  • Hello! I am an AI chatbot trained to assist you with the SolaHD GL Series Single and Multi-Output Switches User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
GL SERIES SINGLE aNd MULTI OUTPUT SWITCHERS – Product Guide
GL SERIES: SINGLE AND MULTI OUTPUT SWITCHERS
The GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500
watts for use in various industrial applications requiring standard footprint size and very high reliability. These low-prole
AC/DC switchers offer universal input voltage with no switches or jumpers, ideal for higher volume worldwide applications.
ALL MODELS FEATURE
• Industry standard footprints
• Universal input
• Full power to +50°C
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Built-in EMI Filtering
• Extensive safety approvals
• Derated operation to +70°C
• ±2% regulation on main output
• 250 VA and higher VA size enclosed
• Two year limited warranty
MANY MODELS FEATURE
• EN61000-3-2 Compliance
• Supervisory outputs (5 V/12 V)
• Wide-adjustable oating fourth output
• Single wire current share
• Medical approvals
• Remote Sense
• Adjustable main output
• Power Fail and DC Good signals
• Wide-adjustable on single output models
CERTIFICATIONS AND COMPLIANCES
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
Recognized Component, ITE
- UL 60950-1
Certied, ITE
- CSA C22.2 CSA 60950-1
- IEC60950-1
E137632
GL SERIES: OPTIONS AND CONNECTION KITS
COVER AND BRACKET OPTIONS
• Cover options can be ordered separately. They are designed
to simplify mechanical integration of the power supplies into
systems and add an extra measure of electrical safety for
service personnel.
• Bracket kits can be ordered separately for GL110 series only.
It is needed when the cover option is used.
COVER AND BRACKET OPTIONS
Catalog Number Description
GLX40 Enclosure kit for the GL20 and GL40
GLX50 Enclosure kit for the GL50 and GL100-M
GLX60 Enclosure kit for the GL60
GLX110-B Bracket kit for the GL110
GLX110-C Cover kit for the GL110
GLX120 Enclosure kit for the GLS120 and GLQ120
GLX140-C Cover kit for the GLQ140
GLX140-CF Cover with top fan kit for the GLQ140
GLX150-C Cover kit for the GL150
GLX17Q-C Cover kit for the quad output GL170
GLX17S-C Cover kit for the single output GL170
GLX200 Enclosure kit for the GL200-M
GLX250-CEF Cover end fan kit for the GL250
GLX250-CF Cover with top fan kit for the GL250/350
MATING CONNECTORS
• Can be ordered separately for units with Molex connection
• Kits include mating housing and pins for input and output
connection
MATING CONNECTORS
Catalog Number Description
70-841-006
GL40, GL50 and GL60 Mating Connector Kit
70-841-007
GLS110 Mating Connector Kit
70-841-008
GLQ110 Mating Connector Kit
70-841-020
GLS120 Mating Connector Kit
70-841-012
GLQ123 Mating Connector Kit
70-841-017
GLQ142 Mating Connector Kit
70-841-009
GLS150 Mating Connector Kit
70-841-010
GLQ150 Mating Connector Kit
70-841-015
GLQ170 Mating Connector Kit
70-841-016
GLS170 Mating Connector Kit
70-841-005
GLX250 Mating Connector Kit
78-841-018
GLS200-M Mating Connector Kit
78-841-025
GLS100-M Mating Connector Kit
70-841-011
GLS350 Mating Connector Kit
70-841-024
GLS500 Mating Connector Kit
GL SERIES: SPECIFICATIONS
GL20, GL40 GL50 GL60, GL110
GLQ120,
GLS120
GL140 GL150 GL170 GL250, GL350 GL500
Input
Input
Voltage
1
85 - 264 Vac;
120 - 300 Vdc
90 - 264 Vac
127 - 300 Vdc
85 - 264 Vac
120 - 300 Vdc
85 - 132 Vac
or 170 - 264 Vac
auto-selected.
220 - 300 Vdc
85 - 264 Vac
120 - 300 Vdc
85 - 264 Vac
Frequency 47-63 Hz , 400± 40 Hz 47-63 Hz
Inrush
Current
GL20: <15A peak
@ 115 Vac; <30A
peak @ 230 Vac,
cold start @ +25°C.
GL40: <18A peak
@ 115 Vac; <36A
peak @ 230 Vac,
cold start @ +25°C
<60A peak
@ 230 Vac,
cold start @ +25°C
<18A peak
@ 115 Vac,
<36 A peak
@ 230 Vac,
cold start @
+25°C
GLQ120:
38 A max., cold
start @ +25°C
GLS120:
40A max., cold
start @ +25°C
38 A max, cold start @ 25°C
GL250:
20 A max.,
cold start @ 25°C.
GL350:
38 A max., cold
start @ +25°C.
50 A max.,
cold start
@ +25°C
Efficiency
70% typical
at full load
80% - 85%
typical
at full load
70% typical
at full load
GLQ120: 65%
typical at full
load. GLS120:
80% typical
at full load
75% typical at full load
85% typical
at full load,
nominal line
EMI/RFI FCC Class B ; CISPR 22 Class B ; EN55022 Class B
Safety
Ground
Leakage
Current
Non-Medical:
<0.5 mA
Medical: < 75 µA
@ 50/60 Hz,
264 Vac input
Non-medical:
<0.5mA
Medical: 275 µA
@ 50/60 Hz;
264 Vac input for
Class I; <0.25mA
@ 50/60 Hz;
264 Vac input for
Class 2 (for single
output only)
Non-Medical:
<0.5 mA
Med ica l:
< 75µA
@ 50/60 Hz;
264 Vac input
GLQ120:
<1 mA
@ 50/60 Hz,
264 Vac input.
GLS120: 0.5mA
@ 50/60 Hz, 264
Vac input
1.0 mA
@ 50/60
Hz, 264 Vac
input
<0.5 mA
@ 50/60 Hz, 264
Vac input
Non-Medi-
cal: 0.1 mA
Medical:
< 250 µA
1.0 mA
@ 50/60
Hz, 264 Vac
input
<0.5 mA
@ 50/60 Hz,
264 Vac input
Non-Medical:
<0.5 mA
Medical:
<0.3mA
@ 50/60 Hz,
264 Vac
input
Output
Power Refer to the selection table
Adjustment
Range on
Main Output
-5, +10%
minimum
±20% minimum
for single output
only models
GL60: -5, +10%
minimum
GL110: ±5%
on main, 5-25 V
on 4
th
output
±5% minimum
3.3 - 5.5V on
main; -12 -
15V on 3rd
output 3.3 -
25 V on 4th
output
±5% minimum
on main, 5-25 V
on fourth output
2:1 wide
ratio
minimum
2:1 wide ratio ±5%
Hold-up
Time
20 ms @ full load,
115 Vac nominal
line
10/20 ms 115/230
Vac Input line
20 ms @ full load, 115 Vac nominal line
Overload Short circuit protection on all outputs. Primary overload protection
Overvoltage
Protection
5 V output; 5.7 to
6.7 Vdc. Other
outputs 10% to
25% above
nominal output
30-50% above
nominal output
5 V output; 5.7
- 6.7 Vdc. Other
outputs 10% to
25% above
nominal output
3.3 V and 5 V
output: 20% to
35%
above nominal
output
Tracks out-
puts 1, 3 & 4;
10 to 35%
5 V output: 5.7
to 6.7 Vdc.
Other out-
puts10% to 25%
above nominal
output
10% to 40%
above
nominal
output
5 V output: 5.7
to 6.7 Vdc.
Other outputs
10% to 25% above
nominal output
20-35%
above
nominal
output
Remote
Sense
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection protected
General
Temperature
2
Storage: -40°C to +85°C; Operating: +0° to +50°C ambient. Derate each output 2.5% per degree from +50° to +70°C, -20°C start up.
Electro
-magnetic
Susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing up to 95% RH
Vibration
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
(2 G peak 8 Hz to 500 Hz for GL500)
MTBF >550,000 hours demonstrated at full load and 25°C ambient conditions
Safety
Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certicate and report; CE Mark (LVD)
Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-1
Notes:
1. Proper circuit protection required when operating with a DC input voltage.
2. Regulation and ripple may deviate from the spec at -20°C start up.
GL SERIES: SELECTION TABLE
Catalog
Number
Output 1 Output 2 Output 3 Output 4 Case
3
Pin
Assignments
Mating
Connectors
3
GL20
[40 W] 25 W
GLS22 5 V @ 5 A [8 A]
6
- - -
1
1A
1B
GLS23 12 V @ 2.1 A [3.3 A]
6
- - -
GLS24 15 V @ 1.7 A [2.7]
6
- - -
GLT22 5 V @ 3 A [4 A]
7
12 V @ 1.5 A [2 A]
7
-12 V @ 0.5 A [0.7 A] -
2A
GLT23 5 V @ 4 A [5 A]
7
12 V @ 0.5 A [0.7 A] -12 V @ 0.5 A [0.7 A] -
GLT24 5 V @ 3 A [4 A]
7
12 V @ 1.5 A [2 A]
7
-5 V @ 0.5 A [0.7 A] -
GLT25 5 V @ 3 A [4 A]
7
15 V @ 1.5 A [2 A]
7
-15 V @ 0.5 A [0.7 A] -
GL40
[55 W] 40 W
1
[40 W] 25 W
2
GLS42
4
5 V @ 8 A [11 A]
6
- - -
1
3A
1B
GLS43
4
12 V @ 3.3 A [4.5]
6
- - -
GLS44
4
15 V @ 2.6 A [3.6 A]
6
- - -
GLS45
4
24 V @ 1.6 A [2.3 A]
6
- - -
GLT42
4
5 V @ 4 A [5 A]
7
12 V @ 2 A [2.5 A]
7
-12 V @ 0.5 A [0.7 A] -
4A
GLT43 5 V @ 6 A [8 A]
7
12 V @ 0.5 A [0.7 A] -12 V @ 0.5 A [0.7 A] -
GLT44 5 V @ 4 A [5 A]
7
12 V @ 2 A [2.5 A]
7
-5 V @ 0.5 A [0.7 A] -
GLT45
4
5 V @ 4 A [5 A]
7
15 V @ 2 A [2.5 A]
7
-15 V @ 0.5 A [0.7 A] -
GLT46 5 V @ 4 A [5 A]
7
24 V @ 1 A [1.5 A]
7
+12 V @ 0.5 A [0.7 A] -
GL50
[50 W] 50 W
GLT52
4
5 V @ 8 A
7
12 V @ 3 A
7
-12 V @ 0.5 A -
2 5A 2BGLT53
4
5 V @ 8 A
7
15 V @ 2.4 A
7
-15 V @ 0.5 A -
GLT54
4
5 V @ 8 A
7
24 V @ 1.5 A
7
12 V @ 0.5 A -
GL50
[60 W] 60 W
GLS52
4
5 V @ 11 A - - -
3 6A 2B
GLS53-I
5
12 V @ 5A - - -
GLS53
4
12 V @ 5 A
6
- - -
GLS54
4
15 V @ 4 A
6
- - -
GLS55
4
24 V @ 2.5 A
6
- - -
GLS58
4
48 V @ 1.25 A
6
- - -
GL60
[80 W] 60 W
1
[60 W] 40 W
2
GLS62 5 V @12 A [16 A]
6
- - -
4
7A 3B
GLS63
4
12 V @ 5 A [6.7 A]
6
- - -
GLS64
4
15 V @ 4 A [5.3 A]
6
- - -
GLS65
4
24 V @ 2.5 A [3.3 A]
6
- - -
GLT62
4
5 V @ 7 A [8 A]
7
12 V @ 3 A [3.5 A]
7
-12 V @ 0.7 A [1 A] -
8A 4B
GLT63
4
5 V @ 7 A [8 A]
7
15 V @ 2.8 A [3.3 A]
7
-15 V @ 0.7 A [1 A] -
GLT64 5 V @ 7 A [8 A]
7
12 V @ 3 A [3.5 A]
7
-5 V @ 0.7 A [1 A] -
GLT65 5 V @ 7 A [8 A]
7
24 V @ 1.5 A [2 A]
7
+12 V @ 0.7 A [1 A] -
GL110
[110 W] 80 W
1
[90 W] 70 W
2
GLS114 15 V @ 5.3 A [7.3 A]
6
- - -
5
9A 5B
GLS115 24 V @ 3.3 A [4.6 A]
6
- - -
GLQ112 5 V @ 9 A [11 A]
8
12 V @ 4.5 A [5 A} -12 V @ 0.7 A [1 A] ±5-25 V @ 2.5 A [3 A]
6
10A 6BGLQ113 5 V @ 9 A [11 A]
8
15 V @4.5 A [5 A] -15 V @ 0.7 A [1 A] ±5-25 V @ 2.5 A [3 A]
6
GLQ114 5 V @ 9 A [11 A]
8
12 V @ 4.5 A [5 A] -12 V @ 0.7 A [1 A] 24 V @ 3.5 A [4.5 A]
8
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Refer to GL Series Dimensions and the sections that follow
4. Add “-M” suffix for the medical model numbers
5. Industrial version - Operating temperature -40°C to +80°C
6. Floating output
7. Approximate minimum loading: 10%
8. Approximate minimum loading: 23%
GL SERIES: SELECTION TABLE
Catalog
Number
Output 1 Output 2 Output 3 Output 4 Case
5
Pin
Assignments
5
Mating
Connectors
5
GLQ120
[120 W] 70 W
GLQ123 3.3 V @ 14 A [25 A] 5 V @ 12.5 A [24 A]
9
+12 V @ 1 A [2 A] -12 V @ 0.5 A [1 A] 6 11A 7B
GLS120
[130 W] 80 W
GLS122 5 V @ 16 A [26 A] 8 - - -
7 12A 8B
GLS123 12 V @ 6.6 A [10.8 A]
8
- - -
GL140
[145 W] 80 W
GLQ142
5 V @ 12 A [25 A]
(3.3 V - 5 V)
12 V @ 5 A [6 A]
-12 V @ 1 A [1.5 A]
(-12 V - 15 V)
±3.3-25 V @ 1.5 A
[4.5 A]
8 10
8 13A 9B
GL150
[150 W] 110 W
1
[130 W] 75 W
2
GLS152 5 V @ 22 A [30 A]
8
- - -
9 14A 10B
GLS153
12 V @ 9.1 A [12.5 A]
8
(12 V- 15 V)
- - -
GLS155
24 V @ 4.5 A [6.2 A]
8
(24 V - 28 V)
- - -
GLQ152 5 V @ 15 A [22 A]
9
12 V @ 2.6 A [8 A]
11
-12 V @ 2 A [2.5 A]
11
±5-25 V @ 2.5 A [3 A]
8
10 15A 11B
GLQ153 5 V @ 15 A [22 A]
9
15 V @ 4.8 A [6.4 A]
11
-15 V @ 1.6 A [2 A]
11
±5-25 V @ 2.5 A [3 A]
8
GLQ154 5 V @ 15 A [22 A]
9
12 V @ 6 A [8 A]
11
-12 V @ 2 A [2.5 A]
11
24 V @ 3.5 A [4.5 A]
9
GL170
[175 W] 110 W
1
[130 W] 75 W
2
GLS172
6
5 V @ 22 A [35 A]
8
(2.5 V - 6 V)
- - -
11 16A 12B
GLS173
6
12 V @ 9.1 A [15 A]
8
(6 V- 12 V)
- - -
GLS174
6
15 V @ 7.3 A [12 A]
8
(12 V - 24 V)
- - -
GLS175
6
24 V @ 4.5 A [7.5]
8
(24 V - 54 V)
- - -
GLQ172
5 V @ 15 A [30 A]
(3.3 V - 5.5 V)
12 V @ 6 A [8 A]
10
-12 V @ 0.2 A [3 A]
(-12 V - 15 V)
±3.3-25 V @ 2 A [5
A]
8
12 17A 13B
GL250
[250 W]
3 4
GLS253-C 12 V (6-12 V) @ [21 A] - - -
13 18A
14B
GLS255-C 24 V (24-48) @ [10.4 A]
8
- - -
GLQ252-C 5 V @ [35 A]
11
12 V @ [10 A] -12 V @ [6 A] ±5-25 V @ [6 A]
8
14 19A
GLQ253-C 5 V @ [35 A]
11
15 V @ [10 A] -15 V @ [6A] ±5-25 V @ [6 A]
8
GL350
[350 W]
3 4
GLS352-C 5 V (3-6 V) @ [70 A] - - -
15 20A 15B
GLS353-C 12 V (6-12 V) @ [29.2 A]
8
- - -
GLS354-C
15 V (12-24 V)
@ [23.3 A]
8
- - -
GLS355-C
24 V (24-48 V)
@ [14.6 A]
8
- - -
GLS355-CEF
24 V (24-48 V)
@ [14.6 A]
8
- - -
GLQ352-C 5 V @ [50 A]
11
12 V @ [12 A] -12 V @ [6 A] ±3.3-24 V @ [6 A]
8
16 21A 16B
GLQ352-CEF 5 V @ [50 A]
11
12 V @ [12 A] -12 V @ [6 A] ±3.3-24 V @ [6 A]
8
GL500
[500 W] 200 W
GLS503-CF
7
12 V @ 16.6 A [41.7 A] - - -
17 22A 17B
GLS505-CF
7
24 V @ 8.3 A [20.8 A] - - -
GLS508-CF
7
48 V @ 4.2 A [10.4 A] - - -
6. Add “-M” suffix for the medical models numbers.
7. Insert (-M) as in GLS 50x-M-CF for medical model numbers
8. Floating output
9. Approximate minimum loading: 16%
10. Approximate minimum loading: 30%
11. Approximate minimum loading: 10%
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Optional fan cover, See Table 1
4. Optional end fan cover, See Table 1
5. Refer to GL Series Dimensions and the sections that follow
GL SERIES: CASE 1, 2, 3 AND 4 DIMENSIONS
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 Vac input, +25°C unless otherwise stated.
CASE 1
(Weight: 0.5 lbs (0.23 kg) approx.)
CASE 2
(Weight: 0.45 lbs (0.20 kg) approx.)
CASE 3
(Weight: 0.41 lbs (0.18 kg) approx.)
CASE 4
(Weight: 0.75 lbs (0.34 kg) approx.)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L Bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Remote inhibit requires an external 5 V @ 10 mA to activate.
8. Mounting maximum insertion depth is 0.12”.
4.00
(101.6)
1.5
(38.1)
.75 (19.0)
.5625
7.0
(177.8)
6.5
(165.1)
2.5
(63.5)
#6-32 UNC (8 places)
5.5
(139.7)
4.7
(119.6)
M3 (4 places)
SK5
123
5V adj
VR401 VR403
+3.3V
SK6
SK1
COMMON
+5V
M 3.5
(3 places)
MAIN OUTPUTS
5 3 1
SK2SK3SK4
3.3V adj
CASE 5
(Weight: 1.25 lbs (0.57 kg) approx.)
CASE 6
(Weight: 1.38 lbs (0.63 kg) approx.)
(See notes 7 & 8)
GL SERIES: CASE 5 AND 6 DIMENSIONS
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Mounting holes MH1, MH2 and MH3 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. This power supply requires mounting on metal standoffs 0.20” (5 m) in height.
6. Specifications are for convection rating at factory settings at 115 Vac input 25°C unless otherwise stated.
7. Mounting screw maximum insertion depth is 0.12”.
0.20 (5.0)
1.29
(32.8)
2.55
(64.8)
4.55
(115.6)
SK1
6
10
SK3
1
5
SK2
LIVE
NEUTRAL
GRD
P1
1
2
SK3
V
Adjust
POT
3.00
(76.2)
5.00
(127.0)
M3.5 (2 places)
0.15 DIA. (4.0)
(4 places)
(See notes 6 & 7)
CASE 7
(Weight: 0.71 lbs (0.32 kg) approx.)
SK1
N
L
GND
SK6
SK2
MAIN
OUTPUT
(2X) (119.6)
5.50
(2X) (139.7)
7.00
(177.8)
M3 (8 Places)
#6-32 (8 Places)
2.50
(4X) (63.5)
#6-32
6.75
(171.5)
6.36
(161.5)
M3
1.50
(38.1)
(3X) (19.1)
.75
4.71
V4 Adj - Course
#6-32
1.15
(29.1)
M3
.25
(2X) (6.4)
4.00
(101.6)
6
10
1
5
1 6
+12V OUT
COMM
-12V OUT
COMM
V4+
V4-
V4 Adj - Fine
V1 Adj
-CF option
CASE 8
(Weight: 1.63 lbs (0.74 kg) approx.)
GL SERIES: CASE 7 AND 8 DIMENSIONS
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Remote inhibit requires an external 5 V @ 10 mA to activate.
5. Mounting (6-32) maximum insertion depth is 0.12”.
4.25
(108.0)
1.5
(38.1)
.75 (19.0)
.5625
SK3
8.5
(216.0)
7.4
(188.0)
2.5
(63.5)
.875
(22.25)
SK2
SK4
21
7 6 5
5 3 1
SK1
1234
8765
632 (8 )
 



CASE 9
(Weight: 1.75 lbs (0.80 kg) approx.)
CASE 10
(Weight: 1.75 lbs (0.80 kg) approx.)
GL SERIES: CASE 9 AND 10 DIMENSIONS
531
SK4
1
5
610
SK1
+ -
SK3
Voltage Adj
POT
8.5
(216.0)
7.4
(188.0)
6.61
(168.0)
0.55
(14.0)
0.95
(24.0)
1.50
(38.1)
0.75
(19.0)
M3
#6-32
0.88
(22.2)
2.50
(63.5)
1.07
(27.2)
2.11
(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
4.25
(108.0)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Mounting hole M1 is safety ground connection.
CASE 11
(Weight: 0.5 lb (0.23 kg) approx.)
SK4
SK1SK2
4.25
(108.0)
TB2
TB1
SK3
8.5
(216.0)
1
5
6
10
1 2 3 4 5 6 7 8 9
1 3 5
7.4
(188.0)
6.61
(168.0)
0.55
(14.0)
0.95
(24.0)
1.50
(38.1)
0.75
(19.0)
0.88
(22.2)
2.50
(63.5)
1.07
(27.2)
2.11
(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
SK2 SK1
SK3
SK2
SK1
V1 (3V3-5V7)
V1 O/P ADJ.
V4 O/P ADJ.
V3 O/P ADJ.
C
F
V4 (3V3-25V)
V3 (-12V TO -15V7)
LPQ172
LPQ173
TB1
TB3
TB2
TB4
V2
V2
COM
V3
COM
COM
POK
N/C
N/C
V4 V1
SK3
P251
P252
CASE 12
(Weight: 2 lbs (0.91 kg) approx.)
(See notes 1-4)
GL SERIES: CASE 11 AND 12 DIMENSIONS
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are at factory settings.
4. To enable normally closed remote inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
5.0 (127.0)
2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
3
1
12345678
3 2 1
5
 

 1
.
4

632 (4 )
5.46
(138.6)
8.52
(216.4)
3 (4 )
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14)
1.30
(33.0)

()

 

()

 
10.32
(262.0)
7

 
10.0
10.0
3
632 
(2 )
3
10.0
632 
(2 )
.24 (6.1)
632 (2 )
 
632 (3 )
CASE 13
(Weight: 2.6 lbs (1.19 kg) approx.)
CASE 14
(Weight: 3.1 lbs (1.41 kg) approx.)
5.0 (127.0)
2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK3
SK1
12345678
3 2 1
SK5
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK4
FAN
#6-32 UNC (8 places)
5.46
(138.6)
8.52
(216.4)
M3 (8 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14)
1.30
(33.0)
Optional
(-CF)
Cover
with Fan
Optional
(-CEF)
Cover
with fans
10.32
(262.0)
SK7
FAN
AC Inlet
10.0
10.0
10.0
M3
#6-32 UNC (2 places)
#6-32 UNC
(2 places)
#6-32 (2 places)
M3 (2 places)
4th O/P ADJ.
.24 (6.1)
6-32 (2 places)
Main Output
6-32 (3 places)
SK2
6 5 4 3 2 1
M3
(6 places)
M3
GL SERIES: CASE 13 AND 14 DIMENSIONS
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are at factory settings.
4. To enable normally closed remote inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
9.0
(228.6)
6.64
(168.6)
.42(8.0)
.9
(20)
(6)

12468910
6



1
.


62(8)
.46
(18.6)
8.2
(216.4)
(4)
.68
(9.6)
.1
(80)
2.1
()
.
(14)
1.0
(.0)
()


4
.0(12.0)
2.
(6.)
1.18(0.0)
.64
(92.)

()


.24(6.1)
62(2)

10.4
(26.0)
.0(12.0)
21
1
62()
CASE 15
(Weight: 3.6 lbs (1.64 kg) approx.)
5.0 (127.0)
2.5
(63.5)
1.18 (30.0)
3.5
(88.9)
Optional
(-CEF)
Cover
with fan
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
1
3 2 1
5 5 a
ve -ve
erinal
lo 1
4 fan
6-32 C (8 plae)
5.46
(138.6)
8.52
(216.4)
3.68
(93.6)
3.15
(80)
2.17
(55)
.55
)
1.30
(33.0)
Optional
(-CF)
Cover
with Fan
10.78
(273.8)

.24 (6.1)
6-32 (2 plae)
ain Otpt
3
12345678910
6
2
6 5 4 3 2 1
6-32 (3 plae)
(6 plae)
op pot.
4 at
otto pot.
1 at
CASE 16
(Weight: 4 lbs (1.8 kg) approx.)
GL SERIES: CASE 15 AND 16 DIMENSIONS
CN1
SK7
SK8
(CN403)
V out adj.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are at factory settings.
4. Mounting maximum insertion depth is 0.12”.
CASE 17
(Weight: 3.016 lbs (1.18 kg) approx.)
GL SERIES: CASE 17 DIMENSIONS
1A 2A
3A * 4A
5A *
Connector GLS22 GLS23 GLS24
SK1
PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V
PIN 2 +5 V +12 V +15 V
PIN 3 +5 V +12 V +15 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201
PIN 1 +Sense
PIN 2 -Sense
Connector GLT22 GLT23 GLT24 GLT25
SK1
PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V +12 V +12 V +15 V
PIN 2 +5 V +5 V +5 V +5 V
PIN 3 +5 V +5 V +5 V +5 V
PIN 4
Common
PIN 5
Common
PIN 6 -12 V -12 V -5 V -15 V
SK201
PIN 1 +Sense
PIN 2 -Sense
Connector GLS42 GLS43 GLS44 GLS45
SK1
PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V +24 V
PIN 2 +5 V +12 V +15 V +24 V
PIN 3 +5 V +12 V +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201
PIN 1 +Sense
PIN 2 -Sense
Connector GLT52 GLT53 GLT54
SK1
PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 Common
PIN 4 Common
PIN 5 -12 V -15 V +12 V
PIN 6 +12 V +15 V +24 V
Connector GLT42 * GLT43 GLT44 GLT45 GLT45 *
SK1
PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V +15 V +24 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V -5 V -15 V +12 V
SK201
PIN 1 +Sense
PIN 2 -Sense
GL SERIES: 1A, 2A, 3A, 4A AND 5A PIN ASSIGNMENTS
* Same Mating Connectors are attributed to both standard and medical models.
6A *
7A
8A
9A 10A
Connector GLS52 GLS53 GLS54 GLS55 GLS58
SK1
PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V +24 V +48 V
PIN 2 +5 V +12 V +15 V +24 V +48 V
PIN 3 Common
PIN 4 Common
PIN 5 -Sense
PIN 6 +Sense
Connector GLS62
GLS63
(GLS62-M)
GLS64
(GLS63-M)
GLS65
SK1
PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 5 V +12 V +15 V +24 V
PIN 2 5 V +12 V +15 V +24 V
PIN 3 5 V +12 V +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201
PIN 1 +Sense
PIN 2 -Sense
Connector GLT62 GLT63 GLT64 GLT65
SK1
PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +12 V +15 V +12 V +24 V
PIN 2 +5 V +5 V +5 V +5 V
PIN 3 +5 V +5 V +5 V +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V -15 V -5 V +12 V
SK201
PIN 1 +Sense
PIN 2 -Sense
Connector GLS114 GLS115
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2
PIN 1 +15 V +24 V
PIN 2 +15 V +24 V
PIN 3 +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
PIN 7 Common
PIN 8 +15 V +24 V
PIN 9 +15 V +24 V
SK201
PIN 1 +Sense
PIN 2 -Sense
SK202
PIN 1 Power OK
PIN 2 Ground
Connector GLQ112 GLQ113 GLQ114
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
PIN 7 Common
PIN 8 +12 V +15 V +12 V
PIN 9 +12 V +15 V +12 V
PIN 10 -12 V -15 V -12 V
PIN 11 +5-25 V +5-25 V +24 V
PIN 12 -5-25 V -5-25 V Common
SK201
PIN 1 +Sense
PIN 2 -Sense
SK202
PIN 1 Power OK
PIN 2 Ground
11A
12A
Connector GLQ123
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK5
PIN 1 +12 V
PIN 2 Common
PIN 3 -12 V
SK6
PIN 1 3.3 V Single Wire Parallel
PIN 2 -3.3 V Sense
PIN 3 +3.3 V +Sense
PIN 4 5 V Single Wire Parallel
PIN 5 Common
PIN 6 +5 V Sense
PIN 7 -5 V Sense
PIN 8 + Inhibit
PIN 9 - Inhibit
PIN 10 Power Fail
Connector GLS120
SK1
PIN 1 Neutral
PIN 3 Line
SK2
TB-1 Common
TB-2 Main Output
SK3
PIN 1 +V1 Remote Sense
PIN 2 -V1 Remote Sense
PIN 3 +Remote Inhibit
PIN 4 -Remote Inhibit
PIN 5 +Power Fail
PIN 6 Common
PIN 7 Single Wire Parallel
PIN 8 +12 V
PIN 9 12 V Common
PIN 10 +5 V Standby
GL SERIES: 6A, 7A, 8A, 9A, 10A, 11A AND 12A PIN ASSIGNMENTS
* Same Mating Connectors are attributed to both standard and medical models.
14A
15A
16A *
Connector GLS152 GLS153 GLS155
SK1
PIN 1 Inhibit -ve
PIN 2 Inhibit +ve
PIN 3 VCC
PIN 4 No Connection
PIN 5 Common
PIN 6 -Sense
PIN 7 +Sense
PIN 8 Current Share
SK2
PIN 5 Common
PIN 6 Pin Removed
PIN 7 Power OK
SK3
TB-1 Common
TB-2 +5 V
+12 V to
+15 V
+24 V to
+28 V
SK4
PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLQ152 GLQ153 GLQ154
SK1
PIN 1 Inhibit -ve
PIN 2 Inhibit +ve
PIN 3 +12 V +15 V +12V
PIN 4 No Connection
PIN 5 Common
PIN 6 -Sense
PIN 7 +Sense
PIN 8 I Share
SK2
PIN 1,2 +12 V +15 V +12 V
PIN
3,4,5
Common Common Common
PIN 6 -12 V -15 V -12 V
PIN 7 Power OK
PIN 8 +5 V to +25 V (Float) +24 V
PIN 9 Common (Float) Common
SK3
TB-1 Common
TB-2 +5 V
SK4
PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLS17x
SK1
PIN 1 +12 V
PIN 2 5 V Standby
PIN 3 Common
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 Remote Inhibit
PIN 9 DC Power Good
PIN 10 Power OK
SK2
TB-1 Common
TB-2 Main Output
SK3
PIN 1 Ground
PIN 2 Line
PIN 5 Neutral
17A
18A
Connector GLQ172 GLQ173
SK1
PIN 1 No Connection
V4 Single Wire
Parallel
PIN 2 5 V Standby
PIN 3 No Connection +V4 Sense
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 Remote Inhibit
PIN 9 DC Power Good
PIN 10 Power OK
SK2
PIN 1,2 +12 V
PIN
3,4,5
Common
PIN 6 -12 V
PIN 7 Power OK
PIN 8
+3.3 V to +25
V (Float)
No Connection
PIN 9
Common
(Float)
No Connection
SK3
TB-1,3 Common
TB-2 +5 V (3.3 V to 5.5 V)
TB-4 No Connection
+5 V (3.3 V to
5.5 V)
SK4
PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLS250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O)
PIN 4 Remote Inhibit (N.C)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4
PIN 1
+Fan’s power source
(12 V @ 500 mA)
PIN 2
-Fan’s power source
(12 V @ 500 mA)
SK5
PIN 1
+Supervisory output supply
(5 V @ 100 mA)
PIN 2
-Supervisory output supply
(5 V @ 100 mA)
SK7
PIN 1
+Fan’s power source
(12 V @ 500 mA)
PIN 2
+Fan’s power source
(12 V @ 500 mA)
13A
Connector GLQ142
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2
PIN 1 +12 V
PIN 2 Common
PIN 3 -12 V
PIN 4 Common
PIN 5 +5 V to +25 V (Float)
PIN 6 Common (Float)
SK4
TB-1 Common
TB-2 +5 V
SK3
PIN 1 No Connection
PIN 2 DC Power Good
PIN 3 No Connection
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 +Inhibit
PIN 9 -Inhibit
PIN 10 Power Fail
GL SERIES: 13A, 14A, 15A, 16A, 17A AND 18A PIN ASSIGNMENTS
* Same Mating Connectors are attributed to both standard and medical models.
19A
21A
20A
Connector GLQ350
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK2
PIN 1 +12 / 15 V
PIN 2 Common
PIN 3 Common
PIN 4 -12 / 15 V
PIN 5 3.3-25 V RET Float
PIN 6 3.3-25 V Float
SK3
PIN 1 +Sense V4
PIN 2 -Sense V4
PIN 3 +Sense V1
PIN 4 -Sense V1
PIN 5 Power OK
PIN 6 Current Share
PIN 7 DC Power Good
PIN 8 Inhibit (N.O.)
PIN 9 Inhibit (N.C.)
PIN 10 Common
SK4
PIN 1 +Fan 1 (12 V @ 150 mA)
PIN 2 -Common
SK5
PIN 1 +5 V aux (5 V@ 100 mA)
PIN 2 -Common
SK6
PIN 1 +Fan 2 (12 V @ 150 mA)
PIN 2 -Common
Connector GLS350
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK3
PIN 1 No Connection
PIN 2 No Connection
PIN 3 +Sense
PIN 4 -Sense
PIN 5 Power OK
PIN 6 Current Share
PIN 7 DC Power Good
PIN 8 Inhibit (N.O.)
PIN 9 Inhibit (N.C.)
PIN 10 Common
SK4
PIN 1 +5 V aux (5 V @ 100 mA)
PIN 2 -Common
SK5
PIN 1 +Fan 1 (12 V @ 150 mA)
PIN 2 -Common
SK6
PIN 1 +Fan 2 (12 V @ 150 mA)
PIN 2 -Common
22A *
Connector GL500
CN1
PIN 1 Line
PIN 3 Neutral
PIN 5 Ground
SK7
PIN 1 V1 Single Wire Parallel
PIN 2 -Remote Sense
PIN 3 +Remote Sense
PIN 4 5 VSB (Standby)
PIN 5 5 VSB Return
PIN 6 +12 V
PIN 7 Common
PIN 8 Inhibit
PIN 9 DC Power Good
PIN 10 Power Fail (POK)
CN403
PIN 1 5 V_I
2
C
PIN 2 Ground
PIN 3 A2
PIN 4 A0
PIN 5 SVCC2_OR
PIN 6 I
2
C_SDA
PIN 7 I
2
C_SLC
PIN 8 A1
PIN 9 No Connection
PIN 10 +12V_RTN_CTRL
Adjustment Potentiometers
P1
+V1 Output Adjust
Connector GLQ250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK2
PIN 1 +12 / 15 V
PIN 2 Common
PIN 3 Common
PIN 4 -12 / 15 V
PIN 5 5-25 V RET Float
PIN 6 5-25 V Float
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O.)
PIN 4 Remote Inhibit (N.C.)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4
PIN 1
+Fan’s power source
(12 V @ 500 mA)
PIN 2
+Fan’s power source
(12 V @ 500 mA)
SK5
PIN 1
+Supervisory output supply
(5 V @ 100 mA)
PIN 2
-Supervisory output supply
(5 V @ 100 mA)
SK7
PIN 1
+Fan’s power source
(12 V @ 500 mA)
PIN 2
+Fan’s power source
(12 V @ 500 mA)
GL SERIES: 19A, 20A, 21A AND 22A PIN ASSIGNMENTS
* Same Mating Connectors are attributed to both standard and medical models.
7B
9B
8B
Connector Kit #70-841-016 includes the following:
(SK1)
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
SK2,3,4: Molex series 19141-0058/0063
(SK5)
±12V:
Molex: 09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK6)
Control
Signals:
Molex: 90142-0010;
PINS: 90119-2110 or
AMP: 87977-3; PINS: 87309-8
Connector Kit #70-841-016 includes the following:
(SK1)
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux
DC Outputs:
Molex: 09-50-8061 (USA)
Molex: 09-91-0600 (UK)
PINS: 08-58-0111
(SK6)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
(SK4)
Main
Output:
Molex: BB-124-08
Connector Kit #70-841-016 includes the following:
(SK1)
AC Input:
Molex 09-50-8031 (connector)
PINS: 08-52-0113
(SK2)
DC Outputs:
Molex series 19141-
0058/0063 Spade lug
(SK3)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
1B * 2B *
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-52-0113
(-0111 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
(-0111 for medical)
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0123
(-0114 for medical)
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-52-0113
DC
Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
3B *
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-58-0111
(-0113 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-58-0113
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0113
4B *
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0113
5B
6B
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8091 (USA)
09-91-0900 (UK)
PINS: 08-58-0111
Remote
Sense/
Power Fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Connector Kit #70-841-016 includes the following:
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8121 (USA)
09-91-1200 (UK)
PINS: 08-58-0111
Remote
Sense/
Power Fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
GL SERIES: 1B, 2B, 3B, 4B, 5B, 6B, 7B, 8B AND 9B MATING CONNECTORS
* Same Mating Connectors are attributed to both standard and medical models.
11B
13B 14B
15B
16B
17B
12B *
Connector Kit #70-841-010 includes the following:
(SK4)
AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC
Outputs/
Power Fail:
Molex: 09-50-8091 (USA)
Molex: 09-91-0900 (UK)
PINS: 08-58-0111
(SK1)
Remote Sense/
Remote Inhibit:
Molex 51110-0851 (USA)
PINS: 503-94-8100
Connector Kit #70-841-016 includes the following:
(SK4)
AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK3)
DC Outputs:
Molex: 19141-0058
(SK1)
Remote Sense/
Remote
Inhibit:
Molex 90142-0010 (USA)
PINS: 90119-2110
Amp: 87977-3
PINS: 87309-8
Connector Kit #70-841-015 includes the following:
(SK4)
AC Input:
Molex 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK3)
Main Out-
put:
Molex series 19141-0058/0063
(SK2) Aux
DC Outputs/
Power Fail:
Molex 09-50-8091 (USA)
Molex:09-91-0900 (UK)
PINS: 08-58-0111
(SK1)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
Connector Kit #70-841-005 includes the following:
SK3 Molex 22-01-1084; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK7 Molex: 22-01-3027 PINS: 08-50-0114
Connector Kit #70-841-011 includes the following:
SK3
Molex 22-01-1104; PINS: 08-70-
0057
SK4
Molex 22-01-3027; PINS: 08-50-
0114
SK5
Molex 22-01-3027; PINS:08-50-
0114
SK6
Molex: 22-01-3027; PINS: 08-50-
0114
Connector Kit #70-841-011 includes the following:
SK3 Molex 22-01-1084; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK6 Molex: 22-01-3027; PINS: 08-50-0114
Connector Kit #70-841-024 includes the following:
SK4,5,6 Molex 19141-0058
SK7
Control
Signals
Molex 90142-0010;
PINS: 90119-2110 or
AMP: 87977-3; PINS: 87309-8
SK8 Molex 22-01-2025; PINS:08-52-0123
CN403
JST PHDR-10VS
PINS: JST 5PHD-002T-PO.5-L/P
or
Landwin 2050 S1000;
PINS: 2053T011P
10B
Connector Kit #70-841-009 includes the following:
(SK4) AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Power Fail:
Molex: 09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK1)
Remote Sense/
Remote Inhibit:
Molex 51110-0851 (USA)
PINS: 50394-8100
* Same Mating Connectors are attributed to both standard and medical models.