Silent Alert PG3A-2204-EU Quick start guide

Type
Quick start guide
Quick start guide PG3A-2204-EU
Vibrating Pager unit
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Any questions? Call us on 01246 450789
TM
Silent
Alert
TM
Silent
Alert
OFF
A
B
5
4
3
2
1
Event Keys
Belt clip
Configuration keys
Charging Socket
OFF
A
B
5
4
3
2
1
1.
Move the ON/OFF switch
to the on position (to the
right, away from off).
The pager will illuminate
each key then vibrate.
The pager is now ready
to use.
2. Install the alarm clock or trickle charger
(Part no's. CH3A-2205-IN ,
TR3A-2206-EU), insert the Pager into the
charging slot and charge for 24 hours.
The battery key on the Pager will light
green briefly upon docking confirming the
Pager is docked correctly.
If a pillow pad is fitted it will vibrate 3
times when the Pager is docked.
3. Install the Silent Alert
monitor units according
to their instructions.
4. To re-set the Pager and stop
the vibration, press and hold
the key that is lit.
Each signal will automatically
cancel after 20-40 seconds.
Smoke & CO signals will run
for 15 minutes to comply with
British standards
Silent Alert
TM
Fire Safe
Compatible
Silent
AlertTM
5. The battery key will flash
green every 45 seconds to
indicate the Pager is
switched on.
The Pager must be recharged each night
and if not in use for more than 24 hours
should be switched off.
6.
If the Pager becomes flat it
will vibrate and the battery
key will light up.
The battery key will flash
orange until the Pager
is recharged.
If the low battery sequence
alternates with another event
key, that monitor has a
low battery.
Silent Alert
TM
Fire Safe
Compatible
Silent
AlertTM
7.
We recommend a full 24 hour charge before using our equipment.
In an emergency a few hours charge may be sufficient for short time use but this is not advised.
Silent Alert
TM
Fire Safe
Compatible
Silent
AlertTM
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
Silent Alert
TM
Fire Safe
Compatible
Silent
AlertTM
12:14
SNZ
PM
Z Z
Advanced settings PG3A-2204-EU
Vibrating Pager unit
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Any questions? Call us on 01246 450789
TM
Silent
Alert
OFF
A
B
5
4
3
2
1
1.
With the Pager switched
on, move switch 5 to
the left
(away from the belt clip).
2.
This will increase the range
of the Pager from 100M
(in open air),
to approximately 1000M
(in open air).
Operating Range
500M
Increasing system range
It is possible to make the Pager more sensitive when larger areas need to be covered.
Changing the system channel code
NOTE. In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other SA3000 systems using up to a maximum of 16 channels.
The Pager is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
all monitors to be used in the system.
NOTE. SA3000 receivers have an ON/OFF
switch, SA3000 monitors do not.
23456 7 8
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
9 10 1211 13 14 15 16
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
OFF
A
B
5
4
3
2
1
Here we have a SA3000 Pager and Mini Monitor set to
system channel 2.
Ensure when setting system channel keys you remember to ignore the
Pagers ON/OFF switch or the equipment will be on different
system channels .
The diagram to the right shows an incorrect attempt to set the system
to channel code 2 (shown as an example to avoid possible confusion).
The correct settings are shown to the left.
OFF
A
B
5
4
3
2
1
1 2 3 4 5 6 7 8
INCORRECT
OFF
A
B
5
4
3
2
1
1 2 3 4 5 6 7 8
CORRECT
  • Page 1 1
  • Page 2 2

Silent Alert PG3A-2204-EU Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document