  • Hello! I am an AI chatbot trained to assist you with the TRIANGLE TUBE Delta Performance Heat Fab Appliance Adaptor Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Delta PERFORMANCE Appliance Adaptor
Heat Fab HMVADPT01
Follow the vent pipe manufacturer’s instruc-
tions for sealing the vent piping. The vent pipe
connector must be sealed gas-tight to prevent the
possibility of flue gas spillage and carbon
monoxide emissions, which could result in severe
personal injury or death.
WARNING
10/21/2003
2003-36-Heat Fab Delta PG Adaptor
Ensure Locking
Band is securely
tightened over
the flue hood
collar
Heat Fab Appliance Adapter
HMVADPT01
Apply a continuous 1/4" wide bead
of high temperature sealant
as specified by the vent manufacturer
along the inside surface 1/4" below
the upper edge
Delta Flue Hood
/