
min.
max.
H
6
1
English
Installation
- Remove the mounting template, see fold-out page I, Fig. [1].
- Remove clip (A) and pull off stop ring (B).
- Install stop ring (C) supplied so that mark (C1) is at right, fit
clip (A), sleeve (D) and scale ring (D1), see Fig. [2].
- Install holder (E) and fit sleeve (F) and scale ring (F1), see
Fig. [3].
- Grease the seals (G1) for the escutcheon mounting
bracket (G2) with the special grease supplied and install
escutcheon mounting bracket (G2) with mounting set (K),
see Fig. [4].
- Fit the escutcheon (G).
If the thermostat has been installed at too great a depth,
this can be adjusted by 1 1/16“ with an extension set (see fold-
out page II, Prod. No. 47 653).
Installation of the flow control knob and adjustment of the
economy stop, see fold-out page I, Figs. [5] to [7].
The flow rate is limited by the economy stop (H) supplied,
see Fig. [5].
To install the flow control knob, proceed as follows:
1.Close the ceramic headpart (J) by turning clockwise.
2.Install the economy stop (H) in the desired position.
For possible settings, see Fig. [6].
3.Fit splined adapter (L), see Fig. [7].
4.Install flow control knob (M) so that the button (N) is at top.
5.Screw in screw (O).
6.Fit cap (P).
If a higher rate is desired, the stop can be overridden by
depressing the button (N).
Adjustment
Installation of the thermostat knob and temperature
adjustment, see fold-out page III, Figs. [8] and [9].
Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat.
After any maintenance operation on the thermoelement.
1.Open the shutt-off valve and check the temperature of the
water with a thermometer, see Fig. [8].
2.Turn the adjusting nut (Q) clockwise or anticlockwise until
the water temperature reaches 100 °F.
3.Install temperature control handle (R) so that the button (V)
is at top, see Fig. [9].
4.Screw in screw (S).
5.Fit cap (T).
Reversed union (hot on right - cold on left).
Replace thermostatic cartridge (W), see replacement parts
fold-out page II, Prod. No.: 47 657 (1/2”).
Temperature limitation
The safety stop limits the temperature range to 100 °F .
If a higher temperature is desired, the 100 °F limit can be
overridden by depressing the button (V), see Fig. [9].
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be unscrewed and removed.
Maintenance
Inspect and clean all parts, replace if necessary and grease
with special valve grease.
Shut off cold and hot water supplies by closing both
isolation valves (W1), see fold-out page III, Fig. [10] and [11].
I.Thermoelement (W), see fold-out page III, Fig. [12].
Readjustment is necessary after every maintenance operation
on the thermoelement (see Adjustment).
Reassemble in reverse order.
The overload unit (Q1) must be screwed as far as possible in
the adjusting nut (left-hand thread) (Q).
Install stop ring (C) so that mark (C1) is at right.
II. Non-return valve (X) or (X1), see fold-out page III,
Fig. [13].
Reassemble in reverse order.
III. Ceramic headpart (Z), see fold-out page III, Fig. [13].
Reassemble in reverse order.
Observe the correct mounting positions!
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
Be careful about the concealed mixer housing, see
fold-out page II.
2014/03/21
www.grohe.com
D
&
+49 571 3989 333
A
&
+43 1 68060
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
CDN
&
+1 888 6447643
CH
&
+41 448777300
CN
&
+86 21 63758878
CY
&
+357 22 465200
CZ
&
+420 277 004 190
DK
&
+45 44 656800
E
&
+34 93 3368850
EST
&
+372 6616354
F
&
+33 1 49972900
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
GR
&
+30 210 2712908
H
&
+36 1 2388045
HK
&
+852 2969 7067
I
&
+39 2 959401
IND
&
+91 124 4933000
IS
&
+354 515 4000
J
&
+81 3 32989730
KZ
&
+7 727 311 07 39
LT
&
+372 6616354
LV
&
+372 6616354
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
NL
&
+31 79 3680133
NZ
&
+09/373 4324
P
&
+351 234 529620
PL
&
+48 22 5432640
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
GroheTurkey@grome.com
UA
&
+38 44 5375273
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL
HR
KS
ME
MK
SLO
SRB
&
+385 1 2911470
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
IR
OM
UAE YEM
&
+971 4 3318070
Far East Area Sales Office:
&
+65 6311 3600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE 19376000 User manual

Type
User manual
This manual is also suitable for

GROHE 19376000 is a concealed thermostat mixer that allows you to precisely control the temperature of your water. It features a safety stop that limits the temperature to 100 °F, preventing scalding. The flow rate is limited by the economy stop, which can be overridden by depressing the button on the flow control knob. The thermostat knob has a temperature scale, allowing you to easily set the desired temperature. The unit is easy to install and maintain, with all parts accessible for cleaning and replacement if necessary.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI