TEAC HS-4000 Release note

Type
Release note
HS-4000 Release Notes
TASCAM HS-4000 1
D01165720A
Contents
Updates ................................................................................................1
New functions ...................................................................................1
V1.21 additions ...........................................................................1
Maintenance items ..........................................................................1
V1.21 fixes.....................................................................................1
Checking the firmware version ...................................................2
Firmware update procedures .......................................................2
Updates
Always use the most recent rmware for this unit.
Please visit the TASCAM website (http://tascam.com/) to
check for the latest rmware.
New functions
V1.21 additions
Playback of WAV les that are not BWF format is now
supported.
Automatic recognition of external les has been added.
Manual locating based on time code time has been
added to take and playlist modes.
When a new project or session is created, the take
name is reset to the default.
A progress bar has been added when recording in take
mode.
When a digital input unlock event is detected, the
input signal is no longer muted.
In order to allow you to conrm the status of
condence monitoring on the Home Screen, a
condence monitoring button (icon) has been added
between the transport icon and the time display on the
Home Screen.
For Playlist mode, changes have been made to the
operation of the
ADJUST
screen, and a rehearsal
playback function for audio monitoring has been
added.
Assignment changing has been made possible on the
ENTRY
list screen.
The BC$STANDBY/END range can now be changed in
one operation.
An on air mode that plays back les in the root folder
has been added.
A BC$END operation mode setting has been added.
SONY P2 REC commands are now supported.
System setting backup and preset memory functions
have been added.
ON/OFF settings have been added for Auto Marker
PRE
/
REC
/
END
.
The bounce save destination can now be selected.
A take copy function has been added.
An
ETHERNET
page has been added to the
REMOTE
SETUP
screen.
Network functions (FTP/Telnet/VNC) have been added.
NOTE
For details, see “New functions added in rmware V1.21”
in the HS-4000 insertion sheet.
Maintenance items
V1.21 fixes
If loading a le fails during playback in timeline mode,
playback will continue with silence instead of stopping.
If PreRec was ON and recording was started from “00:00”,
recording would stop and a
RECORD stopped. ABS
time is over 24h
pop-up message would appear.
This has been xed.
When recording with the
SYNC T/C
screen
SETUP
page
TC GEN MODE
item set to
REGEN
or
JAM SYNC
,
the precision of the start time added to the le at the
time of recording has been increased.
When the
SYNC T/C
screen
SETUP
page
TC GEN
MODE
item was set to
TIME OF DAY
, if the unit’s
internal clock was adjusted, the time code generator
did not chase the time after the adjustment. This has
been xed.
When a PPL le is imported, even if there are
mismatched entries (entries with missing les), the
remainder of the entries are now properly registered.
In some cases, marks could not be added to les that
had not been created by this unit. This has been xed.
When reconrmation pop-up messages for various
operations appeared on the
CF Manage
screen, the
physical key bindings were reversed. Pressing the
ENTER key would cancel the operation, and pressing
the EXIT/CANCEL would execute the operation. This
has been xed.
Pop-up messages would not disappear in some cases.
This has been xed.
In dual playlist mode, when changing operation mode,
for example, before the playlists had been saved, saving
was conrmed for the A and B playlists separately. Now
saving both A and B playlists is conrmed at the same
time.
If you use a
e button on the
PROJECT
screen to load
a project with a dierent Sampling Rate or Timecode
setting, the values shown for the
Total Time
and the
Take Length
of the session were incorrect. This has
been xed.
HS-4000 Release Notes
2 TASCAM HS-4000
If the root directory of the CF card contained many les,
the rmware update screen might not correctly show
the available update les. This has been xed.
In take mode, only one retake could be conducted. This
has been xed.
Online playback has been xed, so that locate
commands can no longer be received.
BC$ marks at the beginnings and ends of les might
not function with BWF-J. This has been xed.
When the
PLAY SETUP
screen
CONTROL
page
Auto
Cue
setting is ON, pressing the PAUSE key when
stopped at the beginning of a take will now start Auto
Cue search.
After changing the name of a project, RC-HS32PD keys
would not show the take names. This has been xed.
When changing the operation mode after formatting a
CF card, the CF card remain time display on the Home
Screen would not show
No Project
. This has been
xed.
In dual playlist mode, when loading a CF card that
did not contain any project or session, the indicator
at the side of the CF card slot would continue to blink
and creating a new project or session would not be
possible. This has been xed.
After loading a project that did not contain any
sessions, the color display and RC-HS32PD keys would
continue to show the project and session information
from before loading. This has been xed.
When importing an AES31 le, if the designated region
size is longer than the audio le, the extra time will
now be added as silence.
The following setting values had been saved in CF card
project setting les. They are now saved to the unit’s
built-in memory instead.
OUTPUT 1-4 SOURCE
PLAY INHIBIT TIME
MASTER T/C
FADER MODE
FADER START MODE
FADER STOP MODE
The WAV bext chunk size was 2 bytes larger than the
standard size. This has been xed.
During recording, when the
SYNC T/C
screen
SETUP
page
TC GEN MODE
item was set to
REC RUN
mode,
removing the CF card that was not set as the current
one would cause the TC generator to stop. This has
been xed.
In take mode, if you changed the operation mode
when stopped after adding a mark, the mark would not
be added to the audio le. This has been xed.
In timeline mode, if you added a mark, a mark would
also be added to the audio le. This has been xed.
In dual playlist mode, if you changed to take mode
after adding an entry to player B, the mark list would
stop being shown. This has been xed.
When using BWF/WAV les that had been edited
by something other than this unit, if you edited
mark information using this unit, marks would stop
appearing on the
MARK LIST
screen. This has been
xed.
In dual playlist mode, if you assigned the same take to
the same entry in both players A and B, marks would
stop being shown in the
MARK LIST
screen. This has
been xed.
Operation stability has improved.
Checking the firmware version
Before conducting a rmware update, check the rmware
version currently installed in your HS-4000.
1 Turn the unit power ON.
2 Press the MENU key on the front panel to open the
MENU
screen.
3 Press the
VERSION
INFO
button.
Check the
SYSTEM
VERSION
here. If this firmware
version is the same as or newer than the version
that you intend to use for updating, there is no
need to update the unit.
Firmware update procedures
1 Download the latest version of the firmware from
the TASCAM website (http://tascam.com/).
2 Copy the downloaded firmware from the computer
to the root folder of the CF card.
3 After copying is completed, follow the correct
procedures to dismount the CF card from the
computer.
4 Insert the CF card into CF card SLOT 1 on the front
panel of the unit.
CAUTION
For this procedure, always insert the CF card into CF card
SLOT 1. You cannot update using CF card SLOT 2. In order
to avoid transferring the le to CF card SLOT 2, do not put
a CF card into SLOT 2.
5 While pressing and holding the PAUSE and REC
keys at the same time, turn the unit power on.
The unit restarts in update mode, and the updater
file is shown on the screen.
HS-4000 Release Notes
TASCAM HS-4000 3
CAUTION
If the above screen does not appear, turn the power o
once, and then turn the power on again while pressing
and holding the PAUSE and REC keys. Keep pressing
the PAUSE and REC keys rmly until the above screen
appears
NOTE
The screen shown above lists rmware update les
contained in the root folder of the CF card inserted in
the unit’s CF card SLOT 1. The rmware copied in step
2 should appear.
No Update File
appears instead if
there is no update le.
A maximum of ve lines of rmware les are shown.
If the number of les exceeds this maximum, use the
scrollbar with the up and down arrow buttons that
appears on the right side of the screen or the DATA dial
to scroll through the list.
6 Touch the name of the firmware file that you want
to use to update. The following screen appears.
The left side shows the number of the current
version, and the right side shows the number of
the update version.
NOTE
The screen above is just an example. The actual display
will be dierent.
7 Touch the
YES
button to start the update.
CAUTION
Do not turn the power o while updating.
8 After updating completes,
Complete
and
PLEASE
POWER OFF
appear at the bottom of the screen.
Turn the power off once and then restart the unit.
9 See Confirming the firmware version above and
confirm that the
SYSTEM VERSION
(firmware
version) is the newest one. This completes
updating the unit.
  • Page 1 1
  • Page 2 2
  • Page 3 3

TEAC HS-4000 Release note

Type
Release note

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI