Aeroflex IFR 6015 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Aeroflex IFR 6015 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
T es t Set
Operation Manual
IFR 6015
TCAS/ADS-B/TIS
XPDR/DME
EXPORT CONTROL WARNING: This document contains controlled technical data under the
jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be
transferred to any foreign third party without the specific prior approval of the U.S. Department of
Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable
by fine, imprisonment, or both.
Subject to Export Control, see Cover Page for details.
OPERATION MANUAL
XPDR/TACAN/TCAS/ADS-B/TIS
TEST SET
IFR 6015
PUBLISHED BY
Aeroflex
COPYRIGHT Aeroflex 2016
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise without the prior permission of the publisher.
Original Printing Mar 2005
Issue 2 Dec 2007
Issue 3 Dec 2008
Issue 4 Jan 2010
Issue 5 Nov 2010
Issue 6 Oct 2012
Issue 7 Jun 2013
Issue 8 Aug 2015
Issue 9 Jan 2016
Issue 10 Oct 2016
10200 West York / Wichita, Kansas 67215 U.S.A. / (316) 522-4981 / FAX (316) 524-2623
Subject to Export Control, see Cover Page for details.
OPERATION MANUAL
IFR 6015
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
Cable Statement:
For continued EMC compliance, all external cables must be double shielded.
For continued EMC compliance, all external cables must be 3 meters or less in length.
Nomenclature Statement:
In this manual Test Set or Unit refers to the IFR 6015 XPDR/TACAN/TCAS/ADS-B/TIS Test Set.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
SAFETY FIRST: TO ALL OPERATIONS PERSONNEL
REFER ALL SERVICING OF UNIT TO QUALIFIED TECHNICAL PERSONNEL. THIS UNIT CONTAINS NO
OPERATOR SERVICEABLE PARTS.
WARNING: USING THIS EQUIPMENT IN A MANNER NOT SPECIFIED BY THE ACCOMPANYING
DOCUMENTATION MAY IMPAIR THE SAFETY PROTECTION PROVIDED BY THE EQUIPMENT.
CASE, COVER OR PANEL REMOVAL
Opening the Case Assembly exposes the operator to electrical hazards that can result in electrical shock or
equipment damage. Do not operate this Test Set with the Case Assembly open.
SAFETY IDENTIFICATION IN TECHNICAL MANUAL
This manual uses the following terms to draw attention to possible safety hazards, that may exist when
operating or servicing this equipment.
CAUTION: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN
EQUIPMENT OR PROPERTY DAMAGE (E.G., FIRE).
WARNING: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN
PERSONAL INJURY OR DEATH.
SAFETY SYMBOLS IN MANUALS AND ON UNITS
CAUTION: Refer to accompanying documents. (This symbol refers to
specific CAUTIONS represented on the unit and clarified in the text.)
AC OR DC TERMINAL: Terminal that may supply or be supplied with AC or
DC voltage.
DC TERMINAL: Terminal that may supply or be supplied with DC voltage.
AC TERMINAL: Terminal that may supply or be supplied with AC or
alternating voltage.
EQUIPMENT GROUNDING PRECAUTION
Improper grounding of equipment can result in electrical shock.
USE OF PROBES
Check the specifications for the maximum voltage, current and power ratings of any connector on the Test
Set before connecting it with a probe from a terminal device. Be sure the terminal device performs within
these specifications before using it for measurement, to prevent electrical shock or damage to the
equipment.
POWER CORDS
Power cords must not be frayed, broken nor expose bare wiring when operating this equipment.
USE RECOMMENDED FUSES ONLY
Use only fuses specifically recommended for the equipment at the specified current and voltage ratings.
INTERNAL BATTERY
This unit contains a Lithium Ion Battery, serviceable only by a qualified technician.
CAUTION: SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TO
COMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTION
AND INTERFERENCE TO COMMUNICATION SERVICES OUT TO A DISTANCE OF SEVERAL
MILES. USERS OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTS
IN RADIATION OF A SIGNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARY
PRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
DECLARATION OF CONFORMITY
The Declaration of Conformity Certificate included with
the Unit should remain with the Unit.
Aeroflex recommends the operator reproduce a copy
of the Declaration of Conformity Certificate to be
stored with the Operation Manual for future reference.
OPERATION MANUAL
IFR 6015
Subject to Export Control, see Cover Page for details.
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
TABLE OF CONTENTS
Subject to Export Control, see Cover Page for details. Page 1
Oct 1/16
TABLE OF CONTENTS
Title Chapter/Section
Title Page / Copyright Page
Statements
Safety Page
Declaration of Conformity
Table of Contents
Introduction
Service Upon Receipt of Material
Chapter 1
Section 1 - Description and Quick Start 1-1
Section 2 - Operation 1-2
Section 3 - Specifications 1-3
Section 4 - Shipping 1-4
Section 5 - Storage 1-5
Appendix A - Connector Pin-Out Tables
Appendix B - Metric/British Imperial Conversion Table with Nautical Distance Conversions
Appendix C - Factory/Power Up Presets
Appendix D - Abbreviations
Appendix E - Breakout Box
Appendix F - Transponder Configurations
Appendix G - Mode S Address Blocks (Product Specific List)
Appendix H - Mode S Address Blocks (Complete List)
Appendix I - Signal Formats
Appendix J - Standard Accessories
Appendix K - Target Acquisition Time Probability Table
Index
Battery/Fuse Instructions
OPERATION MANUAL
IFR 6015
TABLE OF CONTENTS
Subject to Export Control, see Cover Page for details. Page 2
Oct 1/16
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
INTRODUCTION
Subject to Export Control, see Cover Page for details. Page 1
Oct 1/16
INTRODUCTION
This manual contains operating instructions for the IFR 6015. It is strongly recommended that
personnel be thoroughly familiar with the contents of this manual before attempting to operate this
equipment.
Refer all servicing of unit to qualified technical personnel.
ORGANIZATION
This manual is divided into the following Chapters and Sections:
CHAPTER 1 - OPERATION
Section 1 - DESCRIPTION and Quick Start (for operators familiar with avionics systems)
Section 2 - OPERATION (installation, description of controls, connectors and indicators,
performance evaluation and operating procedures)
Section 3 - SPECIFICATIONS
Section 4 - SHIPPING
Section 5 - STORAGE
OPERATION MANUAL
IFR 6015
INTRODUCTION
Subject to Export Control, see Cover Page for details. Page 2
Oct 1/16
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
1-TABLE OF CONTENTS
Subject to Export Control, see Cover Page for details. Page 1
Oct 1/16
CHAPTER ONE
IFR 6015 XPDR/TACAN/TCAS/ADS-B/TIS TEST SET
OPERATION MANUAL
TABLE OF CONTENTS
Title Chapter/Section/Subject Page
SECTION 1 - DESCRIPTION 1-1
1. General Description and Capabilities 1-1-1 1
1.1 Description 1-1-1 1
1.2 Functional Capabilities 1-1-1 1
1.3 Regulatory Responsibilities 1-1-1 2
2. Quick Start 1-1-2 1
2.1 Controls 1-1-2 1
2.2 General Setup 1-1-2 2
2.3 XPDR Setup Over the Air 1-1-2 2
2.4 XPDR Setup Direct Connect 1-1-2 4
2.5 Antenna Coupler Connect 1-1-2 5
2.6 XPDR Testing 1-1-2 5
2.6.1 ADS-B/GICB Testing 1-1-2 6
2.6.2 ADS-B MON 1-1-2 7
2.6.3 ADS-B GEN 1-1-2 8
2.6.4 GICB 1-1-2 8
2.6.5 Advisory Circular 1-1-2 9
2.7 TACAN Setup Antenna 1-1-2 9
2.8 TACAN Setup Direct Connect 1-1-2 9
2.9 TACAN Testing 1-1-2 10
2.10 TCAS Setup Antenna 1-1-2 10
2.11 TCAS Testing 1-1-2 11
2.12 TIS Setup Antenna 1-1-2 12
2.13 TIS Setup Direct Connect 1-1-2 13
2.14 TIS Testing 1-1-2 14
SECTION 2 - OPERATION 1-2
1. Installation 1-2-1 1
1.1 General 1-2-1 1
1.2 Battery Operation 1-2-1 1
1.3 Battery Charging 1-2-1 1
1.4 Safety Precautions 1-2-1 1
1.4.1 Complying with Instructions 1-2-1 1
1.4.2 Grounding Power Cord 1-2-1 1
1.4.3 Operating Safety 1-2-1 1
1.5 AC Power Requirements 1-2-1 2
1.6 Battery Recharging 1-2-1 2
1.7 External Cleaning 1-2-1 3
2. Controls, Connectors and Indicators 1-2-2 1
3. Performance Evaluation 1-2-3 1
3.1 General 1-2-3 1
3.2 Self Test 1-2-3 1
4. Operating Procedures 1-2-4 1
4.1 General 1-2-4 1
4.2 Start-Up 1-2-4 2
OPERATION MANUAL
IFR 6015
1-TABLE OF CONTENTS
Subject to Export Control, see Cover Page for details. Page 2
Oct 1/16
TABLE OF CONTENTS (cont)
Title Chapter/Section/Subject Page
SECTION 2 OPERATION (cont) 1-2
4.3 XPDR (Transponder) 1-2-4 2
4.3.1 Configurations 1-2-4 3
4.3.2 Setup 1-2-4 4
4.3.3 Auto Test 1-2-4 8
4.3.4 Test List 1-2-4 11
4.3.5 Altitude Encoder 1-2-4 31
4.3.6 Direct Connect Procedure 1-2-4 32
4.3.7 Antenna Coupler Procedure 1-2-4 33
4.3.8 “Over the Air” Ground Test 1-2-4 34
4.3.9 “Over the Air” Simulated Altitude Test 1-2-4 34
4.4 TACAN 1-2-4 35
4.4.1 DME 1-2-4 35
4.4.2 TACAN 1-2-4 37
4.4.3 TACAN Mode 1-2-4 44
4.4.4 Setup 1-2-4 50
4.5 TCAS Mode 1-2-4 52
4.5.1 TCAS Operation Concept 1-2-4 52
4.5.2 TCAS Testing 1-2-4 55
4.5.3 TCAS Setup 1-2-4 55
4.5.4 TCAS Screen 1-2-4 60
4.5.5 Setup-Scenario Data Screen 1-2-4 63
4.5.6 Monitor Screens 1-2-4 65
4.5.6.1 Surveillance Monitor 1-2-4 65
4.5.6.2 Broadcast Monitor 1-2-4 68
4.5.6.3 ATCRBS 1-2-4 70
4.5.7 Recommended Test Procedure 1-2-4 73
4.5.8 E-TCAS General 1-2-4 75
4.6 ADS-B General 1-2-4 76
4.6.1 ADS-B/GICB Modes 1-2-4 76
4.6.2 Setup ADS-B 1-2-4 76
4.6.3 ADS-B/GICB MAIN 1-2-4 78
4.6.4 ADS-B MON 1-2-4 78
4.6.5 Advisory Circular 1-2-4 96
4.6.6 ADS-B GEN 1-2-4 101
4.6.7 GICB General 1-2-4 116
4.6.8 GICB Mode 1-2-4 116
4.7 TIS General 1-2-4 139
4.7.1 TIS Mode 1-2-4 139
4.7.2 TIS Setup 1-2-4 139
4.8 Directional Antenna 1-2-4 143
4.9 Breakout Box 1-2-4 147
SECTION 3 - SPECIFICATIONS 1-3
SECTION 4 - SHIPPING 1-4
1. Shipping Test Sets 1-4-1 1
1.1 Information 1-4-1 1
1.2 Repacking Procedure 1-4-1 1
SECTION 5 - STORAGE 1-5
OPERATION MANUAL
IFR 6015
1-LIST OF TABLES
Subject to Export Control, see Cover Page for details. Page 1
Oct 1/16
LIST OF ILLUSTRATIONS
Title Chapter/Section/Subject Page
Ramp Testing 1-1-2 3
Battery Recharging 1-2-1 2
IFR 6015 Front Panel 1-2-2 1
Directional Antenna 1-2-2 6
Breakout Box, Front View 1-2-2 6
Breakout Box, Top View 1-2-2 7
Breakout Box, Bottom View 1-2-2 7
Gaussian Pulse Pairs 1-2-4 37
DME Interrogation and Reply 1-2-4 37
TACAN Beacon Antenna 1-2-4 38
TACAN Beacon Antenna Construction 1-2-4 38
Composite TACAN Beacon Signal 1-2-4 39
Airborne Receiver Block Schematic 1-2-4 40
TACAN Pulse Signals 1-2-4 41
AN/ARN-84(V) TACAN Control Panel 1-2-4 42
15 Hz Cardioid Antenna Pattern 1-2-4 43
TACAN T/R Normal Mode Screen 1-2-4 45
TACAN T/R Range Only Screen 1-2-4 45
TACAN T/R Inverse Mode Screen 1-2-4 46
TACAN A/A Beacon Mode Screen 1-2-4 46
TACAN A/A Range Only Mode Screen 1-2-4 47
TACAN A/A Inverse Screen 1-2-4 47
TCAS Protection Volume 1-2-4 52
Typical TCAS II Display 1-2-4 54
Recommended Test Locations 1-2-4 73
TIS Operation Flow Chart 1-2-4 142
Suggested Layout to Reduce Multipath Errors 1-2-4 145
Ramp Testing 1-2-4 146
Repacking Procedure 1-4-1 1
OPERATION MANUAL
IFR 6015
1-LIST OF TABLES
Subject to Export Control, see Cover Page for details. Page 2
Oct 1/16
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
1-LIST OF TABLES
Subject to Export Control, see Cover Page for details. Page 3
Oct 1/16
LIST OF TABLES
Title Chapter/Section/Subject Page
Test Identifier Symbols 1-2-4 9
Common Usage GICB BDS 1-2-4 29
TACAN References Pulses 1-2-4 38
TACAN Test Modes and Signals 1-2-4 44
Protection Volume Parameters Versus Altitude 1-2-4 53
SL: Field Valid Data 1-2-4 57
CA: Field Valid Data 1-2-4 58
RI: Field (Acquisition) Valid Data 1-2-4 58
RI: Field (Tracking) Valid Data 1-2-4 58
RAC: Field Valid Data 1-2-4 58
ARA: Field Valid Data 1-2-4 59
FS: Field Display Data 1-2-4 59
DR: Field Display Data 1-2-4 59
CVC: Field Display Data 1-2-4 66
VRC: Field Display Data 1-2-4 66
CHC: Field Display Data 1-2-4 66
HRC: Field Display Data 1-2-4 66
ESB: Field Display Data 1-2-4 67
PC: Field Display Data 1-2-4 67
RR: Field Display Data 1-2-4 67
DI: Field Display Data 1-2-4 68
ARA=Field Valid Data 1-2-4 69
RAC=Field Valid Data 1-2-4 70
“TYPE” Subfield Code Definitions (DF=17 or 18) 1-2-4 81
“MOVEMENT” Subfield in ADS-B Surface Position Messages 1-2-4 82
Lateral Axis GPS Antenna Offset Encoding 1-2-4 83
Longitudinal Axis GPS Antenna Offset Encoding 1-2-4 83
GICB Supported BDS Registers 1-2-4 117
OPERATION MANUAL
IFR 6015
1-LIST OF TABLES
Subject to Export Control, see Cover Page for details. Page 4
Oct 1/16
THIS PAGE INTENTIONALLY LEFT BLANK.
OPERATION MANUAL
IFR 6015
1-SERVICE UPON RECEIPT OF MATERIALS
Subject to Export Control, see Cover Page for details. Page 1
Oct 1/16
SERVICE UPON RECEIPT OF MATERIAL
Unpacking
Special-design packing material inside this shipping carton provides maximum protection for the
IFR 6015. Avoid damaging the carton and packing material during equipment unpacking. Use the
following steps for unpacking the IFR 6015.
Cut and remove the sealing tape on the carton top and open the carton.
Grasp the IFR 6015 transit case firmly, while restraining the shipping carton, and lift the
equipment and packing material vertically.
Place the IFR 6015 transit case and end cap packing on a suitable flat, clean and dry surface.
Remove the protective plastic bag from the IFR 6015 transit case.
Place protective plastic bag and end cap packing material inside shipping carton.
Store the shipping carton for future use should the IFR 6015 need to be returned.
Checking Unpacked Equipment
Inspect the equipment for damage incurred during shipment. If the equipment has been
damaged, report the damage to Aeroflex.
Check the equipment against the packing slip to see if the shipment is complete. Report all
discrepancies to Aeroflex.
IFR 6015 with Standard Accessories
DESCRIPTION PART NUMBER QTY
IFR 6015 72424 1
Power Supply 67366 1
Antenna 91771 1
Breakout Box 64580 1
Antenna Shield 64749 1
12 IN. Coaxial
Cable (Antenna)
62401 1
72 IN. Coaxial
Cable (Antenna)
112830 1
5 A Fuse 56080 1
Transit Case 10241 1
Power Cord
(US only)
62302 1
POWER CORD
(EUROPEAN)
64020 1
Operation Manual
(CD)
6097 1
Getting Started
Manual (paper)
6100 1
Antenna Coupler and Cable
OPTIONAL
ACCESSORIES
PART NUMBER QTY
Desk Top Stand 63656 1
Tripod 67474 1
Tripod, Dolly,
Stand
82553 1
25 ft TNC/TNC
COAXIAL CABLE
62462 1
50 ft TNC/TNC
COAXIAL CABLE
86336 1
UC-584 Dual
Antenna Coupler
Kit
112349 1
UC-584 Single
Antenna Coupler
Kit
112350 1
Maintenance
Manual (CD)
6095 1
/