5925 Heisley Road • Mentor, OH 44060-1833
877/CRES COR (273-7267) • 440/350-1100
Fax: 440/350-7267 • www.crescor.com
Humidity Holding
Cabinet
FL-2214
Rev. 8 (2/00) Page 1 of 5
HOW TO INSTALL UNIT:
1. Place cabinet on level floor.
2. Plug end into proper wall outlet.
3. Fill water pan with 10 quarts (9.5 liters) of water.
CAUTION! Use of treated or soft water may be
required for proper operation and to maintain
warranty.
4. Place cabinet in a well ventilated area.
5. Push the switch to "On," turn the "Air" thermostat to
"High" (No.9) and run the unit for one hour.
NOTE: DO NOT PUT IN FOOD!
This step is to burn off manufacturing oils and excess
adhesive.
6. Let the cabinet cool and wipe inside clean with
detergent and hot water before first use.
HOW TO HOLD:
o water needed in pan.
1. Push power switch to "on" Yellow light will come on.
2. Turn "Air" Thermostat to "High Hold" (No.9).
3. Pre-heat for 30 minutes.
4. Turn "Air" thermostat to temperature needed.
NOTE: 180°F (82°C) is approximately No.8. Proper
food-holding temperature is 140°F (60°C) or higher.
HOW TO HOLD WITH HUMIDITY:
1. Fill water pan (See HOW TO INSTALL UNIT).
2. Push power switch to “On”. Yellow light will come on. 3.
Turn “Air” Thermostat to "High Hold" (No.9).
4. Preheat for 30 minutes.
5. Turn “Humidity” thermostat to "High" (No.9).
6. Turn “Air” thermostat down to temperature needed
WARNING! Air is VERY HOT when door is opened.
HOW TO PROOF:
1. Fill water pan (see HOW TO INSTALL UNIT).
2. Push power switch to "On." Yellow light will come
on. 3. Turn "Air" thermostat to "Proof' (No.1).
4. Turn "Humidity" thermostat to No.3 1/2.
5. Pre-heat for one hour.
6. Put fresh or fully thawed dough into cabinet.
NOTES: Do NOT put frozen dough into cabinet.
These settings will give you approximately 95%
humidity at 95°F (35°C).
NOTE: 180°F (82°C) is approximately No.8. Proper
food-holding temperature is 140°F (60°C) or higher.
7. Put food into cabinet.
8. Turn “Humidity” thermostat down, if needed.
Experiment with different settings to get the exact
temperature and humidity required.
ELECTRICAL SPECIFICATIONS:
MODEL Volts Watts Amps Hertz Phase NEMA
120 1900 15.8 60 1 5-20
H339WSSUA8C
240 1900 7.9 60 1 6-15
OPERATING and MAINTENANCE INSTRUCTIONS
Model H-339-WSS-UA-8C Humidity Holding Hot Cabinet