DKS 6003/ 6004 / 6005 / 6400/ 24V Control Box 8/18 - 4/20 User manual

Category
Gate Opener
Type
User manual
Copyright 2009 DoorKing, Inc. All rights reserved.
Copyright 2018 DoorKing, Inc. All rights reserved.
Use this manual for circuit board 4302-018 Revision A or higher.
Wiring / Owner’s
Manual
Solar Control Box for
Solar Control Box for
Solar Control Box for
6003, 6004, 6005 and 6400 gate operators
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Circuit Board
Serial Number
and Revision Letter:
Solar
Control
Box
24 Volt
24
Volt
20 Watt
20 Watt
Solar
Solar
Panel
Pane
l
24 Volt
24
Volt
10 Watt
10 Watt
Solar
Sola
r
Panel
Pane
l
O
P
E
N
C
L
O
S
E
6003
C
L
A
S
S
C
E
R
T
I
F
I
ED
T
O
C
A
N
/
C
S
A
C
2
2
.
2
N
O
.
2
4
7
C
O
N
F
O
R
M
S
T
O
AN
SI
/
U
L
-3
2
5
V
E
H
IC
U
L
A
R
G
AT
E
O
P
E
R
A
T
O
R
H
P
5
3
3
8
2
M
O
D
E
L
S
ER
I
A
L
V
O
L
T
S
P
H
AS
E
A
MP
S
6
0
H
z
M
A
X
G
AT
E
LO
A
D
Doo
r
K
in
g
,
I
n
c
.
,
I
n
gl
e
w
o
o
d
,
C
A
6004
D
OO
R
KI
N
G
6005
6400
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
Visit
www.dkslocator.com
to find a professional installing and servicing dealer in your area.
Conforms To UL STD 325
Certified To CSA STD C22.2 # 247
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator
will NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
UL 325 August 2018 Standard
4302-067-B-7-18
4302-067-B-7-18
1
1 2 3 4 5 6 7 8 9 1011 12 131415 16171819 20
ON
OFF
PUSH TO OPERATE
technician use only
Solar NEG
Solar POS
24 V POS
24 V NEG
Relay COM
Relay N.O.
Full Open
Not Used
Not Used
B
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons
of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights
reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
8.25”13.25”
21.25”
PUS
t
e
c
S
olar NE
G
S
olar P
OS
2
4 V P
OS
24 V NE
G
Rela
y
CO
M
Rela
y
N.O
.
Full O
p
e
n
N
ot Use
d
N
ot
U
se
d
12 V
18 Amp/Hr
Battery
12 V
18 Amp/Hr
Battery
12 V
35 Amp/Hr
Battery
12 V
35 Amp/Hr
Battery
Optional
Mounting
Post Kit
for Control
Box
P/N 1000-045
33”
Class of Operation Models 6003, 6004, 6005 and 6400 - UL325 Class I
Type of Gate Residential Vehicular Automated Gates Only
Voltage / Phase 24 Volt Solar Input Power – 24 VDC Output Power to Gate Operators
Battery Capacity Two - 12 Volt 18 Amp/Hour Dry Cell OR Two - 12 Volt 35 Amp/Hour Dry Cell
Solar Panel Voltage 24 Volt 10 Watt for 18 Amp/Hour Dry Cells OR 24 Volt 20 Watt for 35 Amp/Hour Dry Cells
Circuit Board Model 4302-018 revision A or higher.
Inherent Entrapment Protection Device Inherent Reverse Sensor System (Type A)
External Entrapment Protection Device Inputs Monitored input connection for Non-contact Sensor - Photo Sensor (Type B1)
Monitored input connection for Contact Sensor - Reversing Edge (Type B2)
18 Amp/Hr Control Box
P/N 4302-114
No Batteries Control Box
P/N 4302-113
35 Amp/Hr Control Box
P/N 4302-115
SOLAR CONTROL BOX SPECIFICATIONS
1 2 3 4 5 6 7 8 9 1011121314151617181920
ON
OFF
PUSH TO OPERATE
technician use only
Solar NEG
Solar POS
24 V POS
24 V NEG
Relay COM
Relay N.O.
Full Open
Not Used
Not Used
B
13.25”
PUS
te
S
olar NE
G
S
olar P
OS
2
4 V P
OS
24 V NE
G
Rela
y
CO
M
Rela
y
N.O
.
Full Ope
n
N
ot Use
d
N
ot
U
se
d
Optional 24 Volt 10 Watt
Solar Panel only for
18 Amp/Hr Batteries
P/N 2000-077
Optional 24 Volt 20 Watt
Solar Panel only for
35 Amp/Hr Batteries
P/N 2000-076
11.8
21.8
.98
.98
13.8
13.8
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
The operator will not run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.
4302-067-B-7-18
2
SPECIFICATIONS 1
Solar Control Box Specifications
ASTM F2200 Standard for Gate Construction
Important Safety Instructions
Instructions regarding intended installation:
Important Notices
UL 325 Entrapment Protection
Glossary
Swing Gate Requirements
Swing Gate Protection
1
3
3
3-4
4
5
6
7
8
SECTION 2 - WIRING 11
11
12
13
14
15
16
17
2.1 Control Box Wiring Overview
2.2 Wiring Operators to 4302 Circuit Board
2.3 Entrapment Protection Wiring
2.4 Full Open Terminal Wiring
2.5 Loop Detector Wiring
2.6 Battery Wiring
2.7 Solar Panel Wiring
SECTION 1 - SOLAR PANEL INSTALLATION CONSIDERATIONS 9
9
10
1.1 Solar Panel Concerns BEFORE Installation
1.2 Solar Panel Positioning
IMPORTANT INFORMATION FOR OWNER
33
33
34
Shut-Off Power to Operator OR Shut-OFF Alarm
Manually Operating the Gate - NO Power
SECTION 4 - MAINTENANCE AND TROUBLESHOOTING 28
4.1 Maintenance
4.2 Diagnostics Check
4.3 Troubleshooting
4.4 Accessory Items
Solar Control Box Schematics
28
28-29
29-30
31
32
TABLE OF CONTENTS
SECTION 3 - ADJUSTMENTS 18
18
19-20
21-24
25
26-27
3.1 3402 Circuit Board Description and Adjustments
3.2 DIP-Switches
3.3 Limit Sensors Adjustment - Select your specific operator
3.4 Inherent Reverse Sensor Adjustment
3.5 Shutdown Conditions
Soft Shutdown
Hard Shutdown (Alarm Activated)
21
22
23
24
6003 Limit Sensors ONLY
6004 Limit Sensors ONLY
6005 Limit Sensors ONLY
6400 Limit Sensors ONLY
4302-067-B-7-18
3
Instructions regarding intended installation:
Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction.
For a copy of this standard, contact ASTM directly at 610-832-9585; [email protected]; or www.astm.org.
Important Safety Instructions
WARNING - To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors.
After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of
injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS!
Install the gate operator only if:
1. The operator is appropriate for the construction of the gate and the usage class of the gate.
2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the ground to
prevent a 2 ¼ inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence
that the gate covers in the open position.
3. All exposed pinch points are eliminated or guarded.
4. Guarding is supplied for exposed rollers.
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian
access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate
during the entire path of travel of the vehicular gate.
The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to
reduce the risk of entrapment. Swinging gates should not open into public access areas.
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator
clutch, pressure relief valve or reduce reversing sensitivity to compensate for a damaged gate.
For gate operators utilizing Type D protection:
1. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving.
2. A warning placard shall be placed adjacent to the controls.
3. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed.
4. No other activation device shall be connected.
Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from
reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls should have a security feature to prevent
unauthorized use.
The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
For gate operators utilizing a non-contact sensor:
1. See the instructions on the placement of non-contact sensors for each type of application.
2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction.
3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving
gate or barrier.
For gate operators utilizing contact sensors:
1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and
post mounted both inside and outside of a vehicular horizontal slide gate.
2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not
subjected to mechanical damage.
5. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall
be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar
obstructions. A wireless contact sensor shall function under the intended end-use conditions.
6. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
Be sure you have instructed the owner of the gate operator about safe and proper operation and testing of the gate operator.
ASTM F2200 Standard for Gate Construction
4302-067-B-7-18
4
Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people
underestimate the power of these systems and do not realize the potential hazards associated with an incorrectly designed or installed system.
These hazards may include:
Pinch points
Entrapment areas
Reach through hazards
Absence of entrapment protection devices
Improperly located access controls
Absence of vehicle protection devices
Absence of controlled pedestrian access
In addition to these potential hazards, automated vehicular gate systems must be installed in accordance with the UL 325 Safety Standard and the ASTM
F2200 Construction Standard. Most people are unaware of, or are not familiar with, these standards. If an automated vehicular gate system is not properly
designed, installed, used and maintained, serious injuries or death can result. Be sure that the installer has instructed you on the proper operation of the
gate and gate operator system.
Be sure that the installer has trained you on proper and safe operation of this gate operating system and about the basic functions of the required
reversing systems associated with your gate operating system and how to test them. These include reversing loops, inherent reversing system, electric
edges, photoelectric cells, or other external devices.
This Owner’s Manual is your property. Keep it in a safe place for future reference.
Be sure that all access control devices are installed a minimum distance of 6 feet away from the gate and gate operator, or in such a way that a
person cannot touch the gate or gate operator while using the device. If access control devices are installed in violation of these restrictions,
immediately remove the gate operator from service and contact your installing dealer.
Important Notices
Opening device MUST be mounted a
minimum of 6 feet from the gate and
NOT accessible through the gate!
Loops and loop detectors, photo-cells or other equivalent devices must be installed to prevent the gate from closing on vehicular traffic.
The speed limit for vehicular traffic through the gate area is 5 MPH. Install speed bumps and signs to keep vehicular traffic from speeding
through the gate area. Failure to adhere to posted speed limits can result in damage to the gate, gate operator, and to the vehicle.
Be sure that all persons who will use the gate system are familiar with the proper use of the gate and gate operator and are familiar with the
possible hazards associated with the gate system.
Be sure that warning signs are permanently installed on both sides of the gate in an area where they are fully visible to traffic.
It is your responsibility to periodically check all entrapment protection devices. If any of these devices are observed to function improperly,
remove the operator from service immediately and contact your installing or servicing dealer.
Follow the recommended maintenance schedule.
Do not allow children to play in the area of the operator or to play with any gate-operating device.
To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel.
4302-067-B-7-18
5
UL 325 Entrapment Protection
Class I - Residential
Vehicular Gate Operator
Entrapment Protection Types
Class II - Commercial/General Access
Vehicular Gate Operator
Class III - Industrial/Limited Access
Vehicular Gate Operator
Class IV -
Restricted Access
Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in garages
or parking areas associated with a residence of one-to four single
families.
A vehicular gate operator (or system) intended for use in a
commercial location or building such as a multi-family housing
unit (five or more single family units), hotel, garages, retail store,
or other buildings accessible by or servicing the general public.
A vehicular gate operator (or system) intended for use in an
industrial location or building such as a factory or loading dock
area or other locations not accessible by or intended to service
the general public.
A vehicular gate operator (or system) intended for use in a
guarded industrial location or building such as an airport security
area or other restricted access locations not servicing the general
public, in which unauthorized access is prevented via supervision
by security personnel.
Gate Operator Category
UL 325 Classifications
Type A - Inherent entrapment protection system.
Type B1 - Non-contact sensor (photoelectric sensor or the equivalent).
Type B2 - Contact sensor (edge device or equivalent).
Type C - Inherent force limiting, inherent adjustable clutch or inherent pressure relief device.
Type D - Actuating device requiring constant pressure to maintain opening or closing motion of the gate.
* B1 and B2 means of entrapment protection must be MONITORED.
Vertical Barrier Note: Barrier gate operators (arm)
that is not intended to move toward a rigid object
closer than 16 inches (406 mm) are not required to
be provided with a means of entrapment protection.
STATE PRISON
Horizontal Slide, Vertical Lift, Vertical Pivot Swing, Vertical Barrier (Arm)
A, B1*, B2* or D A, B1*, B2*, C or D
Effective January 12, 2016
Authorized
Personnel ONLY
4302-067-B-7-18
6
Glossary
GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage
barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and
completes the perimeter of a defined area.
RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I - A vehicular gate operator (or system) intended for use in a home
of one-to four single family dwelling, or garage or parking area associated therewith.
COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR - CLASS II - A vehicular gate operator (or system)
intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units),
hotels, garages, retail store, or other building servicing the general public.
INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III - A vehicular gate operator (or system)
intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended
to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV - A vehicular gate operator (or system) intended for use in
a guarded industrial location or building such as an airport security area or other restricted access locations not servicing
the general public, in which unauthorized access is prevented via supervision by security personnel.
VEHICULAR BARRIER (ARM) OPERATOR (OR SYSTEM) - An operator (or system) that controls a cantilever type device (or
system), consisting of a mechanical arm or barrier that moves in a vertical arc, intended for vehicular traffic flow at
entrances or exits to areas such as parking garages, lots or toll areas.
VEHICULAR HORIZONTAL SLIDE-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a
gate which slides in a horizontal direction that is intended for use for vehicular entrance and exit to a drive, parking lot, or
the like.
VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which
moves in an arc in a horizontal plane that is intended for use for vehicular entrance and exit to a drive, parking lot, or the
like.
SYSTEM - In the context of these requirements, a system refers to a group of interacting devices intended to perform a
common function.
WIRED CONTROL - A control implemented in a form of fixed physical interconnections between the control, the associated
devices, and an operator to perform predetermined functions in response to input signals.
WIRELESS CONTROL - A control implemented in means other than fixed physical interconnections (such as radio waves or
infrared beams) between the control, the associated devices, and an operator to perform predetermined functions in
response to input signals.
INHERENT ENTRAPMENT PROTECTION SYSTEM - A system, examples being a motor current or speed sensing system,
which provides protection against entrapment upon sensing an object and is incorporated as a permanent and integral part
of the operator.
EXTERNAL ENTRAPMENT PROTECTION DEVICE - A device, examples being an edge sensor, a photoelectric sensor, or
similar entrapment protection device, which provides protection against entrapment when activated and is not incorporated
as a permanent part of an operator.
ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury.
4302-067-B-7-18
7
Swing Gate Requirements
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate
access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that
persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
Closed Gates
If distance is greater than 4 inches,
entrapment protection for this area is
required.
If distance is less than 16 inches,
entrapment protection in this area
is required.
A
B
A
B
Closed Gate
With the hinge mounted on
the corner of the pilaster,
the entrapment area is
eliminated and protection
is NOT required for this
area.
Closed Gate
Opened Gate
Opened Gate
A
Not Allowed OK
Gates shall have smooth bottom edges, with vertical
bottom edged protrusions not exceeding 0.50 inches.
If bottom of gate is 6” to 16”above the ground
at any part of the gate’s traveling path,
entrapment protection for this area is required.
6 inches to 16 inches
4302-067-B-7-18
8
Swing Gate ProtectionSwing Gate Protection
Warning Signs
D
Permanently mounted and
easily visible from either
side of the gate.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
C
E
D
D
Separate Pedestrian
Walkway
Located so pedestrians
cannot come in contact with
the vehicular gate.
Non-contact Sensor
C
E
Minimizes the potential of the
gate closing on vehicular or
other traffic that loops cannot
sense. Monitored device helps
protect against entrapment
when needed.
Non-contact Sensor
Minimizes the potential of
the gate striking vehicular or
other traffic that loops
cannot sense. Monitored
device helps protect against
entrapment when needed.
Minimizes the potential of the gate
striking vehicular or other traffic
that loops cannot sense. Monitored
device helps protect against
entrapment when needed.
F
F
Contact Sensor
Reverse Loop
Shadow Loop
Automatic Exit Loop
Minimizes the potential of the gate
closing when a vehicle is present.
Number and placement of loops is
dependent on the application.
Reverse Loop
Minimizes the potential of the gate
closing when a vehicle is present.
Number and placement of loops is
dependent on the application.
(Optional) will provide an open
command to the gate operator(s)
when a vehicle is exiting the
property.
Provides a hold open command to
the operator(s) only if the gate(s)
are at the full open position.
Note: Not used for solar control
box installations.
External entrapment
protection is REQUIRED
for operator to function.
4302-067-B-7-18
9
1.1 Concerns BEFORE Installation
Correct positioning of the solar panel will determine the efficiency of the system. In general, the panel should be facing TRUE
SOUTH at a specific TILT ANGLE towards the sun using the information provided on the next page to achieve the highest
efficiency. Some re-adjustment of the panel might be necessary to over time to “Fine Tune” the systems efficiency. The solar
panel should be installed as close as possible to the control box in an area free and clear of ALL obstructions and shadows
during the ENTIRE day. Generally, If the solar panel does NOT cast a shadow by the sun, the batteries are NOT being charged.
Trees / Buildings that do not block the solar panel from direct sunlight in the summer,
could block the panel during the winter. The sun’s path across the sky is lower during the winter
than in the summer. The shadows that do not obstruct the solar panel during the summer
months, will cast longer shadows in the winter, which could block the panel then.
• Wind can exert extreme pressure on the solar panel and support post. Make sure they are
securely fastened.
• Dust can accumulate on the panel over time. Cleaning the panel every so often is necessary to
keep the system operating at its highest efficiency.
• Snow may cover the panel during the winter. You may want to re-adjust the panel to a steeper
angle to allow the snow to slide off. Even then, the panel may still accumulate snow and need to
be manually cleaned off when necessary to keep the system functioning.
True South
Tilt
Angle
Sample Installation
Dual Gate Operators with 35 Amp/Hr Batteries
SECTION 1 - SOLAR PANEL INSTALLATION CONSIDERATIONS
Mounting
Recommendations
The solar panel will perform MOST efficient when
installed as close as possible to the control box
(Within a couple of feet). Installation can be a maximum of
100 ft away from the box if necessary using a minimum 18
gauge wire run. Keep in mind, the efficiency of the solar panel will
diminish the farther away the panel is installed from the control box.
Solar Control Box Requirements:
(1) ONE 24 Volt 10 Watt Solar Panel (P/N 2000-077) for 18 Amp/Hr Batteries.
(1) ONE 24 Volt 20 Watt Solar Panel (P/N 2000-076) for 35 Amp/Hr Batteries.
4302-067-B-7-18
10
1.2 Solar Panel Positioning
-21°
-20°
-19°
-18°
-17°
-16°
-15°
-14°
-13°
-12°
-11°
-10°
-9° -8°
-7°
-6°
-5°
35°
75°
-4°
-3°
-2°
-1°
+1°
+2°
+3°
+4°
+5°
+6°
+7°
+8°
+9°
+10°
+11°
+12°
+13°
+14°
+15°
+16°
+17°
+18°
+19°
+20°
+21°
+22°
Degrees East of “Compass 180° Magnetic South”.
SUBTRACT to achieve TRUE SOUTH.
Solar Panel MUST Point “TRUE SOUTH”
General Solar Panel “Tilt Angle”
Degrees West of “Compass 180° Magnetic South”.
ADD to achieve TRUE SOUTH.
Subtract
Degrees
East
Compass
Magnetic
South
18
270° 90°
N
S
WE
Add
Degrees
West
Compass
Magnetic
South
18
270° 90°
N
S
WE
7
5
°
A
n
g
l
e
7
0
°
A
n
g
l
e
6
5
°
A
n
g
l
e
6
0
°
A
n
g
l
e
5
5
°
A
n
g
l
e
5
0
°
A
n
g
l
e
4
5
°
A
n
g
l
e
4
0
°
A
n
g
l
e
3
5
°
A
n
g
l
e
It is important for proper system operation that the solar panel is oriented to TRUE SOUTH. The directions of magnetic South and TRUE South differ from one
another depending on geographic location. The map below shows the difference between magnetic south and TRUE south for your area.
These charts should be used only for estimates. Solar systems can vary from this information. These maps do not take into
account small climate changes and may not be 100% accurate for all locations.
It is simplest to mount the solar panel at a fixed tilt angle and leave it (Shown on chart below). To capture more energy from the sun,
you can adjust the tilt angle of the solar panel twice a year (At the beginning of summer and winter). Add approximately 6° in the
summer and subtract approximately 6° in the winter from your “general” tilt angle on this chart. Your tilt angle may vary from this.
50°
4302-067-B-7-18
11
2.1 Control Box Wiring Overview
SECTION 2 - WIRING
Since building codes vary from city to city, we highly recommend that you check with your local building department prior to
installing any permanent wiring to be sure that all wiring to the solar control box complies with local code requirements.
Conduit
12 V
Battery
12 V
Battery
1 2 3 4 5 6 7 8 9 1011 121314151617181920
ON
OFF
PUSH TO OPERATE
technician use only
Solar NEG
Solar POS
24 V POS
24 V NEG
Relay COM
Relay N.O.
Full Open
Not Used
Not Used
B
Solar Power Input
See page 17.
Circuit Board Terminal
Battery Plug
See page 17.
Batteries
See page 16.
PRIMARY Operator
Connection ONLY
See page 12.
SECONDARY Operator
Connection ONLY
See page 12.
Full Open Terminal
See page 14.
Power Terminal
See page 17.
P
US
H
te
c
S
olar NE
G
S
olar P
OS
2
4 V P
OS
24 V NE
G
Rela
y
CO
M
Relay N.
O.
F
ull O
p
en
Not
U
sed
Not
U
sed
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
CONNECTOR
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
Power Switch
See page 17.
“Optional” Loop Detectors See pages 14 and 15.
C
UL 325 Terminal
See page 13.
FULL
OPEN
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
4302-067-B-7-18
12
2.2 Wiring Operators to 4302 Circuit Board
Secondary Operator ONLY
Primary/Single Operator ONLY
6400 Wiring
1
7
8
6
5
4
3
2
Blue wire
Brown wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
SECONDARY
1
7
8
6
5
4
3
2
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
PRIMARY
6400 Primary/Single
operator wiring
6400 Secondary
operator wiring
Note: Secondary operator MOTOR wires
MUST be reversed from the primary
operator when using DUAL gate operators.
Note: RED and GREEN wires from
operator cable are not used.
Factory wired jumpers MUST be removed.
Factory wired jumpers MUST be removed.
1
7
6
5
4
3
2
1 2 3 4 5 6 7 8 9 1011121314151617181920
1
7
6
5
4
3
2
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
FULL
OPEN
C
L
A
S
S
C
E
R
T
I
F
I
E
D
T
O
C
A
N/C
S
A
C
2
2
.
2
N
O.
2
4
7
C
O
NF
O
R
M
S
T
O
A
NS
I
/
U
L
-
3
2
5
V
E
H
I
C
U
L
A
R
G
AT
E
O
P
E
RAT
O
R
H
P
5
3
3
8
2
M
O
D
E
L
S
E
R
I
A
L
V
OL
T
S
P
HA
S
E
A
M
P
S
6
0
H
z
M
A
X
G
A
T
E
L
O
A
D
D
o
o
r
K
i
n
g
,
In
c.
,
I
n
g
le
w
o
o
d,
C
A
6003 Wiring
6004 Wiring
1
7
8
6
5
4
3
2
SECONDARY
1
7
8
6
5
4
3
2
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
PRIMARY
Primary/Single
operator wiring
Secondary
operator wiring
6005 Wiring
1
7
8
6
5
4
3
2
Brown wire
Blue wire
Red wire
JUMPER
Yellow wire
JUMPER
Green/Yellow wire
JUMPER
SECONDARY
1
7
8
6
5
4
3
2
Brown wire
Blue wire
Red wire
JUMPER
Yellow wire
JUMPER
Green/Yellow wire
JUMPER
PRIMARY
6005 Primary/Single
operator wiring
6005 Secondary
operator wiring
Choose Your Operator Model: Follow wiring colors
for the PRIMARY/Single or DUAL gate operators.
DO NOT connect secondary operator to this terminal.
DO NOT connect primary/single
operator to this terminal.
DOORKING
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
IMPORTANT: An external entrapment protection device
MUST be installed or the operator will NOT function.
DO NOT cycle the operator
BEFORE setting limit sensors.
Factory wired jumpers MUST
remain connected as shown.
Factory wired jumpers MUST
remain connected as shown.
SLO DWN LEDs are always lit.
5-Wire OR 7-Wire
Operator Cable
(Depending on your model)
7-Wire Operator Cable
7-Wire
Operator Cable
5-Wire Operator Cable
4302-067-B-7-18
13
2.3 Entrapment Protection Wiring
Normally Closed
Normally Closed
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
Closed Gate
OPEN/CLOSE Edge/Beam UL 325 DIP-Switch 1 ON:
OPENING: Obstructed open-direction device will Reverse the gate to the
CLOSE position.
CLOSE Beam UL 325 DIP-Switch 2 ON:
CLOSING: Obstructed closing-direction photo beam will REVERSE the
gate to the open position and reset timer when ON.
CLOSING: Obstructed close-direction Beam will Reverse the gate back to
the open position and reset timer. If obstruction occurs again during the
closing-direction, Gate will reverse back to open position and enter a soft
shutdown.
Switch 2 Must be ON.
Switch 1
Must be ON.
UL 325 Terminal
UL 325 Terminal
4302
Note: Only 1 monitored Device can be connected to
each input. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
OPEN Beam
CLOSE Beam
Reversing Edge
1
2
3
4
5
6
CB
OB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
CB
OB
Not Used
Not Used
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
Close Beam
OPEN Beam
1
ON
2
Switch 1 Must be ON
for reversing edge.
Close Beam
OPEN Beam
1
ON
2
CLOSE Beam
OPEN Beam
1
ON
2
SW1
1
UL 325 DIP-Switch
OPEN/CLOSE Edge/Beam (Switch 1)
CLOSE Beam (Switch 2)
DIP-switches MUST be
turned ON for each
device wired to terminal.
FULL
OPEN
Monitored CLOSE
Photo Sensor
Monitored
OPEN Photo Sensor OR
Monitored OPEN/CLOSE
Reversing Edge
1
2
IMPORTANT: Photo sensors must use
Normally Closed (NC) contacts with the
beam set for light operate (relay
activated when beam is not obstructed).
Some manufacturer’s photo sensor
contacts are labeled as Normally Open
(NO) but their relay functions the same
way as described above. See specific
manufacturer’s wiring manual for more
information about their specific relay
function.
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of photo sensors-Type B1 and/or
reversing edges-Type B2 entrapment protection required by UL 325 standards. Entrapment Protection must be provided for the gate system
where the risk of entrapment or obstruction exists. The operator will NOT run without one or more monitored type B1 or B2 external
entrapment protection devices installed in each entrapment area. Install these devices where the risk of entrapment or a safety hazard
exists. Installations can vary.
If the distance between an entrapment
or obstruction exists less than 16”
from the open gate, then entrapment
protection is REQUIRED for this area.
Open Gate
Entrapment protection
is RECOMMENDED for
this area.
OPEN/CLOSE Edge/Beam:
Input will activate in EITHER direction of gate travel.
CLOSE Beam:
Input will activate in CLOSE direction of gate travel ONLY.
Only 1 Device can be
wired to each input.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.
4302-067-B-7-18
14
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
2.4 Full Open Terminal Wiring
Key Switch
(Dry contact)
Safety Opening
Device
Controls must be far
enough from the gate so
that the user is prevented
from coming in contact
with the gate while
operating them. Do not
wire any access control
devices to the circuit
board terminal.
Important: Low current draw loop
detectors MUST be used to
minimize power drain on batteries.
Loop detectors MUST have power
at ALL times.
N.O.
Radio #1 Com (White)
Radio #2 Relay (Green)
Radio #3 Power (Red)
Com
N.O.
Com
N.O.
Com
Com
Power
N.O.
Com
Power
7123456 8
ON
OFF
PUSH TO OPERATE
technician use only
Solar NEG
Solar POS
24 V POS
24 V NEG
Relay COM
Relay N.O.
Full Open
Not Used
Not Used
DoorKing
RF Radio Receiver
Mount inside of control box door.
Use 18 AWG min.
Coax
Antenna Kit
P/N 1514-073
Antenna
mounted outside
control box.
250 mA Maximum Power
#1
#2
#3
Low Current Draw
Single Channel
External EXIT
Loop Detector
Low Current Draw
Single Channel
External REVERSE
Loop Detector
24 V Pos
Relay Com
Relay N.O.
Full Open Terminal Operation: When the circuit board
is NOT in use (idle time), power is shut down to it.
Power will continue at the Full Open Terminal at all
times. This allows an access control device - radio
receiver, key switch, exit loop or safety opening
device to be activated at any time to open the gate.
ANY access control device used needs a relay
contact time of AT LEAST 1 SECOND to bring the
circuit board out of “idle time” and operate gate.
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
Circuit Board Terminal
Loops
wired in
series
P/N 9402-050
P/N 9402-050
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
Automatic Exit
Loop
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
Loop detector
mounting position
Use existing
screws to mount
detector(s)
Reverse
Loop
Reverse
Loop
See next page for more
exit loop wiring information.
See next page for more
reverse loop wiring information.
1
2
3
Low Current
Draw Receiver
P/N 8055-081
OB
CB
Beam
Edge
GND
GND
SW1
1
ON
2
1476-010
FULL
OPEN
24 V POS Terminal Note:
Exceeding 250 mA of power
from this terminal may cause
the circuit board transformer to
overheat, causing intermittent
problems.
Type of wiring to be used
on ALL external devices:
A) Type CL2, CL2P, CL2R,
or CL2X.
B) Other cable with
equivalent or better
electrical,mechanical, and
flammability ratings.
Dry
Contact
4302-067-B-7-18
15
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
Full Open
Dry Relay Contact
Dry Relay Contact
Exit Loop Port
Shadow
Reverse
Revers
e
Automatic Exit
Secure Side
Inside Property
Non-Secure
Side
Outside Property
2.5 Loop Detector Wiring
Automatic Exit Loop
Automatically opens the gate for exiting vehicles
without having to use a transmitter or key switch
(Free exit).
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
A
PVC conduit to
Control box.
B
Exit loop lead-in
wires are twisted
approx. 6 twists
per foot.
PVC conduit to
Control box.
A
LOOP 1
Shadow loop
lead-in wires are
twisted approx.
6 twists per foot.
4302
SW 1, switch 5
is OFF.
SW 2, switch 1
is OFF and
switch 2 is ON.
DIP-Switch Settings
SW 1
1
ON
2 3 4 5 6 7 8
SW 2
1
ON
2 3 4
DO NOT USE
REVERSE LOOP PORT
DoorKing Plug-In
Single Channel
Loop Detector
Low Current Draw
Single Channel
External Exit
Loop Detector
Low Current Draw
SIngle Channel
External Reverse
Loop Detector
Circuit Board Terminal
Standard Reverse
Low Voltage Common
9410
Single Channel
To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops
and loop detectors are used. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate
operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recom-
mends that a licensed installer perform this work.
See the specific
loop detector
instruction sheet
and previous
page for wiring.
See the specific
loop detector
instruction sheet
and previous
page for wiring.
Jumper wires required for shadow loop.
To external reverse loop detector.
Exit and Reverse Loops Note: Low current draw
external exit and reverse loop detectors are used in
place of the plug-in exit and reverse loop detectors to
maintain power to these loops at all times. Circuit
board shuts down power to plug-in loop detectors
when not in use (idle time).
ANY loop detector used needs a relay contact time
of AT LEAST 1 SECOND to bring circuit board out of
“idle time” and operate gate.
#4 to #11
#8 to #10
DO NOT USE
EXIT LOOP PORT
DoorKing offers a free “Loop and
Loop-Detectors Information Manual
PDF located at Doorking’s web site for
more information. www.doorking.com
Shadow Loop Note: A shadow loop can NOT be
wired to the solar control box.
The circuit board relay
(Dry Relay Contact) is
used and MUST be set
to N.O.
NO
NC
Di
abl
o
Cont
r
ol
s,
Inc.
S
tuc
k
i
n
t
ra
ffi
c
for ov
e
r 37
y
e
a
rs
!
N
C
C
OM
RE
L
A
Y
10
to
3
0
V
o
l
t
s
A
C
o
r
D
C
P
OWER
DETEC
T
DSP
-
7
P
O
WE
R
LOOP
C
OM
+
NO
REMOVE
CONNECTOR
TO RESET
Di
abl
o
Cont
r
ol
s,
Inc
.
St
uc
k
i
n
t
ra
ffi
c
for ov
e
r 37
y
e
a
rs
!
N
C
C
OM
RE
L
A
Y
10
t
o
3
0
V
o
l
t
s
A
C
or D
C
P
OWER
DETE
C
T
DSP
-
7
P
O
W
E
R
LOOP
C
OM
+
NO
REMOVE
CONNECTOR
TO RESET
B
Reverse loop
lead-in wires
are twisted
approx. 6
twists per foot
and are wired
in series.
A
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
PVC conduit to
Control box.
Reverse Loops
Reverse loops prevent the gate
from closing on a vehicle in or
near the gate’s swing pathway.
4 Ft. min. to avoid gate
movement interference.
4 Ft. min. to avoid
reverse loop interference.
4 Ft. min. to avoid gate
movement interference.
FULL
OPEN
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
Type of wiring to be used on ALL external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical,
mechanical, and flammability ratings.
4302-067-B-7-18
16
Black Terminal Lead (- Negative)
Battery
Plug
Connect to
circuit
board.
Leave
Power
Switch
OFF
Black Wire Harness
Red Terminal Lead (+ Positive)
12 Volt
Battery
12 Volt
Battery
DANGER of ELECTRIC
DANGER
of EL
ECTRIC
SHOCK!!
SHOC
K!
!
NEVER touch
the positive and negative
battery wires together!
Negative
(-) Black
Positive
(+) Red
DANGER of ELECTRIC SHOCK!!
Battery Wiring Notes:
Use ONLY 12 Volt batteries.
Batteries are wired in series.
Temperatures will affect the efficiency
of the batteries. The batteries
“optimal” operating temperature is
approximately 77°F (25˚C). They will
not charge as quickly or cycle the gate
operator as many times at lower
temperatures. The lower the tempera-
ture is, the longer it will take for the
batteries to fully charge and the fewer
times the gate operator can be cycled
before the batteries are drained. When
batteries are continually operating at
higher temperatures, they will wear
out quicker. The higher the tempera-
ture is, the shorter the battery life.
Clouds will affect the efficiency of the
batteries charging. The batteries
“optimal” charging capacity is full
sunlight. Charging time will vary
depending on the density of the cloud
cover and the amount of time that the
cloud cover lasts. It will take the
batteries longer to fully charge on
cloudy days. Multiple cloudy days may
not allow the batteries to get fully
charged again after they have been
drained resulting in the system not
being able to cycle the gate until the
sun returns.
DoorKing Recommends:
(2) Two 12 Volt 18 Amp/Hr batteries: Use for applications with
normal usage (60 cycles per day or less).
(2) Two 12 Volt 35 Amp/Hr batteries: Use for applications with
higher usage (60 cycles per day or more).
12 Volt batteries smaller than 18 Amp/Hr are
NOT recommended.
123456789101112131415 16 17 18 19 20
ON
OFF
PUSH TO OPERATE
technician use only
Solar NEG
Solar POS
24 V POS
24 V NEG
Relay COM
Relay N.O.
Full Open
Not Used
Not Used
B
Circuit Board Terminal
12 V Battery Input
DO NOT cycle the gate operator at this time.
Damage could occur to the gate and operator.
Battery Replacement Note: DoorKing HIGHLY
recommends replacing the batteries every two years
because of normal battery deterioration.
2.6 Battery Wiring
FULL
OPEN
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
4302-067-B-7-18
17
2.7 Solar Panel Wiring
ONLY Use (1) One 24 Volt Solar Panel!
The 24 volt - 10 watt or 20 watt solar panel must be correctly
installed for the system to function correctly. See Section 1 in this
manual for more information about concerns, considerations and
recommendations for proper solar panel positioning and mounting.
Solar Power Input Conduit
1 2 3 4 5 6 7 8 9 1011121314151617181920
ON
OFF
B
Reset Button:
• Resets Circuit Board
• Shuts OFF Alarm
Power
Management
Relay
Battery Plug
To Test Operator:
After all power has been connected,
activate the operator by pressing the
Push to Operate” button. This button
will use the Auto-Close timer if turned
ON (SW 1, switch 4 ON).
DO NOT cycle gate operator before
DIP-switches and limit sensors have
been adjusted, damage could occur to
gate and operator (See pages 19-24 to
adjust DIP-switches and limit sensors).
Solar NEG
Solar POS
24 V Pos
24 V Neg
Relay Com
Relay N.O.
Full Open
Not Used
Not Used
DO NOT Connect a
Plug-In Transformer
to the Power Terminals
Power Terminal
PUSH TO OPERATE
technician use only
ON - Normal operation
OFF - Disconnects
battery power from
circuit board. Solar
panel will continue to
charge batteries.
Power Switch
DANGER of ELECTRIC SHOCK!!
Keep sunlight OFF solar
panel while connecting.
How the system’s 24 volt power is managed: When the system is NOT in
use (idle time), the power management relay will shut down power to the
circuit board. Power will continue at the Full Open - Power Terminal,
keeping the overall power drain of the system to a minimum during idle
time. When an access control device - transmitter, key switch, exit loop
or safety opening device is activated while the system is idle, the power
management relay powers up the circuit board to open the gate.
24 Volt Solar Panel Wire
DO NOT connect 12 Volt solar panel. Damage WILL occur!!
DO NOT connect larger volt solar panel. Damage WILL occur!!
DO NOT connect 2 or more solar panels. Damage WILL occur!!
Solar Control Box Requirements:
(1) ONE 24 Volt 10 Watt Solar Panel (P/N 2000-077)
for 18 Amp/Hr Batteries. DO NOT USE 10 watt panel
with the 35 Amp/Hr batteries.
(1) ONE 24 Volt 20 Watt Solar Panel (P/N 2000-076)
for 35 Amp/Hr Batteries. DO NOT USE 20 watt panel
with the 18 Amp/Hr batteries.
CAUTION
White wire to Solar Pos (Hot).
Black wire to Solar Neg (Neutral).
An EXTERNAL ENTRAPMENT PROTECTION
DEVICE MUST be connected or the gate
operator WILL NOT function.
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
4302-067-B-7-18
18
3.1 4302 Circuit Board Description and Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this section should be made after your installation and wiring to the operator(s) is
complete. Whenever any programming or switch setting on the control board are changed, press the reset button for new
settings to take effect.
Auto-close
timer (when
turned ON) SW 1,
switch 4.
Adjust from 1
second (full
counter-clockwise)
to approximately
23 seconds (full
clockwise).
Press reset button to
activate changed control
board settings.
Turns OFF activated
alarm (See page 27).
Cycles the operator when
pressed. Will use Auto-
Close timer when turned
ON. This switch WILL
NOT function when there
is NO power to the circuit
board (Idle time).
TIME
DELAY
123
Auto-Close Timer
DO NOT USE
Reverse Loop Port
DO NOT USE
EXIT Loop Port
Battery Plug
See page 16.
UL 325 Terminal
See page 13.
Set DIP-switches
on the circuit
board to the
desired setting.
See switch-setting
charts on next 2
pages.
DIP-Switches
Dry Relay Contact
Adjust reversing
sensitivity for:
PRIMARY (single) and
SECONDARY (dual)
operators. See page 25.
SEC
PRM
Min Max
Sensitivity
Inherent
Reverse Sensors
OB
CB
Close
Beam
Open
Beam
GND
GND
SW1
1
ON
2
1476-010
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
4302
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SW 2
1
ON
2 3 4
Self test mode is
for bench checks
ONLY. The
operator will
continually cycle
the gate.
The jumper must
be set at normal
mode to function.
Self Test
Mode
Normal
Mode
Self Test
SECONDARY
Operator
See page 12.
PRIMARY
Operator
See page 12.
Input LEDs
Circuit Board Terminal
Limit LEDs
See pages 21-24.
See page 15.
How LEDs Function
Illuminated LEDs Indicates that
low voltage power is being applied
to the circuit board.
Input LEDs should be OFF and will only
illuminate when the input wired to the
corresponding main terminal is activated.
Limit LEDs will only illuminate when the
respective limit sensor has been activated.
Dry relay contacts - Circuit board terminals #10 and #11.
Jumper MUST be set for Normally Open (NO).
DO NOT use Normally Closed (NC).
• Standard reverse loop function, See page 15.
NO
NC
Used to wire external
reverse loop detector.
See page 15.
“Optional” Loop Detectors See pages 14 and 15.
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
NC COM
RELAY
10 to 30 Volts
AC or DC
POWER DETECT
DSP-7
POWER LOOP
COM
+
NO
REMOVE
CONNECTOR
TO RESET
FULL
OPEN
FULL
OPEN
Limit LEDs
See pages 21-24.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38