Intermatic DD150HPS Installation guide

Type
Installation guide
FOR OUTDOOR USE ONLY
NOT FOR USE IN HAZARDOUS ATMOSPHERES
IMPORTANT: Read instruction sheet carefully before installing fixture.
Retain instructions for future reference.
ELECTRICAL REQUIREMENTS
A qualified electrician should complete all required wiring. This fixture will accept 120 volt AC and must be properly
grounded for safety. A mounting suitable for outdoor use and rated for wet locations is required. Follow all applicable
electrical codes and regulations.
WARNING:
Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING:
Fire hazard
USE MIN 75ºC SUPPLY CONDUCTORS.
CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.
Lamp and housing become very hot during use.
Ensure free air circulation around unit to dissipate heat.
Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.
Avoid locations where humans or animals might accidentally touch fixture.
WARNING:
Explosion hazard
Never operate light without securing the lens door. When light is operating, the gas in the
lamp inner arc tube is at high pressure.
Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.
WARNING:
Explosion hazard
Wear safety glasses and gloves when handling lamp, High Pressure Sodium outer envelope is under
vacuum and could implode.
MOUNTING & WIRING
1. Attach the two-piece mounting bracket to the
extension arm by interlocking the halves and
securing with the bolt and hex nut provided.
Leave approximately one inch of the
extension arm protruding from the bottom of
the bracket. (See Figure 1)
2. Place the mounting bracket and arm
assembly on the desired mounting surface.
Mark the four hole locations required for
mounting. Put the assembly aside and
prepare the marked locations for attaching
the mounting bracket and arm assembly
.
3. Mount the extension arm assembly using the
hex head lag bolts provided or other suitable
method. Secure the mounting bracket solidly
to the mounting surface.
HID Dusk-To-Dawn - DD Series
INSTALLATION INSTRUCTIONS
Lamp Types: High Pressure Sodium 150 Watt
Models: DD150HPS
Figure 1
Photocontrol
Receptacle/socket
Photocontrol
Fixture
Mounting Bracket
Clamp
Extension arm
Lag Bolts (4)
Connection Plug
(Not Provided)
Conduit Connector
(Not Provided)
Conduit
(Not Provided)
Mounting screws
for reflector
Lens
Reflector
Bulb Socket
4. Feed supply wires through the arm and connect them to the fixture using approved twist on wire connectors.
(See Figure 2)
a. Connect the Black fixture wire to the Black (hot) supply wire.
b. Connect the White fixture wire to the White (neutral) supply wire.
c
. Connect the supply grounding wire to the green screw located on the one-piece fixture mounting arm
c
lamping bracket.
5. Secure the fixture to the arm using the one-piece clamping bracket and bolts provided.
6. Fasten the reflector and lens assembly to the fixture using the two screws and washers provided.
7. Screw lamp into socket in lamp holder until finger tight.
8. Insert the photocontrol into the socket on top of the fixture by aligning the prongs and twist clockwise to lock.
9. The arrow on top of control should be pointed away from the mounting surface.
a. If it is not, remove the photocontrol and reposition the socket on the top of the fixture by loosening the
screw in the center of the socket. Do not remove the screw.
b. Rotate socket to new position and retighten screw. Do not rotate over 360 degrees.
10. Turn on the electric power to the fixture.
When power if first applied, some controls will turn the light on and turn off in two or three minutes. The
fixture will take approximately 5-7 minutes to achieve full illumination.
11. To check operation during daylight, cover the photocontrol with black electrical tape. Allow 3-5 minutes for the
fixture to turn off or on when testing. Be sure to remove the tape when testing is completed.
LAMP
REPLACEMENT
CAUTION:
Use lamp of correct type and wattage as specified on fixture.
1. T
urn of
f power at circuit breaker or fuse box.
Allow fixture and lamp to cool.
2. Remove old lamp and replace with new lamp of correct type and wattage. Screw lamp into socket in lamp holder
until finger-tight.
3.
T
urn power back on. If desired, test operation as described in steps 10 and 1
1 above.
4. Properly dispose of lamp per manufacturer’s recommendations.
LIMITED 1 YEAR WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of
charge. This warranty is extended to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in
handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with
instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs; (f) the finish on any portion of the product, such as surface and/or weathering, as this is
considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
OR IMPLIED W
ARRANTIES.
ALL
IMPLIED W
ARRANTIES, INCLUDING
THE W
ARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD
STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage
prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-
7000 http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
THESE INSTRUCTIONS DO NOT COVER ALL VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL SITUATIONS RELATED
T
O FIXTURE INST
ALLATION, OPERATION OR MAINTENANCE. FOR FURTHER INFORMATION CONTACT YOUR DISTRIBUTOR OR
INTERMATIC INCORPORATED - SPRING GROVE, ILLINOIS 60081 (815) 675-7000 www.intermatic.com
158HL12120
Figure 2
I
GN-01
PHOTO
C
ONTROL
1
20 V
COM
(
BLACK)
WHITE
R
ED
C
OM
L
AMP
X
2
X3
X1