ATIKA ALE 600 Owner's manual

Category
Dehumidifiers
Type
Owner's manual

This manual is also suitable for

Luftentfeuchter
Originalbetriebsanleitung – Sicherheitshinweise – Ersatzteile
Seite 1
Air dehumidifier
Original instructions – Safety instructions – Spare parts
Page 11
Déshumidificateur d‘air
Notice originale – Consignes de sécurité – Pièces de rechange
Page 21
Odvlhčovač vzduchu
Originální návod k použití – Bezpečnostní pokyny – Náhradní díly
Str 31
Luftaffugter
Original brugsanvisning – Sikkerhedshenvisninger – Reservdeler
Side 41
Deumidificatore
Istruzioni originali – Indicazioni per la sicurezza – Pezzi di ricambio
Pagina 51
Luchtontvochtiger
Oorspronkelijke gebruiksaanwijzing
Veiligheidsinstructies - Reserveonderdelen
Blz. 61
Odvlhčovač vzduchu
Originálný návod na použitie – Bezpečnostné pokyny
Náhradné dielce
Strana 71
ALE 600
ALE 800
11
You may not start to operate the machine until
you have read these operating instructions,
observed all the instructions given and
installed the machine as described!
Keep the operating instructions in a safe place for future
use.
Electrical devices do not go into the domestic rubbish.
Give devices, accessories and packaging to an
ecofriendly recycling.
According to the European Directive 2002/96/EC on electrical
and electronic scrap, electrical devices that are no longer
serviceable must be separately collected and brought to a
facility for an environmentally compatible recycling.
C
C
o
o
n
n
t
t
e
e
n
n
t
t
s
s
EC Declaration of Conformity 11
Extent of delivery 11
Symbols on the machine 11
Symbols in the operating instructions 12
Proper use 12
Residual risks 12
Security advices 12
Electrical safety advices 12
Function principle 13
Location of the air dehumidifier 13
Location 13
Electric supply 13
Power system fuse protection 13
Start-up 13
Before starting up 13
Control panel 14
Powering up 14
Shutting down 14
Setting the humidity 14
Automatic defroster 14
Operating hour counter 14
Water outlet 15
Removing the water collecting container 15
Continuous or extended operation 15
Transport 16
Cleaning and maintenance 16
Cleaning the air filter 16
Removing the filter 16
Inserting the filter 16
Cleaning the device 16
Maintenance 17
Storage 17
Possible faults 17
Fault code 18
Technical specifications 18
Wiring diagram 19
Refrigerant circuit 19
Spare parts 20
Guarantee 20
E
E
C
C
D
D
e
e
c
c
l
l
a
a
r
r
a
a
t
t
i
i
o
o
n
n
o
o
f
f
C
C
o
o
n
n
f
f
o
o
r
r
m
m
i
i
t
t
y
y
according to Directive 2006/95 EC
We,
ATIKA GmbH & Co. KG
Schinkelstraße 97
59227 Ahlen - Germany
herewith declare under our sole responsibility that the product
Air dehumidifier type HT 600 and HT 800
(model ALE 600 and ALE 800)
Serial number: see last page
is conform with the above mentioned EC directives as well as
with the provisions of the guidelines below:
2004/108/EC
Following harmonized standards have been applied:
EN 55014-1:2006; EN 55014-2:1997+A1:2001;
EN 61000-3-2:2006; EN 61000-3-3:2008;
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
A2:2006 + A13:2008
EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006
Keeping of technical documents at:
ATIKA GmbH & Co. KG – Technical department
Schinkelstr. 97 59227 Ahlen – Germany
Ahlen, 16.04.2010 A. Pollmeier, CEO
E
E
x
x
t
t
e
e
n
n
t
t
o
o
f
f
d
d
e
e
l
l
i
i
v
v
e
e
r
r
y
y
After unpacking, check the contents of the box for
! completeness
! possible transport damage.
Report any damage or missing items to your dealer, supplier
or the manufacturer immediately. Complaints made at a later
date will not be acknowledged.
1 pre-assembled device unit
1 operating instruction manual
S
S
y
y
m
m
b
b
o
o
l
l
s
s
o
o
n
n
t
t
h
h
e
e
m
m
a
a
c
c
h
h
i
i
n
n
e
e
Read and follow the operating
instructions and safety advices before
starting up the machine.
Switch off the air dehumidifier and
disconnect the mains power plug
before performing cleaning,
maintenance or repair work.
Do not tilt the air dehumidifier and do
not transport it in horizontal position.
12
S
S
y
y
m
m
b
b
o
o
l
l
s
s
i
i
n
n
t
t
h
h
e
e
o
o
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
i
i
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Potential hazard or hazardous situation. Failure to
observe these instructions may lead to injuries or
cause damage to property.
L
Important information on proper handling. Failure
to observe these instructions may lead to
malfunction.
User information. This information helps you to use
this machine optimally.
Assembly, operation and servicing. Here you are
explained exactly what to do.
P
P
r
r
o
o
p
p
e
e
r
r
u
u
s
s
e
e
This air dehumidifier is only designed for indoor use to dry
moist walls damage caused by water or to reduce the air
humidity in confined spaces.
The intended usage also includes compliance with the
operating, servicing and repair conditions prescribed by the
manufacturer and following the safety instructions included in
the instructions.
Follow the relevant accident prevention rules for operation and
other generally recognised health and safety at work rules.
Any other use is deemed not to be use as prescribed. The
manufacturer is not liable for any type of damage resulting
from this: the user bears the sole risk.
Unauthorised modifications on the air dehumidifier exclude a
liability of the manufacturer for damages of any kind resulting
from it.
R
R
e
e
s
s
i
i
d
d
u
u
a
a
l
l
r
r
i
i
s
s
k
k
s
s
Even if used properly, residual risks can exist even if the
relevant safety regulations are complied with due to the design
determined by the intended purpose.
Residual risks can be minimised if the “Safety advices” and
the “Intended usage” as well as the whole of the operating
instructions are observed.
Observing these instructions, and taking proper care, will
reduce the risk of personal injury or damage to the equipment.
Risk from electricity when using improper electrical
connections.
Touching live parts of opened electrical components.
In addition, in spite of all the precautionary measures taken,
non-obvious residual risks can still exist.
S
S
a
a
f
f
e
e
t
t
y
y
a
a
d
d
v
v
i
i
c
c
e
e
s
s
Before commissioning this product, read and keep to the
following advice. Also observe the accident prevention
rules of your professional association and the safety
provisions applicable in the respective country, in order
to protect yourself and others from possible injury.
L
Pass the safety instructions on to all persons who
work with the machine.
L
Keep these safety instructions in a safe place.
Make yourself familiar with the equipment before using it,
by reading and understanding the operating instructions.
Only use this machine for the intended purpose for which it
is designed (see “Proper use”).
Only start up this machine with the specified mains
voltage.
Within his area of work the operator is responsible for third
parties.
The machine must not be operated by children or young
people under 16 years of age. They are not aware of the
risks associated with the use of these devices.
Keep children away from the device.
Only operate the device with complete and correctly
attached safety equipment and do not alter anything on the
device that could impair its safety.
Do not switch on the device if it does not function properly
or was dropped causing damages to the cable or mains
powr plug or if another part shows signs of damage.
Only qualified persons are allowed to carry out repair work
on electrical equipment. The user of the device may be
severly injured due to improper repair work.
Switch off the device and disconnect the mains plug if you
do not use the device or before you transport or clean it.
Switch off the device in case of faults, disconnect the
mains plug and contact the customer service.
Never dip the device in water or another liquid.
Do not place objects on the device.
Keep foreign objects away from air inlet/outlet openings.
Drain the water container before transporting the device to
prevent spills.
Do not tilt the device, otherwise outflowing water may
cause damages to the air dehumidifier.
Never pour or spray water on the device
Electrical safety
Use an extension cable in compliance with IEC 60245 (H
07 RN-F) having a core cross-section of at least:
1.5 mm
2
for cable lengths up to 25 m
2.5 mm
2
for cable lengths over 25 m
Long and thin connection lines result in a voltage drop. The
motor does not reach any longer its maximal power; the
function of the device is reduced.
Plugs and coupler outlets on connection cables must be
made of rubber, non-rigid PVC or other thermoplastic
material of same mechanical stability or be covered with
this material.
13
When installing the power supply cable observe that it
does not interfere, is not squeezed, bended and the plug
connection does not get wet.
Wind off completely the cable when using a cable drum.
Do not use the cable for purposes for which it is not meant.
Protect the cable against heat, oil and sharp edges. Do not
use the cable to pull the plug from the socket.
Check the extension cable on a regular basis and replace
it if it is damaged.
Do not use any defective connection cables.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current
circuit breaker (30 mA).
The electrical connection or repairs to electrical parts of
the machine must be carried out by a certified electrician
or one of our customer service points. Local regulations –
especially regarding protective measures – must be
observed.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service
points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such
action.
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
p
p
r
r
i
i
n
n
c
c
i
i
p
p
l
l
e
e
This air dehumidifier works on the basis of the condensation
principle.
Room air is sucked through a filter and a refrigerating element
where water vapour in the air condense as water droplets.
Then, the water droplets flow into a condensation water bowl
and further into the water container while the dried cold air is
piped through the condenser of the device, heated and blown
again into the room. The temperature of the blown out air is
approx. 2-5 °C above the room temperature. This increase of
heat is caused by power introduced in the compressor and fan
and by heat which is released by the condensation of the
water vapour.
The relative humidity of air is gradually reduced thanks to
continuous recirculation of the room air through the device
resulting in a quick and gentle drying of the room.
L Water vapours move easily and unhindered through the
air. Therefore, it is essential to “seal” the room as tight as
possible. That means doors and windows must kept
closed and entering and leaving the room should be
restricted if possible. Otherwise the drying efficiency of
the device is considerably impaired.
L
L
o
o
c
c
a
a
t
t
i
i
o
o
n
n
o
o
f
f
t
t
h
h
e
e
a
a
i
i
r
r
d
d
e
e
h
h
u
u
m
m
i
i
d
d
i
i
f
f
i
i
e
e
r
r
Location
If possible, the air dehumidifier should be placed in the middle
of the room in order to have a good air circulation in the whole
room.
If this is not possible, locate the air dehumidifier so that air can
be sucked and discharged unhindered.
Keep a minimum distance of 10 cm to walls.
Place the air dehumidifier
horizontally to ensure that the condensed water can flow
off unhindered
away from a heat source (e.g. a radiator).
L Make sure that windows and doors of the room to be
dehumidified are closed.
Electric supply
Compare the voltage listed on the device’s type plate, e.g.
230 V / 50 Hz, with the mains voltage and connect the air
dehumidifier to a suited and and properly earthed electrical
socket.
Use an electrical socket with a rated voltage of 230 V with
a fault-current circuit breaker (30 mA).
Power system fuse protection
10 A
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
Before starting up
Did you transport the air dehumidifier in horizontal position or
at an angle large than 45°?
L Allow the device to stand in vertical position for at least
one hour.
L Notes
1. The air dehumidifier will not work if the set humidity value
is higher than that of the environment.
2. Only use the air dehumidifier at a room temperature
between 5 °C and 32 °C. The air dehumidifier will not
function out of this range.
3. Do not operate the air dehumidifier in heavily dust-laden
or chloric atmospheres.
4. Once the compressor has been started the fan motor and
the compressor must run for at least 3 minutes during
dehumidification. To prevent damages to the compressor,
you should wait for 3 minutes after a shut-down of the air
dehumidifier before you restart the device.
5. If the room temperature is under 10 °C and the relative
humidity of the ambient air is rather low an operation of
the air dehumidifier will not be necessary.
14
6. The device’s air dehumidification performance depends on
room design, room temperature and relative humidity of
the room air.
7. Drain the container when it is full. Then, reinsert the empty
water container so that the device can work again.
8. Tranport this device only in upright (vertical) position.
9. If the device does not work or if the operation is suddenly
interrupted for unknown reasons, ¨ see “Possible faults“.
10. When the air dehumidifier is in operation the compressor
generates waste heat and the room temperature slightly
increases. This is considered a normal process.
Control panel
1 ¨ ON/OFF button
2 ¨ Relative humidity (in %) or fault display
3 ¨ “Increase RH” button
4 ¨ Operating hour counter
5 ¨ “Reduce RH” button
6 ¨ Defrosting icon
7 ¨ “Fan ON” icon
8 ¨ “Water container full” icon
9 ¨ “Dehumidification mode” icon
Continuous display = dehumidfication is running
(compressor and fan on)
Flashing display = dehumidification is not
running (compressor off -
fan on)
Fault code
If the fault codes E3 – E4 – E5 are indicated in the “RH
display” ¨ see “Possible faults”.
Start-up
L An acoustic signal will sound if you connect the power
cable to an electrical socket.
A fault has occurred when this acoustic signal does not
sound. Check the power supply cable, the electrical
socket and the fuse.
Powering up
Press the button to switch on the power to the air
dehumidifier.
The display 2 ¨ “RH of air” indicates the factory-set humidity
of air of 60 %. After 5 seconds the display indicates the actual
humidity of air.
The “RH” display indicates the humidity of air in a range
between 30 % and 90 %.
Shutting down
Press the button again to switch off the power to the air
dehumidifier.
Setting the humidity value
Press the button (Increase the RH setting) or
(Reduce the RH setting) to set your desired relative humidity
of air.
If the set RH value is lower than 30 %, the device will
continuously dehumidify and the indicator 2 displays “CO”.
Hint: Normally, a relative humidity of air between 50 %
and 60 % is sufficient to have a convenient indoor
climate and to prevent condensation on structural
components and furnishing.
L If your desired RH value is lower than the actual RH by
3 %, the air dehumidifier will automatically start
(compressor). The
icon (dehumidification) is
continuously displayed.
If your desired RH value exceeds the actual RH by 3 %,
the air dehumidifier will automatically shut down
(compressor). The
icon (dehumidification) is flashing.
Automatic defroster
At a room temperature under 20 °C not only condensation
water is generated on the cold evaporator surface, but also
ice. This ice blocks the heat exchanger so that the air flow is
impeded. The built-in automatic defroster removes the ice
from the evaporator. This allows a dehumidification operation
down to a temperature of +5 °C.
During defrosting, the icon is displayed on the display, the
compressor continues to run, the fan is automatically stopped.
Once the defrosting process is finished the air dehumidifier
returns to the dehumidification mode and the
icon turns
off.
Operating hour counter
The air dehumidifier is equipped with an
operating hour counter.
The number of hours during which the device was in operation
in the past is displayed after the dehumidifier is turned on. The
amount of time during which the device remains on will be
added to the already elapsed time.
15
W
W
a
a
t
t
e
e
r
r
o
o
u
u
t
t
l
l
e
e
t
t
The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when
the collecting container is full.
L After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
icon and
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.
Removing the water collecting container
1. Turn off the device.
2. Press on the hinged cover (1)
and open it then .
3. Remove the container (pos. 2) and empty is immediately.
4. Re-insert the container. When inserting put the draining
hose (3) into the water collecting container. Make sure that
the container is correctly positioned.
5. Close the hinged enclosure cover.
6. Restart the air dehumidifier. The
icon and the fault
code E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.
Continuous or extended operation
In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In continuous
mode it is not needed to empty the water collecting container.
Proceed as follows:
1. Remove the water collecting container from the device.
2. Put the draining hose (3) through the hole
in the
enclosure and pull it out of the device on the other side
.
3. Re-insert the collecting container in the device.
4. Close the hinged enclosure cover.
5. Place a large collecting container below the water draining.
Or:
Extend the water draining using a garden hose to pipe the
water into a drain channel.
16
L Pay attention to the following:
@ Make sure that the water can flow out
unhindered.
@ Pipe the water preferably to a drain which is
positioned at a lower level.
@ Make sure that the hose remains in its position,
is routed with a descending gradient, is not
kinked or wound up.
T
T
r
r
a
a
n
n
s
s
p
p
o
o
r
r
t
t
Power off the device and disconnect the
mains plug before each transport.
Always transport the air dehumidifier in upright (vertical)
position to prevent compressor damages.
Hint: If you have transported the air dehumidifier in
another than upright position (horizontal or tilted),
allow the air dehumidifier to stand in upright position
for at least one hour before starting it up.
C
C
l
l
e
e
a
a
n
n
i
i
n
n
g
g
a
a
n
n
d
d
m
m
a
a
i
i
n
n
t
t
e
e
n
n
a
a
n
n
c
c
e
e
Turn off the device and disconnect the power
plug before each cleaning and maintenance
work.
Maintenance and repair work other than those described in
this chapter is only allowed to be carried out by service staff.
Only use genuine spare parts. Other than genuine parts may
result in unpredictable damages and injury.
Cleaning
Air filter
A contaminated filter
@ deteriorates the performance of the air dehumidifier,
@ results to contamination inside the device.
L Clean the filter in regular intervals depending on the
operating conditions.
Removing the filter
1. Remove the enclosure door (4).
2. Pull out the three fixing bars (5)
. Remove the filter (6)
from the enclosure door for cleaning
.
Slight contamination
Use a vacuum or slightly knock off the filter to clean it.
Bad contamination
Carefully wash the filter in luke-warm soapy solution (max.
40 °C) and then allow it to dry well. Do not expose the filter to
sunlight or other heat sources to dry it.
Inserting the filter
1. Place the filter in the enclosure door and secure it using
the three fixing bars.
2. Re-mount the enclosure door.
Device cleaning
Clean the device’s external surfaces using a wet cloth and a
mild cleaning solution (soapy) on a regular basis. Make sure
that no water enters the interior of the device.
Do not use detergents or solvents for cleaning because such
may attack parts of the device.
Have the interior of the air dehumidifier inspected for
contamination by service staff once in a year or more
frequently depending on the operating conditions.
17
Maintenance
The air dehumidifier is designed for a trouble-free operation
and a minimum of maintenance.
All movable parts are permanently lubricated.
Inside the device, there are no other parts to be maintained.
S
S
t
t
o
o
r
r
a
a
g
g
e
e
Store unused equipment in a dry, locked place out of the
reach of children.
Note the following to extend the service life of your air
dehumidfier and to ensure a perfect function:
@ Drain the water collecting container and dry it carefully.
@ Clean the filter.
@ Thoroughly clean the device.
@ Check the air dehumidifier for perfect condition to ensure
a safe use of it after a longer period of storage.
@ Carefully cover the air dehumidifier.
P
P
o
o
s
s
s
s
i
i
b
b
l
l
e
e
f
f
a
a
u
u
l
l
t
t
s
s
Power off the device and disconnect the mains plug before each troubleshooting.
Fault Possible cause Corrective action
No power supply. Check fuses.
Mains cable defective. Have it checked (electrician).
Water collecting container full. Drain the water collecting container.
Motor does not start
Humidity of the room air lower than the
set value.
Check the set humidity value and set another value
if required.
Room temperature or humidity of air out
of the working range.
a) Check the room temperature (5 °C to 32 °C).
b) Check the humidity of air (at least 30% RH).
c) Check the set humidity value and set another
value if required.
Air filter contaminated. Clean the air filter (see “Cleaning and
Maintenance”).
Air supply or exhaust air outlet blocked. Check. Place the device on another location of
required (adhere to the minimum distance to walls
(10 cm)).
a) Interior of the device heavily
contaminated.
b) Refrigerant circuit defective.
Contact the manufacturer or customer service.
Only little condensation or no water
Doors and/or windows open. Close doors and/or windows.
a) Drain hose kinked or wound up.
b) Not enough descending gradient.
Re-route the drain hose to allow the water to flow
out unhindered.
Device shuts down in continuous
operation with drain hose
Water frozen in the hose. Take precautions to avoid water freezing.
Fault Possible cause Corrective action
Water flows out of the device Leakage of the water collecting
container.
a) Check the water collecting container.
b) Replace the water collecting container.
Device is placed on an uneven floor. Place the device on an even floor. Unusual noise or vibrations.
Screws, nuts or other parts loosened. Tighten the parts.
If the parts cannot be tightened, are in the interior
of the device or the noise persists: Contact the
manufacturer or the responsible customer service
respectively
L Please contact the manufacturer or the customer service if you cannot eliminate a fault although you have carried out all
functional tests.
L Immediately put the device out of operation if it does not function properly.
18
Fault code
Following fault codes can be indicated in the display 2 “Relative humidity of air”:
Fault code Fault
E3 Humidity sensor defective.
E4 Water collecting container full.
E5 Refrigeration circuit sensor defective.
L Please contact the manufacturer or customer service of the fault codes E3 or E5 appear.
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
s
s
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Type HT 600 HT 800
Model ALE 600 ALE 800
Air flow rate 680 m³/h 680 m³/h
Rated power 1000 W 1200 W
Rated current consumption 4.6 A 5.3 A
Max. power 1200 W 1410 W
Max. current consumption 5.4 A 6.4 A
Power, fan 50 W 50 W
Electrical power supply 230 V~ / 50 Hz 230 V~ / 50 Hz
Power system fuse protection 10 A 10 A
Temperature range 5 – 32 °C 5 – 32 °C
Humidity of air range 30 – 90% rel. humidity of air 30 – 90% rel. humidity of air
Dehumidification performance at 30 °C / 80% RH 60 l / 24 h 80 l / 24 h
Degree of protection IP X0 IP X0
Freezing pressure 2.5 MPa 2.5 MPa
Vapour pressure 1.0 MPa 1.0 MPa
Refrigerant R 407 C R 407 C
Refrigerant quantity 0.6 kg 0,78 kg
Container volume, max. 5.8 l 5.8 l
“Tank full” LED comes up at 3.9 l 3.9 l
Room volume (at a ceiling height of 2.5 m) 150 – 200 m³ 250 – 300 m³
Room area 60 – 80 m² 100 – 120 m²
Sound power level L
WA
< 70 dB (A) < 70 dB (A)
Sound power pressure L
PA
53 dB (A) 53 dB (A)
Weight 51.5 kg 53.5 kg
20
S
S
p
p
a
a
r
r
e
e
p
p
a
a
r
r
t
t
l
l
i
i
s
s
t
t
Pos. Spare part
number
Denomination
1 417659 Hinged cover
2 417610 Water collecting container with
stopper and float switch
3 417660 Water draining hose
4 417661 Enclosure door
5 417655 Fixing bar
6 417656 Air filter
7 417657 Wheel
8 417658 Instruction label for control panel
9 417622 Float switch cpl.
10 417618 Safety label
Always indicate the following when ordering spare parts: Air dehumidifier type, year of fabrication and spare part
number.
Otherwise, no delivery is possible!
G
G
u
u
a
a
r
r
a
a
n
n
t
t
e
e
e
e
Please note the attached guarantee declaration.
48
T
T
e
e
k
k
n
n
i
i
s
s
k
k
e
e
d
d
a
a
t
t
a
a
Type HT 600 HT 800
Model ALE 600 ALE 800
Luftgennemgang 680 m³/h 680 m³/h
Nom. effekt 1000 W 1200 W
Nom. strømforbrug 4.6 A 5.3 A
maks. effekt 1200 W 1410 W
maks. strømforbrug 5.4 A 6.4 A
Effekt, ventilator 50 W 50 W
Strømforsyning 230 V~ / 50 Hz 230 V~ / 50 Hz
Netsikring 10 A 10 A
Temperaturområde 5 – 32° C 5 – 32° C
Luftfugtighedsområde 30 – 90 % rel. luftfugtighed 30 – 90 % rel. luftfugtighed
Affugtningseffekt ved 30 °C / 80 % rel. luftfugtighed 60 l / 24 h 80 l / 24 h
Beskyttelsesart IP X0 IP X0
Frysetryk 2.5 MPa 2.5 MPa
Damptryk 1.0 MPa 1.0 MPa
Kølemiddel R 407 C R 407 C
Kølemiddelmængde 0.6 kg 0.78 kg
Tankvolumen maks. 5.8 l 5.8 l
LED-indikator "Tank fuld" ved 3.9 l 3.9 l
Rumvolumen (ved en loftshøjde på 2,5 m) 150 – 200 m³ 250 – 300 m³
Rumareal 60 – 80 m² 100 – 120 m²
Lydeffektniveau L
WA
< 70 dB (A) < 70 dB (A)
Lydtryksniveau L
PA
53 dB (A) 53 dB (A)
Vægt 51.5 kg 53.5 kg
K
K
r
r
e
e
d
d
s
s
l
l
ø
ø
b
b
s
s
d
d
i
i
a
a
g
g
r
r
a
a
m
m
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

ATIKA ALE 600 Owner's manual

Category
Dehumidifiers
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI