Contec BX-ACAP12-05 Owner's manual

Type
Owner's manual

Contec BX-ACAP12-05 is a switching AC adapter with a universal input voltage range of 100-240VAC and an output of +12VDC at 3.75A. It is compatible with Contec models BX-2x0-DCxxxx, BX-2x0D-DCxxxx, and IPC-BX955D-DCxxx. The adapter has a compact design and comes with a 2m AC power cable and a 1.8m DC cable. It features built-in protection against overvoltage, overcurrent, and short circuit, ensuring safe and reliable operation.

Contec BX-ACAP12-05 is a switching AC adapter with a universal input voltage range of 100-240VAC and an output of +12VDC at 3.75A. It is compatible with Contec models BX-2x0-DCxxxx, BX-2x0D-DCxxxx, and IPC-BX955D-DCxxx. The adapter has a compact design and comes with a 2m AC power cable and a 1.8m DC cable. It features built-in protection against overvoltage, overcurrent, and short circuit, ensuring safe and reliable operation.

1 BX-ACAP12-05
SWITCHING AC ADAPTER 12VDC
BX-ACAP12-05 User’s Guide
CONTEC CO.,LTD.
Thank you for purchasing this product.
This product is the AC adapter for input: 100 - 240VAC and output: +12VDC 3.75A. This product can
be used for the CONTEC’s following models. (It is not possible to use it excluding the target model.)
- BX-ACAP12-05
BOX Computer: BX-2x0-DCxxxx, BX-2x0D-DCxxxx, IPC-BX955D-DCxxx
Package Contents
The product you have purchased consists of the following items. Be sure that you have them all. If you
find any item either missing or damaged, please contact the sales representative you purchased the
product from.
BX-ACAP12-05
Name Pcs.
AC adapter 1
AC power cable (100VAC, 2pin) 1
User
s Guide
(this document)
1
* This AC power cable is for the voltage of the 100VAC or less.
In the case that the voltage that this cable uses do not match you need to prepare other cable particularly.
Using method
- Make sure that the AC power cable is not plugged into a wall outlet.
- Connect the AC power cable to the main body of AC adaptor connector (CN1).
- Connect the DC cable of AC adaptor with the DC power supply connector.
- Plug the AC power cable into a wall outlet.
* This product has no power switch. When turning off, unplug the AC power cable from the wall
outlet.
AC adapter
AC power cable
(100VAC, 2pin)
Users
Guide
BX-ACAP12-05
User’s Guide
BX-ACAP12-05
2
Specifications
Requirement Description
Power supply space
Rated input voltage 100VAC to 240VAC (continuous input), 50 to 60Hz
Permissible input voltage 90VAC to 264VAC (continuous input), 50 to 60Hz
Input current 1.5A Max. (AC IN 100V)
Rated output voltage +12VDC ±5%
Rated output current 3.75A (Max.)
Permissible momentary blackout 5ms or less
Dielectric strength (between Input P and S) 3.0kVAC for one second
Insulation resistance (between P and S) Greater than 50MΩ (500VDC)
Environmental specs
Temperature Operating : 0 to 40 °C, non operating : - 20 to + 80 °C
Operating : 20 to 80%RH (No condensation)
Humidity
Non operating : 10 to 90%RH (No condensation)
Floating dust particles Not to be excessive
Corrosive gases None
Vibration resistance 10 to 55Hz / 2.0G
Construction
Length of cable AC Power cable : 2.0m, DC cable : 1.8m
External dimensions (mm) 50.5(W) x 114.5(D) x 28(H) (not include projection of cable)
Weight Main body : 250g, AC power cable : 200g
MTBF 200,000H or more
Longevity 10,000H (temperature 25 °C 100% at the load)
External Dimensions and Component Identification
BX-ACAP12-05
User’s Guide
3 BX-ACAP12-05
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
Storage
When storing this product, keep it in its original packing form.
- Wrap it in the packing material, and then put it in the box.
- Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Handling Precautions
WARNING
Indicates dos and don'ts that are assumed to result in possible death or serious injury if they are
inappropriately handled ignoring this icon.
- Do not use the product in locations exposed to a flammable or corrosive gas. It may cause explosion,
fire, electrical shock, or malfunction.
- If you sense abnormality (smoke, odor, or noise), immediately unplug the power cord from the wall
outlet and contact the CONTEC sales representative or sales office.
- To avoid electrocution do not use the product with a wet hand.
- Be sure to connect the product to the stipulated power supply voltage. Connecting to a different
voltage might cause a fire or electrical shock.
- Do not use the product with the other power device. It may cause fire or malfunction.
- When the cable or main body is damaged, stop using and repair it immediately. Using it as it is may
cause fire, electrical shock or malfunction.
- Never disassemble or modify the product or replace its parts in order to prevent electrical shock,
fire, or malfunction. CONTEC reserves the right to refuse servicing the product modified by the
user. When any part of the product needs to be replaced at the expiration of its life or due to
breakdown, please contact the CONTEC sales representative or sales office.
- Use the product with the specified models by the CONTEC. Not doing so may cause fire or
malfunction.
- Use the product in the specified operating condition (temperature and humidity)
BX-ACAP12-05
User’s Guide
Copyright 2011 Contec co., ltd. All Rights Reserved.
CONTEC CO.,LTD. January 2011 Edition
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan
Japanese http://www.contec.co.jp/
English http://www.contec.com/ NA01174 (LYMJ391)
Chinese http://www.contec.com.cn/ [01192011]
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CAUTION
Indicates dos and don'ts that are assumed to result in possible injury or property damage if they are
inappropriately handled ignoring this icon.
- Do not use or store the product in a location exposed to extremely high or low temperature or
susceptible to a rapid temperature change. Example:
- Exposure to direct sun - In the vicinity of a heat source
- When unplugging the cable, hold the plug. Holding and pulling the cable itself can cause a failure
such as discontinuity.
- To clean the product wipe it gently with soft cloth damp with either water or mild detergent.
Do not use chemicals or a volatile solvent, such as benzene and thinner, to prevent peeling or
discoloration of the paint.
- When transporting the product, provide adequate measures to protect it from vibration or shock.
- No part of this document may be copied or reproduced in any form by any means without prior
written consent of CONTEC CO., LTD.
- The information in this document is subject to change without notice.
- All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
- Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Contec BX-ACAP12-05 Owner's manual

Type
Owner's manual

Contec BX-ACAP12-05 is a switching AC adapter with a universal input voltage range of 100-240VAC and an output of +12VDC at 3.75A. It is compatible with Contec models BX-2x0-DCxxxx, BX-2x0D-DCxxxx, and IPC-BX955D-DCxxx. The adapter has a compact design and comes with a 2m AC power cable and a 1.8m DC cable. It features built-in protection against overvoltage, overcurrent, and short circuit, ensuring safe and reliable operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI