Hydrel RF7 Retrofit Installation guide

Type
Installation guide
Installation should be performed by a qualified electrician in
accordance with the National Electrical Code and relevant
local codes.
9144 Deering Ave
Chatsworth, CA 91311
Phone: 818-362-9465
www.hydrel.com
©2016 Hydrel
Rev. 12/13/16
RF7I LED Retro
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT
NOTICE. Any dimension on this sheet is to be assumed as a reference
dimension: "Used for information purposes only. It does not govern
manufacturing or inspection requirements." (ANSI Y14.5-1973)
RF7 LED RETROFIT
Retrofit for existing 4430, 4400, 6000, 6100, 6200 Ingrades
1. Remove existing door, gasket and lens - set aside
for later use
2. Remove the existing ballast if fixture is HID
TIP: If existing fixture has a separate ballast compartment (as
shown above) you will need to open that to access the main
power coming into the fixture.
3. Connect the supply wire from the new driver into
the existing power feed using silicone wire nuts
(included).
4. Plug the driver into the bottom of the LED
module and tighten the plug ring to ensure a
water-tight seal.
5.Rest the Support Ring on the inner lip of the
housing.
HYDREL
Ballast
Compartment
Door, Lens &
Gasket
Encapsulated
Driver
Module
LED
Light Engine
ENCAPSULATED
POWER MODULE SEALED LED
FIXTURE
SUPPORT
RING
AIMING
ARM
6.Aim the fixture by loosening the screws on top of
the aiming arms, tilt up to 15°, and tighten the
screws to lock the aiming in place.
7.Replace the lens, gasket and door. Ensure the
sealing surface is clean and free of all debris and
clean out any screw holes as needed. Door
should be tightened using a star pattern as
shown in figure 1 to 50 inch pounds.
RF7 LED RETROFIT
Retrofit for existing 4430, 4400, 6000, 6100, 6200 Ingrades
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT
ASSEMBLY REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF
THE LUMINAIRE’S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED,
DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED PERSON.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DE CE
NÉCESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA
CONSTRUCTION ET LE FONCTIONNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET
DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N’EST PAS QUALIFIÉE NE DOIT FAIRE
AUCUNE TENTATIVE D’INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE
LUMINAIRES THAT HAS THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE
PHOTOGRAPHS AND/OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT
KIT DOES NOT EXCEED THE INPUT RATING OF THE LUMINAIRE.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. N’INSTALLER CE
NÉCESSAIRE QUE DANS LES LUMINAIRES DONT LES CARACTÉRISTIQUES DE
CONSTRUCTION ET LES DIMENSIONS SONT CONFORME À CELLES ILLUSTRÉES DANS LES
PHOTOS ET/OU LES DESSINS ET DONT LA PUISSANCE D’ENTRÉE NOMINALE DU NÉCESSAIRE
DE MODERNISATION NE DÉPASSE PAS CELLE DU LUMINAIRE.
WARNING – TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO
EDGES OF SHEET METAL OR OTHER SHARP OBJECTS.
AVERTISSEMENT – AFIN DE PRÉVENIR L’ENDOMMAGEMENT OU L’ABRASION DES CÂBLES,
ÉVITER TOUT CONTACT ENTRE CES DERNIERS ET LE BORD D’UN OBJET TRANCHANT TEL
QU’UNE TÔLE.
“THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE
SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING
JURISDICTION.”
« LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D’UN
LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR