Fitting instructions
ASKOHEAT‐
F
FlangeheaterØ180mm
ASKOHEAT‐F_180_2-9_en MVGASV_120101_en_V3 www.askoma.com Page3
Operangdata,applicaon,dimensionsandmodeloftheflangeheaterareontheidenficaonplate
andcircuitdiagramonthedevice,orcanbefoundinthefinginstrucons/usermanuals.
For safety reasons, the device may not be installed from above or
below.
The device must be installed horizontally and ensure that the
"TOP" label point is upwards.
Make sure that the heang tubes are enrely covered with liquid before placing into operaon.
Thecirculaonoftheliquidshallnotbeinhibited.
Important information
Ifaheatexchangerisfiedinthesametank,thecontrollermustlimitthetemperaturecausedbythe
heatexchangerto85°C.Thispreventsthesafetytemperaturelimiteroftheflangeheatertripping.
Safety temperature limiter
Thesafetytemperaturelimitermaytripattemperatureslowerthanapprox.–15°C(e.g.transporta-
onorstorage).Ifthishappens,presstheresetbuon.Seetheseconintendedforexpertsintheuser
manual.
The device may only be used to heat water.
Corrosion protection
Pleasenote:
Thisheangelementisapplicableinstainlesssteelboileraswellasinblacksteel/blacksteelenam-
elledboilers.SelectthesengsviaDIPswitchaccordingtotheboilertype.
Foraninstallaonoftheheangelementintoblacksteelorblacksteelenamelledboilers,theredslide
switch(DIPswitch)hastobeleinposion“2”(factoryseng).
When installing the heang element into a stainless steel or chromesteelboiler,theslideswitch
(DIPswitch)hastobeswitchedtoposion“ON”.
Incaseofdisregardcorrosiondamagesondeviceandboilercouldbecaused.