Trident Boilers: SF160, SF260, SF360
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND/OR USE YOUR NEW BOIL-
ER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
IF THIS HARMAN BOILER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR
YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE
DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PER-
MIT.
Cette guide d’utilisation est disponible en francais. Chez votre concessionnaire de Harman Stove Company.
SAVE THESE INSTRUCTIONS
R3
2
3
Congratulations,
Youhavejustpurchasedthenestwood/coalboileravailable.HarmanTridentboilersare
constructedofhighqualitymaterialsandaremanufacturedbyahighlyskilledteamofassemblymen.
Eachboilerisinspectedandpressuretestedforqualityassurance.
Thismanualisdesignedtoprovideallofthebasicinformationneededforasafeandproper
installation.However,therearemanyskillsneededthatcannotbelearnedbyreadingthismanual.
HarmanStoveCompanyrecommendsthattheinstallationbeperformedbyaplumbingandheating
expert.
TheHarmanTridentBoilersaredesignedtooperatesafe,easyandautomatically.Youmay
however,needtolearnafewbasicskillstomaintainare.Especiallyifthisisyourrstventureinto
solidfuelburning.Ifyouhaveanyproblems,re-readtheseinstructions.Ifyoucannotresolvethe
issue(s),ContactyourHarmanStovedealer.
TABLE OF CONTENTS
PackingList
Installation
Aquastat
Wiring
Venting
Plumbing
Operating Instructions
Starting a Wood Fire
Starting a Coal Fire
Loading Fuel
ShakingAshes
Safety Tips
Maintenance
Specications
Warranty
4
5
6
7
7
8
10
10
11
11
11
12
13
13
14
4
PackingList
TheFollowingitemsaresuppliedwithyourHarmanTrident
Boiler:
PleasenotifyyourHarmanDealerifyouaremissinganyitems.
--ShakerHandle
--JohnsonControlsAquastat-(3)pieces;A350Controllerw/Sensorwire
S350 Stage Module
  Y350PowerSupply
--ImmersionWell
--DinRailand(2)EndClamps
--TerminalBox
--TerminalBlockand(2)#8-32nuts
--Pressure Relief Valve (30 psi.)
--Temperature/PressureGauge
--AutomaticDraftControlAssembly
--(1pc.)FlexConduitw/(2)90°Fittingsw/nuts,and(3)ChaseNipplesw/nuts
--(2)ManualDraftControlKnobAssembly
--(3) Brass Coil Spring Handle
--Ash Pan
--WarrantyRegistrationForm
Notice:
The Aquastat controls supplied with
the Trident Boiler are designed only
to maintain water temperature within
the boiler. The actual heating sys-
tem is controlled separately by your
thermostat(s) opening zone valves or
energizing circulation pump(s).
Do not attach a thermostat to the sup-
plied controls.
5
Installation
Getting Started
Thesheetmetalsidesandtopareeasily
removedtoreducethechanceofdentsand/or
scratchesinthenish.Simplyliftthetopoff,and
thatwillallowthesidestobepulledawayandup,
forremoval.Tore-install,slidethechannel,atthe
bottomofeachsidepiece,overthelipatthebot-
tomoftheboiler,andholddownwardwhilemov-
ing the side panel into place. Then slide the top
downoverthesides.
NOTE:Thesheetmetaltopholdsthesidesin
place,thus,noboltsorscrewsareneeded.
Caution: Boiler should not Be
installed Closer than 36 inChes
(915 mm) to any ComBustiBle ma-
terial
Locating Boiler
Placetheboilerasclosetothechimneyas
possible,whilestillmaintainingtheabovemen-
tionedclearances.Bolttheshakerhandleonto
theblockonthesideoftheboiler,usingthe(2)
5/16X3/4in.boltsandlock-washers.
Assembly
InstalltheTemperature/PressureGauge
intothepipestubinthecenteroftheroundplate
onthefrontoftheboiler(FIG.1)
InstalltheA350sensorwireallthewayinto
theimmersionwellandscrewthewellintooneof
thetopholesonthefaceoftheboiler.
Turnthepressurereliefvalveintothestub
ontopoftheboiler,nexttothesupplyoutlett-
ting.
NOTE: Use teon tape to seal the threads
on all ttings. Any unused ttings must be
plugged.
Boltthetwomanualdraftcontrols
through the holes in the top load door. (FIG.2)
Thedraftcontrolknobshouldspinfreelyand
opentoadistanceofapproximately3/8in.from
thedoorsurface,whilebeingabletocloseagainst
the door surface.
FIG.2
3/8 to 1/2 in.
Immersion Well
Temp/Pressure Gauge
Optional Electric
Back-up Elements
Automatic Draft Control
Pressure Relief Valve
FIG.1
Johnson Controls
Aquastat and
Terminal Block
Shaker Handle
Domestic Hot Water
Coil Option
6
BolttheAutomaticDraftControlthrough
the1/2in.holeinthecenterofthebottomdoor.
BesuretoholdtheDraftControlstraightwhile
tightening.Feedthetwowiresfromthedraftmo-
torthroughtheexibleconduitanda90˚fitting.
Securethefittingtothedraftmotorandthatend
oftheconduitatthistime.Checktheflapperdoor
ontheAutomaticDraftControlassuringthatit
movesfreely.
Installthe(3)brasscoilspringhandles
ontothedoorlatchesandtheshakerhandle.Start
thespringhandleontotheshaftandtwistitcoun-
ter-clockwisewhilepushing.
Aquastat Installation
(See optional items, page 7) Lay the din rail
onaatsurface,withtheatsidedown.Secure
oneendclamp,ontheleftside.SlidetheA350
controllerontotherailfromrighttoleftuntilitis
againsttheendclamp.SlidetheY350ontothe
rail and guide the plug-in connector, joining it to
the A350. Next, install the S350, again, guiding
the plug-in connector carefully. Install the other
endclamptotherightsideofthedinrail.Remove
thecoversfromallthreecontrolsbyloosening
fourscrewseach.Installtheterminalboxtothe
controlsusing(3)chasenipplesandlocknuts,
suppliedwiththekit.Usingthefourholesinthe
terminalbox,mounttheterminalboxandcontrols
totheboilersheetmetalsideasshowninFig.1.
Using(2)#8-32nuts,installtheterminalblock
ontothestudslocatedinsidetheterminalbox.
Wiring Diagram
Installation
FIG.3
7
Wiring and Electrical
Followingthewiringdiagram,runallwires
totheirdesignatedconnections.Savethemain
powerforthelasthook-up,andleavethebreaker
intheoffposition.Thesensorwiresattachtothe
A350Controllerontheterminalsmarked“sen”
and“com”.Makesurethesensorissubmerged
fullyintothewellandsecuredwiththeset-screws.
Setting The Aquastat
InsidetheA350control,youwillseea
squarejumper,andadifferentialdial.Besurethe
jumperisinthe“Heating”position.Thedifferen-
tialdialissettodeterminehowlow,belowthe
temperaturesetpoint,youwantthewatertem-
peraturetogobeforetheAutomaticDraftControl
opens.Agoodinitialsettingforthisdialis5°.Be
surethe120Vwiresareattachedtothecommon
andthenormallyopenterminals,andreplacethe
cover.Theexternaldialissetforthewatertem-
peratureyouwishtomaintain,agoodsettingis
180°.
Inside the Y350 control, ensure that your
wiresareconnectedtothe120VACterminals,
and replace the cover.
InsidetheS350control,whichisusedas
overheatprotection,you’llseetwodials;offset,
anddifferential.Thereisalsoajumperwhich,in
thiscase,getsplacedinthe“cooling”position.
Theoffsetdialsetsthenumberofdegreesabove
theA350setpointthatyouwanttheoverheat
dumptoactivate.Agoodsetpointwouldbe20°.
Thatwouldmeanthatifthewaterreaches200°,
usingtheA350setpointof180°,theS350would
close it’s contacts and energize the overheat
dumpzone.Thedifferentialdialsetsthepointthat
theoverheatdumpwouldstop.Withthedifferen-
tialsetat15°,usingthetemperaturesabove,the
circuitwouldre-open,stoppingtheoverheatdump
atawatertemperatureof185°.The120Vwiring
isattachedonthenormallyopenandthecommon
position.Thenormallyclosedpositionisnotused.
Re-install the covers onto the three Con-
trols.
Optional Items
Thereisadomestichotwatercoilavailable
for your Trident Boiler. The coil installs in the front
oftheboiler,andallowsyourdomesticwaterto
beheatedbytheheatingsystemwater.Installthe
coilnow,byremovingtheroundplateandreplac-
ingitwiththecoilandit’sroundplate.Besureto
tightentheboltsevenly,toensureagoodseal.
Ifelectricback-upisdesired,installnow.
Therewillbetwoadditionalcontrolboxestoadd
toyouraquastat,whichwillrequiretheuseof
alongerdinrail.Thetwoheatingelementswill
installintothefrontoftheboilerasshowninFig.1
FIG.4
Venting
TheHarmanTridentBoilermustbein-
stalledintoachimneyapprovedforsolidfuel
burningappliances.IntheU.S.,theboilermustbe
connectedto;(1)aprefabricatedchimneycomply-
ingwiththerequirementsforTypeHTchimneysin
theStandardforChimneys,FactoryBuilt,Resi-
dential Type and Building Heating Appliances, UL
103.Or;(2)acodeapprovedmasonrychimney
withaueliner.InCanada,withprefabricated
chimneysystemstestedandlistedtotheHigh
TemperatureChimneyStandardULCS-629,or
withacodeapprovedmasonrychimney.The
minimumrecommendedheightforanychimney
is16ft.(4.8m)abovetheuecollar.Donotre-
duceuediameter.Nominalsizeueis8X8in.
or equivalent, up to 8 X 12 in. Codes also require
thatthechimneymustextendaminimumof
Installation
8
3feet(0.9m)abovethepointatwhichtheyexit
fromtheroof,itmustalsoextend2feet(0.6m)
abovethehighestpointwithina10ft.(3m)radius.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE THAT IS SERVING ANOTHER APPLIANCE.
Limitconnectorpipeto8ft.orless,with
nomorethantwoelbows.Allhorizontalsections
shouldhave1/4in.riseperfoot.Thechimney
mustbecapableofprovidingadraftreadingofat
least.06in.ofwatercolumn.Abarometricdamper
canbeinstalledtopreventexcessiveanderratic
draft.Allconnectorpipeshouldbesecuredwith
sheetmetalscrewsateachjoint.
Installation
Plumbing
TheHarmanTridentBoilercanbeusedas
a“StandAlone”boilerorasanadd-ontoanexist-
inghotwaterheatingsystem.
Thediagramsinthismanualaremeantto
showthenecessaryequipmentandpiping.Your
systemmaylookverydifferent.However,ifcong-
uredproperly,thesameresultswillbeachieved.
Fig.6showsatypicalplumbingdiagram
fortyingintoanexistingsystem.Thismethod
provideswatercirculationbetweenthetwoboilers
withacirculatingpump.Inthissetup,thedomes-
ticwatercoilintheexistingboilerwillbeheated,
makingitunnecessarytoinstallawatercoilinthe
Trident Boiler.
Tying-intoanexistingboilermustbedone
inthereturnlinebetweenthecirculatorandthe
existingboiler.Runapipefromtheretoasmall
circulator,andthenintothe1-1/4in.ttingonthe
rearoftheTridentBoiler.Nextrunapipefromthe
1-1/4in.ttingonthetopoftheTridentBoilertoa
Teettinginthesupplylineoftheexistingboiler.
ThisTeettingmustbeinstalledbetweentheex-
istingboilerandtheFlowControlValve,asshown
inFig.6.Anairvalveshouldbeinstalledonthis
line also.
FIG.5
FIG.6
Air Valve
Notice:
The Aquastat controls supplied with
the Trident Boiler are designed only
to maintain water temperature within
the boiler. The actual heating sys-
tem is controlled separately by your
thermostat(s) opening zone valves or
energizing circulation pump(s).
Do not attach a thermostat to the sup-
plied controls.
9
Thecirculatorinstalledbetweenthetwoboilersmaybehookeduptoruncontinuouslyduring
theheatingseasonor,anadditionalS350control(notsupplied)couldbeinstalledtoturnitonandoff
automatically.Thiscontrolmustbeusedasa“closeonriseoftemperature”(jumperincoolingposi-
tion).
HarmanStoveCompanyrecommendsthat1-1/4in.pipebeusedbetweenthetwoboilers.Also
recommendedisthattherstsectionofpipeoffofthetopoftheTridentBoilerbethreadedgalvanized
orthreadedblack-steelpipe.
TheHarmanTridentBoilerissuppliedwithadualfunctionaquastat.TheA350isusedto
controltheautomaticdraftcontrolwhetheropen,toincreaseheat,orclosed,todecreaseheat.The
S350isusedasoverheatprotection.Sinceawoodorcoalreisstillproducingheatwhenthedraftis
closed,thisoverheatprotectionisrequired.YoucouldhavetheS350energizeacirculatingpumpor
azonevalveseparatefromtheheatingsystem,oritcouldbehookedupsothatitowstheheated
waterthroughoutthesystem.Eitherway,itmustbeabletoowawayfromtheboiler.
Figure7showsatypicalschematicoftheTridentboilerasa“standalone”system.Note;the
crossoverpipe(#12)isnottotallynecessarybutisrecommendedtoprovidecirculationwithinthe
boilerwhiletheheatingsystemissatised.Thiswillensureaneventemperaturewithintheboiler.The
temperingvalveshown(#10)istopreventexcessivetemperatureofthedomesticwater.
FIG.7
Installation
10
Operation
Automatic Draft Control
Theheatoutputisregulatedbytheauto-
maticdraftcontrolonthebottomdoor.Theelectric
motor(A)opensandclosestheapperdoor(B).
Openingandclosingtheapperdoorregulates
theairowintotherebox.
Themaximumairowcanbeadjusted
byturningtheadjustingbolt(C).Turncounter-
clockwiseformoreair,andclockwiseforlessair.
Adjustthisboltonlywhiletheapperdoorisinthe
closedposition.Otherwise,motordamagecould
occur.
Theidleairadjuster(D)controlsthemini-
mumamountofairthatenterstherebox.Adjust-
mentismadebyturningtheadjusterverticalfor
zeroidleair,orhorizontalformaximumidleair.
Itisbesttostartoutwithamediumsettingas
showninFigure9.
FIG.8
FIG.9
Starting a Wood Fire
Makesuretheboilerandallpipingisfull
ofwaterandthatallairhasbeenpurgedfromthe
system.
Never start a re without water in the
system. An explosion will occur.
Turnonelectricalpowertotheboiler.This
shouldcausetheautomaticdraftcontroltoopen.
Opentheashpandoortoallowfreeairmove-
ment.Withthereboxdooropen,crumbleap-
proximately8sheetsofnewspaperandplaceon
thegrates.Laysomesmallkindlingontopofthe
newspaper.Besurethiskindlingisdryandno
morethan3/4in.indiameter.Layerthekindling
inacriss-crosstypepattern,toallowmaximum
airow.Nextlaysomelargerpiecesofwoodon
topofthekindling(approximately2in.diameter).
Usingamatchorlighter,lightthepaperjustinside
thedoor.Closeandlatchthereboxdoorandal-
lowtheretoburnafewminutes.Afteraboutve
minutes,closetheashpandoorandre-openthe
reboxdooraninchortwo,toallowthesmoketo
clear.Add4or5largerlogs(about4in.diameter)
tothewellestablishedreandclosetherebox
door.Leavetheashpandooropenforaboutve
minutesonly.Nowopenthereboxdoorusingthe
samemethodasbefore,alwaysclosingtheash
pandoorbeforeopeningthereboxdoor.Now
youcanloadthereboxtothedesiredlevel.You
mayloadwoodtothetopoftherebox.Close
andlatchthedoor.Theashpandoormayagain
beopenedtospeedtheignitionprocess.
Do not leave the boiler unattended with any
door open.
Afterthewoodisburningwell,closethe
ashpandoor.Theautomaticdraftcontrolwillnow
regulatethere,basedontemperaturedemand.
Theidleairadjustermustbetunedto
wheretheredoesn’tgooutduringlongperiods
withnodemand.Experiencewilldictatethebest
settingforyourinstallation.Normally,thetwo
manualdraftcontrolsonthereboxdoorarekept
closedwhileburningwood.
11
Operation
Starting a Coal Fire
Makesuretheboilerandallpipingisfull
ofwaterandthatallairhasbeenpurgedfromthe
system.
Never start a re without water in the
system. An explosion will occur.
Turnonelectricalpowertotheboiler.This
shouldcausetheautomaticdraftcontroltoopen.
Opentheashpandoortoallowfreeairmove-
ment.Usethesameprocedureasstartingawood
reexcept,donotloadthelargerdiameterwood
Usewoodabout2in.diametermaximum.This
sizewillformaveryhotcharcoalbedinlesstime.
Again,theashpandoormaybeopenedperiodi-
cally to speed the ignition process.
DO NOT LEAVE THE BOILER UNATTENDED
WITH ANY DOOR OPEN.
Whenyouhaveaccumulatedasubstantial
charcoalbed,startaddingathinlayerofcoal.Pea
orNutsizedcoalisbetterforstartingthanStove
coal.
Whentherstlayerisburningwithsome
blueame,continuetoaddthinlayersofcoaluntil
thereisasolidbedofburningcoal.Leteachlayer
burnablueamebeforeaddinganotherlayer.Ad-
ditionalcoalcanbelayeredinuntilthebedisap-
proximately10inchesdeep.Bynow,youshould
havetheashpandoorclosed,andtheautomatic
draftcontrolwillcontinuetoregulatethere.
Theidleairadjustermayneedtobesetfor
slightlylessairforcoalthanwood.Hereagain,
experiencewilldictatethebestsetting.Themaxi-
mumairboltcanbeturnedalltheway“counter-
clockwise”toallowforaquickerrecovery.Never
adjustthisboltwiththeapperopen.
Thetwomanualdraftcontrols,onthe
reboxdoor,areusedtoallowsecondaryairto
passovertherewhenburningcoal.Thishelps
toburnthegassesthatareemittedfromthecoal
as it is heated. Your setting for these draft controls
shouldbebetween1/2and1completeturnfrom
closed.Adjustbothcontrolsequally.
Loading
Coalshouldneverbeaddedunlessthere
isareasonablyhotre.Thecoalbedshouldbe
brightandvigorous.Ifyouhaveanactivecoal
bed,fullloadscanbeaddedatanytime.Ifnot,
addnewcoalinlayers,asdescribedinstartinga
coalre.
Shaking the Grates
Shakingshouldbedoneonlywhenthere
isawell-establishedre.Thefrequencyofshak-
ingwilldependonthedegreeofburning.Twice
adayshakingisrecommended.Thebestresults
areachievedwithshort,choppystrokesasop-
posedtolong,evenstrokes.Fullrockingofthe
gratesmayallowburningcoaltofallintotheash
pan.Theamountofshakingiscritical,toomuch
candisrupttherebed,andtoolittlewillrestrict
air-ow.Theproperamountofshakingisnormally
achievedwhenhotredcoalsrststarttodrop
through the grates into the ash pan.
Everyeffortshouldbemadetonotleta
coalreburndowntoolow.Thiswillcausethe
reloadingprocesstobemuchlonger,withareal
goodchanceoflosingtherealtogether.
Donotshakeorstirwithalowre.Open
theashpandoortogetmaximumairowinginto
therebox.Onceburningisrestored,closethe
ashpandoorandaddalayerofcoaltothere
bed.FollowtheinstructionsunderStartingaCoal
Fire.Whenthenewcoalisthoroughlyignited,and
thereisasubstantialbedofhotcoals,thegrates
maythenbeshaken.
Ashes and Ash Removal
Ashesshouldneverbeallowedtoaccu-
mulateabovethetopoftheashpan.Ashesin
contactwiththebottomofthegratesactasinsu-
lation,whichintensiestheheatonthegratesand
causesthemtosagorwarp.Also,toomuchash
accumulationwillrestrictair-owwhichwillmake
remaintenancemoredifcult.Placeashesin
asealedmetalcontainer,outside,untiltheyare
cooledenoughfornaldisposal.Coalproduces
considerablymoreashthanwood,sotheintervals
betweenemptyingaremuchshorter.
12
Safety Tips
Whenopeningthereboxdoor,itshould
becracked,slightlyopen,forafewseconds
toallowairintoburnanygaseswhichmaybe
present.Thiswillalsoallowsmoketobedrawn
awayfromthedoor.Whenevertheashpandoor
isopen,itshouldbeclosedbeforeopeningthe
reboxdoor.
Thereboxshouldneverbelledwith
excessivecoaltowheretheueexitisblockedor
impededinanyway.
Burning coal produces Carbon Monoxide. If
the ue exit is blocked, the Carbon Monoxide
can be forced out of the boiler, into the room,
with possible FATAL consequences.
With the exception of start-up or freshening
ofthere,orperformingashremoval,theashpan
doorshouldbekeptclosed.
NeverinstallaHarmanTridentBoilerintoa
chimneywithahistoryofdown-drafts.
Keep Children Away-- May Cause Seri-
ous Burns.
CAUTION: All surfaces of the boiler are
hot. Do not touch. Keep children away.
Serious burns will result if touched.
This is a heat producing appliance.
DANGER: Fire Hazard, Do not use
chemicals or ammable liquids to start
or “freshen-up” a re. Severe burns or
a house re may result. Do not burn
Garbage, Gasoline, Thinners, Oil, Kero-
sene Etc. An explosion, a house re or
serious personal injury could result.
Keep all such liquids well away from
this boiler.
Duringtherstfewhoursofburning,ablue
smokemaybeobservedrisingfromtheboiler.
This is the paint going through the curing process.
Itisadvisabletoincreasetheamountoffresh
airintheroomduringthisbreakinperiod.This
canbeachievedbyopeningdoorsandwindows.
Don’tbealarmed,thisisnormalandwillonlylast
ashortwhile.
Chimney Problems
Not Enough Draft-Chimneyistoolow.
Thegeneralruleforchimneysis16feettall,and
twofeethigherthananythingtenfeetaroundit.
Airmaybeleakinginaroundaloosettingclean-
out door.
Toomanyelbowsinconnectorpipe,orseamsand
joints of connector pipe are not secured properly.
Improperlysizedchimneyorstovepipe.
Chimneymaybeblockedwithcreosoteorbird
nestsorsimilarobstructions.
Crackedordefectivechimneyueorliner.
Down Drafts- Trees or other topographi-
calbarriersmayimpedeonchimneyperformance
causingaircurrentstobepusheddownwardinto
theue.Thiscanalsobecausedbyneighboring
buildingsorotherchimneys.
Creosote and condensation- If creo-
soteorcondensationrunsoutofthechimneyor
stovepipe,checkthefollowing;Chimneycapor
linermaybedefective,Boilermaybepositioned
toofarawayfromthechimneywhichwouldnot
allowthechimneytowarm,Woodbeingburned
maybegreenorwet,Boilermaybeover-sizedfor
theresidencecausingittobeburnedonlowtoo
often.
Excessive Draft-Thiscanbecontrolled
withabarometricdamperinthestovepipe.
Operation
13
Maintenance
Maintenance
Thespiralchamberisbasicallyself-cleaning.However,ifthereisadraftproblemandyouhave
beenburningwoodforalongtimewithlittledemand,thespiralchamberwillneedtobecleaned.To
cleanthespiralchamber,removethestovepipeandscrapeanycreosoteordebrisfromthetopand
frontofthechamber.Therearofthechambershouldnothavemuchaccumulation.Ifitdoes,cleanit
out.
NOTE:1/4”to1/2”ofcreosoteinthespiralchamberisnormal.
Thepipesinsidethereboxwillaccumulatecreosoteifthedemandforheatistoolow,when
burningwood.1/8”to1/4”ofcreosoteisnormalonthepipesandreboxwalls.Ifmorecreosotehas
accumulated,itshouldbescrapedoffofthesesurfaces.
NOTE:Creosoteinthereboxcanbeburnedoffbyburningcoalforafewdays.
Therebricksmaybecomecrackedduringthecourseofnormaloperation.Acrackedbrick
thatisstillinplace,isstilldoingitsjob,andneednotbereplacedimmediately.Ifabrickisbroken,and
hasfallenoutofplace,itshouldbereplacedbeforeanyfurtherburningoccurs.Therebricksusedin
theTridentBoilerareavailableforreplacementfromyourHarmandealer.
Gasketsonthedoorsaretheretoregulateairtotherebox.Ifagasketisfailing,you’llnotice
difcultyincontrollingthere.Inspectthegasketsregularly,andreplacewithHarmansuppliedmate-
rial only.
Specications SF-160 SF-260 SF-360
Heating Capacity (Square Feet) 2200 Max. 3200 Max. 4500 Max.
ApproximateBTUperhour(woodorcoal) 90,000 130,000 180,000
AMP Rating 40 40 40
Water Capacity (US Gallon) 25 32 42
Weight 640Lbs 780Lbs 925Lbs
Hydro-Pressure Tested Yes Yes Yes
FireboxDimensions(inches) 16Wx22Lx19H 18W x 26L x 20H 18W x 30L x 25H
RecommendedLogLength(inches) 19 23 27
Door Opening Size (inches) 11 x 13 13 x 13 13 x 13
OverallDimensions(inches) 23W x 23.5L x 45H 26W x 27.5L x 45.5H 26W x 31.5L x 51.5H
FlueSize(diameter) 6 inch 7 inch 7 inch
FlueHeight(topofue) 37.5 inches 38.75 inches 44 inches
NumberOfGrates(10Lbs.Each) 4 5 6
Type Of Fuel Coal / Wood Coal / Wood Coal / Wood
Water Inlet and Outlet Size 1.25 NPT 1.25 NPT 1.25 NPT
AutomaticDraftControl Yes Yes Yes
Aquastat Yes Yes Yes
Temperature/PressureGauge Yes Yes Yes
ASME Pressure Relief Valve Yes Yes Yes
Ash Pan With Handle Yes Yes Yes
DomesticHotWaterCoil(optional) 4 GPM 4 GPM 4 GPM
ApproximateBTUperhour(electricoption) 30,000 30,000 30,000
KilowattRating(electricoption) 9 9 9
14
Warranty
1 Year Limited Warranty (commercial)
5 Year Limited Warranty (residential)
Warrantyisnottransferable.HarmanStoveCompanywarrantsitsproductstobefreefromdefectsin
materialandworkmanship,innormaluseandservice,forve(5)yearsfromthedateofpurchase.
Ifdefectiveinmaterialorworkmanship,andifremovedbytheownerwithin60monthsofthedateof
installation,HarmanStoveCompanywill,atitsoption,repairorreplacetheproductasdescribedbelow.
ThewarrantyaboveconstitutestheentirewarrantywithrespecttoHarmanStoveCompanyproduct.
HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING ANY
WARRANTY OF MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No
employee,agent,dealer,orotherpersonisauthorizedtogiveanywarrantyonbehalfofHarmanStoveCom-
pany.Thiswarrantydoesnotapplyiftheproducthasbeenalteredinanywayafterleavingthefactory.Harman
StoveCompanyassumesnoliabilityfor“resultantdamagesofanykind”arisingfromtheuseofitsproducts.In
addition,themanufacturershallbeheldfreeandharmlessfromliabilityfordamagetopropertyrelatedtothe
operation,properorimproper,oftheproduct.THEREARENOOTHERWARRANTIESWHICHEXTENDBE-
YOND THE DESCRIPTION ON THE FACE HEREOF.
THESEWARRANTIESAPPLYonlyifthedeviceisinstalledandoperatedasrecommendedinthemanu-
al.
THESEWARRANTIESWILLNOTAPPLYifdamageiscausedbyabuse,accident,improperinstallation,
negligence,orusebeyondtheratedcapacity.
LABORRESPONSIBILITY-Infurnishingreplacementparts,HarmanStoveCompanyassumesnore-
sponsibilityforlaborexpensesforservice,removal,orre-installation.
MAKINGACLAIM-Anyclaimunderthiswarrantyshallbemadetothedealerfromwhomthisappliance
waspurchased.Then,contactismadewiththemanufacturer,givingthemodel,serialnumber,dateofpur-
chase,dealer’snameandaddress,plusasimpleexplanationofthenatureofthedefect.
SHIPPINGCOSTS-Thetransportationchargesareasfollows:
(1)CustomerPre-paysfreighttoHarmanStoveCompany
(2)HarmanStoveCompanyPre-payschargesfortherepairedorreplacementunit.
NOTE:Priorapproval,byphoneorinwriting,shallbemadebeforeshippingtheappliancetomanufacturer.
THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS-REPAIR AND/OR REPLACEMENT AT HARMAN
OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THERE-
WITH.
WARRANTYEXCLUSIONS:(1)Labor(2)Firebricks(3)DoorPacking(4)Paint(5)ActsofGod
PLEASE READ THE LITTERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY
DEVICES.THESEDEVICESARE“WARRANTEDBYTHEMANUFACTURER”NOTBYHARMANSTOVE
COMPANY. FURTHERMORE, THEESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORD-
ING TO THE RECOMMENDATIONS OF THE MANUFACTURER.
Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sothe
abovelimitationorexclusionmaynotapplyinyourstate.
Thiswarrantygivesyouspeciclegalrights.Youmayalsohaveotherrights,whichvaryfromstateto
state,whichmaybeenforceableinacourtoflaw.
REMEDIES-Theremediessetforthhereinareexclusive,andtheliabilityofsellerwithrespecttoany
contractofsaleorthingsdoneinconnectiontherewith,whetherincontract,intort,underanywarranty,oroth-
erwise,shallnot,exceptashereinexpresslyprovided,exceedthepriceoftheequipmentorpartofwhichsuch
liabilityisbased.
CLARIFY-Theaboverepresentsthecompletewarantygiveninconnectionwithboilersmanufacturedby
HarmanStoveCompany.Noothercommitments,verbalorotherwise,shallapply,exceptbyawrittenadden-
dumtothiswarranty.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Harman Stove Company SF360 User manual

Category
Wood stove
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI