The HANMI TECHWIN TDC-9030 is an industrial battery charger that can be used for a variety of applications. It is a compact and lightweight device that is easy to handle and transport. The TDC-9030 has a number of features that make it a valuable tool for any industrial setting.

  • Simplicity: The TDC-9030 is easy to operate, with a simple user interface that makes it easy to set up and use.
  • Monitoring: The TDC-9030 has a built-in LCD display that shows the battery voltage, current, and charge capacity. This allows you to monitor the charging process and ensure that the battery is being charged correctly.

HANMI TECHWIN TDC-9030

The HANMI TECHWIN TDC-9030 is an industrial battery charger that can be used for a variety of applications. It is a compact and lightweight device that is easy to handle and transport. The TDC-9030 has a number of features that make it a valuable tool for any industrial setting.

  • Simplicity: The TDC-9030 is easy to operate, with a simple user interface that makes it easy to set up and use.
  • Monitoring: The TDC-9030 has a built-in LCD display that shows the battery voltage, current, and charge capacity. This allows you to monitor the charging process and ensure that the battery is being charged correctly.
TDC-9030
Industrial Battery Charger
Operating manual
TEL: +82-31-498-9270
FAX: +82-31-498-9275
Industrial Battery Charger TDC-9030
1 HANMI TECHWIN. CO., LTD.
Contents
2
2
3
3
3
4
4
5
6
7
8
9
10
11
11
11
12
12
13
1. Introduction
2. Characteristics
3. Purpose
4. Basic Specification
4-1. Type name
4-2. Specifications
5. Wiring Diagram
5-1. Outside view of terminal block
5-2. Explanation of terminal block
6. Configuration and Operation Principle
6-1 Power circuit configuration diagram
6-2 Control board configuration diagram
7. Display
7-1 Parameter setting
7-2 Monitoring
8. Outside dimension
9. Trial run recommendation sequence
10. Fault and Warning Description
10-1. Fault list
10-2. Fault Cause and Action
10-3. Warning list
10-4. Warning Cause and Action
10-5. Warning Display
11. Caution for operation
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 2
1. Introduction
The all-digital battery charger (BCU) developed by HANMI TECHWIN is a
device that charges the battery by making high-speed switching method
using 3-phase AC power using IGBT.
BCU (Battery Charging Unit) monitors and protects battery status in real
time to provide optimal operating environment.
2. Characteristics
Simplicity
Charge automatically with battery capacity (AH) and battery rating setting only.
Monitoring charging voltage and current through LCD
Charge voltage, current and charge capacity are displayed, so you can check it
immediately without any additional measuring equipment.
Small, lightweight
It is compact and lightweight because it does not adopt transformer and
large capacitor, and it is easy to handle.
Battery diagnostic function
It continually checks the battery's overvoltage, discharge end voltage and
other conditions to ensure that it is always in top condition.
Equal charge function
Equalization charging is performed when the voltage between the terminals of
the battery and the specific gravity of the electrolyte is not uniform and the
performance can not be fully demonstrated. This function charges the battery
at a constant voltage (117% of the battery rating) during Equalizing time.
When the set time has elapsed and the equal charge is completed, the auto
run parameter is automatically switched to floating charge if the parameter
is set to ON. If it is OFF, the output is stopped.
Recovery charge function
When the battery voltage is below the discharge end voltage (75% of the
rated voltage), it automatically operates in the recovery charge (RC) mode and
is also possible by key operation. The recovery charge is slightly higher than
the battery rated voltage for safety, and when the battery voltage exceeds the
rated voltage, it charges to 115% of the battery rating. When the recovery
voltage and current reaches the appropriate level (voltage is 115% and current
is battery capacity / 50 or less), depending on the setting of Auto Run, it
changes to a floating charge or standby state.
Industrial Battery Charger TDC-9030
3 HANMI TECHWIN. CO., LTD.
Enhanced fault diagnosis
Improved safety by checking the battery itself and wiring.
3. Purpose
Industrial Battery Charger
4. Basic Specification
4-1. Type name
TDC - 9030 -
TAIHWA
DEVELOPMENT
BATTERY CHARGER
FAN POWER
1 : 110 V
2 : 220 V
REVISION
DEVELOPMENT DATE
3 : MONTH
90 : 2009(year)
4-2. Specifications
Specifications
Contents
Power supply
3Ø AC 220V
Operating
voltage
AC 85 ~ 265 [V]
FAN Power
AC 110 / 220 [V]
Operating
temperature
-20 ~ 85 []
Output signal
WARNING OUT
(Mechanical contact : AC250V/DC30V, 5A)
FAULT OUT
(Mechanical contact: AC250V/DC30V, 5A)
weight
11.5 Kg
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 4
5. Wiring Diagram
5-1. Outside view of terminal block
T
S
R P
B
N
STACK
(TDC-9030Series)
L2
L1
WA WB WC FA FB FC
NO
NC
COM
NO
NC
COM
(PCB)
5-2. Explanation of terminal block
Terminal
Designation
Function
Rating
CN103
1
NORMAL OPEN
WARNING OUTPUT
AC250V / 5A
DC 30V / 5A
2
NORMAL CLOSE
3
COMMON
4
NORMAL OPEN
FAULT OUTPUT
5
NORMAL CLOSE
6
COMMON
LINE1
CONTROL POWER
PCB POWER
AC 85V ~
AC265V
LINE2
CONTROL POWER
PCB POWER
BUSBAR
Source Voltage
R PHASE INPUT
Source Voltage
S PHASE INPUT
Source Voltage
T PHASE INPUT
DC OUTPUT (+)
LOAD OUTPUT (+)
DC OUTPUT (+)
BATTERY OUTPUT(+)
DC COMMON (-)
COMMON (-)
Industrial Battery Charger TDC-9030
5 HANMI TECHWIN. CO., LTD.
6. Configuration and Operation Principle
MAIN
CNTR
R
Fuse
SMPS
S
T
P
B
N
D2
SW1
RECT.
TB
L2L1 Warning
Fault
LC
N
SV
BV
G1
E1
OH
IGND
[figure 1] Diagram
6-1. Power circuit configuration diagram
Mark
Designation
Function
Remarks
R
Source Voltage (R Phase)
Input Voltage
S
Source Voltage (S Phase)
T
Source Voltage (T Phase)
P
Positive Voltage
Output Voltage(Load)
B
Battery Voltage
Output Voltage(Battery)
N
Neutral Node
Output Voltage(Common)
P
B
N
R
S
T
G1
E1
G2
E2
20A
SV
BV
NLC
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 6
6-2. Control board configuration diagram
Mark
Designation
Function
Remarks
CN301
SV
Source Voltage
Voltage / Current
Feedback
BV
Battery Voltage
LC
Load Current
N
Neutral Node
CN103
WA
Warning NO
Warning Output
WB
Warning NC
WC
Warning Common
FA
Fault NO
Fault Output
FB
Fault NC
FC
Fault Common
CN201
G1
Gate Signal 1
IGBT Gate Signal
E1
Emitter Signal 1
CN401
+12V
PCB Power (+12V)
PCB Power
GND
Ground (0V)
CN102
OH
Overheat
Thermostat
( 85 NO )
COM
Common
SET RUN
UP EQU
DN REC
OH COM
THERMAL
SWITCH
+12V GND
POWER
WA WB WC FA FB FC
STATUS OUTPUT
G1 E1/C2
IGBT
MODULE
SV BV LC N
VOLTAGE
FEEDBACK
RESET
T.H. ELEMA
P9062A-04
TP201
TP201
(GND)
PWR
CN201
CN301
CN103
CN102
CN401
LD401
Industrial Battery Charger TDC-9030
7 HANMI TECHWIN. CO., LTD.
7. Display
7-1. Parameter setting
7-1-1. Parameter type and description
Parameter
Setting
Range
Default
Auto Run
OFF / ON
OFF
Batt. Voltage
24 ~ 240 [V]
216 V
Batt. Capacity
10 ~ 300 [AH]
100 AH
Output Current
1.0 ~ 30.0 [A]
Capacity / 20
Equalizing Time
30 ~ 180 [min]
120 min
*Max. Current
1.0 ~ 30.0 [A]
20.0 A
*Halt on WDR
OFF / ON
ON
Caution 1) In case of actual use after the test run, be sure to set Auto Run to
ON to charge the battery automatically.
Caution 2) The mark ‘*’ can not be arbitrarily adjusted by the user.
Auto Run : Set which mode to start at initial startup
- This parameter is used when the MCU starts to operate due to Power
ON or Reset. If it is set to OFF, start and stop of charging can be
controlled with the RUN key.
Batt. Voltage : Set the battery voltage.
- If 18 batteries of 12V are used in series, set to 12 × 18 = 216 [V].
The Floating Charge charges 111% of the battery voltage and the
Equalized Charge charges the constant voltage / constant current to
117% of the battery voltage.
Batt. Capacity : Set the battery capacity.
- If the battery capacity is 100AH, setting 100 will automatically set the
parameter Max. Out Currentto 5A, which is the charging standard
for
20 hours.
Output Current : Sets the output current limit.
- Set the current that the charger can output at maximum. This limit
setting allows you to safeguard your battery and circuit, especially
when large currents can flow, such as a recovery charge.
Equalizing Time : Set the equal charge time.
*Max. Current : An overcurrent fault occurs when the charger exceeds
the set current.
*Halt on WDR : Set or cancel the self-diagnosis function of the MCU.
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 8
7-1-2. How to set parameters
7-2. Monitoring
7-2-1. Initial Screen
7-2-2. Screen during driving
DCV :
DC voltage on the DC-Link side
Indication of
operation status
Output Current
3
O
UT : 0 0
V
0 . 0
Battery Voltage
0 V [ RD ]
. A
0
2 4
DCV :
DC voltage on the DC-Link side
Output Current
3
O
UT : 0 0
V
5 . 0
Battery Voltage
0 V [ F L ]
. A
0
2 4
RD, FL, EQ, RC
# Initial
Screen
SET(1sec)
SET(1sec)
UPDOWN
UP
DOWN
Press SET key for 1 sec. In
parameter state to return to
initial screen
SET
SET
Adjust the setting value
by UP and DOWN
All parameter settings except '*' are
the same
Parameters with Asterisk(*) are not user
configurable
Ba
1
t
6
V
t . V o l t a g e
2
O
F
F
Au t o RUN
.
2 0
A
Ma x . c u r r e n
0
t
UP
DOWN
O
.
u
1 0 0
A
t pu t Cu r r e n t
2
0
mi
u a l i z i n g t i
1
n
e
UP
DOWN
qE m
O
N
Au t o RUN
DOWN
UP
UPDOWN
Ba
0
t
0
A
t . Ca p a c i t y
1 H
DCV :
3
O
UT : 0 0
V
0 . 0
0 V [ RD ]
. A
0
2 4
UP
DOWN
O
N
Ha l t o n WDR
*
*
Can not be set in RUN mode(FL, EQ,
RC)
[Monitorable]
Industrial Battery Charger TDC-9030
9 HANMI TECHWIN. CO., LTD.
8. Outside dimension
MODEL : TDC-9030-
SN :
DATE : 20 . . . MADE IN KOREA
BATTERY CHARGER UNIT
THE LEADER OF INDUSTRIAL ELECTRONICS
HANMI TECHWIN. CO., LTD.
http://www.hanmitw.com/
G
D
A
C
F
B
E
4-Ø 7
The above dimensions may be changed to improve
the product.
246.0 mm
300.0 mm
208.2 mm
234.0 mm
361.0 mm
200.0 mm
A
B
C
D
E
F
G
DIMENSION
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 10
9. Trial run recommendation sequence
1) Be sure to check the polarity of battery power before applying power.
[Caution] Be extremely careful not to connect the battery (+) to the output
(B) of the controller, as this may damage the diodes and reactors of the
controller.
2) Apply single-phase AC [L1, L2] power for PCB power supply.
3) If 'PF' fault message is displayed on the LCD, press and hold SET key to
enter parameter setting mode.
4) Press UP, DOWN, SET Key[Refer to parameter setting method] to set Batter
AH and Auto Run to OFF. Then press and hold the SET key to exit the
setting mode and a 'PF' fault message will be displayed again.
5) Apply 3 phase power of the controller to clear the fault and check the LCD
window display.
6) Make sure that the SV voltage matches the actual input source voltage and
that the BV voltage is at 0V.
7) Apply battery voltage and verify BV voltage matches actual battery voltage.
8) Press the RUN key to charge the battery while observing the OC [Output
Current] current.
9) If the current and voltage are not abnormal, press the RUN Key again to
stop charging.
10) Press and hold SET key to set Auto Run to ON in parameter
setting mode.
11) Press the RUN key to charge the battery.
Check battery polarity and wiring status
PCB power supply L1, L2 power supply
POWER FAULT occurrence
Parameter setting
SET Key(1Sec)
Auto Run : OFF
Batt. Capacity :Battery capacity
SET, UP, DN Key
SET Key(1Sec)
POWER FAULT occurrence
3-phase input MCCB ON
SV: Voltage check (input power)
Check BV after battery voltage
MCCB ON
Check operation status
(OC and BV observations)
RUN Key
In the Ready state, press the SET key to
set Auto Run to ON
RUN Key
Battery charge status observation
RUN Key
Industrial Battery Charger TDC-9030
11 HANMI TECHWIN. CO., LTD.
10. Fault and Warning Description
10-1. Fault list
NO
Display
Cause
1
[FAULT] GATE-DRV
IGBT Gate Driver Damage
2
[FAULT] WATCHDOG
Abnormal operation of MCU
3
[FAULT] OVR-CURR
Overcurrent
4
[FAULT] BAD BATT
Battery failure
10-2. Fault Cause and Action
LIST
Cause and Action
[FAULT]
WATCHDOG
Watchdog / Abnormal MCU function
If the MCU malfunctions momentarily due to noise or other external
conditions
Reset the MCU.
[FAULT]
GATE-DRV
Gate Driver Defect / Damaged Gate Driver
If the IGBT Gate Driver is physically damaged
Turn off all the power and then turn it on again.
If the fault persists, replace the PCB because it is a physical damage.
[FAULT]
OVR- CURR
Over Current / Overcurrent
Overcurrent flows above set current
Check the output wiring.
[FAULT]
BAD BATT
Bad Battery / Discharge
If current is not flowing even when voltage is continuously applied
to the battery
Check the battery condition.
Charge the battery in Equal Charge [EQU Key] mode..
10-3 Warning list
NO
Display
Cause
1
PF
Power Fault
2
PL
Power Too Low
3
OH
Over Heat
4
OV
Over Voltage
5
LV
Low Voltage
TDC-9030 Industrial Battery Charger
HANMI TECHWIN. CO., LTD. 12
10-4 Warning Cause and Action
LIST
Cause and Action
PF
Power Fault / Abnormal input power
Input power (AC power) is not applied.
Check the input power line. If there is no problem
Check the fuse inside the unit for burnout
PL
Power Too Low / Input Power Undervoltage
The input voltage is lower than the set battery voltage.
Check the input power line.
OH
Over Heat
Unit temperature is over 85 .
Check the ambient temperature and the air circulation inside the unit
Check whether the fan is abnormal, check the connection of the unit
internal temperature sensor.
OV
Over Voltage / Overcharge
The battery voltage is overcharged (25% or more of the rated voltage).
Check if charging stops and charging starts when the battery voltage
is discharged to the rated voltage.
Make sure the battery voltage setting is correct
LV
Low Voltage / Overdischarge
Battery voltage is over-discharged (less than 25% of rated voltage).
Make sure that it is charging. The warning is released when the
battery continues to charge and the battery voltage is reached.
10-5 Warning Display
* If it is displayed like this, it is charged to 5A with input voltage of 220VAC (DCV 300V).
However, the battery voltage (OUT: 140V) does not reach the rated voltage (216V Setting)
and LV Warning (low voltage) is displayed.
* It operates normally even during alarm. (Reset is not required)
DCV :
Warning status display (flashing)
3
O
UT : 0 0
V
5 . 0
0 V [ F L ]
. A
0
1 4
PF,PL,OH,OV,LV
LV
Industrial Battery Charger TDC-9030
13 HANMI TECHWIN. CO., LTD.
11. Caution for operation
1) This product contains sensitive electronic components. Opening the
lid of the product and touching the electronic components at will is
dangerous and may cause a fatal malfunction.
2) Be sure to turn off all power supply when replacing PCB and
maintenance. High Voltage inside the product may cause fatal
injuries.
3) Although this product is designed to withstand noise and surge in
power supply. However, excessive noise, surge, etc. may cause
abnormal operation, so please use stable power as much as possible.
4) Always use the correct rated product for the device protection fuse.
5) If any information not explained in this manual is displayed on the
display, please contact us at 031-498-9270.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

HANMI TECHWIN TDC-9030 Operating instructions

Category
Rechargeable batteries
Type
Operating instructions

HANMI TECHWIN TDC-9030

The HANMI TECHWIN TDC-9030 is an industrial battery charger that can be used for a variety of applications. It is a compact and lightweight device that is easy to handle and transport. The TDC-9030 has a number of features that make it a valuable tool for any industrial setting.

  • Simplicity: The TDC-9030 is easy to operate, with a simple user interface that makes it easy to set up and use.
  • Monitoring: The TDC-9030 has a built-in LCD display that shows the battery voltage, current, and charge capacity. This allows you to monitor the charging process and ensure that the battery is being charged correctly.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI