Mitsubishi Electric C80 Series User manual

Type
User manual
Introduction
This manual is a guide for using the Mitsubishi Electric CNC C80 Series.
This manual describes operations, production processes and maintenances for users who operate the Mitsubishi Electric
CNC installed machine tool. Read this manual thoroughly before using CNC unit. Moreover study the "Precautions for Safety"
on the next page before use to use the unit safely. Be sure to keep this manual always at hand.
CAUTION
For items described as "Restrictions" or "Usable State" in this manual, the instruction manual issued by the
machine tool builder (MTB) takes precedence over this manual.
Items not described in this manual must be interpreted as "not possible".
This manual is written on the assumption that all the applicable functions are included. Some of them, however,
may not be available for your NC system. Refer to the specifications issued by the machine tool builder before
use.
Refer to the Instruction Manual issued by each MTB for details on each machine tool.
Some screens and functions may differ depending on the NC system (or its version), and some functions may
not be possible. Please confirm the specifications before use.
Do not connect NC system to the Internet-connected network.
To maintain the safety of the NC system against unauthorized access from external devices via the network,
take appropriate measures.
In this manual, the following abbreviations might be used.
L system: Lathe system
M system: Machining center system
MTB: Machine tool builder
Also refer to the manuals on "Manual List" as necessary.
Manual List
Manuals related to M800/M80/E80/C80 Series are listed as follows.
These manuals are written on the assumption that all optional functions are added to the targeted model.
Some functions or screens may not be available depending on the machine or specifications set by MTB. (Confirm the
specifications before use.)
The manuals issued by MTB take precedence over these manuals.
Manual IB No. Purpose and Contents
M800/M80/E80 Series
Instruction Manual
IB-1501274
Operation guide for NC
Explanation for screen operation, etc.
C80 Series
Instruction Manual
IB-1501453
Operation guide for NC
Explanation for screen operation, etc.
M800/M80/E80/C80 Series
Programming Manual
(Lathe System) (1/2)
IB-1501275
G code programming for lathe system
Basic functions, etc.
M800/M80/E80/C80 Series
Programming Manual
(Lathe System) (2/2)
IB-1501276
G code programming for lathe system
Functions for multi-part system, high-accuracy function, etc.
M800/M80/E80/C80 Series
Programming Manual
(Machining Center System) (1/2)
IB-1501277
G code programming for machining center system
Basic functions, etc.
M800/M80/E80/C80 Series
Programming Manual
(Machining Center System) (2/2)
IB-1501278
G code programming for machining center system
Functions for multi-part system, high-accuracy function, etc.
M800/M80/E80 Series
Alarm/Parameter Manual
IB-1501279
Alarms
Parameters
C80 Series
Alarm/Parameter Manual
IB-1501560
Alarms
Parameters
Manuals for MTBs (NC)
Manuals for MTBs (drive section)
Manual IB No. Purpose and Contents
M800/M80/E80/C80 Series
Specifications Manual (Function)
IB-1501505
Model selection
Outline of various functions
M800/M80/E80/C80 Series
Specifications Manual (Hardware)
IB-1501506
Model selection
Specifications of hardware unit
M800W/M80W Series
Connection and Setup Manual
IB-1501268
Detailed specifications of hardware unit
Installation, connection, wiring, setup (startup/adjustment)
M800S/M80/E80 Series
Connection and Setup Manual
IB-1501269
Detailed specifications of hardware unit
Installation, connection, wiring, setup (startup/adjustment)
C80 Series
Connection and Setup Manual
IB-1501452
Detailed specifications of hardware unit
Installation, connection, wiring, setup (startup/adjustment)
M800/M80/E80 Series
PLC Development Manual
IB-1501270
Electrical design
I/O relation (assignment, setting, connection), field network
Development environment (PLC on-board, peripheral
development environment), etc.
M800/M80/E80 Series
PLC Programming Manual
IB-1501271
Electrical design
Sequence programming
PLC support functions, etc.
M800/M80/E80/C80 Series
PLC Interface Manual
IB-1501272
Electrical design
Interface signals between NC and PLC
M800/M80/E80 Series
Maintenance Manual
IB-1501273
Cleaning and replacement for each unit
Other items related to maintenance
C80 Series
Maintenance Manual
IB-1501454
Cleaning and replacement for each unit
Other items related to maintenance
Manual IB No. Contents
MDS-E/EH Series
Specifications Manual
IB-1501226 Specifications for power supply regeneration type
MDS-E/EH Series
Instruction Manual
IB-1501229 Instruction for power supply regeneration type
MDS-EJ/EJH Series
Specifications Manual
IB-1501232 Specifications for regenerative resistor type
MDS-EJ/EJH Series
Instruction Manual
IB-150
1235 Instruction for regenerative resistor type
MDS-EM/EMH Series
Specifications Manual
IB-1501238
Specifications for multi-hybrid, power supply regeneration
type
MDS-EM/EMH Series
Instruction Manual
IB-1501241 Instruction for multi-hybrid, power supply regeneration type
DATA BOOK IB-1501252 Specifications of servo drive unit, spindle drive unit, motor, etc.
Manuals for MTBs (Others)
For M800/M80/E80 Series
Manual No. Purpose and Contents
GOT2000 Series User’s Manual
(Hardware)
SH-081194
Outline of hardware such as part names, external dimensions,
installation, wiring, maintenance, etc. of GOTs
GOT2000 Series User’s Manual
(Utility)
SH-081195
Outline of utilities such as screen display setting, operation
method, etc. of GOTs
GOT2000 Series User’s Manual
(Monitor)
SH-081196 Outline of each monitor function of GOTs
GOT2000 Series Connection
Manual (Mitsubishi Electric
Products)
SH-081197
Outline of connection types and connection method between
GOT and Mitsubishi Electric connection devices
GT Designer3 (GOT2000) Screen
Design Manual
SH-081220
Outline of screen design method using screen creation
software GT Designer3
Manual No. Purpose and Contents
GOT2000/GOT1000 Series CC-Link
Communication Unit User's Manual
IB-0800351
Explanation for handling CC-Link communication unit (for
GOT2000 series/GOT1000 series)
GX Developer Version 8 Operating
Manual (Startup)
SH-080372E
Explanation for system configuration, installation, etc. of PLC
development tool GX Developer
GX Developer Version 8 Operating
Manual
SH-080373E
Explanation for operations using PLC development tool GX
Developer
GX Converter Version 1 Operating
Manual
IB-0800004E
Explanation for operations using data conversion tool GX
Converter
GX Works2 Installation Instructions BCN-P5999-0944
Explanation for the operating environment and installation
method of GX Works2
GX Works2 Version 1 Operating
Manual (Common)
SH-080779ENG
Explanation for the system configuration of GX Works2 and
the functions common to Simple project and Structured project
such as parameter setting, operation method for the online
function
GX Works2 Version 1 Operating
Manual (Simple Project)
SH-080780ENG
Explanation for methods for such as creating and monitoring
programs in Simple project of GX Works2
GX Works2 Version 1 Operating
Manual (Simple Project, Function
Block)
SH-080984ENG
Explanation for methods for such as creating function blocks,
pasting function blocks to sequence programs, and operating
FB library in Simple project of GX Works2
GX Works2 Version 1 Operating
Manual (Structured Project)
SH-080781ENG
Explanation for methods for such as creating and monitoring
programs in Structured project of GX Works2
GX Works3 Installation Instructions BCN-P5999-0391
Explan
ation for the operating environment and installation
method of GX Works3
MELSEC-Q CC-Link System Master/
Local Module User’s Manual
SH-080394E
Explanation for system configuration, installation, wiring, etc.
of master/local modules for CC-Link system
GOT2000 Series Connection
Manual (Non-Mitsubishi Electric
Products 1)
SH-081198ENG
Explanation for connection types and connection method
between GOT and other company's devices
GOT2000 Series Connection
Manual (Non-Mitsubishi Electric
Products 2)
SH-081199ENG
GOT2000 Series Connection
Manual (Microcomputers, MODBUS/
Fieldbus Products, Peripherals)
SH-081200ENG
Explanation for connection types and connection method
between GOT and microcomputers, MODBUS/fieldbus
products, peripherals
GT SoftGOT2000 Version1
Operating Manual
SH-081201ENG
Explanation for system configuration, screen configuration
and operation method of monitoring software GT
SoftGOT2000
For C80 Series
Reference Manual for MTBs
Manual No. Purpose and Contents
MELSEC iQ-R Module Configuration
Manual
SH-081262
Outline of system configuration, specifications, installation,
wiring, maintenance, etc.
MELSEC iQ-R CPU Module User’s
Manual (Startup)
SH-081263
Outline of specifications, procedures before operation,
troubleshooting, etc. for CPU module
MELSEC iQ-R CPU Module User’s
Manual (Application)
SH-081264
Outline of memory, functions, devices, parameters, etc. for
CPU module
MELSEC iQ-R CC-Link IE Field
Network User's Manual (Application)
SH-081259
Explanation for functions, parameter settings, programming,
troubleshooting, etc. of the CC-Link IE Field Network function
QCPU User’s Manual (Hardware
Design, Maintenance and
Inspection)
SH-080483
Outline of specifications, necessary knowledge to configure
the system and maintenance-related descriptions for Q series
CPU module, etc.
GX Works3 Operating Manual SH-081215 Outline of functions, programming, etc.
Manual No. Purpose and Contents
M800/M80 Series Smart safety
observation Specification manual
BNP-C3072-022
Explanation for smart safety observation function
C80 Series Smart safety observation
Specification manual
BNP-C3077-022
M800/M80 Series CC-Link (Master/
Local) Specification manual
BNP-C3072-089 Explanation for CC-Link
M800/M80 Series PROFIBUS-DP
Specification manual
BNP-C3072-118 Explanation for PROFIBUS-DP communication function
M800/M80 Series Interactive cycle
insertion (Customization)
Specification manual
BNP-C3072-121-
0003
Explanation for interactive cycle insertion
M800/M80 Series EtherNet/IP
Specifications manual
BNP-C3072-263 Explanation for EtherNet/IP
M800/M80 Series CC-Link IE Field
(Master/local) Specifications manual
BNP-C3072-283 Explanation for CC-Link IE Field
M800/M80 Series GOT Connection
Specifications manual
BNP-C3072-314 Explanation for GOT connection
M800/M80 Series CC-Link IE Field
Basic Specifications manual
BNP-C3072-337 Explanation for CC-Link IE Field Basic
Precautions for Safety
Always read the specifications issued by the MTB, this manual, related manuals and attached documents before installation,
operation, programming, maintenance or inspection to ensure correct use. Understand this numerical controller, safety items
and cautions before using the unit.
This manual ranks the safety precautions into "DANGER", "WARNING" and "CAUTION".
Note that even items ranked as " CAUTION", may lead to major results depending on the situation. In any case, important
information that must always be observed is described.
The following signs indicate prohibition and compulsory.
The meaning of each pictorial sign is as follows.
Mitsubishi Electric CNC is designed and manufactured solely for applications to machine tools to be used for industrial purpos-
es. Do not use this product in any applications other than those specified above, especially those which are substantially influ-
ential on the public interest or which are expected to have significant influence on human lives or properties.
Not applicable in this manual.
DANGER
When the user may be subject to imminent fatalities or major injuries if handling is mistaken.
WARNING
When the user may be subject to fatalities or major injuries if handling is mistaken.
CAUTION
When the user may be subject to bodily injury or when physical damage may occur if handling is mistaken.
This sign indicates prohibited behavior (must not do).
For example, "Keep fire away" is indicated by .
This sign indicates a thing that is critical (must do).
For example, "it must be grounded" is indicated by .
CAUTION
CAUTION rotate ob-
ject
CAUTION HOT
Danger Electric
shock risk
Danger explosive
Prohibited
Disassembly is pro-
hibited
KEEP FIRE AWAY
General instruction
Earth ground
For Safe Use
DANGER
WARNING
1. Items related to program development
Do not assign any startup switch for C80 on GOT's touch key. If a communication fault (including cable discon-
nection) occurs between GOT and CNC C80, the communication will be suspended and the GOT will become in-
operative. In this case, even when you release your hands from the startup switch, CNC will fail to recognize the
cutoff of startup signal, which may cause serious accidents.
2. Items related to operation
If the operation start position is set from a block in the program and the program is started, the program before
the set block is not executed. Please confirm that G and F modal and coordinate values are appropriate. If there
are coordinate system shift commands or M, S, T and B commands before the block set as the start position, carry
out the required commands using the MDI, etc. If the program is run from the set block without carrying out these
operations, there is a danger of interference with the machine or of machine operation at an unexpected speed,
which may result in breakage of tools or machine tool or may cause damage to the operators.
Under the constant surface speed control (during G96 modal), if the axis targeted for the constant surface speed
control moves toward the spindle center, the spindle rotation speed will increase and may exceed the allowable
speed of the workpiece or chuck, etc. In this case, the workpiece, etc. may jump out during machining, which may
result in breakage of tools or machine tool or may cause damage to the operators.
CAUTION
1. Items related to product and manual
For items described as "Restrictions" or "Usable State" in this manual, the instruction manual issued by the ma-
chine tool builder (MTB) takes precedence over this manual.
Items not described in this manual must be interpreted as "not possible"
This manual is written on the assumption that all the applicable functions are included. Some of them, however,
may not be available for your NC system. Refer to the specifications issued by the machine tool builder before use.
Refer to the Instruction Manual issued by each MTB for details on each machine tool.
Some screens and functions may differ depending on the NC system (or its version), and some functions may not
be possible. Please confirm the specifications before use.
Do not connect NC system to the Internet-connected network.
To maintain the safety of the NC system against unauthorized access from external devices via the network, take
appropriate measures.
2. Items related to installation and assembly
Ground the signal cables to ensure stable system operation. Also ground the NC unit main frame, power distribu-
tion panel and machine to one point, so they all have the same potential.
3. Items related to preparation before use
Always set the stored stroke limit. Failure to set this could result in collision with the machine end.
Always turn the power OFF before connecting/disconnecting the input/output device cable. Failure to do so could
damage the input/output device and NC unit.
4. Items related to screen operation
If the tool compensation amount or workpiece coordinate system offset amount is changed during automatic op-
eration (including during single block stop), the changes will be valid from the command in next block or after sev-
eral subsequent blocks.
All of the various data in the NC memory is erased when formatting. Be sure to use the transfer function to transfer
all necessary data to another storage device before formatting.
Pay close attention to the sequence operation when carrying out forced data setting (forced output) in the I/F di-
agnosis screen during machine operation.
The program including a character of any language other than the display language is not correctly displayed. Do
not edit such a program. Any part of the program other than the comment part may also be changed if edited.
To prevent influence from data omission and data transformation in the communication circuit, always verify the
data after inputting and outputting machining programs.
Do not change setup parameters without prior approval from the MTB.
5. Items related to programming
If there is no value after the G command, the operation will be the "G00" operation when the program is run due
to key chattering, etc., during editing.
" ; ", "EOB", "%", and "EOR" are symbols used for explanation. The actual codes for ISO are "CR, LF" ("LF") and
"%". "%" and "EOR" are represented by "%" in ISO.
The programs created on the edit screen are stored in the NC memory in a "CR, LF" format, however, the programs
created with external devices may be stored in an "LF" format.
The actual codes for EIA are "EOB (End of Block)" and "EOR (End of Record)".
Do not change the fixed cycle program without prior approval from the MTB.
6. Items related to operation
Do not enter the machines movable range during automatic operation. During rotation, keep your hands, feet and
face away from the spindle.
Carry out dry operation before actually machining, and confirm the machining program, tool offset and workpiece
coordinate system offset.
If the operation start position is set from a block in the program and the program is started, the program before
the set block is not executed. If there are coordinate system shift commands or M, S, T, and B commands before
the block set as the starting position, carry out the required commands using the MDI, etc. There is a danger of
interference with the machine if the operation is started from the set starting position block without carrying out
these operations.
Program so the mirror image function is turned ON/OFF at the mirror image center. The mirror image center will
deviate if the function is turned ON/OFF at a position other than the mirror image center.
7.Items related to faults and abnormalities
If the battery low warning is issued in the drive unit side, immediately replace the battery. Replace the batteries
while applying the drive unit's control power.
If the axis overruns or emits an abnormal noise, immediately press the emergency stop button and stop the axis
movement.
Turn OFF the power immediately if any smoke, abnormal noise or odor is generated from the controller, drive unit
or motor.
8. Items related to maintenance
Incorrect connections may damage the devices. Always connect the cables to the indicated connectors.
Do not apply voltages other than those indicated according to specification on the connector. Failure to observe
this could cause bursting, damage, etc.
Do not connect or disconnect the connection cables between each unit while the power is ON.
Do not connect the cable by pulling on the cable wire.
Do not short circuit, charge, overheat, incinerate or disassemble the battery.
Dispose the spent battery according to local laws.
Dispose the spent cooling fan according to local laws.
Do not replace each control unit while the power is ON.
Do not replace the operation panel I/O unit while the power is ON.
Do not replace the cooling fan while the power is ON.
CAUTION
Do not replace the battery while the power is ON.
Read the manual carefully and pay careful attention to safety for the on-line operation (especially program change,
forced stop or operation change) performed by connecting peripheral devices to the CNC CPU module during op-
eration. Erroneous operation may cause machine breakage or accident.
Never try to disassemble or modify modules. It may cause product failure, operation failure, injury or fire.
Use any radio communication device such as a cellular phone or a PHS phone more than 25cm away in all direc-
tions of C80. Failure to do so may cause a malfunction.
Completely turn off the externally supplied power used in the system before installation or removing the module.
Not doing so could result in electric shock, damage to the module or operation failure.
Do not install/remove the module on to/from base unit or terminal block more than 50 times, after the first use of
the product. Mounting/dismounting over 50 times may cause an operation failure.
Do not drop or impact the battery to be installed to the module. That may damage the battery, causing battery liq-
uid to leak in the battery. Do not use the dropped or impacted battery, but dispose of it.
Before touching the unit, always touch a metal with a ground section to discharge any static electricity in the hu-
man body etc. If static electricity is not discharged, the breakdown and the malfunction of the unit are caused.
Do not directly touch the module's conductive parts and electronic components. Touching them could cause an
operation failure or give damage to the module.
Do not touch the heat radiating fins of CNC CPU module while the power is ON and for a short time after the power
is turned OFF. In this timing, these parts become very hot and may lead to burns. Remove the modules with close
attention.
When connecting to a personal computer and a unit with the USB interface, an electric shock or a unit failure may
occur.
Operate these correctly according to the manual of a unit and a personal computer.
Observe the following cautions when a personal computer in an AC power supply is used.
(1) For a personal computer that uses a 3-pin power plug or power plug with a ground lead type, make sure to use
a plug socket including a ground input electrode or ground the earth lead, respectively.
And, ensure to ground a personal computer and a unit with Class D or higher grounding (Ground resistance:
100Ω or less).
(2) For a personal computer that uses a 2-pin power plug without ground lead, make sure to connect the unit to
the personal computer according to the following procedures. And, it is recommended to supply the same pow-
er supply line to a personal computer and the unit.
(a) Pull out the power plug of the personal computer from the AC outlet.
(b) Confirm that the power plug of the personal computer has been pulled out from the AC outlet, and connect
USB cables, the extension cable or the bus connection cable of a GOT.
(c) Insert the power plug of the personal computer into the AC outlet.
Before using this product after a long period of storage, performance check must be conducted. Otherwise con-
tact the MTB of your machine tool.
CAUTION
The metal part becomes the high temperature.
9. Other items
Mitsubishi Electric CNC C80, which is an open equipment, must be installed within a sealed metal control panel
(IP54 or higher). C80 must also be used and stored under the conditions listed in the table of specifications below.
(*1) This indicates the section of the power supply to which the equipment is assumed to be connected between the public
electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge withstand voltage for the equipment up to the rated 300V is 2500V.
(*2) This index indicates the degree to which conductive material is generated in terms of the environment in which the
equipment is used.
Pollution level 2 is when only non-conductive pollution occurs; however, a temporary conductivity caused by condensing
must be expected occasionally.
(*3) Do not use or store C80 under pressure higher than the atmospheric pressure of altitude 0m. Doing so can cause an
operation failure.
(1) The following environment conditions are required for the layout design.
No large amount of conductible dust, iron filings, oil mist, salt, or organic solvents
No direct sunlight
No strong electrical or magnetic fields
No direct vibrations nor shocks on C80
CAUTION
Item Specification
Ambient tempera-
ture
During operation 0 to 55 °C
During storage -25 to 75 °C
Ambient Humidity During operation 5 to 95%RH, non-condensing
During storage 5 to 95%RH, non-condensing
Vibration resis-
tance
Compliant
with JIS B
3502 and IEC
61131-2
Frequency Constant accel-
eration
Half amplitude Sweep count
Under intermit-
tent vibration
5 to 8.4Hz - 3.5mm 10 times each in X,
Y, Z directions (For
80 min.)
8.4 to 150Hz
9.8m/s
2
-
Under continuous
vibration
5 to 8.4Hz - 1.75mm
8.4 to 150Hz
4.9m/s
2
-
Shock resistance
147m/s
2
, 3 times in each of 3 directions X, Y, Z
Operating atmosphere No corrosive gases nor inflammable gases
Altitude 2000m or less (*3)
Installation location Inside control panel
Overvoltage category (*1) II or less
Pollution level (*2) 2 or less
Note
Treatment of waste
The following two laws will apply when disposing of this product. Considerations must be made to each law. The
following laws are in effect in Japan. Thus, when using this product overseas, the local laws will have a priority. If
necessary, indicate or notify these laws to the final user of the product.
(1) Requirements for "Law for Promotion of Effective Utilization of Resources"
(a) Recycle as much of this product as possible when finished with use.
(b) When recycling, often parts are sorted into steel scraps and electric parts, etc., and sold to scrap contractors.
Mitsubishi recommends sorting the product and selling the members to appropriate contractors.
(2) Requirements for "Law for Treatment of Waste and Cleaning"
(a) Mitsubishi recommends recycling and selling the product when no longer needed according to item (1) above.
The user should make an effort to reduce waste in this manner.
(b) When disposing a product that cannot be resold, it shall be treated as a waste product.
(c) The treatment of industrial waste must be commissioned to a licensed industrial waste treatment contractor,
and appropriate measures, including a manifest control, must be taken.
(d) Batteries correspond to "primary batteries", and must be disposed of according to local disposal laws.
Disposal
(Note) This symbol mark is for EU countries only.
This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and
Annex II.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components
which can be recycled and/or reused.
This symbol means that batteries and accumulators, at their end-of-life, should be disposed of separately from your
household waste.
If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the battery or
accumulator contains a heavy metal at a certain concentration. This will be indicated as follows:
Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)
In the European Union there are separate collection systems for used batteries and accumulators.
Please, dispose of batteries and accumulators correctly at your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
Trademarks
MELDAS, MELSEC, EZSocket, EZMotion, iQ Platform, MELSEC iQ-R, MELSOFT, GOT, CC-Link, CC-Link/LT,
CC-Link IE, CC-Link IE/field, EcoMonitorLight and SLMP are either trademarks or registered trademarks of
Mitsubishi Electric Corporation in Japan and/or other countries.
Ethernet is a registered trademark of Xerox Corporation in the United States and/or other countries.
Microsoft®, Windows®, SQL Server® and Access® are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries.
SD logo and SDHC logo are either registered trademarks or trademarks of LLC.
UNIX is a registered trademark of The Open Group in the United States and/or other countries.
Intel® and Pentium® are either trademarks or registered trademarks of Intel Corporation in the United States and/or
other countries.
MODBUS® is either a trademark or a registered trademark of Schneider Electric USA, Inc. or the affiliated
companies in Japan and/or other countries.
EtherNet/IP is a trademark of Open DeviceNet Vendor Association,Inc.
PROFIBUS-DP and PROFINET are either trademarks of Profibus International.
Oracle® is a registered trademark of Oracle Corporation, the subsidiaries, or the affiliated companies in the United
States and /or other countries.
VNC is a registered trademark of RealVNC Ltd. in the United States and other countries.
Other company and product names that appear in this manual are trademarks or registered trademarks of the
respective companies.
本製品の取扱いについて
( 日本語 /Japanese)
本製品は工業用 ( クラス A) 電磁環境適合機器です。販売者あるいは使用者はこの点に注意し、住商業環境以外での使
用をお願いいたします。
Handling of our product
(English)
This is a class A product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
본 제품의 취급에 대해서
( 한국어 /Korean)
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정외의 지역에 서
용하는 것을 목적으로 합니다 .
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462

Mitsubishi Electric C80 Series User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI