Type Motion alarm
Alarm Built – in 110 db alarm or pleasant announcement chime
Battery 1 x 9 Volt battery (alkaline battery recommended)
Fig. 2
Fig. 3
Fig. 4
Fig. 5
(Figure 2) (Figure 3) (Figure 4) (Figure 5)
CAUTION: This alarm is extremely loud. For your safety, never place the unit close to
your ears. To test the alarm, direct the unit away from you at arms length and
activate.
OPERATING INSTRUCTIONS
MOTION ALARM
MODEL 2008
®
ENG
NL
FR
DU
ESP
Type Motion alarm
Alarm Built – in 110 db alarm or pleasant announcement chime
Battery 1 x 9 Volt battery (alkaline battery recommended)
CAUTION: This alarm is extremely loud. For your safety, never
place the unit close to your ears. To test the alarm, direct the unit
away from you at arms length and activate.
9 Meter
9 Meter
2008_fig.pdf 08-11-2006 11:54:27
2008_fig_2.pdf 08-11-2006 13:05:14
9 Meter
9 Meter
2008_fig.pdf 08-11-2006 11:54:27
Figure 2 Figure 3 Figure 4 Figure 5
DESQ International:
Gildeweg 18 - 3771 NB – Barneveld
The Netherlands
Phone +31 (0)342-425350 - Fax +31 (0)342-425351
E-mail [email protected] - Internet www.desq.eu
Service Department:
NL: Phone +31 (0)342-425352.
SPAIN: Ofiactiva S.L. - Phone +34 935441884
ENG
INTRODUCTION
The DESQ motion alarm 2008 provides detection of unwanted intruders in your (home) office. The latest infrared tech-
nology is used to detect any movement within the protected area. It can provide valuable protection if used properly.
However, this unit cannot guarantee complete protection against burglary or robbery. Therefore, DESQ Interna-
tional will not be held responsible for any loss or damage which could occur. In order to use this product correctly,
read these instructions carefully. Please keep instructions for future reference.
IMPORTANT SAFETY TIPS
1) Read all installation and operating instructions
2) Avoid dropping or rough handling
3) Be careful not to damage the plastic lens
4) Do not install alarm where it will be exposed to direct sunlight or rain
5) The alarm siren is very loud, never put the unit close to your ear. To test the alarm, direct the unit away from
you at arms length and activate.
6) This unit should be directed away from heat sources, such as radiators, heating ducts and stoves
7) Be aware, pets can trigger the motion alarm, as well as movement detected through a window
8) If the unit goes off at random, it is possible the unit is located too close to a heat source. Changing the location
or direction of the unit can remedy this
9) People and/or automobiles may be detected if they are close to a window and within range of the unit.
SELECTING THE MOUNTING LOCATION
Important: before mounting and testing this unit, be sure to read the “important safety tips” section at the
beginning of this manual. For best coverage, the unit should be placed in a corner located between 1 & 2
meters above the floor. The area of coverage by the unit is 20 degrees vertically (see figure 4) and 110 degrees
horizontally (see figure 5) with a range of approximately 9 meters from the unit. Before installing the mounting
screws, you may want to test the location you have selected.
TESTING
After selecting a location for installation of the unit, the DESQ 2008 motion alarm will allow you to perform a
“walk test” to determine the area which is being protected by the unit.
1) Test the area of detection (figure 4 and 5). Slide the function switch to the alarm position. The unit is now in
the “walk test” mode.
2) Begin walking in front of the unit, the LED indicator will now blink on and off as you walk within the detection
area. If you walk beyond the detection range, the LED will go out and remain off. If you walk back into the
detection area the LED indicator will illuminate.
3) After testing the detection area, leave the room. Wait for at least 2 minutes and go back into the room. If the
LED indicator does not go on, you have been detected as an intruder. The alarm siren will sound approximately
60 seconds. If the LED indicator goes on again, you have not waited long enough and the unit is still in the “walk
test” mode.
4) Slide the switch to OFF position, the unit is now disarmed and testing is completed.
5) Using the template provided (figure 6), mark location of holes and install anchors and screws (do not screw
all the way in). Place the unit over the screws and slide the unit down to secure in place.
OPERATION
The DESQ 2008 motion alarm provides 2 different modes of operation: alarm (110 db) and chime. A slide switch
is located on the side of the unit to select which mode is active.
ALARM MODE
1) To arm the unit, slide the switch to the “alarm” position. The unit will automatically arm itself after no motion
has been detected for approximately 2 minutes.
2) To disarm the unit, slide the switch to OFF position, you have approximately 5-10 seconds to slide the switch
to OFF position before the alarm sounds once you have entered the detection area.
CHIME MODE
1) To change the unit to the chime mode, simply slide the switch to “chime” position.
2) The chime mode sounds a pleasant “ding-dong” sound when any motion is detected within the detected zone.
The chime will sound for 3 times, then shut-off and automatically resets itself.
LOW BATTERY INDICATOR
The LED indicator light located on the front of the unit will light up when the battery becomes low. It will stay on
until the battery is replaced (9 Volt).
2008
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Desq 2008 - Motion Alarm Operating instructions

Category
Motion detectors
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI