TECHNICAL FEATURES
Thanks to its advanced electronic engineering and innovative design concept, the
TAS2000 weather proof telephone set is indispensable for installation in the loud
industry with very hard environmental conditions and outdoor.
It has been conceived for direct connection to C.O. telephone lines or connection to
subscriber lines (PABX and equivalent) with 60V, 48V or 24V power supply.
MAIN CHARACTERISTICS AND FEATURES
Pulse (with break/make ratio 1,6 or 2) and DTMF dialling
Flash key
Last number redial
Receiving volume adjusting
Housing entirely metallic in heavy-gauge cast light alloy, protection degree IP66
Handset made of heavy-gauge shock-proof resin
Handset cord protected by a stainless steel spiralled sheath
Dialling keypad/made entirely with metal vandal-proof push buttons
Handset hook magnetic type, without moving parts
Amplified dynamic capsules that assure excellent voice fidelity
Noise cancelling microphone in option
High efficiency electronic call ringer with adjustable volume
Terminals for connecting an additional loud ringer
TECHNICAL DATA
RINGING output tone frequency: 600 to 850 Hz
tone variation frequency: 10 Hz
sound intensity at 1 m distance: approx. 95 dB
PULSE DIALLING frequency 10 Hz
break/make ratio 1,6 or 2
DTMF DIALLING: conforming with CEI/IEC standards
(Q23 according to ITU-T)
NOMINAL PABX VOLTAGE: 24V, 48V, 60V
OPERATING AMBIENT
TEMPERATURE: -20°C to +60°C
PROTECTION DEGREE: IP66
WEIGHT: 6 kg
AC5070EN/1003 Page 4 of 8
INSTALLATION
Fix the telephone set case to the wall using the 2 position fixing brackets supplied
with the equipment.
Open the front side pivoting it of 90°
Make the settings in compliance with the installation and users exigencies
Connect the telephone line trough the 1/2" cable gland to A, B terminals
(M1 terminal block)
Lift the handset
Press the "Reset" key (this procedure sets the correct volume and tone of ringer
and the correct receiving volume)
Hang up
Connect the Earth Loop (eventual)
In case of necessity to connect an additional call repeater, take out the 1/2" plug,
put a suitable 1/2" cable gland, insert the two wires for the call repeater connection
and connect them to the terminals S1 - S2 (M1 terminal block)
The telephone sets series TAS2000 have too, on request, the possibility to mount a
second contact on the hook switch, for particular applications. In this case will be
present too, the terminals A2 A1 (M2 terminal block), where connecting the relevant
wires.
LAST NUMBER REDIAL
The last number dialled can be repeated by pressing the "RP" key.
One or more initial digits of the last number dialled can be repeated manually.
The following depression of the "RP" key will dial the rest of the digits stored in
memory.
This is useful when the telephone is connected to a PABX to redial an external
number.
Example: the last number dialled is 987654 (where 9 is the access code to the CO line)
off hook, wait for PABX tone
press 9 and wait for external tone
press "RP", 87654 will be dialled out
If the initial digits dialled manually do not match the initial digits of the last number
dialled, the contents of last number memory will be replaced by the new number.
KEY'S FUNCTIONS
R EARTH / FLASH KEY
X LINE RESET KEY
RP REDIAL / PAUSE KEY
0 ÷ 9 - * - # DIAL KEYS
VOL+ / VOL- RECEIVIG VOLUME ADJUSTING
AC5070EN/1003 Page 5 of 8
SETTINGS
MODE (J7)
33/66 PULSE dialling - Pulse ratio 33/66 ms (M/B)
40/60 PULSE dialling - Pulse ratio 40/60 ms (M/B)
MF DTMF(TONE) dialling
MODE OPTIONAL (J8)
33/66*MF PULSE dialling-Pulse ratio 33/66 ms (M/B)
pressing "*" changes temporary to MF
sending "*" to the line on first key entry
MF 82/160 MF duration 82ms pause 160ms
33/66 20 pps PULSE dialling - Pulse ratio 33/66 ms (M/B), 20 pps
40/60 20 pps PULSE dialling - Pulse ratio 40/60 ms (M/B), 20 pps
FLASH/EARTH (J10/J9)
FLASH (J10) "R" key = Flash signalling
EARTH (J9) "R" key = Earth Loop signalling
FLASH TIME(J11)
100 FLASH = 100 ms
270 FLASH = 270 ms
600 FLASH = 600 ms
C.O.LINE/PABX(J6, J12, J13)
C.O.LINE RX(J12), TX(J13) set to <+> AGC(J6) set to <ON>
PABX RX(J12), TX(J13) set to <-> AGC(J6) set to <OFF>
RING VOL Ringer volume adjustment
R
I
C
+
R
I
C
-
M
I
C
-
M
I
C
+
FS1
FS2
FS3
FS4
TX
J13
RINGER
VOLUME BUZZER OUT
RESET
J12
RX
J6
AGC
OFF
ON
J7
M2 M1
J8 J9
EARTH
FLASH
270
600
100
40/60
MF
33/66
33/66 20PPS
40/60 20PPS
MF 82/160
40/60 *MF
J10 J11
HANDSET
A2
A1
S1
T B A
-
-
AC5070EN/1003 Page 6 of 8
270
140
TOP CABINET
ROTATION PIN
145
230
260
N.4 fixing holes
Ø 10mm
EARTH
TERMINAL
4
44
4
7
77
7
5
55
5
8
88
8
0
00
0
X
XX
X
6
66
6
9
99
9
RP
RPRP
RP
2
22
2
3
33
3
R
RR
R
VOL
VOLVOL
VOL
-
--
-
VOL
VOLVOL
VOL
+
++
+
1
11
1
KEY'S FUNCTIONS:
R
X
RP
VOL-/VOL+
0÷9 - * - #
= EARTH / FLASH KEY
= LINE RESET KEY
= REDIAL / PAUSE KEY
= RECEIVING VOLUME ADJUSTING
= DIAL KEYS
A
B
TS1
S2
TELEPHONE
LINE CABLE
OPEN BASE CABINET
PCB
I/O CONNECTIONS
TERMINAL BLOCK
OPEN TOP
CABINET
A1A2
S2
S1
T
B
A
A2
A1
300
185
CABLE GLAND
1/2" GAS
UNI ISO 228/1
F I T R E S.p.A. - electronics • telecommunications
20142 Milan Italy via Valsolda, 15
phone: (+39)02.8959.01 • telefax: (+39)02.8959.0400
e-mail: info@fitre.it • internet http://www.fitre.it
Branch Offices in Roma and Venice
Certified DNV Italy
CERT-00403-95-AQ-MIL-SINCERT
SINCE 1943
AC5070EN/1003
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Optimus TAS-2000RV User manual

Category
Telephones
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI