Danfoss H1 B User guide

Type
User guide
Electrical Installation
P1, P2 Electric Two-Position Controls with
Proportional PCOR
for H1B Bent Axis Motors
www.danfoss.com
Revision history Table of revisions
Date Changed Rev
September 2018 G1,G2 Servo Supply Options added to MC. 0302
September 2018 Major update. 0301
September 2015 Converted to Danfosss layout. 0201
July 2009 First edition. 0101
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
2 |
©
Danfoss | September 2018 BC00000278en-000302
Product overview
Electric two-position with proportional PCOR.......................................................................................................................4
Nomenclature....................................................................................................................................................................................4
P1DA and P2DA options with PCOR..........................................................................................................................................5
P1D1 and P2D2 options with PCOR and electric BPD.........................................................................................................6
P1G1 and P2G2 options with PCOR and electric BPD......................................................................................................... 8
Latest version of technical literature.........................................................................................................................................9
Electrical installation
2-pin DEUTSCH connector pinout........................................................................................................................................... 10
Pin compatibility............................................................................................................................................................................ 10
Mating connector parts list ....................................................................................................................................................... 10
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Contents
©
Danfoss | September 2018 BC00000278en-000302 | 3
Electric two-position with proportional PCOR
The PPCOR valve consists of an electric proportional solenoid and a two-position, three-way porting
spool with an adjustable spring force on the opposite end of the spool. Maximum signal current to the
proportional solenoid overrides the pressure compensator and strokes the motor to maximum
displacement. The proportional solenoid changes the pressure compensator setting to allow different, on
the go, settings.
The solenoid and the high system pressure work against the spring on the end of the two-position, three-
way porting spool. With decreased signal current on the proportional solenoid, the reduction of the
forces from the proportional solenoid cause an increased pressure compensator setting for the high
system pressure and consequently provides a proportional pressure compensator.
During production test, the PPCOR setting is adjusted to 240 bar with the adjusting screw on the control
housing in reference to input current of:
800 mA for P1 (12 V)
400 mA for P2 (24 V)
Nomenclature
A B C D E F G H J K L M N P
H1 B
A
Q R
Z
A
N N N
B – Control Options
Code Description
P1 Electric two-position control with electric proportional PCOR, 12 V,
de-energized = minimum displacement, DEUTSCH DT 04-2P connector
P2 Electric two-position control with electric proportional PCOR, 24 V,
de-energized = minimum displacement, DEUTSCH DT 04-2P connector
C – Servo Supply Options
Code Description
DA Without brake pressure defeat (BPD)
D1 With BPD 12 V, de-energized BPD = PCOR active at port A, DEUTSCH DT 04-2P connector
D2 With BPD 24 V, de-energized BPD = PCOR active at port A, DEUTSCH DT 04-2P connector
G1 With BPD 12 V, de-energized BPD = PCOR active at port B, DEUTSCH DT 04-2P connector
G2 With BPD 24 V, de-energized BPD = PCOR active at port B, DEUTSCH DT 04-2P connector
Only certain control options for the H1B motor use this electric two-position control. Please refer to the
motor’s nomenclature to determine if the motor is equipped with the proper option. You can find the
nomenclature on the motor’s nametag. For nomenclature details, refer to H1B Bent Axis Variable
Displacement Motors Technical Information, BC00000043.
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
4 |
©
Danfoss | September 2018 BC00000278en-000302
P1DA and P2DA options with PCOR
P1 – electric two-position control 12 V, de-energized = minimum displacement with electric
proportional PCOR 12 V
P2 – electric two-position control 24 V, de-energized = minimum displacement with electric
proportional PCOR 24 V
DA – with electric proportional PCOR, without Brake Pressure Defeat
W
Warning
This control is not for use in propel applications.
A
B
max
min
M4
L1
L2
N
P003456
n
MA
M5 MB
C6
A, B Main pressure lines
L1, L2 Drain lines
M4, M5 Gauge port servo pressure
MA, MB Gauge port system pressure
N Speed sensor (optional)
Options P1DA, P2DA
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
PCOR pressure (bar) versus Input command (mA)
0
50
100
150
200
250
240*
300
350
0 200 400 600 800 1000 1200 1400 1600
P003 485
bar
P1
P2
mA
Maximum PCOR setting = 300 bar [4351 psi], * Production test setting = 240 bar
C
Caution
If the signal to the PPCOR is lost or drops below the range shown in the chart, the PCOR setting will
potentially increase to pressure levels above the recommended application limits or the regulated
pressure control of the pump, and in effect, disable the PCOR function.
The PCOR pressure level can be proportionally changed with the input current to the solenoid.
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
©
Danfoss | September 2018 BC00000278en-000302 | 5
Formulas to calculate pressure level dependent on input current
Voltage All sizes (mA) Variables:
12 V I
PCOR
= – 2.724 x P
PCOR
+ 1453.8
P
PCOR
= PCOR pressure level (bar)
I
PCOR
= Current input to proportional PCOR solenoid (mA)
24 V I
PCOR
= – 1.399 x P
PCOR
+ 735.7
Proportional control solenoid data C6
Description 12 V 24 V
Maximum current 1800 mA 920 mA
Nominal coil resistance @ 20 °C [68 °F] 3.66 Ω 14.20 Ω
@ 80 °C [176 °F] 4.52 Ω 17.52 Ω
Inductance 33 mH 140 mH
PWM signal frequency Range 70 – 200 Hz
Recommended
*
150 Hz
IP Rating IEC 60 529 IP 67
DIN 40 050, part 9 IP 69K with mating connector
Connector color Black
*
PWM signal required for optimum control performance.
P1D1 and P2D2 options with PCOR and electric BPD
P1 – electric prop. 12 V, de-energized = minimum displacement with electric prop. PCOR 12 V
D1 – with electric propor. PCOR, with electric BPD 12 V, de-energized BPD = PCOR active at port A
P2 – electric prop. 24 V, de-energized = minimum displacement with electric prop. PCOR 24 V
D2 – with electric propor. PCOR, with electric BPD 24 V, de-energized BPD = PCOR active at port A
Hydraulic schematic
A
B
n
min
max
C5
C6
M4 MB
M5
P003436
L1
L1
NMA
A, B Main pressure lines
L1, L2 Drain lines
M4, M5 Gauge port servo pressure
MA, MB Gauge port system pressure
N Speed sensor (optional)
Options P1D1, P2D2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
6 |
©
Danfoss | September 2018 BC00000278en-000302
PCOR pressure (bar) versus Input command (mA)
0
50
100
150
200
250
240*
300
350
0 200 400 600 800 1000 1200 1400 1600
P003 485
bar
P1
P2
mA
Maximum PCOR setting = 300 bar [4351 psi], * Production test setting = 240 bar
C
Caution
If the signal to the PPCOR is lost or drops below the range shown in the chart, the PCOR setting will
potentially increase to pressure levels above the recommended application limits or the regulated
pressure control of the pump, and in effect, disable the PCOR function.
The PCOR pressure level can be proportionally changed with the input current to the solenoid.
For formulas to calculate pressure level dependent on input current please see P1DA and P2DA options
with PCOR on page 5.
Two-position solenoid data C5 (Brake pressure defeat)
Description 12 V 24 V
Supply voltage Minimum 9.5 V
DC
19 V
DC
Max. (continuous) 14.6 V
DC
29 V
DC
Nominal coil resistance @ 20 °C [68 °F] 8.4 Ω 34.5 Ω
Input current Recommended 1050 mA 500 mA
IP Rating IEC 60 529 IP 67
DIN 40 050, part 9 IP 69K with mating connector
Bi-directional diode yes
Connector color Black
Proportional control solenoid data C6
Description 12 V 24 V
Maximum current 1800 mA 920 mA
Nominal coil resistance @ 20 °C [68 °F] 3.66 Ω 14.20 Ω
@ 80 °C [176 °F] 4.52 Ω 17.52 Ω
Inductance 33 mH 140 mH
PWM signal frequency Range 70 – 200 Hz
Recommended
*
150 Hz
IP Rating IEC 60 529 IP 67
DIN 40 050, part 9 IP 69K with mating connector
Connector color Black
*
PWM signal required for optimum control performance.
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
©
Danfoss | September 2018 BC00000278en-000302 | 7
P1G1 and P2G2 options with PCOR and electric BPD
P1 – electric prop. 12V / de-energized = min. displacement with electric prop. PCOR 12V
G1 – with electric propor. PCOR / with electric BPD 12V, de-energized BPD = PCOR active at port B
P2 – electric prop. 24V / de-energized = min. displacement with electric prop. PCOR 24V
G2 – with electric propor. PCOR / with electric BPD 24V, de-energized BPD = PCOR active at port B
Hydraulic schematic
A
B
n
min
max
C5
C6
M4
MB
M5
P006 067
L1
L2
NMA
A, B Main pressure lines
L1, L2 Drain lines
M4, M5 Gauge port servo pressure
MA, MB Gauge port system pressure
N Speed sensor (optional)
Options P1G1, P2G2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
PCOR pressure (bar) versus Input command (mA)
0
50
100
150
200
250
240*
300
350
0 200 400 600 800 1000 1200 1400 1600
P003 485
bar
P1
P2
mA
Maximum PCOR setting = 300 bar [4351 psi], * Production test setting = 240 bar
C
Caution
If the signal to the PPCOR is lost or drops below the range shown in the chart, the PCOR setting will
potentially increase to pressure levels above the recommended application limits or the regulated
pressure control of the pump, and in effect, disable the PCOR function.
The PCOR pressure level can be proportionally changed with the input current to the solenoid.
For formulas to calculate pressure level dependent on input current please see P1DA and P2DA options
with PCOR on page 5.
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
8 |
©
Danfoss | September 2018 BC00000278en-000302
Two-position solenoid data C5 (Brake pressure defeat)
Description 12 V 24 V
Supply voltage Minimum 9.5 V
DC
19 V
DC
Max. (continuous) 14.6 V
DC
29 V
DC
Nominal coil resistance @ 20 °C [68 °F] 8.4 Ω 34.5 Ω
Input current Recommended 1050 mA 500 mA
IP Rating IEC 60 529 IP 67
DIN 40 050, part 9 IP 69K with mating connector
Bi-directional diode yes
Connector color Black
Proportional control solenoid data C6
Description 12 V 24 V
Maximum current 1800 mA 920 mA
Nominal coil resistance @ 20 °C [68 °F] 3.66 Ω 14.20 Ω
@ 80 °C [176 °F] 4.52 Ω 17.52 Ω
Inductance 33 mH 140 mH
PWM signal frequency Range 70 – 200 Hz
Recommended
*
150 Hz
IP Rating IEC 60 529 IP 67
DIN 40 050, part 9 IP 69K with mating connector
Connector color Black
*
PWM signal required for optimum control performance.
Latest version of technical literature
Danfoss product literature is online at: https://www.danfoss.com/en/search/
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Product overview
©
Danfoss | September 2018 BC00000278en-000302 | 9
2-pin DEUTSCH connector pinout
1 2
1. Voltage signal
2. Ground
Alternative pinout:
1. Ground
2. Voltage signal
Pin compatibility
PLUS+1
®
module pin type/ H1B P pin compatibility
Pin Function
1, 2 PWMOUT/DOUT/PVG Power supply
1, 2 PWMOUT/DOUT/PVGOUT
1, 2 Power ground
PLUS+1
®
module pin type/ H1B D1, D2 EBPD pin compatibility
Pin Function
1, 2 PWMOUT/DOUT/PVG Power supply
1, 2 PWMOUT/DOUT/PVGOUT
1, 2 Power ground
Mating connector parts list
Connector ordering data
Description Quantity Ordering number
Mating connector 1 DEUTSCH DT06-2S
Wedge lock 1 DEUTSCH W2S
Socket contact (16 and 18 AWG) 2 DEUTSCH 0462-201-16141
Danfoss mating connector kit 1 K29657
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
Electrical installation
10 |
©
Danfoss | September 2018 BC00000278en-000302
Electrical Installation
P1, P2 Electric Two-Position Controls for H1B Motors
©
Danfoss | September 2018 BC00000278en-000302 | 11
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©
Danfoss | September 2018 BC00000278en-000302
Products we offer:
DCV directional control
valves
Electric converters
Electric machines
Electric motors
Hydrostatic motors
Hydrostatic pumps
Orbital motors
PLUS+1
®
controllers
PLUS+1
®
displays
PLUS+1
®
joysticks and
pedals
PLUS+1
®
operator
interfaces
PLUS+1
®
sensors
PLUS+1
®
software
PLUS+1
®
software services,
support and training
Position controls and
sensors
PVG proportional valves
Steering components and
systems
Telematics
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
  • Page 1 1
  • Page 2 2
  • Page 3 3