TANK BOOSTER
Installation Instructions/ Directives d’Installation/ Instrucciones de Instalación
IS279 REV K
11-12-12
3. Installation Guidelines
Failure to comply with all aspects of these instructions may result in unsafe
performance.
All installations must comply with relevant State, Provincial and Local Authority
requirements.
Delivery Temperature:
Every valve is factory set for 120 F outlet temperature, with a 140 F hot water
inlet temperature.*
*NOTE: To ensure delivery of the desired mixed water temperature at the outlet the installer
must adjust and verify the temperature at the outlet by carefully following instructions on the
following page.
To Achieve Maximum Hot Water Delivery Performance
To achieve maximum hot water delivery performance, the TANK BOOSTER
must first be installed on the water heater in accordance with these instructions.
Once installed consult the water heater manufacturer’s instructions and increase
the temperature control device to around 140°F. This has the added benefit of
being a temperature determined by the OHSA as being sufficient to kill
Legionella bacteria. Verify the outlet temperature of the TANK BOOSTER and
adjust in accordance with these instructions.
Non Return Valves:
Non return valves are integrated in the cold and hot water inlets of the valve. For
correct and safe system function, ensure that the check valve is clean of debris
and functioning correctly.