Haier SC-510 User manual

Type
User manual

This manual is also suitable for

Beverage Coole
r
User's Manual
M
ode
l: SC-310/410/510
Safety precautions
When using this appliance, always exercise the following basic safety precautions.
1. Read all of the instructions before using this appliance.
2. Use this appliance only for its intended purpose as described in this User's
Manual.
3.
4. Never unplug your cabinet by pulling on the power cord. Always grasp the
plug firmly and pull straight out from the outlet.
5. Unplug your cabinet before cleaning or making any repairs.
Note: If for any reason this product requires service, we strongly recommend
that a certified technician performs the service.
6. Repair or replace immediately all electric service cords that have become
frayed
or otherwise damaged. Do not use a cord that shows cracks or abrasion damage
along its length, the plug or the connector end.
7. This cabinet should not be recessed or built-in an enclosed cabinet. It is
designed
for freestanding installation only.
8. If your cabinet is to be discarded, we recommend that you remove the door and
leave the shelves in place. This will reduce the possibility of danger to children.
9. Do not operate your cabinet in the presence of explosive fumes.
10. Do not load the freezer with the food before desired temperature has not been
reached to avoid bacteria reproduction.
This cabinet must be properly installed in accordance with the installation
instructions before it is used. See grounding instructions in the installation section.
1
Techn
i
cal data Pack
i
ng l
i
st
T echnical data
Packing list
1
7
Climate
Classification
Net
Capacity L
Voltage
Net Weight
kg
External
Dimensions
mm
Name
Quantity
Model
Shelf Bracket
(left/right)
User's
manual
Shelves
(Flat)
Shelves
(Bottom)
Price
tickets
Please save these instructions.
Danger!
Risk of child entrapment. Before you discard your old cabinet, take off the
doors so that children may not easily climb inside.
Thank you for using our product. This
manual will guide you in getting the
best use of your cabinet.
Remember to record the model and serial
number. They are on a label in
back of the cabinet.
Staple your receipt to your manual. You will need it to obtain warranty
Service
Model number
Serial number
Date of purchase
2
Table of content
Safety precautions...............................................................................................
Features ...............................................................................................................
Technical data Packing list...........................................................................
1
4
5
6
Ambient environment ...............................................................................................................6
Preparation before operation......................................................................................................7
Disassembly of light canopy and instruction.............................................................................7
Startup, operation and temperature adjustment .........................................................................8
Lamp decoration, illumination and switches .............................................................................9
Repair & maintenance for refrigeration cassette .....................................................................10
Cleaning of air intake filter screen...........................................................................................10
Guide on food preservation......................................................................................................11
EMS-55 display .......................................................................................................................12
EMS-55 operation & function .................................................................................................13
EMS-55 Malfunction & Maintenance .....................................................................................14
15
CleaningShutdownQusetions and answers .............................................................................
After-sales service....................................................................................................................
17
Technical data ...........................................................................................................................l7
Packing list................................................................................................................................l7
Parts ..........................................................................................................................................
Instruction ................................................................................................................................
Maintenance ...........................................................................................................................
l5
l6
3
Before abandoning the freezer, please remove the sealing strip, so as to avoid accidents that
are caused by children's entering.
After abandoned, the freezer should be far from fire and delivered to designated site for
treatment.
When abandoning it please remove the door and the lock to avoid possible accidents caused
by children's entering.
After sales service
1
6
Maintenance
Cleaning Shutdown Questions and answers
Cleaning & maintenance
Shutdown
Questions and answers
Please unplug the freezer before cleaning
Please use soft cloth or sponge with water or soap (non-corrosive mild detergent), while
cleaning. After that, please wipe the freezer using dry cloth to keep the freezer from getting
rusty.
Do not sprinkle water to the freezer and do not use hard or steel brushes to clean the freezer
Do not use organic solvents, boiling water, washing powder or acid while cleaning.
If the freezer will be shutdown for a long tome, please unplug first, then clean it as instructions
mentioned above and open glass door to dry inside, then keep it with mothballs
The design and manufacture of the refrigerator is according to national standard.
If there is any question while using, please refer to this operation manual and
determine whether it is caused by improper operation or not.
The following are not malfunction
Phenomena Reasons and solutions
Refrigerator has good heat preservation effect. With
less loss of cold quantity, and ambient temperature is
relatively low, It is a normal phenomenon
High indoor humidity or low inside temperature value
is set. Wipe dry with a towel.
Refrigeration system is in
shutdown for a long time
while temperature inside is
still very low.
Condensates on glass door
Liquid flowing sound in
refrigerator
It is the sound that refrigeration agent is flowing in
pipes. It is a normal phenomenon.
1
5
4
Features
Concept of product
With elegant shape and quick refrigeration speed this commercial-use product is
an ideal choice for shopping malls, supermarkets, hotels and icerteria.
Design of transparent glass door
Using hollow toughened glass, the door with high transparency and good heat
insulation, freezers are clear at a glance.
Light Canopy
Top-placed independent Light Canopy or inner-placed Light Canopy has good
effects for advertising and branding and can be freely disassembled.
Wind cooling system
With fast cooling speed, there is more even temperature inside.
Movable shelves
It can be adjusted upside or downside for different goods' size.
Bottom casters
Convenient for moving, forepart with rubber feet, by adjusting which you can keep
the balance of the refrigerator.
Door lock
Lock knob is set at the lower left corner of the door. Lock can be used here to
make goods safe enough.
Box-type refrigeration unit
With system parts and key electric parts inside, it is easier and faster for repair.
Parts
(Model SC-310)
5
1- Light Canopy 2- Shelves 3- Handle
4- Down lock knob 5- Door Support 6- Magnetic switch of door
7- Front shield 8- Casters 9- Up hinge
10-Light switch 11- Glass door 12- Side lamp in cabinet
13- Down hinge 14- EMS control 15- Feet
16- Cabinet 17- Bumper bar 18- Filter screen
EMS-55 Malfunction & Maintenance
Malfunction hints
The following hints mean that you should inform the service people for
adjustment
Hi-temperature alarming light of the condenser sh red light on the
panel) together with the alarming sound malfunction with condensing system.
After eliminating the malfun ton.
If there n the panel together with the alarming sound:
Light is not on under operation mode.
There i nel malfunction with sensor controller.
Attention
EMS controller is fitted with sensing probe. Be sure that the orifice at left top side
is unclogged and unblocked.
Repair
The term of service of the EMS is the same as the machine you have purchased. If
EMS does not work properly, please inform our maintenance and repair men for
replacement. Do not disassemble it by yourself.
ows “on” (HT
ction, press the “UP” but
is “RSF” shown o
malfunction with refrigerating system. After eliminating the malfunction, press the
“DOWN” button.
s “PF”shown on the pa
14
EMS-55 Operation and function
Operation and function
Display temperature in the refrigerator
Press the 2 button at the right side on panel ('up' key), current temperature will
b
e shown on the display for about 5 seconds, and then it will return to the original
status automatically.
It is available for this operation under both operation mode and non-operation
mode and it can also be conducted several times.
Description above is applicable to the E43 edition.
For E46 edition, you can watch temperature on the panel.
If you want to check temperature setting, press
Pick-up sales/performance statistic data
When pressed 2 buttons at middle at one time, EMS will display the following
character s and statistic values
H1 the highest record temperature L0 the lowest record temperature
AT average temperature DC door opening counts
CNT pedestrians flow counts CC compressor (on/off) counts
CH compressor operation hours Af pedestrians flow density setting
Activate an extra defrosting
I
Distinguish EMS normal operation status
After plugging in, compressor runs firstly, about 20 seconds later air fan starts
to work.
nd
“SET” button(the first one from
the left side ) EMS will display both the letters “SP”intermittently (Setting
point) and the pre-selected temperature settings
f you want to activate an extra defrosting, press the“defrost” button at the right
side.
When the door is open, the interior air fan stops running(in a status that
temperature drops down continuously, interior air fan is not controlled by
open/close door) . Under the non-operation mode, interior air fan and
compressor work and stop alternatively.
System performs self-defrost every 6 hours. The whole process of defrosting
lasts around l5 minutes and the compressor stops while interior air fan still
works.
Operation mode, light is on; non-operation mode, off(delayed)
When door is open for 2 min, it will buzz; when it is open for more than 5min,
power will be cut off until door is closed.
1
3
Instruction
Ambient environment
This product should be placed on flat and solid ground, with pallet package removed so as to
reduce vibration and noise. Tilting angle should not be more than 45 when transportation
or moving.
This product should be placed far from direct sunlight and heat source and the surrounding
temperature should not be above 43 C.
To ensure normal refrigeration effect and easy ventilation and heat dissipation, there should
be enough room left around. Bumper bar should be installed at the back side and there
should be at least 5cm between the back side and wall.
Do not place it in environmentwhere it is too cold
Far from the humid place or where water is easily splashed. The splashed water and attains
should be cleaned by soft cloth in time to prevent the product from getting rusty or affect
the .
Do not place furniture or articles with sharp edges near the freezer in order to avoid possible
collision while opening the glass door.
insulating property
6
Preparations before operation
Removing all package materials
Footing adjustment
Installation of
Clean the refrigerator before operation
Standing
Plug in
Including foam pedestal, adhesive tape (to fix accessories), and protection gaskets.
Stably adjust footing according to the ground condition to reduce possible vibration and noise.
Bumper bar
Take Bumper bar (2 pieces) outside from the operation manual bag; separately screw them in
M8 holes clockwise at middle and lower part of refrigerator back until they are fixed.
After being moved, the refrigerator should be standing for more than 30 minutes before being
connected to power.
Plug in to make a trial operation, then check the EMS display of temperature inside the
cabinet. If the temperature drops continuously without alarm, it means refrigerator runs
normally
As top-placed independent light canopy, products SC-310/410/510 can be disassembled;
Disassembly of top-placed independent light canopy.
Disassembly of Light canopy and instruction
Light canopy is at the front top. Screw off thumbscrews at left/right ends
Pull out connection terminal between light canopy and freezer, then the light canopy can be
disassembled
The processing of assembly is just the reverse to disassembly.
EMS-55 display
Equipment instruction
EMS-55 is a control system especially developed for Coca Cola Company. The
system consists of energy saving controller, transformer, and temperature sensing
probes (2), magnetic spring switch (2), and auxiliary lines.
By self-learning from ambient (population flow, open/close times of door and
working time etc), EMS_55, could establish automation module, with which it
could also adjust freezer operation status automatically to adapt to actual operation
mode.
This control system changes the traditional mode operated by temperature
controller, and makes it easy to operate and realizes automatic alarming,
meanwhile it also extends refrigerator's life, reduces the repair rate and achieves
energy saving.
Display instruction
Letters displayed on EMS have the following meaning
Note: At edition E43 it shows USE for EMS's operating status; At edition E46
it shows current temperature in refrigerator under normal operating status.
12
Guide on food preservation
Clean food with water droplets wiped off could be stored in the refrigerator
It is prohibited to store live creatures, drug, flowers etc.
While food is being preserved, it is required to keep 1-3cm between food and
inner wall of refrigerator, which is good for cold air circulation.
There should be left enough space among food for cold air circulation.
Food should be sealed and packaged before it is stored, which could not only
prevent moisture from loss, but also avoid mixing of taste.
Proper package material should be used; such material must be poinsonless,
tasteless, airproof and waterproof.
Food should be placed by sorts, particularly for retail cooked food such as meat
and fish which should not be preserved for prolonged time.
When storing food, pay more attention on the storage term marked by
manufacturer. (You can mark the storage term on package to avoid overtime
storage
11
Startup,operation and temperature adjustment
Operation
temperature adjustment
After freezer is placed, generally it should run without storage for about half an
hour first, and then foods could be stored inside.
Storage temperature inside is controlled by the EMS system. the default setting
of operation mode is relatively lower but the non-operation mode setting is a little
bit higher . Temperature setting needs not adjusting in normal cases. If necessary,
please call the service hotline.
8
Lamp decoration, illumination and switches
Replacement of inner lamp
Replacement of
Light switch
SC-310/410/510 have
and inner side lamp. Its parameter is
shown as table.
Unplug, open the glass door at more than
90 degree.
Loosen screws of the lamp-shade and the end cover, then take off them.
Replace lamp tube with same power.
EMS part works as the 1 controller, and light switch at upper end cap of side
lamp work as the 2 controller. Under EMS's operation mode, light switch
controls illumination. Under EMS's non-operation mode, light switch do not work,
all lights are off.
During the period 1 means on 0 means off
top light canopy
canopy
Pull out connector parts at the ends of lamp, then take off the lamp tube.
Install new lamp tube, installation procedure is reverse.
Unplug, loosen screws on bond strip , draw out the lining board.
Installation procedure is reverse.
If there is any malfunction with starter, ballast or tube please call professional
people for replacement.
light canopy
st
nd
“” “”
Lamp type
Model
Inner Side
lamp
9
light
canopy
Repair & maintenance for refrigeration cassette
It is convenient for repair that the refrigeration units (compressor, evaporator,
condensator, evaporation fan, condensation fan, filter, and etc) are designed as
box-type and are placed inside. While repairing, the unit can be replaced directly.
Disassembly procedure is as below,
1.Unplug, remove the fixing screws of the front cover, then take down the front
cover. Front cover fixing screws.
2.Pull out connection plugs and all terminals
Terminals that need to be unplugged
3.Remove fixing screws on 2 wrenches, adjust them to be upright, turn them
inside together and do not stop unit the units fall steadily
4.Remove 2 wrenches, draw out the units, then replace or repair them
5.Assemble all parts as the reverse procedure after repair.
To guarantee the normal operation, please rinse the air intake filter screen (on
front cover) regularly. The procedure is given below,
1.Open the door
2.Take the filter screen upside and get it out;
3.using soft brush to clean dust on the air intake filter screen
4.Install the screen after cleaning
Notes Cleaning should be done every 5-6 months according to the operating
ambient of the freezer .
Cleaning the air intake filter screen
1
0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Haier SC-510 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI