Danfoss KE04201 Valve Drive Amplifier Installation guide

Type
Installation guide
1 OF 1
POLARITY OF BATTERY CONNECTIONS MAY BE REVERSED TO
CHANGE ACTION OUTPUT VERSUS SENSOR INPUT
GAIN SWITCH IS OPTIONAL. JUMPERS MAY BE USED IN PLACE
OF SWITCH
1
GAIN SWITCH
ACX104C
POTENTIOMETER
ROTARY POSITION
SENSOR
BATTERY
OUTPUT TO 30 LOAD
2
3
4
5
6
7
8
9
10
MED
LOW
HIGH
+
-
+
-
NO CONNECTION
Unit Specification
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763) 559-0108
ISSUE: 3 DATE: September 1996
KE04201
Valve Drive Amplifier
GENERAL DESCRIPTION
DIMENSIONS
OUTPUT CHARACTERISTICS
CONNECTION DIAGRAM
The device is a free–standing amplifier mounted on 4 standoffs. Voltage from a sensor potentiometer, through the amplifier,
produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals. An external switch
can change gain settings by shorting between two terminals.
SUPPLY VOLTAGE
24 Vdc (22 to 30 Volts)
TURN ON VOLTAGE
48% of supply
MAXIMUM OUTPUT CURRENT
600 mA to 30 Load
12,70
(0.50)
9,65
(0.38)
5,33 (0.21) INSIDE DIA.
76,20
(3.00)
57,15
(2.25)
6,35
(0.25)
114,30 (4.50)
101,60 (4.00)
KE04201
VALVE
DRIVE
AMPLIFIER
K14512 UNIT SPEC
ange.
1647
Dimensions of the KE04201 in Millimeters (Inches).
1648
1649A
10
20
30
40
50
60
70
80
90
100
10 20 30 40 50 60 70 80 90 100
% MAXIMUM
OUTPUT VOLTAGE
HIGH GAIN
MED GAIN
LOW GAIN
% SUPPLY VOLTAGE
© Danfoss, 2013-09 K14512 UNIT SPEC 1