Page 2 of 2
Printed in U.S.A. © 2015 Innovative Hearth Products
P/N 900355-07, REV. A, 11/2017
MONTEBELLO™ ST
Product Reference Information
Cat.# Model Ship.Wt. Ship. Volume
F2228 Montebello STTEN 383 lb. 52.2 cu. ft.
F2229 Montebello STTEP 383 lb. 52.2 cu. ft.
Listing Information
When the unit is installed with
one side flush with a wall, the
wall on the other side of the
unit must not extend beyond
the front edge of the unit.
Outdoors
Indoors
Top View
Shelf Height
Typical Installations
7 (178)
2
(51)
4
(102)
6
(152)
8
(203)
10
(254)
12
(305)
9 (229)
13 (330)
17 (432)
15 (381)
11 (279)
Mantel Depth
Side View
Clearances from any pro-
jections such as shelves,
window sills, mantels, etc.
above the appliance
Mantel Clearances
Minimum Clearances - Inches (millimeters)
Back / Sides 0 (0) Spacers
Floor 0 (0)
Bottom of Appliance To Ceiling 72 (1829)
Vent 4 (102) Top, 1 (25) Sides & Bottom
Service Clearances
Front 36” (914 mm)
Minimum Clearances
Product Information
NOTE: Diagrams, illustrations and photographs are not to scale
– consult installation instructions. Product designs, materials,
dimensions, specifications, colors and prices are subject to change
or discontinuance without notice.
Combustible materials may
project beyond the sides
of the fireplace opening
as long as they are kept
within the shaded areas
illustrated here.
Combustible Materials
Allowed In Shaded Area
“Safe Zone”
Combustible Walls
shown in dark gray
At 8-1/4" side
wall clearance, a
combustible wall
can project 12"
1/2"
(13 mm)
5”
(127 mm)
8-1/4"
(209 mm)
14"
(356 mm)
12”
(305 mm)
17”
(432 mm)
Top View of
Fireplace
45 °
At 14" minimum
side wall clearance,
a combustible wall
can project to any
length.
Protected wall shown in white
Listed by PFS Corporation to to
ANSI Z21.88 (in Canada, CSA-
2.33), and CAN/CGA-2.17-M91
(CSA P4.1) in both USA and
Canada, as a vented gas fireplace.
Drywall
Top Of Fireplace
Opening
®
Report No. 14-107
Inputs (BTU/hr)
Model Fuel Inputs (BTU/hr)
Montebello STTEN NG
40,000 to 60,000
Montebello STTEP LP
43,500 to 56,000
Min. 2 ft vertical
vent section
and one 90-degree
elbow required
Combustible
Enclosure/Shelf
Min. 4"
(102 mm)
90" (2287 mm)
minimum
Indoor/Outdoor
91-1/2" (2324 mm)
minimum
Indoor/Outdoor
Top of
Fireplace
2 x 4
~
~
Do NOT insulate space between
appliance and area above it.
Inches (millimeters)
Top of
Fireplace
See Page 1 for Minimum
Distance to Base of Appliance
Horizontal Termination
Firestop/Spacer (SV8HF4)
shown on exterior side of wall
13”
(330mm)
6-1/2”
(165mm)
16”
(406mm)
1”
(26mm)
Square
Termination
(SV8HTS4)
NOTE: Centerline of vent piping
is NOT the same as centerline
of framed opening.
Adaptor
SV8RCH
6” to 48” Vent Section
or Telescopic Vent Section
Base of Appliance
4”
(102 mm)
1”
(26 mm)