e shown on the display for about 5 seconds, and then it will return to the original
status automatically.
It is available for this operation under both operation mode and non-operation
mode and it can also be conducted several times.
Description above is applicable to the E43 edition.
For E46 edition, you can watch temperature on the panel.
If you want to check temperature setting, press
Pick-up sales/performance statistic data
When pressed 2 buttons at middle at one time, EMS will display the following
character s and statistic values
H1 the highest record temperature L0 the lowest record temperature
AT average temperature DC door opening counts
CNT pedestrians flow counts CC compressor (on/off) counts
CH compressor operation hours Af pedestrians flow density setting
Activate an extra defrosting
I
Distinguish EMS normal operation status
After plugging in, compressor runs firstly, about 20 seconds later air fan starts
to work.
nd
“SET” button(the first one from
the left side ) EMS will display both the letters “SP”intermittently (Setting
point) and the pre-selected temperature settings
f you want to activate an extra defrosting, press the“defrost” button at the right
side.
When the door is open, the interior air fan stops running(in a status that
temperature drops down continuously, interior air fan is not controlled by
open/close door) . Under the non-operation mode, interior air fan and
compressor work and stop alternatively.
System performs self-defrost every 6 hours. The whole process of defrosting
lasts around l5 minutes and the compressor stops while interior air fan still
works.
Operation mode, light is on; non-operation mode, off(delayed)
When door is open for 2 min, it will buzz; when it is open for more than 5min,
power will be cut off until door is closed.
1
Instruction
Ambient environment
This product should be placed on flat and solid ground, with pallet package removed so as to
reduce vibration and noise. Tilting angle should not be more than 45 when transportation
or moving.
This product should be placed far from direct sunlight and heat source and the surrounding
temperature should not be above 43 C.
To ensure normal refrigeration effect and easy ventilation and heat dissipation, there should
be enough room left around. Bumper bar should be installed at the back side and there
should be at least 5cm between the back side and wall.
Do not place it in environmentwhere it is too cold
Far from the humid place or where water is easily splashed. The splashed water and attains
should be cleaned by soft cloth in time to prevent the product from getting rusty or affect
the .
Do not place furniture or articles with sharp edges near the freezer in order to avoid possible
collision while opening the glass door.
insulating property