Metropolitan N6776-293 User manual

Type
User manual

Metropolitan N6776-293 is a versatile convertible lamp that offers multiple configurations to suit your lighting needs. It can be installed as a pendant with an adjustable height using the included rods or as a semi-flush mount for a more compact look. The fixture features a stylish design with a metal body and candle-style covers to enhance the ambiance of your space. The easy-to-follow instructions guide you through the installation process, ensuring a safe and secure setup.

Metropolitan N6776-293 is a versatile convertible lamp that offers multiple configurations to suit your lighting needs. It can be installed as a pendant with an adjustable height using the included rods or as a semi-flush mount for a more compact look. The fixture features a stylish design with a metal body and candle-style covers to enhance the ambiance of your space. The easy-to-follow instructions guide you through the installation process, ensuring a safe and secure setup.

INSTALLATION INSTRUCTIONS
Item#N6776-293(Convertible Lamps for Pendant) (New. 04/24/2017)
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Page: 1/3
Fig. 1
Fig. 3
LA-2744E
PREPARATION (Fig. 1)
1. Shut off the power at the fuse box or circuit breaker. If
necessary, remove the old fixture, including the mounting
hardware.
2. Carefully remove the fixture from the carton and check that all
parts are included as shown in the illustration.
ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig. 2)
3. Determine the desired hanging height and thread rods (F1, F2
and F3) to the nipple (I) of the fixture body (L). Then attach
loop (H1) by screwing in to rod (F1). Note: remove the nipple if
installing with one 6” rod only.
4. Attach the quick link (G) connect to loop (H1) and loop (H2) on
the canopy (D), carefully feed the wire over loop (H1), quick
link (G) and loop (H2).
5. Thread screws (A) into the pre-drilled holes in the circular
strap (B) spaced the same distance apart as the holes in the
canopy (D).
6. Attach the circular strap (B) to the Junction box using
mounting screws (C) (Size: #8-32N*L0.5”). The side of the
circular strap marked “GND” must face out.
7. The support cable is provided to support the weight of the
fixture while wiring. Align the fixture to circular strap (B) and
attach hook (U) on the end of support cable (N) into a slot
located on circular strap (B). Carefully allow the support cable
(N) to support the weight of the fixture while wiring.
CONNECTING THE WIRES (Fig. 3)
8. At this point, connect the electrical wires as shown in figure 3,
making sure that all wire connectors are secured. If your outlet
has a ground wire (green or bare copper), connect the fixture’s
ground wire to it. Otherwise, connect the fixture’s ground wire
directly to the circular strap using the green screw provided.
9. Tuck the wire connectors neatly into the ceiling Junction Box
and then raise the canopy all the way to the ceiling.
COMPLETING THE INSTALLATION (Fig. 1)
10. Thread canopy (D) into screws (A), and secure with knurled
knobs (E).
11. Place the candle cover (K) over the socket (M) of the fixture
body (L).
12. Install light bulb(s) (J) in accordance with the fixture’s
specification. (DO NOT EXCEED THE MAXIMUM WATTAGE
RATING!) (NE PAS DEPASSER LA PUISSANCE NOMINALE
MAXIMALE!).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased.
Set# A-020-A
-Circular Strap
-Ground Screw
-Mounting Screw*2
Rod# W30-1-293*1(F1)
W30-1-293*2(F2)
W30-H-293*1(F3)
Candle Cover# CCV24050P-293
C
B
N
U
A
E
D
F1
G
H1
H2
F3
J
K
I
L
M
F2
FIXTURE
WIRES
Black or
Smooth
H
O
U
S
E
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
H
O
U
S
E
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
H
O
U
S
E
WIRES
Green
(Ground)
Fig.2
Page: 2/3
LA-2744E
F1
C
E
D
H1
A
B
G
H2
b. Hardware Bag:
F1. ROD 12"*1
F2. ROD 12"*2
F3. ROD 6"*1
F1
F2
F3
A
E
C
D
B
G H
a. Hardware Bag:
A. Screw*2
B. Circular Strap*1
D. Canopy *1
C. Mounting Screw*2
E. Knurled Knob*2
H. Loop*2
G. Quick Link*1
INSTALLATION INSTRUCTIONS
Item#N6776-293 (Convertible Lamps for Semi Flush Mount) (New. 04/24/2017)
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Page: 3/3
Fig. 4
Fig. 5
PREPARATION (Fig. 5)
1. Loosen hex nut (O) by using wrench (N). Carefully remove
washer (P), lock washer (Q), L-type pare (T),metal plate (R),
canopy (D) and loop (H2)(Fig.5). Cut down a length of wire if
the wire is too long.
2. Secure metal tube (S) onto nipple (I).
3. Thread canopy (D), metal plate (R), L-type pare (T) lock
washer (Q), washer (P) and hex nut (O) into the nipple at the
metal tube (S).Then secure hex nut (O) by using wrench (N).
(Fig. 4)
4. Thread screws (A) into the pre-drilled holes in the circular
strap (B) spaced the same distance apart as the holes in the
canopy (D). (Fig. 4)
5. Attach the circular strap (B) to the Junction box using
mounting screws (C) (Size: #8-32N*L0.5”). The side of the
circular strap marked “GND” must face out. (Fig. 4)
6. The support cable is provided to support the weight of the
fixture while wiring. Align the fixture to circular strap (B) and
attach hook (U) on the end of support cable (N) into a slot
located on circular strap (B). Carefully allow the support cable
(N) to support the weight of the fixture while wiring.
CONNECTING THE WIRES (Fig. 3)
7. At this point, connect the electrical wires as shown in figure 3,
making sure that all wire connectors are secured. If your outlet
has a ground wire (green or bare copper), connect the fixture’s
ground wire to it. Otherwise, connect the fixture’s ground wire
directly to the circular strap using the green screw provided.
8. Tuck the wire connectors neatly into the ceiling Junction Box
and then raise the canopy all the way to the ceiling.
COMPLETING THE INSTALLATION (Fig. 4)
9. Thread screws (A) into canopy (D), and secure with knurled
knobs (E).
10. Place the candle cover (K) over the socket (M) of the fixture
body (L).
11. Install light bulb(s) (J) in accordance with the fixture’s
specification. (DO NOT EXCEED THE MAXIMUM WATTAGE
RATING!) (NE PAS DEPASSER LA PUISSANCE NOMINALE
MAXIMALE!).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased
Set# A-020-A
-Circular Strap
-Ground Screw
-Mounting Screw*2
O
Q
R
P
T
H2
D
H
LA-2744E
Candle Cover# CCV24050P-293
T
U
B
A
N
C
O
R
P
Q
J
K
I
L
M
D
E
S
Spanner#
  • Page 1 1
  • Page 2 2
  • Page 3 3

Metropolitan N6776-293 User manual

Type
User manual

Metropolitan N6776-293 is a versatile convertible lamp that offers multiple configurations to suit your lighting needs. It can be installed as a pendant with an adjustable height using the included rods or as a semi-flush mount for a more compact look. The fixture features a stylish design with a metal body and candle-style covers to enhance the ambiance of your space. The easy-to-follow instructions guide you through the installation process, ensuring a safe and secure setup.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI