2
Tools required
Phillips’s screwdriver/drill – removing top plate, securing
clips, burner, and burner cover.
11 mm wrench – remove the thermocouple from the
bracket.
8 mm or 5/16” wrench to remove the thermocouple
from the valve.
• Shut off the gas supply at the gas line.
• Disconnect the fridge from the gas line and
cap the line for safety reasons.
• With the fridge standing, walk around the
back of the fridge and look towards the
bottom right corner/side for a small silver
box known as the “burner box cover”.
1. Remove the cover, exposing the burner
assembly by unscrewing the Phillips screw.
Proceed to cut the zip tie holding the
thermocouple and gas line together.
2. Use Phillip’s screwdriver to release the
burner from the burner bracket.
3. Use the end of the screwdriver and tap the
burner out of the bracket
4. Using the 11mm wrench, unscrew the
thermocouple nut and remove the
thermocouple from the burner bracket.
5. Now that the thermocouple is removed from
the burner bracket, the next step is to
remove it from the back of the gas valve
located under the top cover panel.
UNIQUE UGP-3 SM Thermocouple
Part # UGP-DL08502311
Unscrew Phillip’s screw to release burner from
burner bracket
Use the end of your screwdriver and tap the burner
out of the burner bracket
Using 11mm wrench. Unscrew the thermocouple nut.
Remember the position of the thermocouple tip
in relation to the slots in the burner tube –
approximately 3 slots in from the left.
Unscrew the Philips screw and take the burner cover
apart by pulling it from bottom and then top