s WARNING
!
s WARNING
!
Before Getting Started
Read and follow safety instructions. Refer to product data plate(s) for additional operating
instructions and specications.
s CAUTION
!
s CAUTION
!
RISK OF ELECTRIC SHOCK - This pump is supplied with a grounding conductor and grounding-type
attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly
grounded, grounding-type receptacle. Disconnect power before servicing.
This equipment should be installed by technically qualied personnel. Failure to install it in compliance
with national and local electrical codes and within Franklin Electric recommendations may result in
electrical shock or re hazard, unsatisfactory performance or equipment failure.
This equipment must not be used by children or persons with reduced physical, sensory or mental
abilities, or lacking in experience and expertise, unless supervised or instructed. Children may not use
the equipment, nor may they play with the equipment or in the immediate vicinity.
If the power cord is damaged, it must only be replaced by qualied personnel.
Keep work area clean, well-lit, and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing maintenance on pump.
Do not run pump dry. Fill pump with water before starting or pump will be damaged.
Make sure all ELECTRICAL POWER IS OFF before connecting any electrical wires.
s WARNING
!
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for
one of the following signal words and be alert to the potential for personal injury:
s WARNING
!
DANGER
s WARNING
!
NOTICE
warns about hazards that will cause serious personal injury, death or major
property damage if ignored.
warns about hazards that can cause serious personal injury, death or
major property damage if ignored.
warns about hazards that will or can cause minor personal injury or major
property damage if ignored.
indicates special instructions which are important but not related to hazards.
Carefully read and follow all safety instructions in this manual and on pump.
Table of Contents
Before Getting Started ............................................................2
Getting Started ..................................................................4
Typical Installation................................................................5
Specications ...................................................................6
Pump Performance Curves.........................................................6
Electrical Connections ............................................................7
Operation .......................................................................8
Testing Pump Operation ...........................................................8
Service Instructions...............................................................9
Replacement Parts ..............................................................10
Troubleshooting Information.......................................................12
Limited Warranty ................................................................13
4
6EC - 10EC Series
Getting Started
This instruction sheet provides you with the information required to safely own and operate your
product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and material, and has been
engineered to give you long and reliable service.
This product has been carefully tested, inspected, and packaged to ensure safe delivery
and operation.
Please examine your item(s) carefully to ensure that no damage occurred during shipment. If
damage has occurred, please contact the place of purchase.
They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE,
OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, LIMITATIONS, AND
POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
Description
This is a submersible efuent pump for use in basins or lift stations, and is suitable for pumping
sewage, efuent, wastewater, and other non-explosive, non-corrosive liquids with up to 1/2"
spherical solids.
Safety Guidelines
1. Make certain pump is disconnected from power source before attempting to service or
remove any component.
2. Do not use to pump ammable or explosive uids such as gasoline, fuel oil, kerosene, etc.
DO NOT use in explosive atmospheres or hazardous locations as classied by NEC, ANSI/
NFPAT. Pump should be used with liquids compatible with pump component materials.
3. Do not handle the pump with wet hands or when standing on a wet or damp surface or
in water.
4. Do not pull the pump out of the water by the power cord when the pump is operating or
connected to power source.
5. This pump is supplied with a grounding conductor and/or grounding type attachment plug.
To reduce the risk of electrical shock, be certain that it is connected to a properly grounded
grounding-type receptacle.
6EC - 10EC Series
5
6. The National Electric Code requires a ground fault circuit interrupter (GFCI) be installed in the
branch circuit supplying fountain equipment, pools, etc.
7. In any installation where property damage and/or personal injury might result from an
inoperative or leaking pump due to power outages, discharge line blockage, or any other
reason, a backup system(s) and/or alarm should be used.
8. Support pump and piping when assembling and when installed. Failure to do so may cause
piping to break, pump to fail, motor bearing failures, etc.
9. This pump’s motor housing is lled with a dielectric oil for motor heat transfer and lifetime
lubrication of the bearings. This oil is non-toxic to aquatic life. However, suffocation can
occur if oil is left on the water surface. If oil escapes the motor housing it can be removed
from the surface quickly by placing newspapers on the water surface to soak up the oil.
10. The pump motor is equipped with an automatic resetting thermal protector and may
restart unexpectedly. Protector tripping is an indication of motor overloading as a result
of excessively high or low voltage, inadequate wiring, incorrect motor connections, or a
defective motor or pump.
Typical Installation
Figure 1
SFS Models
• 7" - 10" on level
• 7 po à 10 po à niveau
• 7" a 10" en el nivel
SFS Models
• 2" - 5" off level
2 po à 5 po outre du niveau
• 2" a 5" de nivel
RF Models
• 13" - 15" on level
• 13 po à 15 po à niveau
• 13" a 15" en el nivel
RF Models
• 6" - 8" off level
6 po à 8 po outre du niveau
• 6" a 8" de nivel
6
6EC - 10EC Series
Specications
Pump Performance Curves
6EC
10EC
GALLONS PER MINUTE, AT HEIGHT
L I T R E S P A R M I U N T E Á L A H A U T E U R
LITRES POR MINUTO, A UNA ALTURA
Shut-Off
Descibexion
Debit Nul
5 '
1.5 m
1 0 '
3 m
1 5 '
4.5 m
2 0 '
6.1 m
30'
9.1 m
6EC
53 50 42 34
-
28'
201 189 159 129 8.5 m
10EC
67 57 47 42 24 36'
254 216 178 159 91 11 m
0
3
6
9
0 30 60 90 120 150 180 210
0
5
10
15
20
25
30
0 10 20 30 40 50 60
HEAD - METERS
FLOW - LITERS/MINUTE
HEAD - FEET
FLOW - GALLONS/MINUTE
0
2
4
6
8
10
12
0 50 100 150 200 250
0
5
10
15
20
25
30
35
40
0 10 20 30 40 50 60 70
HEAD - METERS
FLOW - LITERS/MINUTE
HEAD - FEET
FLOW - GALLONS/MINUTE
6EC - 10EC Series
7
Electrical Connections
1. Check the pump label for proper voltage required. Do not connect to voltage other than
that shown.
2. If pump is supplied with a 3-prong electrical plug, the third prong is to ground the pump to
prevent possible electrical shock hazard. DO NOT REMOVE the third prong from the plug. A
separate branch circuit is recommended.
Do not use an extension cord. Do not cut plug from the cord. If the plug is cut or the cord is
shortened, then this action will void the warranty.
3. Check local electrical and building codes before installation. The installation must be in
accordance with their regulations as well as the most recent National Electrical Code (NEC).
4. To conform to the National Electrical Code all pumps must be wired with 14 AWG or
larger wire. For runs to 250', 14 AWG wire is sufcient. For longer runs, consult a qualied
electrician or the factory.
5. Pump should be connected or wired to its own circuit with no other outlets or equipment in
the circuit line. Fuses and circuit breaker should be of ample capacity in the electrical circuit.
6. The exible PVC jacketed cord assembly mounted to the pump must not be modied in any
way, with the exception of shortening the cord to t into a control panel. Any splice between
the pump and the control panel must be made within a junction box and mounted outside of
the basin and comply with the National Electrical Code.
7. The 6EC-CIA-RF AND 10EC-CIA-RF pumps have automatic switches with piggyback
plugs on the switch cords. Pump must be plugged into piggyback switch cord for
automatic operation.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY AND
DISASSEMBLY OF YOUR LITTLE GIANT PUMP.
Figure 2
8
6EC - 10EC Series
Operation
1. Pump must be installed in a suitable gas tight basin which is at least 18" in diameter and 24"
deep, and vented in accordance with local plumbing codes.
2. Pump features a 1-1/2" female NPT discharge.
3. Pump must be placed on a hard level surface. Never place pump directly on clay, earth or
gravel surfaces.
4. A check valve must be used in the discharge line to prevent back ow of liquid into the basin.
The check valve should be a free ow valve that will easily pass solids.
CAUTION: For best performance of check valves, when handling solids install in a horizontal
position or at an angle of no more than 45°. Do not install check valve in a vertical position, as
solids may settle in valve and prevent opening on start-up.
5. Do not attempt to restrict the intake side of these pumps. Restricting the intake may cause
damage to the seal and may starve the pump. If you require reduced ow rates, then place
a valve on the discharge side of the pump or if exible vinyl tubing is used, a clamp can be
used on the tubing to restrict the ow.
6. Do not let the unit run dry (without liquid). It is designed to be cooled by pumping uid. You
may damage the seal and the motor may fail if the pump is allowed to run dry.
7. If the unit is going to be idle for a period of time, follow the cleaning instructions outlined
in the next section. Do not let the unit freeze in the wintertime. This may cause cracking or
distortion that may destroy the unit.
Testing Pump Operation
CIA Series Efuent Pumps
1. These pumps are equipped with a oat operated mechanical switch.
2. When these pumps are installed in a basin with a sealed cover, switch operation cannot be
observed. The sump cover usually will have an additional opening that is plugged with a
rubber plug. This plug can be removed and switch operation can be observed.
3. Plug power cord into a grounded receptacle with voltage consistent with pump voltage as
indicated on pump nameplate.
4. Run water into pump until pump starts.
5. Be sure gate valve in discharge line is open.
6. Allow pump to operate through several on off cycles.
CIM Series Efuent Pumps
1. The pump cord for these pumps can be plugged directly into a properly grounded receptacle
with voltage consistent with pump nameplate for continuous pump operation.
CAUTION: This type of operation should be used only for emergency use or when a large volume
of water is to be pumped. Pump must not be allowed to run dry. If pump is run dry, it may damage
pump and void the warranty.
6EC - 10EC Series
9
Service Instructions
Instructions
MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE POWER SOURCE BEFORE
ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT!
1. If pump does not operate properly, consult TROUBLESHOOTING section. If trouble still
cannot be located, consult your pump dealer or take pump to a Little Giant authorized
service center.
2. This unit is permanently lubricated. Oiling is not required. Do not, in any case, open the
sealed portion of the unit or remove housing screws.
3. Periodic cleaning of the pump parts will prolong the LIFE and EFFICIENCY of the pump.
Refer to the assembly and disassembly of the pumping head.
4. Remove screws that hold base to volute and clean impeller and volute passage. Do not use
strong solvents on impeller.
5. Be sure impeller turns freely after cleaning.
6. WARNING: DO NOT REMOVE IMPELLER. REMOVAL OF IMPELLER REQUIRES SPECIAL
TOOLS AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER.
DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY IS VOID IF MOTOR HOUSING
COVER, IMPELLER OR SEALS HAVE BEEN REMOVED. ANY REPAIR ON MOTOR MUST BE
DONE BY AN AUTHORIZED LITTLE GIANT SERVICE CENTER.
7. Be certain power cord is in good condition and contains no nicks or cuts.
SEWAGE & EFFLUENT 2 YEAR WARRANTY STATEMENT
LIMITED WARRANTY
THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S
EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT.
Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants
that the products accompanied by this warranty are free from defects in materials or workmanship
of the Company that exist at the time of sale by the Company and which occur or exist within the
applicable warranty period. Any distributor, sub-distributor, recipient, end-user and/or consumer
agrees that by accepting the receipt of the products, the distributor, sub-distributor, recipient, end
user and/or consumer expressly agrees to be bound by the terms of the warranty set forth herein.
I. Applicable Warranty Period
The products accompanied by this warranty shall be covered by this Limited Warranty
for a period of 24 months from the date of original purchase by the consumer. In the absence
of suitable proof of purchase date, the warranty period of this product will begin to run on the
product's date of manufacture.
II. Instructions Applicable to this Limited Warranty
1. Consumers wishing to submit a warranty claim must return the products
accompanied by this warranty to the point of purchase for warranty consideration.
2. Upon discovery of a defect, any personal injury, property damage or any other type of
resulting damage, if applicable, shall be reasonably mitigated to the extent possible.
3. At its discretion, the Company may inspect products either at its facilities or in the
eld, and after determination of a warranty claim, will, at its option, repair or replace
defective parts. Repaired or replaced parts will be returned freight prepaid by
the Company.
4. This warranty policy does not cover any labor or shipping charges. The Company
shall not be liable for any costs or charges attributable to any product testing,
maintenance, installation, repair or removal, or for any tools, supplies, or equipment
needed to install, repair, or remove any product.
III. Limitations Applicable to this Limited Warranty
THIS WARRANTY DOES NOT APPLY TO ANY OF THE FOLLOWING:
1. Brushes, impeller or cam on models with brush-type motors and/or
ex-vane impellers.
2. Any product that is not installed, applied, maintained, and used in accordance with
the Company's published instructions, applicable codes, applicable ordinances and/or
with generally accepted industry standards.
3. Any product that has been subject to misuse, misapplication, neglect, alteration,
accident, abuse, tampering, acts of God (including lightning), acts of terrorism, acts
of war, re, improper storage or installation, improper use, improper maintenance or
repair, damage or casualty, or to an excess of the recommended maximums as set
forth in the product instructions.
4. Any product that is operated with any accessory, equipment, component, or part not
specically approved by the Company.
5. Use of replacement parts not sold by the Company, the unauthorized addition of non-
Company products to other Company products, and the unauthorized alteration of
Company products.
6. Products damaged by normal wear and tear, normal maintenance services and
the parts used in connection with such service, or any other conditions beyond the
control of the Company.
7. Any product that has been used for purposes other than those for which it was
designed and manufactured.
8. Any use of the product where installation instructions and/or instructions for use were
not followed.
9. Products connected to voltage other than indicated on nameplate.
10. Products where the pump was exposed to any of the following: sand, gravel, cement,
grease, plaster, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline,
solvents, etc.) or other abrasive or corrosive substances.
11. Products in which the pump has been used for pumping of liquids above 140 °F.
12. Products in which the pump was allowed to operate dry (uid supply cut off).
13. Products in which the sealed motor housing has been opened or the product has
been otherwise dismantled by customer.
14. Products in which the cord has been cut to a length of less than three feet.
The Company reserves the right at any time, and from time to time, to make changes in
the design and/or improvements upon its product without thereby imposing any obligation
upon itself to make corresponding changes or improvements in or upon its products already
manufactured and/or previously sold. The Company further reserves the right to substitute
parts or components of substantially equal quality in any warranty service required by
operation of this Limited Warranty.
This written Limited Warranty is the entire warranty authorized and offered by the Company.
There are no warranties or representations beyond those expressed in this document.
THIS WARRANTY AND REMEDY IS IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES
INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND/OR FITNESS
FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY SPECIFICALLY DISCLAIMED AND
EXPRESSLY EXCLUDED. CORRECTION OF NON-CONFORMITIES, IN THE MANNER AND
FOR THE PERIOD OF TIME AS SET FORTH ABOVE, SHALL CONSTITUTE FULFILLMENT OF
ALL LIABILITY OF THE COMPANY TO THE PURCHASER WHETHER BASED ON CONTRACT,
NEGLIGENCE, OR OTHERWISE.
THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES SUCH
AS, BUT NOT LIMITED TO:
DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT, LOSS OF USE OF EQUIPMENT, FACILITIES
OR SERVICE, LOSS OF PROFIT OR SALES, COST OF PURCHASES OR REPLACEMENT GOODS, CLAIMS OF
CUSTOMERS OF THE PURCHASER, FAILURE TO WARN AND/OR INSTRUCT, LOSS OF OTHER PRODUCTS,
OR COSTS OF ENVIRONMENTAL REMEDIATION, OR DIMINUTION IN PROPERTY VALUE. THE REMEDIES
OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE, AND THE LIABILITY OF THE COMPANY SHALL
NOT, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED THE PRICE OF THE PRODUCTS UPON WHICH
SUCH LIABILITY IS BASED. DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY
MITIGATED TO THE EXTENT POSSIBLE. THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES
RESULTING FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND (1) DEFECTS IN PRODUCT
PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION,
CIRCULATED AND SOLD BY THE COMPANY, AND/OR (2) DEFECTS THAT WERE NOT FOUND AT THE TIME
OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS.
This Limited Warranty gives you specic legal rights. You may have other rights, which vary according to the
applicable laws and regulations. Where any term of this warranty is prohibited by such laws, it shall be null
and void, but the remainder of this warranty shall remain in full force and effect.
DISCLAIMER: Any oral statements about the product made by the seller, the Company,
the representatives or any other parties, do not constitute warranties, shall not be relied upon
by the user, and are not part of the contract for sale. Seller’s and the Company’s only obligation,
and buyer’s only remedy, shall be the replacement and/or repair by the Company of the product
as described above. Before using, the user shall determine the suitability of the product for his
intended use, and user assumes all risk and liability whatsoever in connection therewith.
Form 998913
Rev. 0
05.15
For technical assistance, please contact................. 800.701.7894
Pour l’aide technique, entrez s’il vous plaît en contact ..... 800.701.7894
Para la ayuda técnica, por favor póngase en contacto...... 800.701.7894
www.littlegiant.com
Franklin Electric Co., Inc.
Oklahoma City, OK 73157-2010
Phone: 1.800.701.7894
Fax: 1.405.228.1561
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Little GIANT 6EC-CIM Installation guide

Category
Water pumps
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI