TRANQUILITYWOODSTOVE
INSTALLATION&OPERATIONMANUAL
17VL,50SVL17&50TVL17

CAUTION
Pleasereadthisentiremanualbeforeinstallationanduseofthiswoodfuel
burningappliance.Keepchildren,furniture,fixturesandallcombustiblesaway
fromanyheatingappliance.
SAFETYNOTICE
Failuretofollowtheseinstructionscanresultinpropertydamage,bodilyinjury
orevendeath.Foryoursafetyandprotection,followtheinstallation
instructionsoutlinedinthismanual.Contactyourlocalbuildingorfireofficials
aboutrestrictionsandinstallationinspectionrequirements(includingpermits)
inyourarea.
SAVETHESEINSTRUCTIO NS
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe
,
VA24574
REV. 9/2010
Page | 2
Retainforyourfiles
ModelNumber________________________
DateofPurchase_______________________
DateofManufacture____________________
SerialNumber_________________________
*Thisinformationcanbefoundonthesafetytagattachedtotherearoftheunit.
Havethisinformationonhandifyouphonethefactoryoryour dealerregardingthis
product.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DO
NOTRETURNITTOTHEDEALER.CONTACTTECHNICAL
SUPPORT@18002456489
MobileHomeUse:
Thisfreestandingwoodunitisapprovedformobilehomeor
doublewideinstallationwiththeoutsidecombustionairhook
up.Seethe“Installation”sectionofthismanualfordetails
pertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufactured
HomeandSafet
y
Standard
(
HUD
)
,CFR3280,Part24.
CAUTION
Keepchildrenaway.
Supervisechildreninthesameroomasthisappliance.
Alertchildrenandadultstothehazardsofhightemperatures.
DoNOToperatewithprotectivebarriersopenorremoved.
Hotwhileinoperation!Keepclothing,furniture,draperiesandother
combustiblesaway.Contactmaycause
skinburns!
InstallationMUSTcomplywithlocal,regional,stateandnationalcodesand
regulations.
Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionabout
restrictions,installationinspection,andpermits.
Page | 3
TABLEOFCONTENTS
Introduction
Introduction.................................4
Specifications
HeatingSpecifications..................5
Dimensions...................................5
EPACompliance...........................5
Installation
InstallationOverview...................6
ClearancestoCombustibles.........7
VentingIntroduction....................8
VentingGuidelines.......................8
AdditionalVentingInformation...9
WallPassThroughs....................10
ApprovedVentingMethods
o ThroughtheWall...........11
o ThroughtheCeiling........12
o Masonry
Chimney..........13
MobileHomeInstallation..........14
OutsideAirHookUp..................14
FloorProtection.........................15
RvalueCalculations...................16
Operation
BreakInFires.............................17
LightingaFire.............................17
ContinuousOperation................18
SafetyNotes...............................19
Maintenance
ImportantNotes.........................20
InspectingGaskets.....................21
GlassandGasketReplacement..22
TroubleshootingGuide
Troubleshooting.........................23
OptionalAccessories
AC16Blower.............................24
IllustratedPartsDetail
PartsList.....................................24
ExplodedPartsDiagram.............25
Warranty
WarrantyDetails...................2627
WarrantyReg.Form..............2829
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAOR
ENGINEOIL.
Page | 4
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyina“DoItYourself”spirit;that’sonereasonyou
foundthisproductatyourfavorite“DoItYourself”store.
Weintentionallydesign
andbuildourstovessothatanyhomeowner
canmaintaintheirunitwithbasictools,andwe’realwaysmorethan
happytoshowyouhowtodothejobaseasilyandasinexpensivelyas
possible.However,whileremainingsimple,ourstovesaredesignedto
performextremelyefficiently,helpingdelivermore
heatfromlessfuel.
PleaselookatourvastHelpsectiononourwebsiteandcallour
TechnicalSupportDepartmentat(800)2456489ifyouneedanyhelp
withyourunit.Wearenearlyalwaysableto“walkyouthrough”any
installationissues,repairs,problemsorotherquestionsthat
youmay
have.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EVERYONEATENGLANDSSTOVEWORKS
PleaseNote
:Whileinformationobtainedfromourwebsiteand
throughourTechnicalSupportlineisalwaysfreeofcharge,therewill
beaservicechargeincurredwithany“onsite”repairsormaintenance
thatwemayarrange.
Page | 5
SPECIFICATIONS
HeatingSpecifications
MaximumHeatOutput......................................................................40,000BTU/hr
MaximumBurnTime**................................................................................6hours
ApproximateSquareFootageHeated***.....................................500‐1200sq.ft.
FireboxCapacity.......................................................................................45pounds
FlueCollar.............................................................................................6.0in.round
Dimensions
EPAandSafetyComplianceSpecifications
EPACompliance...........................................................................................Certified
ParticulateEmissions............................................................................4.3grams/hr
Efficiency*...........................................................................................................63%
TestedTo...............................................................................UL1482,ULCS62700
*‐Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,
certifiednoncatalyticwood
**‐Maximumburntimeareheavilydependentonthetypeofwoodburnedinthestove;assuch,thesenumbers
mayvary.
***‐Themaximumheatingcapacityof
thisunitcanvarygreatlybasedonclimate,constructionstyle,insulation
andamyriadofotherfactors.UsethisinformationinconjunctionwithaBTUlosscalculationforyourhometo
determineifthisunitwillbesufficientforyourneeds.
30.1875in.
20.375in.
12.5in.
31.75in.
Page | 6
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeoffactorsthat
shouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatternsTohelppreventaccidents,thestoveshouldbeplacedinalocation
whereitisoutofthewayofnormaltravel
throughthehome.
2. HeatFlowWhendecidingonalocationforthestove,considerthewayheatmoves
throughoutyourhome.Installthestovewhereyouneedtheheat;basement
installationsoftendonotallowsufficientheattoflowtotheupperfloorsandatop
floorinstallationwillnotallowanyheattoreachthefloorsbelow.Alwaysconsider
thatheatrisesandwilltakethepathofleastresistancewhileitisstillhot.
3. ExhaustLocationTheenginewhichdrivesawoodstoveisthechimneysystem,so
itisimportanttoconsiderpreciselyhowthechimneysystemwillbeintegratedinto
thestoveinstallation.Ideally,awoodstovechimneywillruncompletelyvertical
fromthefluecollaroftheunitallthewaytotheterminationpointabovetheroof
line.Keepingtheentirechimneysysteminsidetheheatedenvelopeofthehome
willensureastrong,easytoinitiatedraftinthechimney.Althoughexteriorchimney
systemsoftenfunctionproperly,theyaremorelikelytosufferfromcolddowndrafts
atstartuporprovideweakdrafttotheunit.Also,considerthecrosssectionalarea
ofthechimney;althoughexistingmasonrychimneyscanoftenbeused,alarge
externalmasonrychimneywillresultinaunitthatisdifficultorimpossibleto
operateproperly.Inthatcase,aninsulatedchimneylinerwilloftenberequiredto
supplythenecessarydraft.
4. WallConstructionLocatingthestovesothattheexhaustsystemcanpassbetween
studswillsimplifytheinstallationandeliminatetheneedtoreframeanysectionsof
thewallorceilingtoaccommodatethewallthimbleorceilingbox.
WARNING
Donotstoreorusegasolineorotherflammablevaporsandliquidsinthe
vicinityofthisoranyotherappliance.
DoNotOverfireIfanyexternalpartstartstoglow,youareoverfiring.
Reduceintakeairsupply.Overfiringwillvoidyourwarranty.
Comply
withallminimumclearancestocombustiblesasspecified.
Failuretocomplymayresultinahousefire.
Testedandapprovedforcordwoodonly.Burninganyotherfuelwill
voidyourwarranty.
Page | 7
INSTALLATION
ClearancestoCombustibles
ParallelWallInstallation
CornerInstallation
UnittoSide
Wall
Chimney
Connector
toSide
Wall
Chimney
Connector
toRear
Wall
Unitto
RearWall
Unitto
Corner
Chimney
Connector
toCorner
A B C D E F
in.(mm.) in.(mm.)in.(mm.) in.(mm.) in.(mm.) in.(mm.)
SingleWallChimney
Connector
UnprotectedSurface
12
(304.8)
19.5
(495.3)
12
(304.8)
10
(254.0)
7
(177.8)
15
(381.0)
DoubleWallChimney
Connector
UnprotectedSurface
11
(279.4)
17.5
(444.5)
10
(254.0)
8
(203.2)
6
(152.4)
14
(355.6)
A
B
C
D
E
F
Page | 8
INSTALLATION
VentingIntroduction
Thiswoodstoveoperatesona
naturaldraftsystem,inwhichthechimney
systempullsairthroughthestove.Thisunit
mustbeinstalledinaccordancewiththe
followingdetaileddescriptionsofventing
techniques;notinstallingthestovein
accordancewiththedetailslistedherecan
resultinpoorstove
performance,property
damage,bodilyinjuryordeath.Avoid
makeshiftcompromiseswheninstallingthe
ventingsystem.England’sStoveWorksis
notresponsibleforanydamageincurred
duetoapoororunsafeinstallation.
Becertainthatallaspectsofthe
ventingsystemareinstalledtotheventing
manufacturer’sinstructions,particularlythe
requiredclearancestocombustibles.Also,
becertaintouseanatticradiationshieldto
preventinsulationfromcontactinga
chimneywhichpassesthroughanattic.
Thechimneysystemisthe“engine”
whichdrivesawoodstove,soitis
imperativeforproperunitfunctionthatthe
ventingsystembeinstalledexactlyas
describedinthefollowingsection.
Ifquestionsarisepertainingtothe
safeinstallationofthestove,ourTechnical
Supportline(8002456489)isavailable.
Contactyourlocalcodeofficialtobecertain
yourinstallationmeetslocalandnational
firecodes,andifyou’reuncertainabout
howto
safelyinstallthestove,westrongly
recommendcontactingalocalNFIcertified
installertoperformtheinstallation.
VentingGuidelines
ALWAYSinstallventpipeinstrict
adherencetotheinstructionsand
clearancesincludedwithyour
ventingsystem.
DONOTconnectthiswoodstoveto
achimneyfluewhichalsoserves
anotherappliance.
DONOTinstallafluepipedamper
oranyotherrestrictivedeviceinthe
exhaustventingsystemofthisunit.
USEanapprovedwallthimblewhen
passingthroughawallandaceiling
support/firestopwhenpassing
throughaceiling.
INSTALLthreesheetmetalscrewsat
everychimneyconnectorjoint.
AVOIDexcessivehorizontalrunsand
elbows,asbothwillreducethedraft
oftheventingsystemandwillresult
inpoorstoveperformance.
INSPECTyourventingsystemoften,
tobecertainitisclearofcreosote,
flyashandotherrestrictions.
CLEANtheventingsystemas
detailedinthemaintenancesection
ofthismanual.
ADHEREtothe1032
ruleregarding
chimneyterminations.
INSTALLsinglewallchimney
connectorwiththemaleenddown
topreventcreosoteleakage.Follow
doublewallchimneyconnector
manufacturer’sinstructions
regardingproperpipeinstallation.
WARNING:VentingsystemsurfacesgetHOT,andcancauseburnsif
touched.Noncombustibleshieldingorguardsmayberequired.
Page | 9
INSTALLATION
AdditionalVentingInformation
Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassembling
yourventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimble
fromanother).
Werequireaminimumchimneyheightof15.0ft.Chimneysystemsshorterthanthis
maynotcreatetheamountofdraftwhichisrequiredtooperatethiswoodburningunit.
Donotusemakeshiftcompromiseswheninstallingtheventingsystem;haveexisting
chimneysystemsinspectedbeforeuseandbecertainallnewchimneysystemsare
installedtothemanufacturer’sspecificationsandwithonlyULlistedcomponents.
PrefabricatedventingsystemsusedforthisstovemustbelistedtoULCS629(Canada)
andUL103HT(US).
Neverinstalladraftinduceroranyothersystemwhichincreasesthenaturaldraftofthe
chimney;similarly,donotinstallabarometricorstovepipedamperwiththisunit.
Neverusesinglewallordoublechimneyconnectorasachimneysystem;neverpass
eithertypeofchimneyconnectorthroughacombustiblewallwithoutcarefullyfollowing
themanufacturer’sinstructionsandthoselistedinthefollowingpageonWallPass
Throughs.NEVERpasschimneyconnectorthroughanattic,floor,closetorroof.
Onlyuse24gaugeMSGblacksinglewallchimneyconnectororULListeddoublewall
chimneyconnector.
SingleWallChimneyConnectorInstallation
WARNING
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
HOT!Donottouch!Severeburnsorclothingignitionmayresult.
Glassandothersurfacesarehotduringoperation.
FlueGasDirection
Crimpedormaleendof
singlewallchimney
connectormustfacedown.
Fasteneachsinglewall
chimneyconnectorjoint
withthreesheetmetal
screws.
Themaleendofsinglewall
chimneyconnectoris
installedfacingdownsothat
anyliquidcreosoteinthe
fluewillrunintotheunit
insteadofontotheoutside
ofthepipe(thenaturaldraft
inthechimneysystemwill
preventsmokeleakageat
thejoints).
Page | 10
INSTALLATION
WallPassThroughs
InCanada,theinstallationmustconformtoCAN/CSAB365whenpassingthroughcombustibleconstruction.
Page | 11
INSTALLATION
Approved Venting Method 1
: Through the Wall Factory Built Chimney
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
StormCollar
TerminationCap
RoofFlashing
ClassAChimneySystem
The1032Rule:Thechimneysystem
mustterminate3.0ft.abovethepoint
whereitscenterlinepassesthroughthe
roofANDthechimneymustterminate
2.0ft.aboveanypartofthedwelling
withina10ft.radiusofthechimney.
3.0ft.
2.0ft.
10ft.
TeeandTeeSupport
WallThimble
18.0in.
PrefabricatedchimneysystemsmustconformtoUL103HT(2100°F)fortheU.S.andULCS629(650°C)for
Canada.
Thiswoodburningunitisonly
listedforinstallationwith6.0”diameterchimneyconnectorandchimneysystems.
Installingthisunitonprefabricatedchimneyslargerth an6.0”diameterwillresultindecreaseddraftandthe
potentialforpoorunitperformance.
Followallventingsystemmanufacturer’sinstallationrequirementsandrequiredclearances.
Usethreesheetmetalscrews
ateachsinglewallchimneyconnectorjoint(checkmanufacturer’s
recommendationswhendoublewallchimneyconnectorisused).
Drillthreeholesinthefluecollaroftheunitandattachthechimneyconnectortotheunitusingsheetmetal
screws.
Properlyattachtheprefabricatedchimneysystemtothehomeinstrictaccordancewiththeprefabricated
chimneysystemmanufacturer’sinstructions.
Avoidnumerouselbowsandexcessivehorizontalrunsasbothwillleadtopoordraftandincreasedcreosote
accumulation.Horizontalrunsofchimneyconnectormustneverexceed4.0ft.andtheoveralllengthofthe
chimneyconnectormustnotexceed8.0ft.
Specialadaptersandslipconnectorsareavailabletoeliminatetheneedtocutsinglewallchimney connector.
Doublewallchimneyconnectormustbeusedwiththeseslipconnectors,asitcannotbetrimmedtolength.
ChimneyConnector
(SingleorDoubleWall)
Page | 12
INSTALLATION
Approved Venting Method 2
: Through the Ceiling
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
CeilingSupportBox
StormCollar
TerminationCap
RoofFlashing
ClassAChimneySystem
ChimneyConnector
(SingleorDoubleWall)
3.0ft.
2.0ft.
10ft.
The1032Rule:Thechimneysystem
mustterminate3.0ft.abovethepoint
whereitscenterlinepassesthroughthe
roofANDthechimneymustterminate
2.0ft.aboveanypartofthedwelling
withina10ft.radiusofthechimney.
PrefabricatedchimneysystemsmustconformtoUL103HT(2100°F)fortheU.S.andULCS629(650°C)for
Canada.
Thiswoodburningunitisonly
listedforinstallationwith6.0”diameterchimneyconnectorandchimneysystems.
Installingthisunitonprefabricatedchimneyslargerth an6.0”diameterwillresultindecreaseddraftandthe
potentialforpoorunitperformance.
Followallventingsystemmanufacturer’sinstallationrequirementsandrequiredclearances.
Usethreesheetmetalscrews
ateachsinglewallchimneyconnectorjoint(checkmanufacturer’s
recommendationswhendoublewallchimneyconnectorisused).
Drillthreeholesinthefluecollaroftheunitandattachthechimneyconnectortotheunitusingsheetmetal
screws.
Properlyattachtheprefabricatedchimneysystemtothehomein
strictaccordancewiththeprefabricated
chimneysystemmanufacturer’sinstructions.
Theoveralllengthofthechimneyconnectormustnotexceed8.0ft.Inthecaseofcathedralceilings,the
prefabricatedchimneysystemshouldextendto8.0ft.fromthetopoftheunit.
Specialadaptersandslipconnectorsare
availabletoeliminatetheneedtocutsinglewallchimneyconnector.
Doublewallchimneyconnectormustbeusedwiththeseslipconnectors,asitcannotbetrimmedtolength.
Page | 13
INSTALLATION
Approved Venting Method 3
: Internal or External Masonry Chimney System
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
ChimneyConnector
(SingleorDoubleWall)
3.0ft.
2.0ft.
10ft.
The1032Rule:Thechimneysystem
mustterminate3.0ft.abovethepoint
whereitscenterlinepassesthroughthe
roofANDthechimneymustterminate
2.0ft.aboveanypartofthedwelling
withina10ft.radiusofthechimney.
18.0in.
MasonryThimblewith
properclearanceto
combustibles
Chimneylinercrosssectional
area(LengthxWidth)mustbe
nolargerthantwicethecross
sectionalareaofthefluecollar
(2x28.27in
2
=56.55in
2
).If
chimneylinerislargerthan
56.55in
2
,reliningwitha5.5”
or6.0”linerisrequired
AshCleanoutsmust
haveanairtightsealto
preventweakdraft.
Followtheruleslistedaboveconcerningmaximumpermissiblefluelinersize;installingthisunitonmasonry
chimneysexceeding56.55
in
2
incrosssectionalareawillresultindecreaseddraftandthepotentialforpoorunit
performance.
Usethreesheetmetalscrewsateachsinglewallchimneyconnectorjoint(checkmanufacturer’s
recommendationswhendoublewallchimneyconnectorisused).
Drillthreeholesinthefluecollaroftheunit
andattachthechimneyconnectortotheunitusingsheetmetal
screws.
Avoidnumerouselbowsandexcessivehorizontalrunsasbothwillleadtopoordraftandincreasedcreosote
accumulation.Horizontalrunsofchimneyconnectormustneverexceed4.0ft.andtheoveralllengthofthe
chimneyconnectormustnot
exceed8.0ft.
Atightsealatthethimbleiscrucialforproperunitperformanceandtocreateasafeinstallation.Usetheproper
adapterdesignedforconnectingsingleordoublewallchimneyconnectortoamasonrythimble.
Haveexistingmasonrychimneysinspectedforsafetyandproperclearances
tocombustiblesbeforeputtingthem
intoservice;aqualifiedchimneysweepcanperformthisinspection.
Externalmasonrychimneysoftensuffer colddowndraftsandpoordraftperformanceevenwhentheymeetthe
crosssectionalarearules.Inthiscase,a6.0”insulatedlinermaybenecessary.
Page | 14
INSTALLATION
MobileHomeInstallation
ThewoodstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandtheholes
providedinthebottomoftheunitforthis
purpose.
Thewoodstovemustbeconnectedtothe
chimneysystemwithdoublewallchimney
connectorwhichisULlisted
foruseinmobile
andmanufacturedhomes.
Carefullyfollowallclearanceslistedinthe
appropriatesectionofthismanualANDfollow
theventingmanufacturer’sminimum
clearancerequirements.Similarly,becertain
theventingsystemusedisapprovedfor
mobilehomeuse.
Installationmustbeinaccordancewith
ManufacturersHome&
SafetyStandard(HUD)
CFR3280,Part24aswellasanyapplicablelocalcodes.
OutsideCombustionAir
Theuseofoutsidecombustionairismandatorywheninstallingthiswoodstoveinamobileor
manufacturedhome.
Theoutsideairconnectionpipeprotrudesfromthebottomcenterofthestove;akitisavailable
fromEngland’sStoveWorks,Inc.designedforconnectingthisun ittooutside
combustionair.[Part
No.ACOAK5]
IfitisnotfeasibletousetheACOAK5outsideairhookupkitinyourstoveinstallation,other
materialsmaybeused,providedthefollowing rulesarefollowed:
o Thepipeusedforoutsideairhookupmustbemetal,witha minimumthickness
of.0209in.
(25gaugemildsteel)orgreaterandaninsidediameterofapproximately4 .25in.
o Keeppiperunsshortanduseamechanicalfastenerateachpipejoint.
o Ascreenorotherprotectiondevicemustbefittedovertheoutsideairterminationpointto
preventrain,debrisand
nuisanceanimalsfromenteringthepipingsystem.Inspectthe
outsidecombustionairinletforblockanddebrismonthly.
WARNING
DONOTINSTALLINASLEEPINGROOM.
CAUTION
THESTRUCTURALINTEGRITYOFTHE
MANUFACTUREDHOMEFLOOR,WALLAND
CEILING/ROOFMUSTBEMAINTAINED.
Caution
NEVERdrawoutsidecombustionairfrom:
Wall,floororceilingcavityor
enclosedspacesuchasanattic,garageorcrawl
space.
JoistShield
/
Firesto
p
MobileHomeApprovedDouble
WallChimne
y
Connector
RoofFlashingandStormCollar
ChimneyCap/SparkArrestor
Usesiliconetocreateavapor
barrierwherethechimneypasses
throughtoexterior.
ClassAChimneySystem
Page | 15
FLOORPROTECTION
Thiswoodstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledona
combustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynoncom bustible(i.e.a
concretefloorinabasement),nofloorprotectionisneeded(althoughadecorative
floorprotector
canstillbeusedforaestheticreasons).
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheating
andcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints
locatednearthestove.
Thefloor
protectorshouldbeULappro vedorequivalentandmustbenoncombustiblewithanR
valueof0.5.Sincethemajorityoftheheatfromthisunitisradiant, thefloorprotectornotonly
servestokeepashesandsparksfromlandingoncombustibleflooringneartheunitbutalso
protects
thecombustiblefloorfromtheheatoftheunit.AhearthrugisNOTanapproved
substituteforaproperhearthpad.
FortheUS:Thefloorprotectormustextendatleast16in.fromthefrontofthefuelopening,8in.
fromthesidesofthedooropening
and8in.fromtherearoftheunit.
ForCanada:Thefloorprotectormustextendatleast450.0mmfromthefrontofthefuelopening,
200.0mmfromthesidesofthedooropeningand200.0mmfromtherearoftheunit.
Thenoncombustiblefloorprotectormustextend2in.(50.8mm.)oneithersideofanyhorizontal
ventingrunsandextenddirectlyunderneathanyverticalventingpipe.
PleaseseethefollowingpageforinstructionsoncalculatingRvalues,tobecertainthatthe
plannedfloorprotectionisadequatefor
thisstove.
US:8.0in.
CANADA:200.0mm.
US:8.0in.
CANADA:200.0mm.
US:8.0in.
CANADA:200.0mm.
US:16.0in.
CANADA:450.0mm.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTERFLUID,
ORSIMILARLIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALLSUCH
LIQUIDSWELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVERAPPLYFIRE
STARTERTOANYHOTSURFACEOREMBERSINTHESTOVE.
Page | 16
FLOORPROTECTION
RValueCalculation
Aneasymeansofdeterminingifaproposedalternatefloorprotectormeetsrequirementsis
tofollowthisprocedure:
1) ConvertspecificationtoRvalue:
i Rvalueisgivennoconversionisneeded
ii kfactorisgivenwitharequiredthickness(T)ininches:R=1/kxT
iii Cfactorisgiven:R=1/C
2) DeterminetheRvalueoftheproposedalternatefloorprotector:
i Usethecorrectformulagiveninstep1(above)toconvertvaluesnotexpressedas
“R.”
ii Formultiplelayers,addRvaluesofeachlayertodetermineoverallRvalue.
3) If the overall Rvalue of the system is greater than the Rvalue of the specified floor
protector,thealternateisacceptable.
EXAMPLE:
The specified floor protector should be ¾” thick material with a kfactor of 0.84.The
proposed alternate is 4” brick with a Cfactor of 1.25 over 1/8” mineral board with a k
factorof0.29.
Step(a): UseformulaabovetoconvertspecificationtoRvalue.
R=1/kxT=1/0.84x.75=0.893
Step(b): CalculateRofproposedsystem.
4”brickofC=1.25,thereforeRbrick=1/C=1/1.25=0.80
1/8”mineralboardofk=0.29,thereforeRmin.bd.=1/0.29x0.125=0.431
TotalR=R
brick
+R
mineralboard
=0.8+0.431=1.231
Step(c): CompareproposedsystemofRof1.231tospecifiedRof0.893.Sinceproposed
systemRisgreaterthanrequired,thesystemisacceptable.
Definitions:
Thermalconductance =C =_____Btu____ =____W____
(hr)(ft
2
)(degF) (m
2
)(degK)
Thermalconductivity =k =__(Btu)(inch)__ =___W____ =____Btu____
(hr)(ft
2
)(degF) (m)(degK)(hr)(ft)(degF)
Thermalresistance =R =(ft
2
)(hr)(degF) =(m
2
)(degK)
Btu W
Page | 17
OPERATION
BreakInFires
Thiswoodburningunitisconstructedofheavygaugesteelandcastironandisbuilttolasta
longtime.However,inordertoensurenoexcessivethermalstressesareinducedonthemetal
duringthefirstfire,threebreakinfiresshouldbeburned,eachoneslightly
hotterthanthelast.
Thesebreakinfireswillnotonlyhelpthestovebodyacclimatetothehightemperaturesofthe
fire,butwillalsoslowlycurethehightemperaturestovepaint,whichwillensurethehigh
qualityfinishlastsforyears.
Thisstovehasasingleaircontrol
rodwhichregulatesthewoodburnrate;whentheprimaryair
controlslideispulledallthewayoutoftheunit,thestovewillburnmoreslowlyandputout
heatoveralongertimeperiod.Conversely,whenthe aircontrolslideispushedallthewayin,
the
unitwillburnmorequicklyandputoutalargeramountofheatoverarelativelyshorter
timeperiod.Donotattempttomodifytherangeofaircontroladjustmentforanyreason.
Thefirstbreakinfireshouldbejustalargekindlingfire,gettingthestovetoabo ut
300°Fas
measuredbyamagneticthermometerontherightorleftsideofthestove,abovethedoor.
Oncethistemperaturehasbeenreached,allowthefiretodieoutwiththeaircontrolopen.The
secondandthirdbreakinfiresshouldbeabitlarger,with
somesmalldrysplitsaddedtothe
kindlingload.Thetemperaturegoalduringthesefiresisabout 350°F450°F;don’tletthefire
gethotterthanthat.
ContinuousOperation
Afterthebreakinfiresarecomplete,thisunitisreadyforcontinuousoperation.Whenburning
thestovecontinuously,donotallowashandcoalstoaccumulatehigherthan 1.0”belowthe
dooropening.Excessivecoalingisoftenaresultofburningwoodattoohighaburnrate,
and
thecoalbedshouldbeallowedtoburndownbeforereloadingthestovewithfreshwood.
Combustionairisdeliveredtothestoveattwolocations:Themajorityoftheprimary
combustionairentersthefireboxviatheairwashsystemwhichkeepstheglasscleanandfeeds
the
primarycombustionflamesonthetopsurfacesofthewood;someprimarycombustionairis
bledoffintothecoalbedviableedholesinthebottomrailoftheairwashsystem.Everyeffort
mustbetakentomaintaintheareainfrontoftheseholesfreeofash.
Whenloadingthestoveforalongtermburn,itismostusefultorakea“v”inthecenterofthe
coalbed,toallowtheprimaryairbleedholes topushairallthewaytotherearoftheunit.
Afterloadingthestovewitha
fullfireboxoffreshwood,itisimportanttooperatetheunitwith
theaircontrolinthefullopenpositiontoproperlycharthewoodloadanddriveofftheinitial
moistureinthefreshwood.Oncethewoodhasbeenproperlycharredandiscompletely
ignited,theair
controlcanthenbesettothedesiredheatoutputlevel.
Intheeventofacreosoteorsootfire(chimneyfire),closetheaircontrolonthe
stove,contactthelocalfiredepartmentandgetout!Donotthrowwateronthefire!
Contactyourlocalfireauthorityformoreinformationonhowtohandleachimney
fireanddevelopa
safeevacuationplanforyouandyourfamilyintheeventofa
chimneyfire.
Page | 18
OPERATION
England’sStoveWorks,Inc.alwaysrecommendstheuseofamagneticstovethermometer,so
thatthetemperatureoftheunitcanbemonitored.Whenusingamagneticstovethermometer,
locatethethermometerabovethedooroneithertheleftorrightsideofthestoveandusethe
followingtemperatures
asroughguidelinestodeterminetheburnrateandheatoutputlevelof
thestove:
o Normalwoodstoveoperationshouldoccurbetween350°F(177°C)and550°F(288°C),
with350°F(177°C)to450°F(232°C)beingalowtomedium heatoutputleveland450°F
(232°C)to550°F(288°C)beinga
mediumtohighheatoutputlevel.Operatingthestove
at600°F(316°C)wouldbeconsideredthemaximumcontinuousoperatingte mperature
permissibleandunitdamagemayresultfromoperatingatthathighofaburnratefor
extendedtimeperiods.Allowingtheunittoreach650°F(343°C)orhigherisdefinedas
overfiringandwillresultinunitdamage.
Theoptionalroomairconvectionblowerwasdesignedtoextractthemaximumamountofheat
fromthestove,forthehighestpossibleheattransferintotheroom.Sincetheblowerisso
efficientatremovingheatfromtheunit,itis
veryimportanttoonlyoperatetheroomairblower
afterafreshwoodloadhasbeenallowedtoburnforatleastthirty(30)minutes.Allowinga
freshloadofwoodtoburnwithoutthebloweronensuresthattheentireunitreachesproper
operationtemperaturesandthatthesecondarycombustion
systemisfunctioningproperly.
Additionally,followtheguidelinesbelowforacceptableblowerspeeds.
Whenusingtheoptionalroomairconvectionblower(PartNo.AC 16), theblowershouldbe
operatedasfollowsdependingonheatoutputlevel:
Burnrate High MediumHigh Medium MediumLow Low
BlowerSpeed High Low Low Low Off
DONOTUSEGRATEORELEVATEFIREBUILDWOODFIREDIRECTLYONHEARTH
DONOTOPERATEWITHTHEMAINDOOROPENOPERATINGTHESTOVEWITHTHEMAIN
DOOROPENWILLCREATEANOVERFIRE
Creosote
FormationandNeedforRemoval
Whenwoodisburnedslowly,itproducestarandotherorganicvapors,which
combinewithexpelledmoisturetoformcreosote.Thecreosotevapors
condenseintherelativelycoolchimneyflueofaslowburningfire.Asaresult,
creosoteresidueaccumulatesonthefluelining.Whenignited,thiscreosote
makes
anextremelyhotfire.Thechimneyandchimneyconnectorshouldbe
inspectedatleastonceeverytwomonthsduringtheheatingseasonto
determineifacreosotebuildup hasoccurred.Ifcreosotehasaccumulated,it
shouldberemovedtoreducetheriskofchimneyfire.
Page | 19
OPERATION
AdditionalSafetyGuidelines
Theinstallationofsmokedetectorsishighlyrecommendedwheninstallingthisoranyother
solidfuelburningappliance.Smokedetectorsshouldbelocatednearorineveryroomofthe
home,particularlysleepingrooms.
Asmokedetectorcanbeinstalledinthesameroomasthiscordwoodburning
unit;installingthe
smokedetectortooclosetotheunitcanleadtonuisancealarmsduetoslightwispsofsmoke
emittedduringthefirestartingorreloadingprocess.Duetothis,thesmokedetectorinthe
sameroomastheunitwillbemostusefulifitislocatedas
farfromtheunitastheroomwill
permit.
Thisstoveismeantforburningcordwoodonly;neverburnpressuretreatedwood,kilndried
wood,creosotetreatedwood(railroadties),icecoveredorwetwood,greenwood,driftwood,
charcoal,coal,cokeorANYotherfuel.
Burningfuels
otherthancordwood,particularlycoalandcharcoal,canresultinhazardous
concentrationsofcarbonmonoxidebeingemittedintothedwelling.Installingacarbon
monoxidedetectorandbeingawareofthesymptomsofcarbonmonoxidepoisoningcanhelp
reducetheriskofcarbonmonoxiderelatedissues.Forthesereasons,NEVERburncoal
or
charcoalinthiscordwoodstove.
Thisunitwasdesignedforoperationonlywiththeloadingdoorclosedandtightlylatched.
Operatingthisunitwiththeloadingdoorlatchedlooselyoropenwillallowexcessive
combustionairtoreachthefireandwillresultindangerouslyhighunittemperatures.
Highunit
temperaturescandamagetheunit,voidthewarrantyorignitecreosotedepositedinthe
chimneysystembyprevious,slowburningfires.
Thenaturaldraftthatpullsairthroughthisunitandallowsthefir etoburnusestheindoorairof
thedwellingforcombustion,unlesstheunit
isconnectedtoanoutsidecombustionairsource.
Kitchenrangeventhoods,furnacesandotherairmovement appliancesinthehomeareoften
alsoremovingairfromthedwelling;iftheamountofairfiltrationorleakagebackintothehome
isexceededbytheairbeingremoved,negativepressure
maybecreatedinthehome.
Sincethisisanaturaldraftappliance,itwilloftenbethefirstappliancetohaveproblemsrelated
tonegativepressure.Ifsmokeisforcedoutthechimneyconnectorjointsoroutoftheair
inductionsystemoftheunit,theunitislikely
fightingnegativepressureinthedwelling.
Crackingawindowordoorneartheappliancecanhelpequalizethenegativepressure;
ultimately,anunrestrictedsourceofoutsidecombustionmaybenecessaryforproperunit
function.
Iftheunitisconnectedtooutsideair,becertaintomonitortheexteriorinlet
tothecombus tion
systemforicingorsnowaccumulation.Allowingtheoutsideairco nnectiontobecome
restrictedwillresultinairstarvationtotheunit.
DONOTSTOREFUELCLOSERTHANSPECIFIEDCLEARANCESTOCOMBUSTIBLESOR
WITHINTHESPACENEEDEDFORLOADINGTHESTOVEANDFORASHREMOVAL.
Page | 20
MAINTENANCE
DailyMaintenance
Inspectthefireboxforashaccumulation;removeexcessashandfollowinstructions
belowregardingdisposal.Ashshouldnotbeallowedtoaccumulateinthestovetothe
pointthatitcoversthecoalbedairinlets.
MonthlyMaintenance
Checktheblowerfordustaccumulation(ifinstalled);checkthedoorhandleforproper
operationandtobecertainanairtightsealisstillbeingmadebythedoor.
Inspectthechimneysystemandchimneyconnectorandsweepifnecessary.Although
cleaningmayberequiredlessthanmonthly,
ALWAYSinspecttheventingsystem
monthlytodecreasethechanceofachimneyfire.
Visuallyinspectthevermiculiteinsulatingboardsinthefireboxforcracksand/or
breakage.Slightsurfacecrackswillnotaffecttheperformanceoftheboards,but
crackedorcrumblingboardsshouldbereplacedimmediately.
Visuallyinspect
thesecondarycombustiontubesforcracks,warpingandcorrosion.
Althoughthesetubesareconstructedfromstainlesssteel,theyoperateatveryhigh
temperaturesandcaneventuallywearoutfromnormaluse.
YearlyMaintenance
Checkallgaskets(windowanddoor)forwearandtobecertaintheystillmaintainan
airtightseal.Seethefollowingpageforinstructions.
Thoroughlycleanthechimneysystemandthechimneyconnectorsystem.Sincethe
chimneyconnectorisgenerallyexposedtohighexhausttemperatures,inspectit
carefullyforleaksandweakspots;replaceanyquestionablepieces.[Inthecaseof
straightthroughtheroofchimneysystem,becertaintoremovethevermiculitebaffle
beforepushingthechimneysweepingbrushdownintothefirebox.Forcefullyhitting
thetopofthebafflewithacleaningbrushorrodcandamage
ordestroythebaffle.]
Removeallashfromthestove,includingtheashwhichaccumulatesonthetopofthe
fireboxbaffles.Leavetheaircontrolopenduringthenonheatingmonthstoallow
someairtoflowthroughthestovetohelppreventcorrosion.Asmallopencontainer
of
catlitterinthestovecanhelppreventcorrosionduringthehumidsummermonths;be
certaintoremoveitbeforebuildingafireinthefall.
DisposalofAshesAshesshouldbeplacedinametalcontainerwithatightfittinglid.The
closedcontainerofashesshouldbeplacedonanoncombustiblefloororontheground,well
awayfromallcombustiblematerials,pendingfinaldisposal.Iftheashesaredisposedofby
burialinsoilorotherwiselocallydispersed,theyshouldberetainedintheclosedcontainer
untilallcindershavebeenthoroughlycooled.
IMPROPERGASKETMAINTENANCE,INCLUDINGFAILURETOREPLACEGASKETS,CAN
CAUSEAIRLEAKSRESULTINGINANUNCONTROLLABLEUNIT.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

England's Stove Works Stove 17VL User manual

Category
Stoves
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI