Friedrich 2009, 2008 User manual

  • Hello! I am an AI chatbot trained to assist you with the Friedrich 2009 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Service Manual
WallMaster
®
Thru-the-Wall
WM-ServMan (04-09)
Wa
i
t
th
r
e
e
m
i
n
u
tes
be
for
e
r
es
t
a
rt
in
g
Wa
r
m
e
r
Cool
e
r
F
an
O
n
ly
Low
H
e
a
t
Me
d
H
e
a
t
Hi
g
h
H
eat
Lo
w
C
oo
l
M
e
d
C
oo
l
H
i
g
h
C
oo
l
M
O
DE
TE
M
P
E
R
A
T UR
E
72
Models
2009
2008
M
o
n
ey
F
a
n
Tim
e
r O
p
e
r
a
ti
o
n
S
e
tH
r
.
S
t
o
p
S
t
a
r
t
Tem
p
e
ra
t
ure
Fa
n
Co
o
l
O
n
/
O
f
f
Powe
r
C
o
o
ler
O
n
ly S
p
e
e
d
S
a
v
e
r
®
Wa
r
m
e
r
FRIEDRICH AIR CONDITIONING CO.
Post Ofce Box 1540 · San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212
(210) 357-4400 · FAX (210) 357-4490
www.friedrich.com
Printed in the U.S.A.
TECHNICAL SUPPORT
CONTACT INFORMATION
Table Of Contents
Important Safety Information ....................................................................................................................2-4
Introduction ..................................................................................................................................................4
WallMaster Model Number Code and Serial Number Identication ............................................................5
Performance Data / Sleeve and Chassis Dimensions .................................................................................6
Electrical Data ..............................................................................................................................................7
Functional Components ...............................................................................................................................8
How to Operate the Electronic WallMaster Room Air Conditioner ..........................................................9-10
Remote Control ..........................................................................................................................................11
Electronic Control: Operation, Testing, Error Codes, Rebooting ..........................................................12-13
How to Operate the WallMaster with Rotary Controls, Control Testing ......................................................14
Electronic Control Heat Pump Operation ...................................................................................................15
Components Testing ..............................................................................................................................15-17
Refrigeration System Sequence of Operation ............................................................................................18
Sealed System Refrigeration Repairs / Charging ..................................................................................19-22
Hermetic Components Check ................................................................................................................23-26
Reversing Valve Description/Operation ......................................................................................................24
Testing the Coil and Reversing Valve ....................................................................................................25-26
Compressor Checks ..............................................................................................................................27-28
Compressor Replacement .....................................................................................................................29-30
Routine Maintenance .............................................................................................................................31-32
General Troubleshooting .......................................................................................................................33-39
Wiring Diagrams ....................................................................................................................................40-44
Installation Accessories ..............................................................................................................................45
Installation Instructions for “WSC” Sleeve .............................................................................................46-47
Installation Instructions for Bafe Adapter Kit .............................................................................................48
Seal Gasket Installation Instructions ...........................................................................................................49
Installation Instructions for Internal Drain Kit (IDK) .....................................................................................50
Assembly and Installation Instructions for Drain Kit (DK) ...........................................................................51
Installation Instructions for Sub-Base .........................................................................................................52
Installation Instructions for Architectural Grille Model AG-48-49 ...........................................................53-54
Warranty .....................................................................................................................................................55
1
IMPORTANT SAFETY INFORMATION
The information contained in this manual is intended for use by a qualied service technician who is familiar
with the safety procedures required for installation and repair, and who is equipped with the proper tools and
test instruments required to service this product.
Installation or repairs made by unqualied persons can result in subjecting the unqualied person making
such repairs as well as the persons being served by the equipment to hazards resulting in injury or electrical
shock which can be serious or even fatal.
Safety warnings have been placed throughout this manual to alert you to potential hazards that may be
encountered. If you install or perform service on equipment, it is your responsibility to read and obey these
warnings to guard against any bodily injury or property damage which may result to you or others.
PERSONAL INJURY OR DEATH HAZARDS
ELECTRICAL HAZARDS:
Unplug and/or disconnect all electrical power to the unit before performing inspections, •
maintenance, or service.
Make sure to follow proper lockout/tag out procedures.•
Always work in the company of a qualied assistant if possible. •
Capacitors, even when disconnected from the electrical power source, retain an electrical charge •
potential capable of causing electric shock or electrocution.
Handle, discharge, and test capacitors according to safe, established, standards, and approved •
procedures.
Extreme care, proper judgment, and safety procedures must be exercised if it becomes necessary •
to test or troubleshoot equipment with the power on to the unit.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read
and obey all safety messages.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury,
and tell you what will happen if the instructions are not followed.
This is a safety Alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol with the word “WARNING
or “CAUTION. These words mean:
You can be killed or seriously injured if you do not follow instructions.
You can receive minor or moderate injury if you do not follow instructions.
A message to alert you of potential property damage will have the
word NOTICE”. Potential property damage can occur if instructions
are not followed.
WARNING
CAUTION
NOTICE
2
Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, •
and sleeve on the room side of the air conditioning unit while cleaning.
Electrical component malfunction caused by water could result in electric shock or other electrically •
unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry.
Never operate the A/C unit with wet hands.•
Use air conditioner on a single dedicated circuit within the specied amperage rating. •
Use on a properly grounded outlet only.•
Do not remove ground prong of plug.•
Do not cut or modify the power supply cord.•
Do not use extension cords with the unit.•
Follow all safety precautions and use proper and adequate protective safety aids such as: gloves, •
goggles, clothing, adequately insulated tools, and testing equipment etc.
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death. •
REFRIGERATION SYSTEM HAZARDS:
Use approved standard refrigerant recovering procedures and equipment to relieve pressure before •
opening system for repair.
Do not allow liquid refrigerant to contact skin. Direct contact with liquid refrigerant can result in minor •
to moderate injury.
Be extremely careful when using an oxy-acetylene torch. Direct contact with the torch’s ame or hot •
surfaces can cause serious burns.
Make sure to protect personal and surrounding property with re proof materials.•
Have a re extinguisher at hand while using a torch.•
Provide adequate ventilation to vent off toxic fumes, and work with a qualied assistant whenever •
possible.
Always use a pressure regulator when using dry nitrogen to test the sealed refrigeration system for •
leaks, ushing etc.
Make sure to follow all safety precautions and to use proper protective safety aids such as: gloves, •
safety glasses, clothing etc.
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death. •
MECHANICAL HAZARDS:
Extreme care, proper judgment and all safety procedures must be followed when testing, •
troubleshooting, handling, or working around unit with moving and/or rotating parts.
Be careful when, handling and working around exposed edges and corners of sleeve, chassis, and •
other unit components especially the sharp ns of the indoor and outdoor coils.
Use proper and adequate protective aids such as: gloves, clothing, safety glasses etc.•
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death.•
3
PROPERTY DAMAGE HAZARDS
FIRE DAMAGE HAZARDS:
Read the Installation/Operation Manual for this air conditioning unit prior to operating.•
Use air conditioner on a single dedicated circuit within the specied amperage rating. •
Connect to a properly grounded outlet only.•
Do not remove ground prong of plug.•
Do not cut or modify the power supply cord.•
Do not use extension cords with the unit.•
Failure to follow these instructions can result in re and minor to serious property damage.•
WATER DAMAGE HAZARDS:
Improper installation maintenance, or servicing of the air conditioner unit, or not following the above •
Safety Warnings can result in water damage to personal items or property.
Insure that the unit has a sufcient pitch to the outside to allow water to drain from the unit. •
Do not drill holes in the bottom of the drain pan or the underside of the unit. •
Failure to follow these instructions can result in result in damage to the unit and/or minor to serious •
property damage.
4
INTRODUCTION
This service manual is designed to be used in conjunction with the installation manuals provided with each unit.
This service manual was written to assist the professional HVAC service technician to quickly and accurately
diagnose and repair any malfunctions of this product.
This manual, therefore, will deal with all subjects in a general nature. (i.e. All text will pertain to all models).
IMPORTANT:
It will be necessary for you to accurately identify the unit you are
servicing, so you can be certain of a proper diagnosis and repair.
(See Unit Identication.)
Return
Air Grille
Decorative
Front
WSC
Sleeve
AB123456C3567
MODEL# WS07A1 0B
Airflow
Rotate
Discharge
Grille
1" Diameter Plug
1” Diameter Plug
5
FRIEDRICH WALLMASTER MODEL NUMBER CODE
W S 08 B 1 0 B
1st DIGIT - FUNCTION
W = Thru-The-Wall, WallMaster Series
2nd DIGIT - TYPE
S = Straight Cool
E = Electric Heat
Y = Heat Pump
3rd & 4th DIGITS - APPROXIMATE BTU/HR (Cooling)
Heating BTU/HR capacity listed in Specications/Performance Data Section
5th DIGIT - ALPHABETICAL MODIFIER
6th DIGIT - VOLTAGE
1 = 115 Volts
3 = 230-208 Volts
7th DIGIT
0 = Straight Cool & Heat Pump Models
ELECTRIC HEAT MODELS
3 = 3 KW Heat Strip, Nominal
8th DIGIT
Major Change
Serial Number
Decade Manufactured
L=0 C=3 F=6 J=9
A=1 D=4 G=7
B=2 E=5 H=8
Year Manufactured
A=1 D=4 G=7 K=0
B=2 E=5 H=8
C=3 F=6 J=9
Month Manufactured
A=Jan D=Apr G=Jul K=Oct
B=Feb E=May H=Aug L=Nov
C=Mar F=Jun J=Sept M=Dec
L C J R 00001
Production Run Number
Product Line
X = WallMaster
SERIAL NUMBER IDENTIFICATION GUIDE
6
2008 / 2009 PERFORMANCE DATA
* Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity
Model Height Width Depth
Depth
with
Front
Minimum
Extension
Into Room
Minimum
Extension
Outside
Thru-the-wall
Finished Hole
Height Width
WSC Sleeve
Chassis
16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4"
15 3/4" 26 1/2" 21"
Sleeve / Chassis Dimensions
COOLING
PERFORMANCE
DATA*
EVAPORATOR AIR
TEMP. DEG. F
EVAPORATOR TEMP.
DEG. F
CONDENSER
TEMPERATURE
DEG. F
Discharge
Temp
Suction
Temp
Liquid
Temp
Super Heat
Sub-
Cooling
OPERATING
PRESSURES
ELECTRICAL RATINGS R-22 REF.
Evap
CFM
Motor
RPM
BREAKER
FUSE
Discharge
Air
Temp.
Drop F.
T(in) T(out) Suction Discharge Amps Cool Amps Heat
Locked Rotor
Amps
Charge in
OZ.
60 Hertz
Amps
WS08B10A-D 55 25 55 55 127 165 61 102 18 25 87 281 7.1 36.2 20.5 257 1100 15
WS08B10A-F 55 25 55 55 125 179 74.5 102 18 25 87 281 6.9 36.2 18.9 257 1100 15
WS10B10A-D 52 28 53 51 128 176 68 105 16 24 79 293 9.0 45.0 22.0 248 1100 15
WS14B10A-D 52 28 52 52 128 179 63 99 14 28 82 297 12.4 58.0 44.9 293 1300 15
WS14B10A-E 52 28 52 52 128 179 63 99 14 28 82 297 12.4 58.0 44.9 293 1300 15
WS10B30A-D 55 25 53 57 131 179 68 106 16 23 77 289 4.6 26.0 22.5 235 1100 15
WS13B30B-E 50 30 52 50 131 180 61 103 13 24 81 305 6.9/6.5 27.4 36.5 288 1280 15
WS13B30B-F 50 30 52 50 131 180 61 103 13 24 81 305 6.9/6.5 27.4 36.5 288 1280 15
WS16B30A-D 52 28 51 53 121 154 54 99 18 32 74 315 7.7 35.0 47.6 292 1421 15
WS16B30A-E 52 28 51 53 121 154 54 99 18 32 74 315 7.7 35.0 47.6 292 1421 15
WE10B33A-C 53 27 54 52 126 180 82 99 16 31 82 289 4.6 15.2 45.0 38.0 225 1074 20
WE10B33C-A 53 27 54 52 126 180 82 99 16 31 82 289 4.6 15.2 45.0 38.0 225 1074 20
WE13B33B-D 50 30 52 50 131 180 61 103 13 24 81 305 6.9/6.5 15.7 27.4 36.5 288 1280 20
WE13B33C-A 50 30 52 50 131 180 61 103 13 24 81 305 6.9/6.5 15.7 27.4 36.5 288 1280 20
WE13B33B-E 50 30 52 50 131 180 61 103 13 24 81 305 6.9/6.5 15.7 27.4 36.5 288 1280 20
WE16B33A-C 52 28 51 53 121 174 57 100 18 30 74 315 6.5 16.1 35.0 35.2 281 1305 20
WE16B33C-A 52 28 51 53 121 174 57 100 18 30 74 315 6.5 16.1 35.0 35.2 281 1305 20
WE16B33A-D 52 28 51 53 121 174 57 100 18 30 74 315 6.5 16.1 35.0 35.2 281 1305 20
WY10B33A-C 53 27 54 52
126 180 66 99 16 31 82 225 4.6 4 / 15.2 26.0 38.0 225 1074 20
WY10B33C-A 53 27 54 52 126 180 66 99 16 31 82 225 4.6 4 / 15.2 26.0 38.0 225 1074 20
WY10B33A-D 53 27 54 52 126 180 66 99 16 31 82 225 4.6 4 / 15.2 26.0 38.0 225 1074 20
WY13B33A-C 52 29 52 51 127 180 64 103 16 29 80 300 6.5 5.6 / 15.7 27.4 35.0 260 1200 20
WY13B33C-A 52 29 52 51 127 180 64 103 16 29 80 300 6.5 5.6 / 15.7 27.4 35.0 260 1200 20
WY13B33A-D 52 29 52 51 127 180 64 103 16 29 80 300 6.5 5.6 / 15.7 27.4 35.0 260 1200 20
ENERGY STAR
®
modelsSpecifications
Model
Cooling
Capacity
BTU/h
Heating
Capacity
BTU/h
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Eciency
Ratio
EER
Moisture
Removal
Pints/Hr.
Room
Side Air
Circulation Sleeve
Weight
Lbs.
Ship/Net
WALLMASTER
WS08B10A 8000 115 6.8 762 10.5 1.3 245 WSC 97/93
WS10B10A 10000 115 8.7 954 10.5 2.4 245 WSC 107/103
WS14B10A 13500 115 12.0 1415 9.5 3.3 295 WSC 116/112
WS10B30A 10000/10000 230/208 4.6/5.0 1005/996 10.0/10.0 2.1 260 WSC 105/101
WS13B30B 12500/12000 230/208 6.3/6.7 1404/1379 8.9/8.7 3.3 280 WSC 113/109
WS16B30A 15800/15000 230/208 7.8/8.5 1756/1705 9.0/8.8 4.2 290 WSC 123/119
WE10B33C 10000/10000 11000/9100 230/208 4.6/5.0 1005/996 16.0/14.7 3550/2950 10.0/10.0 2.1 260 WSC 107/103
WE13B
33C 12500/12000 11000/9100 230/208 6.3/6.7 1404/1379 16.0/14.7 3550/2950 8.9/8.7 3.3 280 WSC 115/111
WE16B33C 15800/15000 11000/9100 230/208 7.8/8.5 1756/1705 16.0/14.7 3550/2950 9.0/8.8 4.2 290 WSC 125/121
WY10B33C 10100/9800 8100/7800 230/208 4.6/4.8 1013/976 3.9/4.0 857/821 10.0/10.0 2.5 230 WSC 111/107
WY13B33C 12500/12100 10400/10000 230/208 6.4/6.8 1389/1352 5.4/5.7 1182/1136 9.0/9.0 3.2 280 WSC 120/116
7
Wire Size Use ONLY wiring size recommended for single outlet branch circuit.
Fuse/Circuit Breaker Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on units
rating plate. Proper circuit protection is the responsibiity of the homeowner.
Grounding Unit MUST be grounded from branch circuit through service cord to unit, or through separate
ground wire provided on permanently connected units. Be sure that branch circuit or general
purpose outlet is grounded.
Receptacle The eld supplied outlet must match plug on service cord and be within reach of service cord.
Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above
for proper receptacle and fuse type.
The consumer - through the AHAM Room Air Conditioner Certication Program - can
be certain that the AHAM Certication Seal accurately states the unit’s cooling and
heating capacity rating, the amperes and the energy efciency ratio.
ELECTRICAL DATA
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
installed by a qualied electrician and conform to
the National Electrical Code and all local codes
which have jurisdiction.
Failure to do so can result in personal injury or
death.
Not following the above WARNING could result in re or
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
NOTICE
FIRE HAZARD
*HACR: Heating Air Conditioning and Refrigeration
Plug/Outlet/Circuit Rating
Model Numbers
Circuit Rating
Breaker or T-D Fuse
Plug Face
(NEMA#)
Wall Outlet
Appearance
WS08B10A, WS10B10A,
WS14B10A
125V - 15A 5 - 15P
WS10B30A, WS13B30A,
WS16B30A
250V - 15A 6 - 15P
WE10, WE13, WE16
WY10, WY13
250V - 20A 6 - 20P
F
U
N
C
TI
O
NAL
CO
MP
O
NENT
S
A. Mechanical com
p
onents
Drain pan valve
Tem
p
erature-sensitive valve that o
p
ens u
p
to drain off condensate water when the outside tem
p
erature falls below 40°F
and closes when the outside temperature reaches 60°F
Plenum assembly
y
i
r with
ir
ti
n
l l
v
r
t
ir
t th
n
iti
n
ir
w
Blo
w
e
r w
heel
Attaches to the indoor side o
f
the
f
an motor sha
f
t and is used
f
or distributin
g
unconditioned, room side air thou
g
h the heat
e
xchan
g
er and deliverin
g
conditioned air into the room
.
Slinger fan blade
g
Attaches to the outdoor side o
f
the
f
an motor sha
f
t and is used to move outside air throu
g
h the condenser coil, while
slin
g
in
g
condensate water out of the base pan and onto the condenser coil, thus lowerin
g
the temperature and pressures
within th
e co
il
.
B
.
El
ectr
i
ca
l
com
p
onent
s
Th
e
rm
os
t
at
U
sed to maintain the speci ed room side comfort leve
l
System switch
y
U
sed to re
g
ulate the operation of the fan motor, the compressor or to turn the unit off. For troubleshootin
g
, refer to the
wirin
g
dia
g
rams and schematics in the back o
f
this service manual
.
Capacitor
p
R
educes line current and steadies the volta
g
e suppl
y
, while
g
reatl
y
improvin
g
the torque characteristics of the fan motor
and compressor motor.
MoneySaver
y
®
switch
®
When en
g
a
g
ed, it sends the power suppl
y
to the
f
an motor throu
g
h the thermostat, which allows
f
or a c
y
cle-
f
an operation
.
Fa
n
Mo
t
o
r
D
ual-sha
f
ted
f
an motor operates the indoor blower wheel and the condenser
f
an blade simultaneousl
y
.
So
l
e
n
o
i
d
U
sed to ener
g
ize the reversin
g
valve on all heat pump units.
Heating element
g
E
lectric resistance heater
Heat anticipator
p
U
se
d
to
p
rov
id
e
b
etter t
h
ermostat an
d
room a
i
r tem
p
erature contro
l
.
C. Hermetic com
p
onents
Compressor
p
M
otorized device used to compress re
f
ri
g
erant throu
g
h the sealed s
y
stem.
Reversing valve
g
A
f
our-wa
y
switchin
g
device used on all heat pump models to chan
g
e the
ow o
f
re
f
ri
g
erant to permit heatin
g
or coolin
g
.
C
heck valv
e
A pressure-operated device used to direct the ow of refri
g
erant to the proper capillar
y
tube, durin
g
either the heatin
g
or
c
oolin
g
c
y
cle
.
Capillary tube
p y
A c
y
lindrical meter device used to evenl
y
distribute the
ow o
f
re
f
ri
g
erant to the heat exchan
g
ers
(
coils.
)
8
How to operate the Friedrich WallMaster
Figure 1: WS Model cool-only control panel Figure 2: WY/WE Model heat-cool control panel
1
Power
2 3 4
8
Cool
Fan
Smart
9
Fan Only
6
Mode
Speed
Fan
Heat
7
Clock
5
Timer
Set
Money
Start Time
14
On/Off Saver
Stop Time
13
Temp/Hour
10 11 12
To start unit
,elc at pec er reporp a otni deggulp dna dellatsni si renoitidnoc ria ruoy fI
it is ready to go. The rst time the unit is started, the compressor will
delay for three minutes. See Automatic Component Protection on the
following page.
1
Touch the Power button once. The unit will automatically be in
Cool mode with the temperature set at 75
°
F (24
°
C) and the fan
speed at F1, the sleep setting.
To set mode of operation
When you rst turn the unit on, it will be in the Cool mode with con-
stant fan.
2
On WS cool-only models, touch the Mode buton once to activate
the MoneySaver
®
(WS models only. See item 14 for Money Saver
instructions on WY/WE models).
MoneySaver
®
is a feature that cycles the fan with the com pres -
sor so that the fan does not run all the time. This saves energy
i dim uh ed sevorpmi dna
revaSyenoM .noit ac
®
will also run to test
the temperature if the off cycle is too long. Or you may prefer
,naf tnatsnoc ot nruter oT( .tnem evom ria erom rof naf tnats noc
touch the Mode button two more times).
In order to run the fan by itself, do the following:
On WY/WS heat-cool models, touch the Mode button once to
activate the Fan Only feature. The Fan Only setting will circulate
air in the room without the compressor coming on.
3
Continuing from MoneySaver
®
mode, touch the Mode button
once to activate the Fan Only feature (WS cool-only models).
To adjust temperature
4
Use the Mode button to select either the Cool or MoneySaver
®
function (or Heat for WY/WE heat-cool models)
5
COOLER – Touch the
button to lower the room air temperature.
6
WARMER Touch the
button to raise the room air temperature.
7
Press both the
and
buttons at the same time to switch
the temperature from Fahrenheit (°F) to Celsius (°C). Repeat
Step 7 to switch from °C back to °F.
To adjust fan speed
8
Touch the Fan Speed button to see the current setting. Touch
it again to change speed. F1 i s the lowest setting (SLEEP
SETTING / LOW), F2 is MEDIUM, and F3 is HIGH.
To activate Smart Fan (WS cool-only models)
9
There is a fourth option, SF, when selecting the fan speed. This is
the SMART FAN function. SMART FAN DOES NOT OPERATE
IN CONJUNCTION WITH THE FAN ONLY MODE.
To activate Smart Fan (WY/WE heat-cool models)
9
Press the Smart Fan button to activate the Smart Fan. The light
will indicate that this feature is in use.
Smart Fan will adjust the fan speed automatically to maintain the
desired comfort level. For example, if the outside doors in your home
are opened for an extended period of time, or more people enter a
room, Smart Fan may adjust to a higher fan speed to compensate
for the increased heat load. This keeps you from having to adjust
the fan speed on your own.
To set the hour clock
10
Touch the Set Hour b utton to see the c urrent setting. The
.)ylno ruoh( emit etamixorppa eht si deyalpsid si taht rebmun
Use the
and buttons to change the settings. BE SURE
TO SET A.M. AND P. M. ACCORDINGLY. (P. M. is indicated by
a red light in the upper left corner of the display).
9
To set the timer
NOTE: Set the HOUR CLOCK (Set Hour) before attempting to set
timer functions.
You can set the Start Time and Stop Time a minimum of one hour
apart, and a maximum of 23 hours apart.
11
After setting the time, press the Set Hour button once (Start
light on). Use the
and
eht taht emit eht tceles ot snottub
unit will START.
12
After selecting the Start Time, press the Set Hour button once.
(Stop Light on). Use the
and
buttons to select the time
that the unit will STOP. After selecting the stopping time, press
the Set Hour button once.
13
Press the Timer On/Off button (light turns on) to activate the
timer function. To deactivate this function, press the Timer On/
Off button once again (light turns off). Once the on and off times
have been selected, they will remain in memory and cycle daily
until changed.
NOTE: If the unit is unplugged or the power is interrupted, the HOUR
must be reset or the Timer On/Off will not function when desired.
To Activate Money Saver (WY/WE models)
14
Press the Money Saver button to activate the Money Saver
feature. The light will indicate the Money Saver is in use.
MoneySaver
®
is a feature that cycles the fan with the com pres
sor so that the fan does not run all the time. This saves energy
i fidim uh ed sevorpmi dnarevaSyenoM .noit ac
®
will also run to test
the temperature if the off cycle is too long. Or you may prefer
,naf tnatsnoc ot nruter oT( .tnem evom ria erom rof naf tnats noc
touch the Mode button two more times).
Automatic component protection
Your unit is equipped with Automatic Component Protection.
To protect the compressor of the unit, there is a three minute delay
if you turn the unit off or if power is interrupted. The fan will not be
affected. Also, if you switch from Cool mode to Fan Only mode, and
switch back to Cool mode, there is a three-minute delay before the
compressor comes back on.
10
Figure 3: WY/WE heat-cool model remote control
Additional RC1 wireless remote controls can be purchased from your Friedrich dealer.
Figure 4: WS Models Only
Additional RC1 wireless remote controls can be purchased from your Friedrich dealer.
Using the remote control
To start unit
1
POWER - Press the Power button once. The unit will automatically
start in the mode and fan speed it was last left on.
To set mode of operation
2
COOL - Press the Cool button to automatically switch the operat-
ing mode to COOL.
3
FAN ONLY - Press the Fan Only button if you want to run the
fan only.
4
HEAT (WY/WE m odels only) - Press t he Heat b utton to
automatically switch the operating mode to HEAT.
5
MoneySaver
®
- Press the Money Saver
®
button to activate
the MoneySaver
®
feature. This feature cycles the fan with the
compressor so that the fan does not run all the time.
To adjust temperature
6
WARMER - Press the
Warmer button to raise the temperature sett
tt
ing.
ing.
7
COOLER - Press the
Cooler button to lower the temperature se
To adjust fan speed
8
FAN SPEED - Press the Fan Speed button to see the current
setting. Press again to change the fan speed. F1 is the lowest
setting (SLEEP / LOW), F2 is MEDIUM, F3 is HIGH, and SF is
the SMART FAN setting.
To set the hour clock
9
SET HOUR CLOCK - Press the Set Hr. button once to see the
current clock setting. Continue pressing the button until you
arrive at the current time (Hour only). Minutes are not shown on
the display. Make sure that the A.M. / P. M. setting is correct.
To set the timer
NOTE: You can set the START and STOP times a minimum of one
hour apart, and a maximum of 23 hours apart.
10
TIMER START - Press Start to view the current start time for cool-
ing. Continue pressing the START button until you arrive at the start
time you desire. The start time for cooling will then be set.
11
TIMER STOP - Press the Stop button. Continue pressing the
STOP button until you arrive at the stop time you desire. The
stop time for cooling will then be set.
12
TIMER ON / O FF - P ress t he O n/Off b utton (under Timer
Operation .remit eht )ffo thgil( etavitcaed ro )no thgil( etavitca ot )
Once the on and off times have been selected, they will remain
in memory and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the Set Hr.
function must be reset or the Timer On/Off function will not work.
11
ELECTRONIC CONTROL PANEL
CHECKING ROOM TEMPERATURE
1. Check the room temperature at the electronic control
pad by pressing at the same time, the Fan Speed
button and the Temp/Hour button on the WS/WE/
WY models (see gures 5 and 6).
2. The indoor temperature will display for 10 seconds.
Indoor temperature can be viewed in all modes, including
the Test Mode. The display can be changed back to
the SET temperature by pressing any key (except the
Power (on/off button) or it can do so automatically after
10 seconds have elapsed.
ACTIVATING TEST MODE
Activate Test Mode by pressing at the same time, the Mode
button and the Temp/Hour button on on the WS/WE/
WY models (seegures 5 and 6).
The LEDs for Set/Hour: Star t Time and “Stop Time” will
blink 1 bps while Test Mode is active.
Test Mode has a duration of 90 minutes. Test Mode can be
activated under any function, including Off.
Test Mode is cancelled by pressing the Power (on/off)
button, unplugging the unit, or when the 90 minutes times
out.
Test Mode settings are factory default of:
Unit operation On, MoneySaver On, Cool Mode, 60
degrees F, speed fan on High. “Timer” and “Set Hour
features are non-functional.
Test Mode overrides the three minute compressor Lock-
out, all delays for fan motor start, speed change, and when
switching modes.
TESTING THE ELECTRONIC CONTROL
Figure 5: “WS” Cooling only models
Electronic Control Panel
Temp/Hour
Cool
Money Saver
®
Fan Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
PM
Timer
On/Off
Set
Hour
72
Figure 6: “WE”/WY” heat/cool models
Electronic Control Panel
Error Code Mode is used to display all error codes
stored since reset. It is a sub-mode of Test Mode. Unit
must be in Test Mode to enter the Error Code function.
Activating Error Code Mode: Press the TIMER On/
Off button on the WS/WE/WY models (see gures 5
and 6). The LED for the TIMER On/Off will ash 1 bps
(beats per second) while Error Code Mode is active.
Pressing the Temp/Hour button will display “00”.
Consecutive presses will scroll through all error codes
stored. Press the Temp/Hour button to see the
reverse order of the error codes. When the end of the
stored error codes is reached the temperature Set Point
will appear. (Each error code is listed once)
Exiting Error Code Mode: press the Timer On/Off
button.
Clearing Error Codes: Error codes are cleared
from the memory by exiting from Error Code Mode.
MEMORY: On WS/WE/WY
The electronic control has a memory to retain all
functions and settings, as set up by the user, in the event
of a power failure. For example: once power is restored
to the unit, there is a two second delay before the fan
comes on and approximately three minutes delay before
the compressor is activated providing that the mode was
set for cooling and the set point temperature has not
been met in the room.
ERROR CODE MODE
12
ERROR CODES LISTING FOR “WS” MODELS
E1 SHORT CYCLE SITUATION: Dened as a
compressor that starts and stops more frequently
than it should.
E2 KEYBOARD STUCK ERROR: If any key button
is stuck or pressed for 20 seconds or more, the
unit considers it stuck. If a key is stuck it will be
ignored until released. If the “Mode” key is stuck,
the units function will default to Cool mode.
E3 FROST PROBE OPEN: Normal operation is
allowed. Ohm frost probe. Replace if Ohm value
not read. If Ohm value is present replace the
board.
E4 FROST PROBE SHORT: Normal operation is
allowed. Replace probe.
E5 INDOOR PROBE OPEN: Control assumes
indoor ambient temperature is 90 degrees F and
unit will operate. Ohm indoor probe. Replace
probe if Ohm value is not present.
E6 INDOOR PROBE SHORT: Control assumes
ambient temperature is 90 degrees F and unit
will operate. Replace probe.
(See note and other infomation below)
ERROR CODES LISTING FOR “WE/WY” MODELS
E1 SHORT CYCLE SITUATION: Dened as a
compressor that starts and stops more frequently
than it should.
E2 KEYBOARD STUCK ERROR: If any key button
is stuck or pressed for 20 seconds or more, the
unit considers it stuck. If a key is stuck it will be
ignored until released. If the “Mode” key is stuck,
the units function will default to Cool mode.
E3 AMBIENT (INDOOR) AIR PROBE OPEN
OR SHORT: Control will assume ambient
temperature is 90 degrees F when in Cool mode
and 60 degrees F when in Heat mode. Unit will
operate (see note below).
E4 EVAPORATOR TEMPERATURE PROBE
OPEN OR SHORT: Normal operation is allowed.
Replace probe (see note below).
E5 CONDENSER TEMPERATURE PROBE
OPEN OR SHORT: Normal operation is allowed.
Replace probe.
E7 MOTOR OPERATION
E9 HEAT PUMP FAILURE
NOTE: All error codes display for probes open or shorted will
allow unit to operate. Unit may ice up if faulty components
are not replaced.
Indoor Coil Frost Probe Sensor (WS/WE/WY Models):
Disables compressor at 30 degrees F+/- 3 degrees
F. Compressor resumes operation when indoor coil
temperature reaches 55 degrees F.
Outdoor Coil Frost Probe Sensor (on WY models):
Disables the compressor at 30 degrees F. Compressor
resumes operation when temperature reaches 43 +/- 5
degrees F.
Indoor Air Probe Sensor (WS/WE/WY Models):
Control range is 60 degrees F to 90 degrees F +/- 3
degrees F.
REBOOT THE CONTROL PANEL
To reboot the control panel on a WallMaster unit: with the
unit on, simultaneously hold down the Mode button and
the Temperature Arrow button for approximately 10
seconds. If the panel will reboot, you will hear the fan come
on and the temperature window will read 60 degrees. If this
happens, all you need to do is turn the unit off for about 10
seconds and then turn it back on to nish the reboot cycle. If
the panel does not reboot, you will most likely need to have
the panel replaced.
13
Figure 8: System Control Switch
(Heat Pump & Electric Heat Models)
Fan
Only
Off
Low
Cool
Low
Heat
Med
Cool
Med
Heat
High
Heat
High
Cool
MAX
HEAT
MAX
COOL
!
Allow 3 min. between restarts
SYSTEM CONTROL SWITCH - TEST
Disconnect leads from control switch. Turn control to
position being tested (see Figure 8). There must be
continuity as follows:
1. “Off” Position-no continuity between terminals.
2. “Lo Cool” Position-between terminals “C” and “3”,
“C2” and “2”, “LO” and “M/S”, “AR” and “5”.
3. “Med Cool” Position-between terminals “C” and
“3”, “C2” and “2”, “M” and “M/S”, “AR” and “5”.
4. “Hi Cool” Position-between terminals “C” and “3”,
“C2” and “2”, “H” and “M/S”, “AR” and “5”.
5. “Hi Heat” Position-between terminals “C” and “1”,
“C2” and “4”, “H” and “M/S”, “AR” and “5”.
6. “Med Heat” Position-between terminals “C” and
“1”, “C2” and “4”, “M” and “M/S”, “AR” and “5”.
7. “Lo Cool” Position-between terminals “C” and “1”,
“C2” and “4”, “LO” and “M/S”, “AR” and “5”.
8. “Fan Only” Position-between terminals “L1”, “M”
and “2”.
FOR UNITS WITH ROTARY CONTROLS
SYSTEM CONTROL SWITCH
(“WE” & “WY” Models) An eight position switch is used to
regulate the operation of the fan motor, compressor and
electric heater.
The unit can be operated in cooling or heating mode with
rotom naf eht dna no retaeh cirtcele ro rosserpmoc eht
operating on low, medium or high speed.
The fan motor can also be operated independently on
medium speed. See switch section as indicated on
decorative control panel, in Figure 7.
Figure 7: System Control Panel
NOTE:
Units will operate in constant fan in the cooling mode
and auto fan in the heating mode.
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
14
15
ELECTRONIC CONTROL
OPERATION
Heat Pump w/back up Electric Heat
If the indoor ambient air themister reads 55 degrees,
turn off the compressor and turn on the electric heat and
continue fan operation until temp setting is satised. Then
revert to standard heat pump operation.
If the compressor is time delayed:
1. Turn on the electric heat until the compressor is not time
delayed.
2. When the compressor’s 3 minute time delay is over,
turn off the electric heat, wait 5 seconds, then turn on the
compressor.
Defrost:
If the outdoor coil thermister reads 30 degrees for 2
minutes continuously, turn off the compressor and turn on
the electric heat and continue fan operation.
If the outdoor coil thermister reaches 43 degrees and
the compressor has waited the standard delay time of
180-240 seconds:
1. Turn off the backup electric heat
2. Wait 5 seconds
3. Turn on the compressor
4. Continue fan operation.
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
COMPONENTS TESTING
THERMOSTAT
(“WE” & “WY” Models)
A cross ambient thermostat is used on all electric heat and
heat pump WallMaster models (see Figure 9).
Range from 60° F (±2° F) to 92° F (±2° F).
TEST:
Remove wires from thermostat and check continuity
between terminal “2” (common) and “1” for heating. Also
check that contacts in thermostat open after placing in
either position. NOTE: Temperature must be within range
listed to check thermostat.
Figure 9 : Thermostat
THERMOSTAT ADJUSTMENT
No attempt should be made to adjust thermostat. Due to
the sensitivity of the internal mechanism and the sophis-
ticated equipment required to check the calibration, it is
suggested that the thermostat be replaced rather than
calibrated.
FAN MOTOR - TEST
1. Determine that capacitor is serviceable.
2. Disconnect fan motor wires from fan speed switch or
system switch.
3. Apply “livetest cord probes on black wire and common
terminal of capacitor. Motor should run at high speed.
4. Apply “livetest cord probes on red wire and common
terminal of capacitor. Motor should run at low speed.
5. Apply “live” test cord probes on each of the remaining
wires from the speed switch or system switch to test
intermediate speeds. If the control is in the “MoneySaver”
mode and the thermostat calls for cooling, the fan will
start - then stop after approximately 2 minutes; then the
fan and compressor will start together approximately 2
minutes later.
Fan Motor
FAN MOTOR
A single phase permanent split capacitor motor is used to drive
the evaporator blower and condenser fan. A self-resetting
overload is located inside the motor to protect against high
temperature and high amperage conditions. (See Figure 23)
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
16
CAPACITORS
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before servicing.
Discharge capacitor with a 20,000 Ohm 2 Watt
resistor before handling.
Failure to do so may result in personal injury,
or death.
Many motor capacitors are internally fused. Shorting the
terminals will blow the fuse, ruining the capacitor. A 20,000
ohm 2 watt resistor can be used to discharge capacitors
safely. Remove wires from capacitor and place resistor
across terminals. When checking a dual capacitor with
a capacitor analyzer or ohmmeter, both sides must be
tested.
Capacitor Check with Capacitor Analyzer
The capacitor analyzer will show whether the capacitor is
“open” or “shorted.” It will tell whether the capacitor is within
its micro farads rating and it will show whether the capacitor
is operating at the proper power-factor percentage. The
instrument will automatically discharge the capacitor when
the test switch is released.
Capacitor Connections
The starting winding of a motor can be damaged by a
shorted and grounded running capacitor. This damage
usually can be avoided by proper connection of the running
capacitor terminals.
From the supply line on a typical 230 volt circuit, a 115 volt
potential exists from the “R” terminal to ground through a
possible short in the capacitor. However, from the “S” or
start terminal, a much higher potential, possibly as high as
400 volts, exists because of the counter EMF generated
in the start winding. Therefore, the possibility of capacitor
failure is much greater when the identied terminal is
connected to the “S” or start terminal. The identied
terminal should always be connected to the supply line, or
“R” terminal, never to the “S” terminal.
When connected properly, a shorted or grounded running
capacitor will result in a direct short to ground from the “R”
terminal and will blow the line fuse. The motor protector
will protect the main winding from excessive temperature.
Dual Rated Run Capacitor Hook-up
DEFROST THERMOSTAT
(“WY” Electromechanical Control Models Only)
This thermostat is a single pole - double throw with con-
tacts between terminal “2” and “3” closing on temperature
rise and contacts between terminals 2” and “1closing
on temperature fall. When the contacts between terminals
“2” and “3” open, power to the compressor is interrupted.
When contacts between terminals “2” and “1” make, power
is suppled to the heater element.
This control is a dual purpose control that acts as an
outdoor thermostat and defrost control.
When the sensing bulb, attached to the condenser coil,
senses enough icing on the outdoor coil it will interrupt
power to the compressor and supply power to the heating
Figure 10: Defrost Control
DEFROST BULB LOCATION
(All “WY” Electromechanical Control Models)
The defrost control bulb must be mounted securely and in
the correct location to operate properly (see Figure 11).
Figure 11: Defrost Bulb Location
(All “WY” Models)
element until the coil temperature reaches above 43°.
Then the heater will shut off and the unit will resume
operating in the reverse cycle mode.
When the outdoor coil temperature drops below 20 degrees,
the unit will operate in electric heat mode continuously until
the outdoor coil temperature rises above 43°.
H
C
F
17
DRAIN PAN VALVE
During the cooling mode of operation, condensate which
collects in the drain pan is picked up by the condenser
fan blade and sprayed onto the condenser coil. This as-
sists in cooling the refrigerant plus evaporating the water.
During the heating mode of operation, it is necessary that
water be removed to prevent it from freezing during cold
outside temperatures. This could cause the condenser
fan blade to freeze in the accumulated water and prevent
it from turning.
To provide a means of draining this water, a bellows type
drain valve is installed over a drain opening in the base
pan. This valve is temperature sensitive and will open
when the outside temperature reaches 40°F. The valve
will close gradually as the temperature rises above 40°F
to fully close at 60°F.
Drain Pan Valve
Figure 12: Heating Element
HEATING ELEMENT
(“WE” &”WY” Electronic and Electromechanical Models)
All “WE” and “WY” models are equipped with a 3.3 KW
heating element.
The heating element has two heater limit switches
(bimetal thermostats) connected in series with it. The
number 1 limit located near the bottom, will open the
circuit when the temperature reaches 130°F +/-5°. The
number 2 is a high limit switch near the top of the
element. It is designed to open the circuit at 165°F +/-.
Should the fan motor fail or filter become clogged etc.,
the high limit switch will open and interrupt the power to
the heater before reaching an unsafe temperature
condition.
Test the heater element for continuity below 130°F. The
element’s resistance value is 13.7 Ohms +/-5%.
Not actual element - for reference only
Suction
Line
Evaporator
Coil
Metering
Device
Refrigerant
Strainer
Discharge
Line
Condenser
Coil
Compressor
Refrigerant Drier
Liquid
Line
A good understanding of the basic operation of the
refrigeration system is essential for the service technician.
Without this understanding, accurate troubleshooting of
refrigeration system problems will be more difcult and time
consuming, if not (in some cases) entirely impossible. The
refrigeration system uses four basic principles (laws) in its
operation they are as follows:
1. “Heat always ows from a warmer body to a cooler
body.”
2. “Heat must be added to or removed from a substance
before a change in state can occur”
3. “Flow is always from a higher pressure area to a lower
pressure area.”
4. “The temperature at which a liquid or gas changes state
is dependent upon the pressure.”
The refrigeration cycle begins at the compressor. Starting
the compressor creates a low pressure in the suction line
which draws refrigerant gas (vapor) into the compressor.
The compressor then “compresses” this refrigerant, raising
its pressure and its (heat intensity) temperature.
The refrigerant leaves the compressor through the discharge
Line as a hot High pressure gas (vapor). The refrigerant
enters the condenser coil where it gives up some of its
heat. The condenser fan moving air across the coil’s nned
surface facilitates the transfer of heat from the refrigerant to
the relatively cooler outdoor air.
When a sufcient quantity of heat has been removed from
the refrigerant gas (vapor), the refrigerant will “condense”
(i.e. change to a liquid). Once the refrigerant has been
condensed (changed) to a liquid it is cooled even further by
the air that continues to ow across the condenser coil.
The WallMaster design determines at exactly what point (in
the condenser) the change of state (i.e. gas to a liquid)
takes place. In all cases, however, the refrigerant must be
totally condensed (changed) to a Liquid before leaving the
condenser coil.
The refrigerant leaves the condenser Coil through the liquid
line as a warm high pressure liquid. It next will pass through
the refrigerant drier (if so equipped). It is the function of the
drier to trap any moisture present in the system, contaminants,
and large particulate matter.
The liquid refrigerant next enters the metering device. The
metering device is a capillary tube. The purpose of the
metering device is to “meter” (i.e. control or measure) the
quantity of refrigerant entering the evaporator coil.
In the case of the capillary tube this is accomplished (by
design) through size (and length) of device, and the pressure
difference present across the device.
Since the evaporator coil is under a lower pressure (due to
the suction created by the compressor) than the liquid line,
the liquid refrigerant leaves the metering device entering the
evaporator coil. As it enters the evaporator coil, the larger
area and lower pressure allows the refrigerant to expand
and lower its temperature (heat intensity). This expansion is
often referred to as “boiling”. Since the unit’s blower is moving
indoor air across the nned surface of the evaporator coil,
the expanding refrigerant absorbs some of that heat. This
results in a lowering of the indoor air temperature, hence the
“cooling” effect.
The expansion and absorbing of heat cause the liquid
refrigerant to evaporate (i.e. change to a gas). Once the
refrigerant has been evaporated (changed to a gas), it is
heated even further by the air that continues to ow across
the evaporator coil.
The particular system design determines at exactly what
point (in the evaporator) the change of state (i.e. liquid to a
gas) takes place. In all cases, however, the refrigerant must
be totally evaporated (changed) to a gas before leaving the
evaporator coil.
The low pressure (suction) created by the compressor
causes the refrigerant to leave the evaporator through the
suction line as a cool low pressure vapor. The refrigerant then
returns to the compressor, where the cycle is repeated.
REFRIGERATION SYSTEM SEQUENCE OF OPERATION
18
/