KYLAND Technology SICOM3006 User manual

Category
Network switches
Type
User manual
SICOM3004/SICOM3006User’sManual201105
1
SICOM3004/SICOM3006
Industrial Ethernet Switch
User’s Manual
KYLAND Technology Co., Ltd.
SICOM3004/SICOM3006User’sManual201105
2
SICOM3004/SICOM3006IndustrialEthernetSwitch
User’sManual
Copyright©2009KYLANDTechnologyCO.,LTD.
Allrightsreserved.
Nopartofthisdocumentationmaybeexcerpted,reproduced,translated,annotatedor
duplicated,inanyformorbyanymeanswithoutthepriorwrittenpermissionofKYLAND
Corporation.
Publisher:KYLANDTechnologyCO.,LTD. 
Address:ChongxinCreativeBuilding,ShixingEastRoad18#,
ShijingshanDistrict,Beijing,China
Website:http://www.kyland.cn
Postcode:100041
Tel:(+8610)88796676
FAX:(+8610)88796678
E‐mail:[email protected]  
Version:V1,Jan.2007
V2,Jun.2009
No.:27030013‐20
SICOM3004/SICOM3006User’sManual201105
3
Preface
SICOM3004/SICOM3006embeddedindustrialEthernetswitchisspeciallydesignedaccordingtothe
specificationsofcustomer.BasedonSICOMseriesproducts,theimprovedSICOM3004/SICOM3006is
abletobemountedonuser’scircuitmotherboard.
The user’s manual for SICOM3004/SICOM3006 Industrial Ethernet Switch mainly introduces the
technical principles, performanceindexes,installationandcommissioning, etc. It is a reference for
usersinsystemstartup, expansion androutinemaintenance.It isalsoapracticalteachingmaterial
forusertrainingandtechnicianstudy.
Thismanualmainlyincludesthefollowingcontents:
Chapter1OverviewandsystemfeaturesofSICOM3004/SICOM3006;
Chapter2PerformanceandservicefunctionsofSIOCM3004/SICOM3006;
Chapter3HardwarestructureofSICOM3004/SICOM3006;
Chapter4InstallationofSICOM3004/SICOM3006;
Chapter5FieldtestmethodsforSICOM3004/SICOM3006;
Chapter6NetworktopologyandsystemconfigurationofSICOM3004/SICOM3006;
AppendixAIntroducestwistedpairandpindistributionrulesofSICOM3004/SICOM3006;
AppendixBIntroducescabletypesandspecificationsofSICOM3004/SICOM3006;
AppendixCIntroducesabbreviationsusedinthismanual. 
Statement:Asproductandtechnologyupgradesandimprovesconstantly,thecontentsofthis
documentmaynotcompletelyaccordwiththeactualproduct.Forproductupgrading
information,pleasevisitourcompany’swebsiteordirectlycontactwithourbusiness
representative.

SICOM3004/SICOM3006User’sManual201105
4
Notice for Safety Operation
Thisproductperformsreliablyaslongasitisusedaccordingtotheguidance.Artificialdamageor
destructionoftheequipmentshouldbeavoided.  
z Readthismanualcarefullyandkeepitforfuturereference;  
z Donotplacetheequipmentsnearwatersourcesorhumidplaces;
z Donotplaceanythingonpowercableandputthecableinunreachableplaces;
z Donottieorwrapthecabletopreventfire.
z Power connectors and other equipment connectors should be firmlyinterconnectedand
frequentlychecked.
Inthefollowingcases,pleaseimmediatelycutoffthepowersupplyandcontactourcompany:
1. Watergetsintotheequipments;
2. Equipmentdamageorshellbreakage;
3. Abnormaloperationconditionsofequipmentorthedemonstratedperformanceshavechanged;
4. Theequipmentemitsodor,smokeormakesnoise.
z Please keep optical fiber plugs and sockets clean. During the operation of equipments, do not
lookdirectlyatthecrosssectionofopticalfiber;  
z Pleasekeeptheequipmentclean;ifnecessary,wipetheequipmentwithsoftcottoncloth;
z Donotrepairtheequipmentbyyourself,unlessitisclearlyspecifiedinthemanual.
ExplanationofWarningMarks:
Thismanualusestwokindsofnoticeablewarningsignstoarouse special
attention of users during operation. The implications of these signs are as
follows:
SICOM3004/SICOM3006User’sManual201105
5

Warning:payspecialattentiontothenotesbehindthemark,improper
operation will lead to serious damageoftheswitchorinjuryof the
operatingpersonnel.
Caution, attention, danger: remind the operators places that need to
payattentionto.  
SICOM3004/SICOM3006User’sManual201105
6
Contents
Chapter1:SystemOverview...................................................................................................................................................7
1.1ProductOverview.......................................................................................................................................................7
1.2ProductFeatures.........................................................................................................................................................7
1.3Packinglistandunpackingcheck.........................................................................................................................8
Chapter2:PerformanceSpecifications.......................................................................................................................‐10‐
2.1SystemSpecifications........................................................................................................................................‐10‐
2.2ServiceInterface..................................................................................................................................................‐11‐
2.3ServiceFunctions................................................................................................................................................‐11‐
Chapter3:HardwareStructure......................................................................................................................................‐15‐
3.1SystemStructure.................................................................................................................................................‐15‐
3.2SystemExplanation............................................................................................................................................‐16‐
Chapter4HardwareInstallation...................................................................................................................................‐21‐
4.1Installationrequirement..................................................................................................................................‐21‐
Chapter5:TestMethods...................................................................................................................................................‐23‐
5.1Selfinspection......................................................................................................................................................‐23‐
5.2TPPortTest...........................................................................................................................................................‐23‐
5.3FiberPortTest......................................................................................................................................................‐23‐
Chapter6:NetworkingandConfigurations..............................................................................................................‐25‐
6.1Networking............................................................................................................................................................‐25‐
6.2Systemconfiguration.........................................................................................................................................‐26‐
AppendixA:Twisted‐pairandPinDistribution......................................................................................................‐27‐
AppendixB:CableTypeandSpecifications..............................................................................................................‐29‐
AppendixC:Glossary................................................................................................................................................................30
SICOM3004/SICOM3006User’sManual201105
7
Chapter 1: System Overview
1.1ProductOverview
SICOM3004/SICOM3006embeddedindustrialEthernetswitchisspeciallydesignedaccordingto
the specifications of customer. Based on SICOM series products,theimproved
SICOM3004/SICOM3006isabletobemountedonuser’scircuitmotherboard.
SICOM3004/SICOM3006 series industrial Ethernet switch has strong network management
functionwhichsupportCLI,Telnet,WEB,SNMPbasedandOPCbased network management
software.
SICOM3004/SICOM3006industrialEthernetswitchsupportpinmounting. 
SICOM3004connectswith user’smotherboardbypinstoget2standard10/100Base‐TXports
and 2 fiber or copper optional portswhichsupportselfhealing ring network. SICOM3006 is
mountedonuser’smotherboardbypinstoget2standard10/100BaseTXportsand4fiberor
copperoptionalportswhichsupportself‐healingringnetwork.
In fiber or copper optional ports of SICOM3004/SICOM3006, if customer chooses fiber ports,
they will be compulsory to 100M full duplex, supporting DT‐Ring and able to form fiber ring
with the recovery time of less than 50ms. If customer chooses copper ports, they have
self‐adaptivefunction,supportingDTRingandabletoformtwisted‐pairringwiththerecovery
timeoflessthan50ms.
1.2 ProductFeatures
1. HighperformanceindustrialEthernetswitch
Supportvariousmanagementmethodsforuser’seasymanagement,suchasWEB,CLI,TELNET,
SNMP,OPC
10/100Base‐TX, self‐adaptive Ethernet ports, be automatically configured to 10Base‐T or
100Base‐TXstate,fullorhalfduplexoperationmode,supportautoMDI/MDI‐Xconnection
100Base‐FXfullduplexmultimode/singlemoderedundantfiberports
Thefastringnetworkredundancytechnologywithrecoverytimeoflessthan50ms,raisingthe
reliabilityofsystemcommunication 
IEEE802.3i,IEEE802.3u,IEEE802.3x,IEEE802.1p,IEEE802.1Q,IEEE802.1sstoreand forward
SICOM3004/SICOM3006User’sManual201105
8
switchingmode 
SupportIGMPSnooping,portmirroring,porttrunking,broadcaststormcontrol
SupportDT‐Ring,DT‐Ring+,RSTPforredundancyprotection
SupportVLAN
ACLfunction 
Alarmfunction
SupportSNMPprotocol
Support802.1P,IPTOS,DSCPprioritysetting
TransparenttransmissionofVLANTagpackets
FTP‐basedonlinesoftwareupdate,easyforuser’sdevicemanagementandrenewal
2. IndustrialPowerDesign
3.3V/3A power is supplied to SICOM3004/SICOM3006 by motherboardthroughpins.To
guaranteestableandreliablepowerinput,theeffectivevalueofinputpowerrippleislessthan
50mvandstartingcurrentismorethan3A.
1.3 Packinglistandunpackingcheck
1. Packinglist
Thepackinglistincludesthefollowingitems:
SICOM3004/SICOM3006industrialEthernetswitch                 1 
User’sManualforSICOM3004/SICOM3006IndustrialEthernetSwitch1
CustomerServiceGuideline1
Networkcable1
2. Unpackingcheck
Beforeopeningthecase,placeitstably,payattentiontothedirectionofthepackingcaseand
ensureitsrightsideisfacingupward,soastopreventSICOM3004/SICOM3006fallingfromthe
caseafteropeningit.Ifusingahardobjecttoopenthecase,donotoverextendthehardobject
intothecasetoavoiddamageoftheequipmentsinsideit. 
Afterunpacking,pleasechecktheaccessoriesandtheappearanceoftheequipment.Ifanything
SICOM3004/SICOM3006User’sManual201105
9
ismissingordamaged,pleasecontactus
  Warning: 
Forthebuiltinprecisepartsof the equipment, please handle with care and avoid strenuous
vibrationtoavoidaffectingtheperformancesofequipments.
SICOM3004User’sManual201103
Chapter 2: Performance Specifications
2.1SystemSpecifications
ThesystemperformancespecificationsofSICOM3004/SICOM3006industrialEthernetswitchare
showninTable2‐1. 
Table2‐1SystemSpecifications
Specifications SICOM3004/SICOM3006
QuantityofRJ45port 2×10/100Base‐TX
Quantity of redundant
100Mfiberorcopperports
2×100Base‐FX‐SM/MMor2×10/100Base‐TX(SICOM3004)
4×100Base‐FX‐SM/MMor4×10/100Base‐TX(SICOM3006)
Systemperformance
Standards: IEEE802.3i, IEEE802.3u, IEEE802.3x, IEEE 802.1p,
IEEE802.1Q,IEEE802.1s
Maxstore‐and‐Forwardspeed:148810pps; 
Max.filteringspeed:1488100pps
Switchingmode:Store‐and‐Forward
Systemswitchingbandwidth:5.6G
Electromagneticcompatibilityinterference:EN55022
Electromagneticcompatibilityimmunity:EN50082‐2
TPportparameters
Physicalport:2.54mm‐spacingtwo‐rowpin
RJ45port:10/100Base‐TX,supportingauto‐negotiation
Portstandard:inlinewithIEEE802.3standard
Transmissiondistance:<100m
Fiberportparameters
Physicalport:2.54mm‐spacingtwo‐rowpin
Opticalpower:>‐13dbm(SM)  >‐20dbm(MM)
Receivingsensitivity:<‐28dbm(SM) <‐35dbm(MM)
Wavelength:1310nm(SM)  1550nm(SM)  1310nm(MM)
Transmissiondistance:20‐80km(SM)  <5km(MM) 
Connectortype:SC/FC/ST
Transmissionspeed:125Mbps(100M)
Powersupply Inputvoltage: DC3.3V
Inputpowerconsumption:<10W
Mechanicalparameters Physical dimensions (height×width): 80mm×80mm
(SICOM3004);95mm×80mm(SICOM3006) 
SICOM3004/SICOM3006User’sManual201105
- 11 -
Mountingmode: pinmounting
Weight:0.1kg
Ambientconditions
Operatingtemperature:‐40℃~85
Storagetemperature:‐4085
Humidity:595%(non‐condensing
2.2 ServiceInterface
1. 2 10/100Base‐TX RJ45 ports. Each RJ45 port has self‐adaptive function, capable of
automaticallyconfiguringbetween10Base‐Tand100Base‐TX,betweenfullduplexandhalf
duplexmode,supportingMDI/MDI‐Xauto‐connection.Thetransmissiondistanceislessthan
100m.
2. 2(SICOM3004)or4(SICOM3006)fiberorcooperoptionalportssupportingself‐healingring
network.2or4redundant100Base‐FXSM/MMfiberportsandthemaximumthroughputof
each port is 100Mbps with compulsory 100M full duplex working mode. 2 or 4 standard
10/100Base‐TX Ethernet ports. Each port has self‐adaptive function, capable of
automaticallyconfiguringbetween10Base‐Tand100Base‐TX,betweenfullduplexandhalf
duplexmode,supportingMDI/MDI‐Xauto‐connection.Supportringredundancytechnology
withrecoverytimeoflessthan50ms.
3. Comply with IEEE802.3i, IEEE802.3u, IEEE802.3x, IEEE 802.1p, IEEE 802.1Q, IEEE802.1s,
etc.
4. LEDindicatorsarealsoprovidedtomotherboardbypins,includingsystemoperationLED
(CPURUN1),masterorslaveLED(RUN2),2alarmLEDs,4(SICOM3004)or6(SICOM3006)
LINKLEDsandSPEEDLEDsforports. 
2.3 ServiceFunctions
TheservicefunctionsofSICOM3004/SICOM3006mainlyinclude:
LEDIndicator
LEDindicatorsareprovidedtomotherboardbypins.TheLEDsindicatetheportstatusincluding
transmittingspeed,linkstatusandsystemstatus. 
Layer2Switching
Thetwocommonlyusedswitchingtechnologies:CutThroughandStore‐and‐Forward. In
SICOM3004/SICOM3006User’sManual201105
- 12 -
CutThrough,assoonastheswitchreceiveaframeheader,itisimmediatelyforwardedwithout
any error checking and processing; in Store‐and‐Forward, after receiving and storing the
completeframe,errorcheckingisconductedbeforeforwarding.Store‐and‐forwardismostwidely
usedswitchingtechnologyanditisalsoadoptedbySICOM3004/SICOM3006.
VLAN
VLANwilldivideanetworkintomultiplelogicalnetworks.Datapacketscannotbetransmitted
betweendifferentVLANssoastocontrolthebroadcastdomainandsegmentflow andimprove
the network performance, security and manageability. SICOM3004/SICOM3006 series supports
IEEE802.1qVLANtag.Itcanbedividedintoupto4094VLANsbasedonports.TheVLANdivision
canberealizedviaWEB,CLI.VLANTagpacketistransmittedtransparently. 
QoSfunction
IEEE 802.1p is the most widely used priority solution in LAN environment.
SICOM3004/SICOM3006series supports 802.1p standard, as well asIPTOSandDSCPpriority
configurations. When the terminal connected to SICOM3004/SICOM3006 doesn’t support these
three priorities and user wants to set different priorities to services in different ports, QoS
functioncanbeused todoport‐basedpriorityconfiguration.Thisconfigurationonlyaffectsthe
datapacketswithoutprioritiesintheports.EachportofSICOM3004/SICOM3006support4‐level
priorityconfiguration(highest,high,low,lowest).
PortTrunking
SICOM3004/SICOM3006 series industrial Ethernet switch can aggregateseveralphysicalports
intoalogicalport,thentheseportshavesamerate,duplexmodeandVLANID.PortTrunkingcan
beconfiguredinasingleswitchwithmax4PortTrunkinggroups.Thisfunctioncanreducethe
networktrafficcongestionandenhancefault‐toleranceperformance.
Portmirroring(Portsniffing)
Becapableofmirroringthedatapacketsinaporttoanotherportforrealtimemonitoring the
communicationdata. 
ConfigurePortWorkingModes
SICOM3004/SICOM3006 series is able to configure the working mode of all ports through
network management: self adaptive, 10M/half‐duplex, 100M/half‐duplex, 10M/full‐duplex,
100M/full‐duplex,etc
ConfigurePortTrafficFlow
SICOM3004/SICOM3006User’sManual201105
- 13 -
SICOM3004/SICOM3006seriescanconfiguretheTXandRXrateofallportsviathemanagement
software.Forportof100Mbps,itcanbesetas128K,256K,512K,1M,2M,10M,50M,100M. 
StaticMulticastCommunication
Addingmulticastusersbythewayofmanuallyaddingstaticmulticasttable,comparedtodynamic
multicast,ismoresimple,reliableandfasterwithouttheneedofprotocols.Themulticastdatacan
beforwardedbyconfiguringstaticmulticastforwardingtables.Userscanmanuallyconfigurethe
multicastcommunicationaccordingtotheirownrequirements.Staticmulticastcommunication
cannotbeusedwithIGMPsimultaneously.
IGMP
IGMP is Internet Group Multicast Protocol. SICOM3004/SICOM3006 series offers IGMP
monitoringandqueryfunctions.Datapacketscanbetransmitted to multi necessary host
computersandpreventoverloading.Itsolvestheproblemsofbandwidth occupation when
broadcasting.
BroadcastStormControl
Whentoomuchbroadcastpacketsaretransmittedinthenetwork,theywilltakeupsomuch
bandwidththatcauseanetworktimeout.Itiscallednetworkstorm. SICOM3004/SICOM3006
supportbroadcastdatapackets,multicastdatapacketsandbroadcaststormcontrolanddiscard
thebroadcastdatapacketsthatexceeduser’stimelimitsetting. 
DTRing
DT‐RingisKyland’sproprietarycommunicationprotocol.Itdeterminesthestateofring&portby
inspectingtheringportstate,soastoensuretheredundantnetworkwontformaringand
achieve afast andreliableEthernetredundantringtomeetthehighrequirements ofindustrial
communications.
DTRing+
DTRing+,basedonDTRing,isalsoKylandsproprietarycommunication protocol which is to
makeabackupbetweentworingsanddeterminering&portstatebytheIDofbackupdeviceso
astoensuretheredundantnetworkwon’tformaring.Thisfunctionguaranteesafastandreliable
redundantringtomeethighrequirementsinthefieldofindustrialcommunication.
RSTP
SICOM3004/SICOM3006hasRSTPandSTPfunctionswhichoffernetworkredundancyprotection
fortheswitchsnetwork.RSTPcanachieveallfunctionsofSTPwithanextrafunctionofreducing
SICOM3004/SICOM3006User’sManual201105
- 14 -
the delay time from blocking to forwarding in the port in ordertoresumethenetwork
communicationASAP.
ACL
ACL (Access Control List) use protocols to define the access rulesbythesourceortargetMAC
addresses. It can limit the network traffic, enhance network performance and control the
communicationflow.ACListhebasicsecuritymethodtonetworkaccess.
AlarmOutput
Thisfunctionissignificantfortherealtimetransmissionofdevicealarms.Alarmfunction
includesportalarmandringalarmwhichcanbeenabledbymanagementsoftware.Thealarm
informationisdisplayedonthenetworkmanagementinterface.
SNMP
SNMPSimple Network Management Protocoloffersaframestructureforlowlevel
networkmanagement.SNMPprotocolisusedwidely.Manykindsofnetworkingdevices,software
andsystemadoptitbecauseitiseasytoberealized,free,andcanbeusedtocontrolvarious
devices.
RMON
RMONisastandardmonitoringregulation,usedtoswitchthenetworkmonitoringdatabetween
networkmonitorsandconsolesystem.Itoffersmoreselectionsfornetworkoperatorstochoose
thesuitableconsoleandnetworkmonitorforspecialrequirements. It is a supplementation to
SNMPfunctionandisespeciallyusefulformonitoringandmanagingLAN.Thepurposeof
developing RMON is to provide statistic result of information flow and analyze network
parameterssoastoworkoutacomprehensivenetworkdiagnoses,planandregulation. 
By RMON, users can do operation among SNMP management stations and monitoring agents.
Furthermore,itcanofferastandardforagroupofMIBtocollectthenetworkstatisticswhichis
notavailableviaSNMP.RMONrealizesearlynetworkdiagnosesbyusingpowerfulAlarmGroup,
whichallowstosetthresholdsforkeynetworkparameterssoastoautomaticallysendalarm
signaltocentralmanagementconsole.

SICOM3004/SICOM3006User’sManual201105
- 15 -
Chapter 3: Hardware Structure
3.1SystemStructure
ThehardwarestructureofSICOM3004isasFigure3‐1:
Figure3‐1HardwareStructureofSICOM3004
FE1‐FE2:210/100Base‐TXports
FX3‐FX4/FE3‐FE4:2100Base‐FXportsor210/100Base‐TXports(optional)
ThehardwarestructureofSICOM3006isasFigure3‐2:
SICOM3004/SICOM3006User’sManual201105
- 16 -
Figure3‐2HardwareStructureofSICOM3006
FE1‐FE2:210/100Base‐TXports
FE3‐FE6/FX3‐FX6:410/100Base‐TXportsor4100Base‐FXports(optional)
3.2 SystemExplanation
. Power
3.3V/3A power is supplied to SICOM3004/SICOM3006 by motherboardthroughpins.To
guarantee stable and reliable powerinput,theeffectivevalueof input power ripple is less
than50mvandstartingcurrentismorethan3A.
. LED
LEDsincludesystemoperationLED(CPURUN1),masterandsalveLED(RUN2),2alarmLEDs,
4(SICOM3004)or6(SICOM3006)LINKLEDsandSPEEDLEDsforports
. Networkmanagement
The network management CONSOLE port is a RS232 serial port. Switch provides TTL
interface level to motherboard by pins. RS232 interface circuit is implemented on
motherboard.
. AlarmOutput
OEMboardhasringnetworkfaultselfinspectionandalarmfunctions. When network
breakdown, poor contact, communication problem and other failureshappeninthering
network,OEMboardisabletoautomaticallylocatethefaultandsendalarmbysoftwareand
hardwarecontacts.Inhardware,itisjudgedbythesignalprovidingbypins.Whentheuplink
portisundernormalconnection,thecorrespondingalarmsignal “ALARM1” or “ALARM2”
outputshighlevel;whentheconnectionisabnormal,thecorresponding alarm signal
ALARM1”or“ALARM2”outputslowlevel.
. Pindefinition
SICOM3004 adopts one 2 ×16, 2.54mm‐spacing two‐row pin (J5) and one 2 ×6,
2.54mm‐spacingtwo‐rowpin(J6).SICOM3006adoptsone2×16,2.54mm‐spacingtwo‐row
pin(J5)andtwo2×6,2.54mm‐spacingtwo‐rowpin(J6,J7).
SICOM3004/SICOM3006User’sManual201105
- 17 -
J5pindiagramandpinexplanationforSICOM3004:
PINnumber1234
Signaldefinition GND GND +3.3V +3.3V
PINnumber 5 6 7 8
Signaldefinition +3.3V +3.3V  RUN2operation
LED(masteror
slaveLED)
PINnumber 9 10 11 12
Signaldefinition RXD(LVTTLlevel,
3.3V)
TXD(LVTTLlevel,
3.3V)
CPU RUN1
operationLED
Port1LINKLED
PINnumber 13 14 15 16
Signaldefinition Port1SPEEDLED Port2LINKLED Port2SPEEDLED Port3LINKLED
PINnumber 17 18 19 20
Signaldefinition Port3SPEEDLED
(fiber port
doesn’t has this
LED)
Port4LINKLED Port4SPEEDLED
(fiber port
doesn’t has this
LED)
Reset: system
reset signal (it
takeseffectatlow
level)
PINnumber 21 22 23 24
Signaldefinition V1 (Ring 1 alarm
outputsignal)
V2(Ring2alarm
outputsignal)
TXD1+Port1TXD1Port1
PINnumber 25 26 27 28
Signaldefinition RXD1+(Port1) RXD1‐(Port1) TXD2+(Port2) TXD2‐(Port2)
SICOM3004/SICOM3006User’sManual201105
- 18 -
PINnumber 29 30 31 32
Signaldefinition RXD2+(Port2) RXD2‐(Port2) GND GND
Note:V1andV2areforring1andring2.Whentheswitchissettobemasterinaring,ifthering
isundernormalconnection,thepin21andpin22outputhighlevel;iftheringisdisconnected,
theyoutputlowlevel;whentheswitchissettobeslaveinthering,thepin21andpin22output
highlevel. 
J6pindiagramandpinexplanationforSICOM3004
(Thispinisforport3andport4)
PINnumber 1 2 3 4
Signaldefinition GND TXD3+(port3) TXD3‐(port3) RXD3+(port3)
PINnumber 5 6 7 8
Signaldefinition RXD3‐
(port3)
TXD4+(port4) TXD4‐(port4) RXD4+(port4)
PINnumber 9 10 11 12
Signaldefinition RXD4‐
(port4)
FX0_SD 
(SD signal of
fiberport1)
FX1_SD 
(SD signal of
fiberport2)
GND
Note:Thepinswhichdon’thaveexplanationintheabovetableareunused.Powerandresetsignal
areinputsignaltoSICOM3004andtherestareoutputsignalfromSICOM3004.
J5pindiagramandpinexplanationforSICOM3006:
PINnumber1234
Signaldefinition GND Port5LINKLED Port5SPEEDLED +3.3V
PINnumber 5 6 7 8
Signaldefinition +3.3V +3.3V Port6LINKLED
RUN2operation
LED(masteror
slaveLED)
PINnumber 9 10 11 12
Signaldefinition RXD(LVTTLlevel,
3.3V)
TXD(LVTTLlevel,
3.3V)
CPU RUN1
operationLED
Port1LINKLED
PINnumber 13 14 15 16
Signaldefinition Port1SPEEDLED Port2LINKLED Port2SPEEDLED Port3LINKLED
SICOM3004/SICOM3006User’sManual201105
- 19 -
PINnumber 17 18 19 20
Signaldefinition Port3SPEEDLED
(fiber port
doesn’t has this
LED)
Port4LINKLED Port4SPEEDLED
(fiber port
doesn’t has this
LED)
Reset: system
reset signal (it
takeseffectatlow
level)
PINnumber 21 22 23 24
Signaldefinition V1 (Ring 1 alarm
outputsignal)
V2(Ring2alarm
outputsignal)
TXD1+Port1TXD1Port1
PINnumber 25 26 37 28
Signaldefinition RXD1+(Port1) RXD1‐(Port1) TXD2+(Port2) TXD2‐(Port2)
PINnumber 29 30 31 32
Signaldefinition RXD2+(Port2) RXD2‐(Port2) Port6SPEEDLED GND
Note:V1andV2areforring1andring2.Whentheswitchissettobemasterinaring,ifthering
isundernormalconnection,thepin21andpin22outputhighlevel;iftheringisdisconnected,
theyoutputlowlevel;whentheswitchissettobeslaveinthering,thepin21andpin22output
highlevel. 
J6+J7pindiagramandpinexplanationforSICOM3006
(Thesetwopinsareforport3,port4,port5andport6)
PINnumber 1 2 3 4
Signaldefinition GND TXD3+(port3) TXD3‐(port3) RXD3+(port3)
PINnumber 5 6 7 8
Signaldefinition RXD3‐
(port3)
TXD4+(port4) TXD4‐(port4) RXD4+(port4)
PINnumber 9 10 11 12
Signaldefinition RXD4‐
(port4)
FX0_SD 
(SD signal of
fiberport1)
FX1_SD 
(SD signal of
fiberport2)
GND
PIN
number
13 14 15 16
Signaldefinition GND TXD5+(port5) TXD5‐(port5) RXD5+(port5)
PIN
number
17 18 19 20
Signaldefinition RXD5‐
(port5)
TXD6+(port6) TXD6‐(port6) RXD6+(port6)
PINnumber 21 22 23 24
Signaldefinition RXD6‐
(port6)
FX3_SD 
(SD signal of
fiberport3)
FX4_SD 
(SD signal of
fiberport4)
Note:Thepinswhichdon’thaveexplanationintheabovetableareunused.Powerandresetsignal
SICOM3004/SICOM3006User’sManual201105
- 20 -
areinputsignaltoSICOM3006andtherestareoutputsignalfromSICOM3006.
WeprovidesocketsforeachJ5,J6andJ7pinonOEMboardasbelow. 
Socketforpins(topview)
Socketforpins(frontview)
SICOM3004:
SocketforJ5:2×16p,2.54mm‐spacingtwo‐rowsocketwiththeheightof12mm
SocketforJ6:2×6p,2.54mm‐spacingtwo‐rowsocketwiththeheightof12mm
SICOM3006:
SocketforJ5:2×16p,2.54mm‐spacingtwo‐rowsocketwiththeheightof12mm
SocketforJ6+J7:2×12p,2.54mm‐spacingtwo‐rowsocketwiththeheightof12mm
Thebasepinsonthesocketshouldbesolderedtothemotherboard.Thegiltthicknessismore
than10U.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

KYLAND Technology SICOM3006 User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI