ETC Source Four LED Series User manual

Type
User manual

ETC Source Four LED Series is a professional-grade LED lighting system that offers a wide range of features and capabilities to meet the demands of various lighting applications. With its advanced LED technology, it provides exceptional color rendering, energy efficiency, and long-lasting performance.

The Source Four LED Series is known for its versatility, allowing users to create a variety of lighting effects and ambiances. Its high output and precise control make it suitable for use in theaters, studios, concerts, and other entertainment venues. Additionally, its compact size and lightweight design make it easy to handle and transport.

ETC Source Four LED Series is a professional-grade LED lighting system that offers a wide range of features and capabilities to meet the demands of various lighting applications. With its advanced LED technology, it provides exceptional color rendering, energy efficiency, and long-lasting performance.

The Source Four LED Series is known for its versatility, allowing users to create a variety of lighting effects and ambiances. Its high output and precise control make it suitable for use in theaters, studios, concerts, and other entertainment venues. Additionally, its compact size and lightweight design make it easy to handle and transport.

USER’S GUIDE
Source Four CDM Gobo projector
with remote magnetic control gear
CONTENTS
Before you start 2
Mounting & connecting the remote control gear 3
Installing the lamp 4
Focussing the luminaire 4
Using colour filter 4
Lamp Replacement 5
Routine maintenance 5
Source Four CDM diagram 6
Warranty 7
Specifications 7
www.enliten.co.uk/manuals/S4CDM.pdf
Page 1
This page is left intentionally blank
Before you start
This package contains a Source Four CDM profile spotlight with remote (2m)magnetic control gear.
Ensure that you have the correct fixture (5°, 10°, 19°, 26°, 36°, 50°) this will be indicated on the carton.
In addition to the luminaire you will also have been supplied with;
Ensure that you have control gear to match the lamp wattage. Ensure that you have the correct colour temperature
lamp (see lamp replacement for further details)
Unpack & check for damage.
The Source Four CDM luminaire box should contain;
1 x Source Four CDM luminaire fitted with special lampholder assembly
1 x Hex Key
1 x Colour filter holder
If ordered with the fixture, other items including iris diaphragm, pattern holders and patterns may be included or
fitted. Please consult your box label and packing list for details.
Safety Information
This fixture is for professional use only. Read the entire manual before use.
Do not mount this fixture on or near a flammable surface
This fixture is for interior use only for exterior applications use Callisto Exterior spotlight
We recommend the use of a safety cable as a secondary suspension
Always ensure that the colour frame clip is left in the locked position
Always replace the lamp if it is damaged or thermally deformed or is slow to start
Keep luminaire 0.7m from any lighted object
Disconnect the luminaire from power before cleaning, maintenance or re-lamping
Maximum ambient temperature t
a
=45°C
Maximum surface temperature t
max
=180°C
70/150W Magneticremote control
gear to suit local supply voltage
and frequency
Philips mastercolour
70/150W CDM-T lamp
Page 2
WarrantyWarranty
Enliten warrants that the luminaire shall be free from manufacturing defects in materials and workmanship.
All luminaires are tested and inspected for damage prior to shipping.
Any claim under the warranty should be made to the dealer that supplied the equipment along with a copy of the invoice
and details of the problem. Should you be unable to get a satisfactory response from your dealer, or they are no longer
trading, please contact Enliten directly enclosing in addition, copies of any intermediate correspondence with your
dealer.
This warranty is a limited warranty and is given under English Law subject to the following (notwithstanding any statutory
requirements);
1. Enliten shall be under no liability in respect of any defect in the Goods arising from any drawing, design or
specification supplied by others
2. Enliten shall be under no liability in respect of any defect arising from fair wear and tear, wilful damage
negligence, abnormal working conditions, failure to follow Enliten’s instructions (whether oral or in writing),
misuse or alteration or repair of the Goods without Enliten’s written approval
3. Subject as expressly provided in these Conditions, and except where the Goods are sold under a consumer
sale (as defined by the UK Sale of Goods Act 1979), all warranties, conditions or other terms implied by
statute or common law are excluded to the fullest extent permitted by law.
4. Any claim which is based on any defect in the quality or conditions of the Goods shall (whether or not
delivery is refused by the Buyer) be notified to the dealer within 7 days from the date of delivery or where
the defect or failure was not apparent on reasonable inspection) within a reasonable time after discovery of
the defect or failure. If delivery is not refused, and the Buyer does not notify the dealer accordingly, the
Buyer shall not be entitled to reject the Goods and Enliten shall have no liability for such defect or failure
5. Except in respect of death or personal injury caused by Enliten’s negligence, Enliten shall not be liable to the
Buyer by reason of any representation, or any implied warranty, condition or other term or any duty at
common law, or under the express terms of the Contract, for any consequential loss or damage (whether for
loss of profit or otherwise), costs, expenses or other claims for consequential compensation whatsoever (and
whether caused by the negligence of Enliten, its employees or agents or otherwise) which arise out of or in
connection with the supply of the Goods or their use or resale by the Buyer, except as expressly provided in
these Conditions.
SpecificationsSpecifications;
Packed Size Max Voltage See control gear
Packed Weight Max Current See control gear
Lamp Type Philips CDM-T Minimum service interval 6 months
Lamp Wattage 70W or 150W Pattern Type B size glass or metal
Rated Lamp Life 9000hr Ballast Type To suit CDM-T
Lamp Base G12 IP Rating IP20
Special Tools Required Hex Key (supplied)
Conformity UL, CE EN60598
Page 7
Mounting and connecting the remote control gear
Mount
the fixture first in its final location. A number of mounting brackets are available from your dealer. We
recommend the use of a secondary suspension cable which is also available from your dealer in both black and
galvanised finish.
The Source Four CDM
is supplied with a 2m high voltage flex that must be connected to the remote encapsulated
control gear. If for any reason another control gear package is used, it must be of a type approved by Philips for use
with the CDM-T mastercolour lamp and must mee
t all local electrical codes. If in doubt, please contact Enliten for
advice.
Do not extend the luminaire flex
- it is a special high voltage cable type and the maximum permitted distance
between the fixture and remote encapsulated gear is 2m/6ft*
If
you must place the control gear more than 2m from the fixture, you should contact your dealer and upgrade the
control gear package to a 20m long range IP65 control gear package.
You should now securely mount the remote control gear in a suitable location
such that the luminaire flex will easily
reach the output terminals. The location must be ventilated to ensure that the ambient temperature does not rise
above 50°C.
You may now connect the luminaire to the control gear package
The installation and co
nnection of a Source Four CDM system to a mains supply should be carried out by a competent
electrician and all work should be carried out to local regulatory standards.
The connections are as follows;
Fixture to ballast
HT/Live Brown with white inner insulation
Neutral Blue with white inner insulation
Earth/Ground Green/Yellow
The Source Four CDM is a Class II (earthed) fixture and must be earthed/grounded even when connected to a Class I
(double insulated) control gear package.
Page 3
Source Four CDM DiagramSource Four CDM Diagram
Page 6
Use black wire to
select voltage
[230]
[250]
[240]
L
E
N
LA
230/240/250V
50Hz
N
E
L
Installing the lamp
Ensure that the power is isolated. Using the hex key provided, release the lampholder assembly and remove.
Without touching the glass envelope, push the lamp fully into the lampsocket ensuring that the reta
place.
Replace the lampholder assembly and tighten with the hex key.
Focussing the luminaire
Pull all of the shutter blades outwards to produce a circular beam. The beam may be focussed by releasing the focus
screw on the underside of the lens barrel and sliding the barrel backwards or forwards.
The beam may be shaped or masked by adjusting the shutter blades.
either the gobo slot or the iris slot.
Note: The correct gobo holder must be used. If one has not been supplied, contact your dealer for details.
If using the iris slot for either an Iris diaphragm or a gobo,
the slot cover must be opened. Release the two screws and
slide back the cover. Insert the accessory, close the cover as
far as it will travel and tighten the screws again with the
cover in the closed position. This retains the accessory within
the slot.
For fine adjustment of the gobo rotation, the entire front
barrel of the fixture may be rotated by releasing the
barrel rotation knob, and rotating the lens barrel.
Tighten the knob after use.
Using Colour Filters
There are three colour filter options available;
1. Use standard theatrical colour filter in the holder supplied
2. Use Devon Glass filter in the front colour runner
3. Use an 86mm or 100mm dichroic filter in a glass
gobo holder in the gobo or iris slot (not the same slot
as any other accessory)
Note that for 1 & 2, the filter holder must be secured by ensuring that the retaining clip is in the locked position.
Page 4
Lamp replacementLamp replacement
Approved lamp types;
Philips Mastercolour CDM-T lamp 150W 830 (3000K) or 942 (4000K) or 70W 830 (3000K) or 70W 942 (4000K)
The Philips 70W or 150W CDM-T 830 (
3000K) or 942 (4000K) lamp has a manufacturer’s rated life of 9000hrs. This is
a manufacturer’s rated life and is not a guaranteed life in real service. In practice it has been found that under
reasonable service conditions that this life expectancy is c
ommon. It has been noted that there may be a degradation
in light output over the life of the lamp, which can become noticeable after 6000hr. We do not currently recommend
the use of any other manufacturer’s lamp.
It is important to replace any lamp t
hat fails to ignite or begins to cycle (switching on and off continually). Although
the ballast (if using the recommended type) will have a thermal cut-
off and timed ignitor to protect against damage,
the life of the ignitor may be reduced.
We recommend a planned annual maintenance and lamp change. This should avoid the need for occasional lamp
changes. In addition, you should assess the risk of accidental and deliberate damage, and the conditions under which
these fixtures are used, and plan additional maintenance as this risk assessment requires. It is often a statutory
requirement to keep a written record of your risk assessment and the measures employed.
The Philips CDM ceramic metal halide lamp has excellent colour rendering for a metal halide lam
p. The lamp will
reach its optimum output and stability after 100 hrs use. Before this time there may be a variation in colour
temperature and output. These phenomena may also occur when the position of the fixture is changed.
These effects are more noticeable with the 3000K 830 lamp types.
For installation of the lamp, please see the section Installing the Lamp above
Routine Maintenance Routine Maintenance
Routine maintenance should include cleaning the lenses with a dry lint free cloth, examination for any physical
damage, checking the tightness of the mountings, checking electrical connections.
The lamp should be replaced within its rated life of 9000hrs or when the light output begins to fall, or when the lamp
regularly fails to ignite within 30s of power-on.
W
ARNING: The Source Four CDM is rated to IP20 and therefore should only be used in an internal dry environment.
Routine maintenance procedures and intervals should be assessed on an individual basis based on the location, usage
and potential risks. This procedure should be documented as part of your site risk assessment.
Page 5
Installing the lampInstalling the lamp
Ensure that the power is isolated. Using the hex key provided, release the lampholder assembly and remove.
Without touching the glass envelope, push the lamp fully into the lampsocket ensuring that the reta
ining clips lock into
place.
Replace the lampholder assembly and tighten with the hex key.
Focussing the luminaireFocussing the luminaire
Pull all of the shutter blades outwards to produce a circular beam. The beam may be focussed by releasing the focus
screw on the underside of the lens barrel and sliding the barrel backwards or forwards.
The beam may be shaped or masked by adjusting the shutter blades.
An A size (100mm dia) or B size (86mm dia) metal gobo, glass gobo or dichroic coloured glass may be inserted into
either the gobo slot or the iris slot.
Note: The correct gobo holder must be used. If one has not been supplied, contact your dealer for details.
If using the iris slot for either an Iris diaphragm or a gobo,
the slot cover must be opened. Release the two screws and
slide back the cover. Insert the accessory, close the cover as
far as it will travel and tighten the screws again with the
cover in the closed position. This retains the accessory within
the slot.
For fine adjustment of the gobo rotation, the entire front
barrel of the fixture may be rotated by releasing the
barrel rotation knob, and rotating the lens barrel.
Tighten the knob after use.
Using Colour FiltersUsing Colour Filters
There are three colour filter options available;
1. Use standard theatrical colour filter in the holder supplied
2. Use Devon Glass filter in the front colour runner
3. Use an 86mm or 100mm dichroic filter in a glass
gobo holder in the gobo or iris slot (not the same slot
as any other accessory)
Note that for 1&2, the filter holder must be secured by ensuring that the retaining clip is in the locked position.
Page 4
Lamp replacement
Approved lamp types;
Philips Mastercolour CDM-T lamp 150W 830 (3000K) or 942 (4000K) or 70W 830 (3000K) or 70W 942 (4000K)
The Philips 70W or 150W CDM-T 830 (
3000K) or 942 (4000K) lamp has a manufacturer’s rated life of 9000 hrs.
This is a manufacturer’s rated life and is not a guaranteed life in real service. In practice it has been found that under
reasonable service conditions that this life expectancy is
common. It has been noted that there may be a degradation
in light output over the life of the lamp, which can become noticeable after 6000 hrs. We do not currently recommend
the use of any other manufacturer’s lamp.
It is important to replace any lamp t
hat fails to ignite or begins to cycle (switching on and off continually). Although
the ballast (if using the recommended type) will have a thermal cut-
off and timed ignitor to protect against damage,
the life of the ignitor may be reduced.
We recommend a planned annual maintenance and lamp change. This should avoid the need for occasional lamp
changes. In addition, you should assess the risk of accidental and deliberate damage, and the conditions under which
these fixtures are used, and plan additional maintenance as this risk assessment requires. It is often a statutory
requirement to keep a written record of your risk assessment and the measures employed.
The Philips CDM ceramic metal halide lamp has excellent colour rendering for a metal halide lam
p. The lamp will
reach its optimum output and stability after 100 hrs use. Before this time there may be a variation in colour
temperature and output. These phenomena may also occur when the position of the fixture is changed.
These effects are more noticeable with the 3000K 830 lamp types.
For installation of the lamp, please see the section Installing the Lamp above
Routine Maintenance
Routine maintenance should include cleaning the lenses with a dry lint free cloth, examination for any physical
damage, checking the tightness of the mountings, checking electrical connections.
The lamp should be replaced within its rated life of 9000hrs or when the light output begins to fall, or when the lamp
regularly fails to ignite within 30s of power-on.
W
ARNING: The Source Four CDM is rated to IP20 and therefore should only be used in an internal dry environment.
Routine maintenance procedures and intervals should be assessed on an individual basis based on the location, usage
and potential risks. This procedure should be documented as part of your site risk assessment.
Page 5
Mounting and connecting the remote control gearMounting and connecting the remote control gear
Mount
the fixture first in its final location. A number of mounting brackets are available from your dealer. We
recommend the use of a secondary suspension cable which is also available from your dealer in both black and
galvanised finish.
The Source Four CDM
is supplied with a 2m high voltage flex that must be connected to the remote encapsulated
control gear. If for any reason another control gear package is used, it must be of a type approved by Philips for use
with the CDM-T mastercolour lamp and must mee
t all local electrical codes. If in doubt, please contact Enliten for
advice.
Do not extend the luminaire flex Do not extend the luminaire flex
it is a special high voltage cable type and the maximum permitted distance it is a special high voltage cable type and the maximum permitted distance
between the fixture and remote encapsulated gear is 2m/6ft*between the fixture and remote encapsulated gear is 2m/6ft*
If
you must place the control gear more than 2m from the fixture, you should contact your dealer and upgrade the
control gear package to a 20m long range IP65 control gear package.
You should now securely mount the remote control gear in a suitable location
such that the luminaire flex will easily
reach the output terminals. The location must be ventilated to ensure that the ambient temperature does not rise
above 50°C.
You may now connect the luminaire to the control gear package
The installation and co
nnection of a Source Four CDM system to a mains supply should be carried out by a competent
electrician and all work should be carried out to local regulatory standards.
The connections are as follows;
Fixture to ballast
HT/Live Brown with white inner insulation
Neutral Blue with white inner insulation
Earth/Ground Green/Yellow
The Source Four CDM is a Class II (earthed) fixture and must be earthed/grounded even when connected to a Class I
(double insulated) control gear package.
Page 3
Source Four CDM Diagram
Page 6
Use black wire to
select voltage
[230]
[250]
[240]
L
E
N
LA
230/240/250V
50Hz
N
E
L
Before you startBefore you start
This package contains a Source Four CDM profile spotlight with remote (2m)magnetic control gear.
Ensure that you have the correct fixture (5°, 10°, 19°, 26°, 36°, 50°) this will be indicated on the carton.
In addition to the luminaire you will also have been supplied with;
Ensure that you have control gear to match the lamp wattage. Ensure that you have the correct colour temperature
lamp (see lamp replacement for further details)
Unpack & check for damage.
The Source Four CDM luminaire box should contain;
1 x Source Four CDM luminaire fitted with special lampholder assembly
1 x Hex Key
1 x Colour filter holder
If ordered with the fixture, other items including iris diaphragm, pattern holders and patterns may be included or
fitted. Please consult your box label and packing list for details.
Safety Information Safety Information
This fixture is for professional use only. Read the entire manual before use.
Do not mount this fixture on or near a flammable surface
This fixture is for interior use only for exterior applications use Callisto Exterior spotlight
We recommend the use of a safety cable as a secondary suspension
Always ensure that the colour frame clip is left in the locked position
Always replace the lamp if it is damaged or thermally deformed or is slow to start
Keep luminaire 0.7m from any lighted object
Disconnect the luminaire from power before cleaning, maintenance or re-lamping
Maximum ambient temperature t
a
=45°C
Maximum surface temperature t
max
=180°C
70/150W Magneticremote control
gear to suit local supply voltage
and frequency
Philips mastercolour
70/150W CDM-T lamp
Page 2
Warranty
Enliten warrants that the luminaire shall be free from manufacturing defects in materials and workmanship.
All luminaires are tested and inspected for damage prior to shipping.
Any claim under the warranty should be made to the dealer that supplied the equipment along with a copy of the invoice
and details of the problem. Should you be unable to get a satisfactory response from your dealer, or they are no longer
trading, please contact Enliten directly enclosing in addition, copies of any intermediate correspondence with your
dealer.
This warranty is a limited warranty and is given under English Law subject to the following (notwithstanding any statutory
requirements);
1. Enliten shall be under no liability in respect of any defect in the Goods arising from any drawing, design or
specification supplied by others
2. Enliten shall be under no liability in respect of any defect arising from fair wear and tear, wilful damage
negligence, abnormal working conditions, failure to follow Enliten’s instructions (whether oral or in writing),
misuse or alteration or repair of the Goods without Enliten’s written approval
3. Subject as expressly provided in these Conditions, and except where the Goods are sold under a consumer
sale (as defined by the UK Sale of Goods Act 1979), all warranties, conditions or other terms implied by
statute or common law are excluded to the fullest extent permitted by law.
4. Any claim which is based on any defect in the quality or conditions of the Goods shall (whether or not
delivery is refused by the Buyer) be notified to the dealer within 7 days from the date of delivery or where
the defect or failure was not apparent on reasonable inspection) within a reasonable time after discovery of
the defect or failure. If delivery is not refused, and the Buyer does not notify the dealer accordingly, the
Buyer shall not be entitled to reject the Goods and Enliten shall have no liability for such defect or failure
5. Except in respect of death or personal injury caused by Enliten’s negligence, Enliten shall not be liable to the
Buyer by reason of any representation, or any implied warranty, condition or other term or any duty at
common law, or under the express terms of the Contract, for any consequential loss or damage (whether for
loss of profit or otherwise), costs, expenses or other claims for consequential compensation whatsoever (and
whether caused by the negligence of Enliten, its employees or agents or otherwise) which arise out of or in
connection with the supply of the Goods or their use or resale by the Buyer, except as expressly provided in
these Conditions.
SpecificationsSpecifications;
Packed Size Max Voltage See control gear
Packed Weight Max Current See control gear
Lamp Type Philips CDM-T Minimum service interval 6 months
Lamp Wattage 70W or 150W Pattern Type B size glass or metal
Rated Lamp Life 9000hr Ballast Type To suit CDM-T
Lamp Base G12 IP Rating IP20
Special Tools Required Hex Key (supplied)
Conformity UL, CE EN60598
Page 7
USER’S GUIDE
Source Four CDM Gobo projector
with remote magnetic control gear
CONTENTS
Before you start 2
Mounting & connecting the remote control gear 3
Installing the lamp 4
Focussing the luminaire 4
Using colour filter 4
Lamp Replacement 5
Routine maintenance 5
Source Four CDM diagram 6
Warranty 7
Specifications 7
www.enliten.co.uk/manuals/S4CDM.pdf
Page 1
This page is left intentionally blank
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ETC Source Four LED Series User manual

Type
User manual

ETC Source Four LED Series is a professional-grade LED lighting system that offers a wide range of features and capabilities to meet the demands of various lighting applications. With its advanced LED technology, it provides exceptional color rendering, energy efficiency, and long-lasting performance.

The Source Four LED Series is known for its versatility, allowing users to create a variety of lighting effects and ambiances. Its high output and precise control make it suitable for use in theaters, studios, concerts, and other entertainment venues. Additionally, its compact size and lightweight design make it easy to handle and transport.

Ask a question and I''ll find the answer in the document