Breezair ILL239-D Owner's manual

Type
Owner's manual

This manual is also suitable for

Breezair ILL239-D is an evaporative cooler that provides quiet, reliable, and cool comfort for your home. It features a remote thermostat control for easy operation, adjustable fan speed for customized airflow, and an economy mode for energy savings. Additionally, the cooler has a pre-cool mode to saturate the cooling pads before fan activation, ensuring optimal cooling performance.

Breezair ILL239-D is an evaporative cooler that provides quiet, reliable, and cool comfort for your home. It features a remote thermostat control for easy operation, adjustable fan speed for customized airflow, and an economy mode for energy savings. Additionally, the cooler has a pre-cool mode to saturate the cooling pads before fan activation, ensuring optimal cooling performance.

(English)(EXH,EZH)
OWNER’SMANUAL
EvaporativeCooler
AUTO COOL
PM
FAN
SPEED
ECONOMY
REMOTECONTROL
ILL239-D ILL1140-A
2EvaporativeCooler
Introduction............................................................4
Remote ThermostatControl..................................5
WallMounted ThermostatControl.......................11
BleedSystem.......................................................14
DrainValve..........................................................14
PowerOutages....................................................15
Maintenance........................................................15
RoutineMaintenanceServiceSchedule
Checklist..............................................................17
Troubleshooting...................................................18
Service&Warranty .............................................20
WallMounted ThermostatControl
(wallcontrol)
Remote ThermostatControl
(remotecontrol)
AUTO COOL
PM
FAN
SPEED
ECONOMY
REMOTECONTROL
ILL239-D ILL1140-A
SEELEY INTERNATIONAL – OWNER’SMANUAL 3
CongratulationsonpurchasingaBreezair
DuctedCoolerforyourhome.
Breezair coolershavebeendesignedto
providequiet,reliableandcoolcomfort.
AtSeeleyInternationalwemanufacture
Breezair evaporativecoolersfromthehighest
qualitymaterials,andwehavedesignedthe
producttoprovidemanyyearsofeconomical,
troublefreecooling.
Pleasetakeafewmomentstoreadthese
operatinginstructions,sothatthemostcanbe
gainedfromthisinvestment.
Breezair coolersarefittedwitheitheraWall
Mounted ThermostatControloraRemote
ThermostatControl.Pleaserefertothe
relevantsectioninthismanualforinstructions
onhowtooperateeithersystem. Also,please
beawareofthecomponentsandfeaturesthat
arefittedtoyourparticularcooler.
®
®
®
®
Keeptheseinstructionsinasafeplacefor
futurereference.
Theapplianceisnotintendedforuseby
persons(includingchildren)withreduced
physical,sensoryormentalcapabilities,or
lackofexperienceandknowledge,unless
theyhavebeengivensupervisionor
instructionconcerningtheuseoftheappliance
byapersonresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethat
theydonotplaywiththeappliance.
EffectiveCooling
ImportantNotes!
Toprovideefficientcoolingorventilation
thebuildingmusthavesufficientexhaust
openingstotheoutsideofthebuilding. To
assistairflow,openwindowsanddoors
thatarefarthestfromtheoutletventin
eachroom.Intheserooms,providean
exhaustopeningabout2timesthevent
sizeoftheroom.
Wherethedesignofthebuildingprevents
adequateexhaust,considerationshould
begiventotheprovisionofmechanical
extractions,suchasanexhaustfan.
Inareaswheretemperaturescancause
watersupplypipestofreeze,adraindown
facilityshouldbeprovidedduringthe
installation. Thisdraindownfacilitymust
beactivatedpriortofreezingconditions,
toavoidpossibledamagetothecooler
components.
Ifthesupplycordisdamaged,itmustbe
replacedwithaspecialcordavailable
fromthemanufactureroritsService
AgentsandreplacedbyaService Agent
orsimilarlyqualifiedpersoninorderto
avoidahazard.
Donotoperateanycoolerwitha
damagedcordorplug.
INTRODUCTION
4EvaporativeCooler
SettingtheClock
Settheclockontheremotecontrol
beforeproceedingwithanyother
programming.
Theclockcanonlybesetwiththe
remotecontrolswitchedOFF.Holdthe
buttondownforover2seconds,
untilthehourflashes.
Usetheandbuttonsto
changethehour. Tochangeminutes,
pressthebuttonagain.Change
theminutesusingtheand
buttons.
Tolockinthetimesetting,andenterthe
OFFstate,pressthebutton. The
displaywillstopflashing.
Theremotecontrolisswitchedonand
offusingthebutton. The
memorywillstore
Theclockcanbe
settoeither12or24hours(seepage
10).Iftheclockissetto12hoursmake
surethatthe AM/PMdisplayedonthe
screeniscorrect. AM/PMwillchange
withadjustmentofthehour.
andusethesettings
fromwhenthecoolerwaslastused.
Oncetheremotecontrolison,youcan
choosebetweenMANUAL, AUTOand
AUTO TIMERmodesbypressingthe
button.
TurningontheCooler
ManualMode
WiththeremotecontrolON,pressthe
buttonuntilMANUAL isshowninthetopleft
cornerofthedisplay.
ThebuttonisusedtoselectVENT
(wherefreshairisbeingdeliveredwithoutbeing
cooled)orCOOL.
OnceeitherCOOL orVENT hasbeenselected,
theremotecontrolwillmaintainaconstantfan
speed. Thisisindicatedbythebargraphinthe
centreofthedisplay.
To or thefanspeedrequired,
presseithertheorbuttons.
decrease increase
MANUAL
COOL
FAN
SPEED
ILL1108-A
MANUAL VENT
FAN
SPEED
ILL1109-A
ILL1104-A
PM
REMOTETHERMOSTATCONTROL
SEELEY INTERNATIONAL – OWNER’SMANUAL 5
AutoMode
Theremotecontrolcontainsathermostat.In
AUTOmodethecooleriscontrolled
automatically,basedonyourpre-
comfortlevel. Thecoolerwilladjustthefan
speed,switchbetweenCOOL andVENT and
turnitselfoff.However,thesequenceand
regularityatwhichthesesettingschangewill
differwitheachoperationofthecooler.
Astheremotecontrolsensesroomconditions,
the
heatfromdirectsunlightorelectrical
appliances.Likewiseplacingtheremote
controlincupboardsordrawersorunder
coolingventswillaffectthecooler’soperation.
Tosetthe AUTOmodepressthebutton
until AUTOisdisplayed.
Tenlevelsofcomfortareavailablewiththe
remotecontrol.Whilein AUTOmodepressing
theand buttonswilladjustthe
levelofrequiredcomfort. Thedisplay
selected
comfortcontrolsettingswillbeinfluenced
by
will
showyourselectionbyindicatingalevel
between1and10.WARMERorCOOLERwill
bedisplayedonthescreenassettingsare
changed.
AutoTimerMode
AUTO TIMERmodecanbeselectedby
usingthebutton.Oncethe AUTO
TIMERmodeisselectedthecoolerwill
onlyoperateduringtheprogrammedtime
period.
Programmingthetimermustbeperformed
before AUTO TIMERcanbeactivated.
Thiscanbedonewhileinanymode,even
whenitisOFF. Thereare7stepsinvolved
insettingthe AUTO TIMER.
NOTE: Afterpressingthebuttonthe
displaywillrevertbacktotheprevious
settingifnobuttonsarepressedwithin4
seconds.
Toprogramthetimerusethefollowing
sequence:
(1)SettingtheONtimehour
Beginbypressingthebutton. The
hourdisplayedwillstartflashingandthe
wordONwillappearonthescreen. Then
usethe andbuttonsto
changethehourvalue.
AUTO
TIMER ON
ILL1112-A
AUTO
FAN
SPEED
ILL1105-A
PM
REMOTETHERMOSTATCONTROL cont.
6EvaporativeCooler
(2)SettingtheONtimeminutes
(3)SettingtheOFFtimehour
Pressthebutton. Theminutes
displayedwillstartflashingandtheword
ONwillappearonthescreen. Thenuse
the and buttonstochange
theminutesetting.
Pressthe button. Thehour
displayedwillstartflashingandOFFwill
bedisplayed. Thenusetheand
buttonstochangethehour.
Pressthe button. Theminutes
displayedwillstartflashingandtheword
OFFwillappear. Thenusethe
and buttonstochangetheminute
setting.
(4)SettingtheOFFtimeminutes
AUTO
TIMER ON
ILL1113-A
AUTO
TIMER
OFF
ILL1114-A
AUTO
TIMER
OFF
ILL1115-A
(5)Settingthecomfortlevel
Pressthe buttonandthecomfortlevel
number(1to10)displayedwillstartflashing.
Thenusetheandbuttonsto
changethissetting.
Toselecteconomypressthebuttonso
thatitisdisplayedonthescreen.
Nowthatyouhaveprogrammedthesettingsfor
AUTO TIMERtheywillbestoredintheremote
control’smemoryuntilyouchangethem.Press
the buttonuntil AUTO TIMERisdisplayed
onthescreen. Yourcoolerwillnowonlyoperate
duringtheprogrammedtimeperiod.
NOTE: Tochangeany AUTO TIMERsettings
whentheremotecontrolisswitchedoff,the
buttonneedstobepressedandreleased
within1second. Tochangesettingswhenthe
remotecontrolisturnedonpressthe
buttonuntilthedesirednumberisflashing.
(6)SettingECONOMY
(7) Activating AUTO TIMER
AUTO
TIMER
ILL1116-A
REMOTETHERMOSTATCONTROL cont.
SEELEY INTERNATIONAL – OWNER’SMANUAL 7
EconomyMode
DrainMode
SelectingtheECONOMY modelimitsthe
maximumavailablecoolingorventilationand
reducesthepowerusedbyupto20%. The
ECONOMY functioncanbeusedineither
AUTO MANUAL modes. Toselectthis
modepressthebuttonsothatECONOMY
appearsonthedisplay.
Pressingthebuttonopensthedrain
valveinthecoolerandemptiesthewaterin
thetank. Thiswillleavethetankcleananddry
andturnthecooleroff.
Ifthecoolerhasnotbeenusedfor3daysor3
hours,dependingontheDIP switchsetting-
seepage10,thetankwillautomaticallybe
drainedtoensurethesystemremainsclean.
or
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1125-A
DRAINTANK
ILL1107-A
Pre-coolMode
Yourremotecontrolisdesignedtoallow
forthesaturationofthecoolerscooling
padsbeforethefanisswitchedon. This
function,referredtoasPRE-COOL mode,
isenabledatDIP switchD(refertopage
10).Onceitisenabledthecooler,
willoperateasfollows:
(1)......Ifthetankisemptythe
drainsystemwillbeclosed. Thetankwill
thenbefilled.
(2)...... After60secondsofthetankfilling
withwater,thepumpwillturnonand
saturatethefilterpads.
(3)...... Afterthepumphasbeenrunning
for3minutesthefanwillstart.
DuringthisoperationthewordPRE-COOL
willbedisplayedontheremotecontrol’s
screen.
NOTE:PRE-COOL modewillnotbe
activatedifVENT isselectedonthe
remotecontrolorthecoolerisusedagain
shortlyafterhavingbeenturnedoff.
when
firstswitchedon,
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1142-A
PRE-COOL
REMOTETHERMOSTATCONTROL cont.
8EvaporativeCooler
WATERMANAGER®
TheBreezair remotecontrolisfitted
withthe feature
whichautomaticallymonitorsthequality
ofthewaterinthecooler.
The drainsthe
existingwaterinthecoolertoallowitto
bereplacedwithfreshwater,onlywhen
itisneeded. Therefore,youmaynotice
yourcoolerdrainingwateroccasionally.
Howoftenthe
performsthisoperationdependsupon
thequalityofthewatersupplyandthe
rateofevaporation.
Inareasofpoorwaterquality,the
willoperatemore
oftenasittriestomaintaintheoptimum
waterqualityinthecooler. This
maximisesthecoolingeffectandlifeof
thecoolingpads.
Theremotecontrolhasauniquefeature
attachedtothe that
allowsyoutospecifyeitherhighorlow
salinitysettings. Thelowsalinitysetting
isusedinspecificcircumstancesonly.
Werecommendtalkingwithyourdealer
beforeadjustingthissetting.
®
WATER
WATER
WATER
WATER
WATER
MANAGER
MANAGER
MANAGER
MANAGER
MANAGER
®
®
®
®
®
Thehighsalinitysettingisdesignedtooperate
thecooleratamaximumsafesalinitylevelto
maintainanormalworkinglife.Italsoresultsin
aminimumusageofwater.
NOTE:Highsalinityoutletwatershouldnotbe
usedonsaltsensitivegrassorplants.Ithasa
highsaltcontent.
Thecurrent settingis
displayedbyholdingdownthebuttonand
pressingthebutton. Thesettingcanbe
changedbyholdingdownthebuttonand
pressingeitherthe or buttonfor
HIandLOrespectively.
Thefactorydefault setting
isHI.Forareasoperatingwithborewater,DIP
switch6shouldbeswitchedtooff(seepage
10). Thiswilldisablethesalinitymeasuring
circuitandsimplydrainwaterfromthetank
every65minutesofoperation.
WATER
WATER
MANAGER
MANAGER
®
®
.......
MANUAL
COOL
FAN
SPEED
ECONOMY
ILL1111-A
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1110-A
REMOTETHERMOSTATCONTROL cont.
SEELEY INTERNATIONAL – OWNER’SMANUAL 9
Batteries
Ifthebatteriesareinstalledwhenthedisplay
iscompletelyblank,thedisplaywillremain
blankfor5seconds. After5secondsthe
displaywillshow “Id” for1second,then
displaytheclock. Theremotecontrolisnow
readytouse.
Theremotecontrolrequires3 AAA batteries.
Theuseofgoodqualityalkalinebatteriesis
recommended.Undernormalconditionsaset
ofbatterieswilloperatefor18months.
Whenthebatteriesaregettinglowonpower,
BATTERY LOWisdisplayedonthescreen
(thecoolermayalsoswitchoffwhilethe
displayremainsON). Thisindicatesthatthe
batterieshaveonlyasmallamountoflife
remaining.
Tochangethebatteriesremovethecover
fromthebackoftheremotecontrol.Pullout
theoldbatteriesandreplacethemallwiththe
newones.Donotmixnewbatterieswithold
batteries.
Theremotecontrolhas2minutesofback-up
powertoretainitsmemorywhilethebatteries
arebeingchanged.
Donot
userechargeablebatteriesastheirvoltage
ratingistoolowfortheremotecontrol.
DipSwitches
WARNING:DonotalterDIP switches1
to8inthetoprowand7&8inthe
bottomrowasthecoolerwillceaseto
work.
Thereare2rowsofDIP switcheslocated
underthebatterycoverontheremote
control.
DefinitionofDIP switchpositions(first6in
bottomrowonly)areasfollows:
(1). Reservedforlateruse.
(2). OFF,24hourclock.
ON,12hourclock.
(3). OFF,1100/1500Wmotor.
ON,500/550/750Wmotor.
(4). OFF,nopre-cool.
ON,pre-cool.
(5). OFF,drains3daysafterpoweroff.
ON,drains3hoursafterpoweroff.
(6). OFF,drainsevery65minutesof
operation.
ON,activateswatersalinitycircuit
( ).WATERMANAGER®
EXAMPLEONLY
AUTO COOL
PM
FAN
SPEED
BATTERYLOW
ILL1106-A
ILL217-H
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
OFF
REMOTETHERMOSTATCONTROL cont.
10 EvaporativeCooler
TurningtheCoolerOn
PreparingtoStart
ManualMode
Thewallcontrolcanbeswitchedonand
offbypressingthe button. The
wallcontrolwillremembertheprevious
settingitwasinwhenthecoolerwaslast
used.
WiththewallcontrolswitchedON,press
thebuttonuntilMANisshown
onthedisplay.
Youmaythenpressthe
buttontoswitchbetweenCOOL and
VENT (wherefreshairisbeingdelivered
butnotcooled).
Wheneveryouselect AUTOmodeor
COOL inMANUAL mode,thecoolerwill
takeafewminutestostartasitfillswith
waterandsaturatesthecoolingpads.
Thetimewillbedecreasedifthetankis
fullorthecoolerhasonlyrecentlybeen
turnedOFF.Duringthistime
PREPARING TOSTART willflashonthe
display.
ILL1122-B
OnceCOOL orVENT hasbeenselected,the
wallcontrolwillmaintainaconstantfanspeed.
Thisisindicatedbythebargraphshownonthe
display.
In AUTOmodethecoolerwillrememberthelast
settingusedandtrytoachievethis.Itmayvary
dependingontheday’sconditions.Pressthe
buttonifyourequiremorecoolairorthe
buttonifyourequireless.Don’talterthe
settinghowever,untiltheroomtemperaturehas
stabilised.
Toincreaseordecreasethefanspeedrequired,
presseithertheor button.
Toselectthe AUTOmodepressthe
buttonuntil AUTOisshownonthe
display.
AutoMode
ILL1124-B
ILL1123-B
WALL MOUNTEDTHERMOSTATCONTROL
SEELEY INTERNATIONAL – OWNER’SMANUAL 11
Programminginautomode
(1)......Pressthebutton.
Pressthebutton
until AUTOisdisplayed.
(3)......Pressthebuttonandthe
‘startsin’ timewillstartflashing.
Usetheor
buttontoselectthehour.
(4)......Pressagain.
Thedelayedstoptimecanonlybe
programmedoncethecoolerisON. This
isidealifyouaregoingtobedbutdon’t
wanttoturnthecooleroffstraightaway.
Toprogramthedelayedtimeinwhichyou
wantthecoolertostopusethefollowing
sequence:
(1)......Selectthebuttonandthe
‘stopsin’ timewillstartflashing.Use
theand buttonsto
selectthedesiredofftime.
(2)......Pressagain.
(2)......
DelayedStartorStop
Thecoolercanbeprogrammedtostartata
specifictimeorstopataspecifictime.
Thedelayedstarttimecanonlybe
programmedwhenthecoolerisOFF. To
programthecoolertostartinacertainamount
ofhoursusethefollowingsequence:
(1)......Pressthebutton.
(2)......PressthebuttonuntilMANis
displayedonthescreen.
(3)......Presstheorbutton
untilthedesiredfanspeedisdisplayed
bythebarsinthemiddleofthescreen.
(4)......Pressthe buttontoseteither
COOL orVENT.
(5)......Pressthe buttonandthe ‘starts
in’ timewillstartflashing.Usethe
andbuttonstoselect
thedesiredtime.
(6)......Pressagain.
Programminginmanualmode
ILL1119-B
ILL1118-B
ILL1117-B
WALL MOUNTEDTHERMOSTATCONTROL cont.
12 EvaporativeCooler
ServiceMode
Whenafaulthasbeenrecognisedbythe
wallcontrolthewordSERVICEflashes
onthescreen.
WhenSERVICEisdisplayeditmaybe
necessaryforyoutophonetheService
numberlocatedonthebackofthis
manual.However,beforedoingso,turn
thewallcontrolOFF. Youwillnoticea
numberflashingatthebottomofthe
screen. Thisnumberindicatesthe
reasonforrequiringservice.
Pleasewritethisnumberdown,then
pushthebuttontoturnthecooler
backon.IfafterashorttimeSERVICEis
againshownonthedisplay,turnthewall
controlOFFandcheckiftheflashing
numberisthesame.Ifitischeckthe
followingpossibleproblems.However,
wedosuggestthatanychecksbe
carriedoutbyanauthoriseddealeror
serviceagent.
Service
ILL1120-B
Service
ILL1121-B
If ‘02’ isdisplayed
If ‘04’ isdisplayed
MANAGER
(1)......Checkthatthewatersupplytaptothe
cooleristurnedon.
(2)......Checkthatyourlocalwaterauthority
haven’ttemporarilydisconnectedthe
waterinyourarea.
(1)......Ifyourcoolerisfittedwithadrainvalve,
checkthatthedrainisnotblocked.
Thefollowingoperatingparameterscanbe
adjustedusingthewallcontrolbutonlyifadrain
valvehasbeenfittedtoyourcooler.
Thisparametercontrolsthefollowing2options.
Value0usestheintelligent
whichmeasuresandcontrolsthewaters
salinitylevel.Value1drainsthetankevery65
minuteswhenthecoolerisON.Value0isthe
presetandpreferredsetting.
Ifthesedonotfixtheproblemthencontactyour
DealerortheServicenumberonthebackof
thismanual. Youwillneedtoquotetheflashing
numberthatyouwrotedown.
DrainMode
(CoolerswitchedOFF)
ChangingtheDefaultParameterSettings
SalinityControlMethodSelector
WATER ®
Pressingtheandbuttonsat
thesametimefor2secondswillopenthedrain
valveandemptythewaterinthetank. Thewall
controlwilldisplayDRonthescreen.Draining
thewaterwillleavethetankcleananddryuntil
itisnextused.
WALL MOUNTEDTHERMOSTATCONTROL cont.
SEELEY INTERNATIONAL – OWNER’SMANUAL 13
Tochangethesalinitycontrolsettingusethe
followingsequence:
(1)......WiththewallcontrolturnedOFF,hold
downthebutton.Continueto
holdthisbuttondownandpressthe
button. Thecurrentsettingand
the3rightmostfanspeedbarswillbe
displayed.
(2)......Presstheorbuttonto
scrollthroughthevarioussetting
optionsdiscussedpreviously.
(3)......Whenthedesiredsettingisdisplayed,
pressthebuttontostorethe
newsetting.
Thisparameterchangesthetimebeforethe
tankisemptiedofwater,afterthecoolerhas
beenturnedoff. The5optionsavailableare:
0=4hours
1=1day
2=2days
3=3days(default)
4=4days.
Tochangethetankdraindelayusethe
followingsequence:
(1)......WiththewallcontrolturnedOFF,hold
downthebutton.Whileholding
downthisbuttonpressthe
button. Thecurrentsettingand3central
fanspeedbarswillbedisplayed.
(2)......Presstheor
buttontoscrollthroughtheavailable
settings.
(3)......Whenthedesiredsettingisdisplayed,
pressthebuttontostorethe
newsetting.
TankDrainDelay
Yourcoolerisfittedwithoneoftwowater
managementsystemsdesignedtocontrol
thewatersalinityandoptimisethelifeof
thepadsinyourcooler.
Iffitted,thebleedsystem,picturedon
page16,willconstantlydrainsmall
amountsofwaterduringtheoperationof
thecooler. Thisallowsfreshwatertobe
addeddilutinganymineralsandsalts
accumulated.
Thebleedrateforyourcoolerwilldepend
onlocaloperatingconditionsandwillbe
setbytheinstaller.
BleedSystem
DrainValve
Ifyourcoolerhasbeeninstalledwitha
drainvalveitisaccompaniedbythe
salinityprobes.When
thetank’swatersalinitylevelreachesa
presetlevelthe will
openthedrainvalveandreleaseabout6
to8litres.Freshwaterwillthenbeadded
dilutinganymineralsorsalts
accumulated. The
willcontinuetomonitoranddrainwateras
required.
Alternatively,thecoolercanbesetto
drain6to8litresofwateratapreset
periodofpumpoperatingtime. Thiscan
besetbychangingthesalinitycontrol
methodselectorifusingthewallcontrol,
orDIP switch6ifusingtheremotecontrol.
WATER
WATER
WATER
MANAGER
MANAGER
MANAGER
®
®
®
NOTE:Whenthecoolerstankisempty
andthecooleristurnedonagain,thefan
operationwillbedelayedasthetankis
refilledandthepadsaresaturated.
WALL MOUNTEDTHERMOSTATCONTROL cont.
14 EvaporativeCooler
Ifthepowerinyourhomegoesofffor
lessthan5secondsthecoolerwillretain
itscurrentsettings. Thatis,itwillstopfor
thetimethepowerisoffbutresume
operationwhenthepowercomesback
onagain.Ifthepowergoesoffformore
than5secondsthecoolerwill
automaticallyturnitselfoff. Thatis,once
thepowercomesbackonthecoolerwill
notresumeoperation. Youwillhaveto
turnthecoolerbackonusingthewall
controlorremotecontrol.
Insomestates,regulationsrequirethat
evaporativeaircoolersbeservicedat
specificintervals.
Seasonalmaintenanceisonlyrequiredif
youhaveacoolerfittedwithableed
system. Thefollowingpagesoutlinethe
maintenancerequiredattheendofthe
seasonandthenatthestartofthenext
season. Thisensuresthatyourcooler
continuestooperateefficiently.
Ifyourcoolerisfittedwithadrainvalve,
reducedseasonalmaintenanceis
required.However,werequirethatthe
followingcomponentsandtheoperation
thereof,becheckedafterthefirstyear,
thenevery2yearsasroutine
maintenance.
(1)....Waterdistributionspreadertrays.
(2)....Pump.
(3)....Drainvalve.
(4)....Solenoidandassociatedfilter.
(5)....Fanmotoroperationandcurrent.
(6)....Floatvalve.
(7)....Salinityprobes.
MAINTENANCE
HealthRegulations
SeasonalMaintenance
Note
Failuretocarryoutregularmaintenancewill
affectyourwarrantycoverage.
!
WARNING:
Asyourcoolerismountedontheroof,we
suggestthatanymaintenanceorchecksbe
carriedoutbyanauthorisedBreezairdealer
orserviceagent.Climbingontotheroofcan
behazardousandcouldresultininjuryto
youanddamagetoyourproperty.
Routinemaintenancemayberequired
morefrequentlyinadverseenvironmental
situationsandverydustyareas.
POWEROUTAGES MAINTENANCEcont.
1
ILL1141-A
2
1
EndofSeason
(1)..Turnoffthewatersupplytothecooler.
(2)..Removethepadframesasshownonpage
16.
(3)..Turnoffthepowerattheisolatingswitch
insidethecooler.
(4)..Checkandcleanthewaterdistributing
channelsunderthelid.
(5)..Unclipandremovethebleedsystemas
shownbelow. Takecarenottolosetheo-
ring. Thisremovalwillallowthewaterto
drainfromthetankthroughoutthewinter.
(6)..Thoroughlycleanthetankandthepump
filter.Donotreplacethebleedsystem.If
youdo,waterwillsitwithoutdrainingfrom
thetankthroughoutthewintermonths.
(7)..Refitthepadframes.
SEELEY INTERNATIONAL – OWNER’SMANUAL 15
(3)...Takeholdofthepadframe,pivotit
outwardsandliftitup.Becarefulnotto
damagethepad.
Repeatthestepsabovewiththe3remaining
padframes.
(ForEXH210unitsonly) Thereare90mm
padsfittedtothefrontandrear,with100mm
padsfittedtothesides(facingthefanscroll
holes). Thesepadsmustberefittedtotheir
originalpositions,orthelargerpadscouldcatch
onthefloatvalveorcomponentsmountedon
thescroll.
The100mmpadscanbeidentifiedbyarebate
atthebaseoftheChillcel.
Iffittedincorrectly,adropinperformance
maybefound,watercanbypassthepadand
becarriedoverintotheairstreamand
ductingand/ordamagetothepadsor
electroniccomponentsmayoccur.
ILL950-C
1
2
ILL187-E
1
2
Pre-season
(1)...Turnyourmainswitchboardpower
off.
(2)...Removethepadframesasshown
inthenextcolumn.
(3)...Ensurethepowerisoffatthe
isolatingswitchinsidethecooler.
(4)...Gentlywashthepadframesto
removeanydustbuildupduringthe
winter.
Ifthepadsaresalted-up
replacethem.
(5)...Replacethebleedsystemthatwas
removedattheendofthelast
season.Ensurethattheo-ringisin
placeandthatthetrayispositioned
sothatitcancatchthewaterfrom
thepad.
(6)...Turnonthewatersupplytothe
cooler.
(7)...Checkforwaterleaks.Check
operationoffloatvalve.
(8)...Checkifadj.requiredtobeltdrive.
Resetmotoramps.
(9)...Switchontheisolatingswitch.
(10).Refitthepadframes.
(11).Turnthepoweronatyourmain
switchboard.
(12).Runthecooler.
NOTE:Donotwashthe
padswithhighpressurewater
spray.
WARNING:Donot
runthecoolerwiththepad
framesremoved.
RemovingPadFrames
Toremoveapadframe:
(1)...Removetheclipsholdingthepad
frameinplace.
(2)...Insertaflatheadscrewdriverinto
theslotbetweenthelidandthetop
ofthepadframe.Leveritsothepad
frameisreleased.
3
3
MAINTENANCEcont.
16 EvaporativeCooler
ROUTINEMAINTENANCESERVICESCHEDULECHECKLIST
ServiceItem Check/adjust Clean Replace
123451234512345
Components
GeneralOperation
Chillcelpads(replaceasrequired)
Padretainingwashers/pins
Base/waterreservoir
Pumpfilterbasket
Waterprobes
Waterdistributionsystem
Washers,sealsandO-rings(replace
asrequired)
DrainValve
Bleedrateset(whererequired)
Waterlevelsetpoint
Waterfilltime
Waterdraintime
Waterdistributionacrosspads(nodryspots)
Airflowthroughsystem/outlets
Generalproductcondition
ServiceNo ServiceDate Service Technician ServiceCompany
No1 ..................... .......................................... ........................................................
No2 ..................... .......................................... ........................................................
No3 ..................... .......................................... ........................................................
No4 ..................... .......................................... ........................................................
No5 ..................... .......................................... ........................................................
(NOTE:includescorrectfittingofallcomponentsanditems-replaceasrequired)
SEELEY INTERNATIONAL – OWNER’SMANUAL 17
SYMPTOM CAUSE ACTION
Unpleasantodour. Odourfromthenew
pads.
Allowtimetocondition
byrunningthecooler.
Inadequatecooling. Drypads. Ensurethewatersupply
isturnedon. Then
checkthewaterflowto
thepads.
Insufficientexhaust
openingsfor
conditionedair.
Ensuresufficient
openings.Referto
Introduction “Effective
Cooling”.
Excessiveambient
humidity.
Ondaysduringthe
summerwhenthe
ambienthumidityis
high,thecoolerwillnot
reducethe
temperatureasmuch
asondrierdays.
Remotecontrolhas
nodisplay.
Batteriesare
incorrectlyfittedorthey
areflat.
R orr the
batteries.
efit eplace
Remotecontrolhasflat
batteries.
Replacethebatteries.
Faultinthecooler. ContacttheDealeror
Servicenumber.
Ifthewallorremote
controlisin AUTOor
AUTO TIMERmode
andnofanbarsare
displayedthefanwill
notcomeon.
SwitchtoMANUAL
modetocheckthefan
operation.
CoolerturnsON
andOFF.
Fandoesnotstart
butotherfunctions
work.
If your wall control displays SERVICE or should you consider that your cooler requires service,
contact your local Dealer or the Service number on the back of this manual.
TROUBLESHOOTING
18 EvaporativeCooler
WALL CONTROL DISPLAYS SERVICE
SERVICE
SERVICE
immediatelyonpower
upindicates
communicationsneeds
tobeestablished
Push&holdthe
buttonforat
least10secondsuntil
theword
disappears
DOWN
SERVICE
Ifoninitialstartuptheword “Service” appearsonthecontrollerandbypushingtheon/off
buttonnothinghappens.
Thenyouwillneedtoestablishcommunicationbetweenthewallcontrolandtheelectronic
controller.Simplypushandholdthe “DOWN” buttonforapprox.10secondsoruntiltheword
“Service” disappears.Ifbypushingtheon/offbuttonanumberappears,contactyourlocal
DealerortheServicenumberonthebackofthismanualandquotetheFaultCodenumber
displayed.
SEELEY INTERNATIONAL OWNER’SMANUAL 19
18 EvaporativeCooler
WarrantyService
Australia1-300-650-644
seeleyinternational.com
ItisthepolicyofSeeleyInternationaltointroducecontinual
productimprovement. Accordingly,specificationsare
subjecttochangewithoutnotice.Pleaseconsultwithyour
dealertoconfirmthespecificationsofthemodelselected.
WhenyoucontactyourDealerregardingservice
orwarrantypleasequotethecoolermodel
numberandserialnumberasshownbelow.
839103-N
Affixserial&model
number kerherestic
seeleyinternational.com AU1308
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Breezair ILL239-D Owner's manual

Type
Owner's manual
This manual is also suitable for

Breezair ILL239-D is an evaporative cooler that provides quiet, reliable, and cool comfort for your home. It features a remote thermostat control for easy operation, adjustable fan speed for customized airflow, and an economy mode for energy savings. Additionally, the cooler has a pre-cool mode to saturate the cooling pads before fan activation, ensuring optimal cooling performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI