Danfoss JS6000 User guide

Type
User guide
CONNECTOR MATES
WITH DEUTCH
CONNECTOR #DTM-06-125A
PIN #1
INDICATED
1
12
6
7
47.1 mm
[1.85]
51.6 mm
[2.03]
LED INDICATOR
LIGHTS
CONNECTOR MATES
WITH DEUTCH
CONNECTOR #DTM-06-125A
1
12
6
7
97.0 mm
[3.82]
142.0 mm
[5.59]
144.5 mm
5.69
158.2 mm
6.23
2x 25.2 mm
[1.0]
2x
7.0
[.28]
MOUNTING
DIRECTION
#2
COMPLIANT
TM
PLUS+1™ GUIDE
Software
PLUS+1 Compliant
JS7000 Joystick with
CAN Function Block
User Manual
JS7000_CAN
PVEP
Pressure
OnOffOn CDP
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
2
L1117587
Rev AA
May 2011
About this Manual
Organization
and Headings
T
o help you quickly find information in this manual, the material is divided into sections,
topics, subtopics, and details, with descriptive headings set in red type. Section titles
appear at the top of every page in large red type.
In the PDF version of this document, clicking an item underlined in blue italic type
jumps
you to the referenced page in the document.
Special Text Formatting Controls and indicators are set in bold black type.
Table o
f
Contents
A Table of Contents (TOC) appears on the next page. In the PDF version of this document,
the TOC entries are hyperlinked.
Revision History
Revision Date Comment
Rev AA May 2011
©2011 Sauer-Danfoss. All rights reserved.
Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material.
Sauer-Danfoss reserves the right to alter its products without prior notice. This also applies to products already
ordered provided that such alterations can be made without affecting agreed specifications.
All trademarks in this material are properties of their respective owners.
PLUS+1, GUIDE, and Sauer-Danfoss are trademarks of the Sauer-Danfoss Group. The PLUS+1 GUIDE, PLUS+1
Compliant, and Sauer-Danfoss logotypes are trademarks of the Sauer-Danfoss Group.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
L1117587
Rev AA
May 2011
3
Contents
JS7000_CAN Function Block ........................................................................................................................ 4
Overview .................................................................................................................................................... 4
Function Block Inputs ............................................................................................................................ 4
Function Block Outputs ......................................................................................................................... 5
Status and Fault Logic............................................................................................................................ 9
Boolean Output Signals ................................................................................................................ 9
Proportional Output Signals ........................................................................................................ 9
Connections and Signals Overview ................................................................................................. 10
Configuration of Input and Output Buses .................................................................................... 10
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
4
L1117587
Rev AA
May 2011
JS7000_CAN Function Block
Overview
The JS
7000_CAN function block configures the output of a Sauer-Danfoss JS7000 Joystick
with CAN.
This joystick has a CAN (Controller Area Network) 2.0B output that uses the J1939
communication protocol.
The JS7000 Joystick with CAN is a highly configurable joystick that has:
A joystick base with a single three-point y axis or with three-point x and y axes.
Up to two grip-mounted proportional three-point rocker switches.
Up to five grip-mounted push-buttons switches.
Also see the Connections and Signals Overview
on page 10.
Function Block Inputs
JS7000_
CAN Function Block Inputs
Input Type Range Description
SA —— —— Specifies the factory-set source address of the joystick.
All source addresses on the same CAN bus must be different. Do not use the same address twice.
The Type code on the joystick label identifies the source address. Typical addresses are J33 (right), J34 (left),
J35 (center), and J36 (auxiliary).
Enter the source address in hexadecimal format as shown in the following examples:
J33 (right) = 0x33
J34 (left) = 0x34
J35 (center) = 0x35
J36 (auxiliary) = 0x36
CAN —— —— Inputs CAN messages from the joystick. Route this bus to the CAN pin on this function block.
CAN messages sent from the joystick to the function block contain information about the availability of joystick
inputs, joystick input faults, and joystick commands.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
L1117587
Rev AA
May 2011
5
Function Block Outputs
JS7000_CAN Function Block Outputs
Output Type Range Description
Status —— —— Outputs a bus that contains the following status signals.
Btn1_NA–Btn12_NA BOOL —— Indicates if an input is available from a grip-mounted push button switch.
T = Not available.
F = Available.
T_Det_NA BOOL —— Indicates if an input from a detent switch on the joystick’s rotational (theta) axis is
available.
T = Not available.
F = Available.
T_NA BOOL —— Indicates if an input from a rotational (theta) axis is available.
T = Not available.
F = Available.
XGrp_Det_NA BOOL —— Indicates if an input from a grip-mounted, x-axis detent switch is available.
T = Not available.
F = Available.
XGrp_NA BOOL —— Indicates if an input from a grip-mounted, x-axis, proportional switch is available.
T = Not available.
F = Available.
X_Det_NA BOOL —— Indicates if an input from a grip-mounted, x-axis, detent switch is available.
T = Not available.
F = Available.
X_NA BOOL —— Indicates if an input from the joystick’s x axis is available.
T = Not available.
F = Available.
YGrp_Det_NA BOOL —— Indicates if an input from a grip-mounted, y-axis detent switch is available.
T = Not available.
F = Available.
YGrp_NA BOOL —— Indicates if an input from a grip-mounted, y-axis, proportional switch is available.
T = Not available.
F = Available.
Y_Det_NA BOOL —— Indicates if an input from a grip-mounted, y-axis, detent switch is available.
T = Not available.
F = Available.
Y_NA BOOL —— Indicates if an input from the joystick’s y axis is available.
T = Not available.
F = Available.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
6
L1117587
Rev AA
May 2011
JS7000_CAN Function Block Outputs
Output Type Range Description
Fault —— —— Outputs a bus that contains the following fault signals.
Btn1_Flt–Btn12_Flt BOOL —— Indicates if the input from a grip-mounted push-button switch has a fault.
T = Fault.
F = No fault.
T_Det_Flt BOOL —— Indicates if the input from a detent switch on the joystick’s rotational (theta) axis has a
fault.
T = Fault.
F = No fault.
T_Flt BOOL —— Indicates if the input from the joystick’s rotational (theta) axis has a fault.
T = Fault.
F = No fault.
TimeOut_BJM BOOL —— Indicates if the function block receives a CAN Rx_BJM (Receive Basic Joystick Message)
within a 100 ms timeout limit.
This message reports joystick x-axis and y-axis positions as well as the state of grip-
mounted button switches.
When this signal is T, the function block sets all Out signals associated with the Rx_BJM
message to either 0 or F. It sets all Fault signals associated with the Rx_BJM message to
T.
When this signal becomes F again, the function block enables all Out signals associated
with the Rx_BJM message. It resets all Fault signals associated with the Rx_BJM message
to F.
T = Message not received within 100 ms limit.
F = Message received within 100 ms limit.
TimeOut_EJM BOOL —— Indicates if the function block receives a CAN Rx_EMJ (Receive Extended Joystick
Message) within a 100 ms timeout limit.
This message reports the position of grip-mounted proportional switches.
When this signal is T, the function block sets all Out signals associated with the Rx_EJM
message to either 0 or F. It sets all Fault signals associated with the Rx_EJM message to
T.
When this signal becomes F again, the function block enables all Out signals associated
with the Rx_EJM message. It resets all Fault signals associated with the Rx_EJM message
to F.
T = Message not received within 100 ms limit.
F = Message received within 100 ms limit.
XGrp_Det_Flt BOOL —— Indicates if the input from a grip-mounted, x-axis detent switch has a fault.
T = Fault.
F = No fault.
XGrp_Flt BOOL —— Indicates if the input from a grip-mounted, y-axis proportional switch has a fault.
T = Fault.
F = No fault.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
L1117587
Rev AA
May 2011
7
JS7000_CAN Function Block Outputs
Output Type Range Description
X_Det_Flt BOOL —— Indicates if the input from a detent switch on the joystick’s x axis has a fault.
T = Fault.
F = No fault.
X_Flt BOOL —— Indicates if the input from the joystick’s x axis has a fault.
T = Fault.
F = No fault.
YGrp_Det_Flt BOOL —— Indicates if the input from a detent switch on the joystick’s y axis has a fault.
T = Fault.
F = No fault.
YGrp_Flt BOOL —— Indicates if the input from a grip-mounted, y-axis proportional switch has a fault.
T = Fault.
F = No fault.
Y_Det_Flt BOOL —— Indicates if the input from a detent switch on the joystick’s y axis has a fault.
T = Fault.
F = No fault.
Y_Flt BOOL —— Indicates if the input from the joystick’s y axis has a fault.
T = Fault.
F = No fault.
Out —— —— Outputs a bus that contains the following command signals. These signals indicate the
position of each joystick axis and the state of push-button and detent switches.
Btn1–Btn12 BOOL —— Indicates the states of grip-mounted push-button switches.
T = Closed.
F = Open.
Rx_BJM BOOL —— Indicates when the function block receives a CAN Rx_BJM (Receive Basic Joystick
Message).
This message reports joystick x-axis and y-axis positions as well as the state of grip-
mounted button switches.
T = Message received.
F = Message not received.
Rx_EJM BOOL —— Indicates when the function block receives a CAN Rx_EMJ (Receive Extended Joystick
Message).
This message reports the position of grip-mounted proportional switches.
T = Message received.
F = Message not received.
T_Axis_Det BOOL —— Indicates the state of a detent switch on the joystick’s rotational (theta) axis.
T = Closed.
F = Open.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
8
L1117587
Rev AA
May 2011
JS7000_CAN Function Block Outputs
Output Type Range Description
T_Axis_Psn S16 -10000 to +10000 Indicates the position of the joystick’s rotational (theta) axis.
-10000 = -100%
+10000 = +100%
XGrp_Det BOOL —— Indicates the state of a detent switch on a grip-mounted, x-axis proportional switch.
T = Closed.
F = Open.
X_Grp_Psn S16 -10000 to +10000 Indicates the position of a grip-mounted, x-axis proportional switch.
-10000 = -100%
+10000 = +100%
X_Axis_Det BOOL —— Indicates the state of a detent switch on the joystick’s x-axis.
T = Closed.
F = Open.
X_Axis_Psn S16 -10000 to +10000 Indicates the position of the joystick’s x axis.
-10000 = -100%
+10000 = +100%
YGrp_Det BOOL —— Indicates the state of a detent switch on a grip-mounted, y-axis proportional switch.
T = Closed.
F = Open.
YGrp_Psn S16 -10000 to +10000 Indicates the position of a grip-mounted, y-axis proportional switch.
-10000 = -100%
+10000 = +100%
Y_Axis_Det BOOL —— Indicates the state of a detent switch on the joystick’s y-axis.
T = Closed.
F = Open.
Y_Axis_Psn S16 -10000 to +10000 Indicates the position of the joystick’s y axis.
-10000 = -100%
+10000 = +100%
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
L1117587
Rev AA
May 2011
9
Status and Fault Logic
Boolean Output Signals
The f
ollowing table shows how the changing states of the Status and Fault signals affect
the value of Boolean output signals.
Status and Fault Logic—Boolean Output Signals
Output Signal Status Signal State Fault Signal State Output Signal Value
Btn1–Btn12, Rx_BJM, Rx_EJM, T_Axis_Det, XGrp_Det, X_Axis_Det,
YGrp_Det, Y_Axis_Det
F F T or F
T T F
T F F
F T F
For example:
As long as the Status signal and the Fault signal for the Btn1 input are both F, the
Btn1 output signal can be either T or F.
As soon as either the Status signal or the Fault signal for the Btn1 input becomes T,
the Btn1 output signal goes to and stays F.
When the Status signal and the Fault signal for the Btn1 input are again both F, the
Btn1 output signal returns to its normal T or F operation.
Proportional Output Signals
The f
ollowing table shows how the changing states of the Status and Fault signals affect
the value of proportional output signals.
Status
A
nd Fault Log
i
c—Proportional Output Signals
Output Signal Status Signal State Fault Signal State Output Signal Value
T_Axis_Psn, X_Grp_Psn, X_Axis_Psn, YGrp_Psn, Y_Axis_Psn F F -10000 to +10000
T T 0
T F 0
F T 0
For example:
As long as the Status signal and the Fault signal for the T_Axis_Psn input are both F,
the T_Axis_Psn output signal ranges from -10000 to +10000.
As soon as either the Status signal or the Fault signal for the T_Axis_Psn input
becomes T, the T_Axis_Psn output signal goes to and stays at 0.
When the Status signal and the Fault signal for the T_Axis_Psn input are again both
F, the T_Axis_Psn output signal returns to its normal -10000 to +10000 operation.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
JS7000_CAN Function Block
10
L1117587
Rev AA
May 2011
Connections and Signals Overview
Configuration of Input and Output Buses
You do not ha
ve to change the configuration of either input or output buses to use the
JS7000_CAN function block.
PLUS+1 Compliant JS7000 Joystick with CAN Function Block
User Manual
(This page is intentionally blank.)
Products we offer:
Bent Axis Motors
Closed Circuit Axial Piston Pumps
and Motors
Displays
Electrohydraulic Power Steering
Electrohydraulics
Hydraulic Power Steering
Integrated Systems
Joysticks and Control Handles
Microcontrollers and Software
Open Circuit Axial Piston Pumps
Orbital Motors
PLUS+1™ GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Local address:
Sauer-Danfoss Inc.
3500 Annapolis Lane North
Minneapolis, MN 55447, USA
Phone: +1 763 509-2000
Fax: +1 763 559-5769
Sauer-Danfoss (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239-6000
Fax: +1 515 239-6618
Sauer-Danfoss ApS
DK-6430 Nordborg, Denmark
Phone: +45 7488 4444
Fax: +45 7488 4400
Sauer-Danfoss GmbH & Co. OHG
Postfach 2460, D-24531 Neumünster
Krokamp 35, D-24539 Neumünster,
Germany
Phone: +49 4321 871-0
Fax: +49 4321 871 122
Sauer-Danfoss-Daikin LTD
Shin-Osaka TERASAKI 3rd Bldg. 6F
1-5-28 Nishimiyahara, Yodogawa-ku
Osaka 532-0004, Japan
Phone: +81 6 6395 6066
Fax: +81 6 6395 8585
www.sauer-danfoss.com
L1117587
Rev AA
Month 2011
Members of the Sauer-Danfoss Group:
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller-inverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Sauer-Danfoss-Daikin
www.sauer-danfoss-daikin.com
Sauer-Danfoss is a global manufacturer and supplier of high-
quality hydraulic and electronic components. We specialize in
providing state-of-the-art technology and solutions that excel in
the harsh operating conditions of the mobile off-highway market.
Building on our extensive applications expertise, we work closely
with our customers to ensure exceptional performance for a broad
range of off-highway vehicles.
We help OEMs around the world speed up system development,
reduce costs and bring vehicles to market faster.
Sauer-Danfoss—Your Strongest Partner in Mobile Hydraulics.
Go to www.sauer-danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Sauer-Danfoss.
We offer expert worldwide support for our customers, ensuring the
best possible solutions for outstanding performance. And with an
extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.
Please contact the Sauer-Danfoss re
p
resentative nearest
y
ou.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss JS6000 User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI