Sennheiser SZI 1029 User manual

Type
User manual

This manual is also suitable for

1
SZI 1029
SZI 1029-10
BEDIENUNGSANLEITUNG
INSTRUCTIONS FOR USE
NOTICE D‘EMPLOI
ISTRUZIONI PER L‘USO
INSTRUCCIONES PARA EL USO
GEBRUIKSAANWIJZING
2
3
Bedienungsleitung ................................. 4
Instructions for use ............................... 22
Notice d‘emploi ............................... 40
Istruzioni per l‘uso ............................... 58
Instrucciones para el uso ............................... 76
Gebruiksaanwijzing ............................... 94
SZI 1029
SZI 1029-10
22
23
INSTRUCTIONS FOR USE Available Models .............................. 24
Overview .............................. 25
Operating elements .............................. 26
Connecting several radiators
Starting with an infra-red modulator .............................. 27
Infra-red technology .............................. 28
Wideband .............................. 28
Narrow-band .............................. 28
Areas of application .............................. 28
Propagation of infra-red light .............................. 29
Impact of curtains, carpets, and paints .............................. 29
Impact of extraneous light .............................. 30
Radiating power .............................. 30
Radiating power during multi-channel operation .............................. 30
Computing the radiating power .............................. 31
Propagation of infra-red light .............................. 31
Putting the radiator into operation .............................. 32
Mains connection .............................. 32
Connecting an IR radiator .............................. 33
Single/Multi-channel operation .............................. 33
Cancellation with greater cable lengths .............................. 34
Malfunction indicator .............................. 35
Operation indicator .............................. 35
Distance between radiators and receivers .............................. 35
Installation .............................. 35
Suitable modulators .............................. 36
Suitable receivers .............................. 36
Mechanical accessories .............................. 37
Electrical accessories .............................. 38
N.B.: „Infra-red Planning Brochure“
from Sennheiser .............................. 38
Technical Specifications .............................. 39
CONTENTS
24
25
OVERVIEW
SZI 1029-EU X X X X X X 03664
SZI 1029-EU-W X X X X X X 04076
SZI 1029-10-EU X X X X X X 04005
SZI 1029-120 X X X X X X 04078
SZI 1029-10-120 X X X X X X 04006
SZI 1029-UK X X X X X X 04077
SZI 1029-24 X X X X X X 04079
Black housing
Unpainted aluminium housing
Wideband transmission
Narrow-band transmission
Connection via a modulator
IR radiating power 5 W
IR radiating power 10 W
Supplied with European mains lead
Supplied with a UK mains lead
Supplied with a USA mains lead
24 V DC operation
Catalogue Number
AVAILABLE MODELS
SZI 1029 EU High Power IR Radiator for wideband and narrow-band
operation together with a suitable modulator. Infra-red
radia-ting power 5 W, single-channel (MONO) or multi-channel (MUlTI)
operation. BNC output socket for connection of additional SZI 1029 or
SZI 1015 radiators. Black housing. Supplied with a European mains cable.
SZI 1029-EU-W As SZI 1029-EU but white with unpainted aluminium housing.
SZI 1029-120 As SZI 1029-EU but supplied with a USA mains cable.
SZI 1029-UK As SZI 1029-EU but supplied with a UK mains cable.
SZI 1029-24 As SZI 1029-EU but for 24 V DC supply.
SZI 1029-24-W As SZI 1024 but white with unpainted aluminium housing.
SZI 1029-10-EU-B As SZI 1029-EU but with 10 W infra-red radiating power.
SZI 1029-10-EU-W As SZI 1029-EU-B but white with unpainted aluminium housing.
SZI 1029-10-US-B As SZI 1029-EU-B but supplied with a USA mains cable.
SZI 1029-10-120-W As SZI 1029-10-EU but supplied with a USA mains cable,
white with unpainted aluminium housing.
26
27
MONO MULTI
CHANNEL
OUTPUTINPUT
MONO MULTI
CHANNEL
OUTPUTINPUT
MONO MULTI
CHANNEL
OUTPUTINPUT
MONO MULTI
CHANNEL
OUTPUTINPUT
ì”°
ì”°
OPERATING ELEMENTS
The side parts of the
housing serve as heat sinks. Do
not cover the openings at the
top and the bottom!
Green LED,
operation indicator
Red LED, mains supply
indicator and warning light for
reduced IR radiating power
(malfunction indicator)
Selector switch for single
channel (MONO)/multi-channel
(MULTI) operation
BNC infra-red input socket
BNC output socket for
connecting further radiators
Thread for mounting the
radiator
IEC mains connector
24 V DC input socket (only with
1029-24 model)
CONNECTING SEVERAL
RADIATORS
WIDEBAND AND NARROW-BAND TRANSMISSION, SINGLE-CHANNEL
AND MULTI-CHANNEL
Starting with an infra-red
modulator
BNC/BNC cable (RG 58, 50 Ω):
GZL 1019 A1, -5, -10
Additional SZI 1029...
ì”°
Connect a terminating impedance
50 Ω to the out-put BNC
socket of the last radiator.
SZI 1029 SZI 1029
28
29
INFRA-RED TECHNOLOGY The SZI 1029 is a high power infra-red radiator. In a cordless infra-red
sound transmission system it transforms the electrical signal delivered
by an infra-red modulator or by an audio source into invisible infra-red
light and radiates this IR light into a room. In contrast to radio
transmission infra-red transmission is limited to the room, thus other
systems can be operated in neighbouring rooms without interference.
ì”° The high-power radiator SZI 1029 is switched on by the IR carrier
signal that is produced by the modulator. Commercially available
50 Ω coaxial cables with BNC connectors are used for feeding
sig nals from the modulator to the SZI 1029 radiator.
The infra-red radiator diodes in the high power radiator respond to the
received signals and radiate modulated infra-red light. Depending on
the model the radiator delivers a radiating power of 5 or 10 W
(see
AVAILABLE MODELS).
WIDEBAND Infra-red wideband transmission systems are chiefly used for transmitting
audio signals in hi-fi quality.
The two available wideband channels (2.3 MHz and 2.8 MHz) are
internationally standardized and are either used for two mono channels
or for stereo transmission.
NARROW-BAND Infra-red narrow-band transmission systems allow the transmission of
up to 32 mono channels with a slightly reduced audio frequency response.
They are ideal for multi-channel interpretation systems and multilingual
information systems.
AREAS OF APPLICATION
ì”° Conference and simultaneous interpretation systems
ì”° High quality cordless sound transmission in recording studios
or for hi-fi systems
IMPACT OF CURTAINS,
• Dark and heavy materials, curtains, carpets, panellings, and wall
CARPETS, AND PAINTS coverings tend to absorb the light, a good reception can only be
achieved in direct line of sight of the infra-red radiator.
• Roughcast and strongly structured wallpapers (such as woodchip,
embossed or fabric papers) reflect the light unevenly but allow a
more uniform propagation of the infra-red signal.
• Smooth and bright walls, smooth tiled floors and windows are
highly reflective and are thus favourable for the propagation of in
fra-red light.
• Different wall paints may reflect infra-red light differently although
they have the same colour. This is due to the type and thecomposit-
ion of the paint pigmentation.
The power which is necessary to irradiate a room varies accordingly.
IR-Licht
Reflexion
IR-Licht
Reflexion
IR-Licht
Reflexion
IR light IR light
IR light
Reflection Reflection Reflection
PROPAGATION OF The propagation of the infra-red signal radiated by the SZI 1029 can be
INFRA-RED LIGHt compared to the propagation of normal daylight or artifical (lamp) light.
Thus it is subject to similar conditions when it falls onto different
materials:
30
31
IR-Licht
Fremdlicht
IR-Licht
Fremdlicht
650
Grundfläche in m
2
x Anzahl der Kanäle
Number of radiators (SZI 1029) =
Number of radiators (SZI 1029-10) =
IMPACT OF EXTRANEOUS LIGHT Daylight and artificial light in a room also have an impact on the IR
reception. Since the spectrum of this light also contains infra-red portions
it can interfere with the useful signal radiated by the SZI 1029. At worst,
the reception is disturbed by hissing noise.
Extraneous light
IR light
Extraneous light
IR light
RADIATING POWER
Number of channels
Example: 12
RADIATING POWER DURING (Not for SZI 1029-T models) The number of transmitted channels has
MULTI-CHANNEL OPERATION an impact on the radiated power of the infra-red radiator SZI 1029.
The power is uniformly divided in such a way that, for instance, in a
system with 12 narrow-band channels only 1/12 of the desired radiating
power is available for each audio channel.
surface area in sq. m. x number of channels
1300
COMPUTING THE During single channel operation (switch set to MONO), every
RADIATING POWER SZI 1029 radiator will supply an area of about 1000 sq.m.
The SZI 1029-10 radiators are able to supply approximately double
this area.
When switched to narrow-band multi-channel operation (switch set to
MULTI) power output and thus irradiated area are reduced by
approximately 35 % (see
RADIATING POWER DURING MULTICHANNEL
OPERATION).
A simple formula facilitates the calculation of the number of radiators
necessary to irradiate a given room:
surface area in sq. m. x number of channels
RULE OF THUMB
PROPAGATION OF The high power radiator SZI 1029 radiates the infra-red light in a lobar
INFRA-RED LIGHT shape. With increasing distance the intensity becomes weaker. When a
receiver leaves the irradiated area the transmission is interrupted. Recei
vers without squelch will produce a hissing noise, receivers with squelch
will mute.
110m
100m
90m
80m
70m
60m
50m
40m
30m
20m
10m
120m
130m
140m
150m
20Ëš
10Ëš
30Ëš
40Ëš
50Ëš
60Ëš
70Ëš
80Ëš
90Ëš
20Ëš
10Ëš
30Ëš
40Ëš
50Ëš
60Ëš
70Ëš
80Ëš
90Ëš
26dB
40dB
32
33
MONO MULTI
CHANNEL
OUTPUTINPUT
IR input BNC
MONO MULTI
CHANNEL
PUTTING THE RADIATOR Insert the mains connector and secure it with the steel clamp.
INTO OPERATION
MAINS CONNECTION
Install the SZI 1029 high power radiator in a vertical (or almost vertical)
position. The cables are guided downwards.
The vertical position ensures sufficient cooling of the radiator - air can
circulate through the cooling fins that are integrated into the sides of the
radiator.
The SZI 1029 high power radiator is provided with an interchangeable
thread for mounting it to stands with 3/8" or 1/2 „threads using an adaptor
(included in the scope of delivery).
CONNECTING AN IR RADIATOR After having connected the radiator to the mains, the IR input of the
SZI 1029 has to be connected to the IR output of the modulator.
Several co-axial cables are available for this purpose (see ELECTRICAL
ACCESSORIES). The cables can be connected to one another using a
BNC coupler GZV 1019 A.
IR output BNC for extension radiators
For permanently installed systems you should use commercially available
50 Ω coaxial cables, such as RG 58 (75 Ω cables can be used if 50 Ω
cables are unavailable). If you want to use several SZI 1029 radiators
you have to connect them in series. This is done by connecting the output
BNC socket of the first radiator with the IR input BNC socket of the
second radiator. A maximum of 100 radiators can be connected in series.
The maximum total length of the cable should not exceed 1500 m.
After having connected the last radiator you can put the transmission
system into operation by switching on the modulator. It transmits a carrier
signal which automatically switches on the radiators. When the carrier
signal stops, the radiators switch off automatically.
N.B.: In order to avoid standing waves a terminating impedance of 50 Ω
should be connected to the last radiator (or 75 Ω terminating impedance
if 75 Ω cable was used).
SINGLE-CHANNEL/MULTI-
CHANNEL OPERATION
Selector switch single-
channel (Mono)/multi-
channel (Multi)
34
35
Green LED,
operation
red LED, mains supply indicator
and warning light for reduced
IR radiating-power
(malfunction indicator)
MALE TWO CHAINS!
RISK OF CANCELLATION!
CANCELLATION WITH The length of the cable between two neighbouring radiators should not
GREATER CABLE LENGTHS exceed 75 m, otherwise signal cancellation can occur when the radiation
is not in phase! Do not forget the terminating impedance!
The SZI 1029 high power radiator is provided with 12 independent output
stages, each stage amplifies the received signal for a power block of 12
infra-red LEDs. The SZI 1029-10 models with 24 independent output
stages have double the power.
MALFUNCTION INDICATOR If one power block fails, transmission quality is not considerably affected.
Only if more than one third of all the blocks fail to operate, the red LED
will light up in addition to the green one, thus indicating that the device
will have to be repaired.
OPERATION INDICATOR
The indicators work as follows:
Red Indicator Only: The
radiator is connected to the
mains but there is no IR signal
present. Green Indicator Only:
IR signal is present, the
radiator is working normally.
Red & Green Indicator:FAULT
CONDITION! 30 % or more of
the diodes are not working and
the radiator should be returned
to your local Sennheiser agent
for repair.
DISTANCE BETWEEN Please observe a minimum distance of 2 m between radiators and
RADIATORS AND RECEIVERS receivers as otherwise the receiver input stage could be overloaded. This
would result in a very poor transmission quality.
INSTALLATION If possible the radiators should be installed in such a way that they are
directly orientated towards the infra-red receivers. For best reception the
radiators should be installed as high as possible with a slight downward
inclination. For uniform irradiation of a given room the radiators should
be installed decentralised, usually in the corners of the room.
WRONG!
CORRECT:
36
37
SUITABLE MODULATORS
SI 1015 Wideband, single-channel, switchable between
2.3 MHz and 2.8 MHz
SI 1029 Narrow-band, modular system, up to 32 channels (up
to 12 channels per mainframe)
SI 29-5 Narrow-band, 5-channel, choice of 5 out of 32 possible
channels
SUITABLE RECEIVERS
For use in conference and simultaneous interpretation systems
HDI 1029 PLL Narrow-band, 8- or 16-channel, mono, stethoset
receiver
EKI 1029 Narrow-band, 7-, 12-, 16- or 32-channel, mono,
stethoset receiver
additionally RI 250, RI 150, RI 300, RI 500, HDI 302, HDI 380
MZT 14 Mounting bolt
For mounting goosenecks and swivel joints with 3/4 „ threads to table
tops.
GZP 10 Mounting plate
For wall and ceiling mounting.
GZG 1029 Swivel joint
For mounting and aligning the radiator, used in combination with
mounting plate GZP 10, mounting bolt MZT 14 or a stand.
Interchangeable thread 1/4 „ - 3/8 „.
MZT 100 Table stand
In combination with GZG 1029 for simply placing the
radiator on shelves and cupboards.
MZT 1019 Mounting bar
For mounting two radiators. With 3/8 „ internal thread.
SEMS 3136 Stand
For mounting and aligning the radiator. 3/8 „ thread.
MECHANICAL ACCESSORIES
38
39
ELECTRICAL ACCESSORIES
GZL 1019 A1 Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 1 m.
GZL 1019 A5 Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 5 m.
GZL 1019 A10 Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 10 m.
GZV 1019 BNC coupler
For connecting two connection cables GZL 1019 A1, -5, -10.
N.B.: „INFRA-RED If you consider using a transmission system with high power IR radiators
PLANNING BROCHURE“ SZI 1029 the „Infra-red Planning Brochure“ from Sennheiser is available.
FROM SENNHEISER Besides in-depth information on infra-red transmission technology it
contains application examples and lists with combinations and overviews
for infra-red system planning.
Since we are continually trying to improve our products it may happen
that some technical alterations are made on the described products after
these operating instructions have gone to press. We apologise for any
inconvenience.
TECHNICAL SPECIFICATIONS SZI 1029 (SZI 1029-10)
Number of radiator diodes 144 (288)
Approximate radiating power 5 W (10 W)
Wavelength of radiated
infra-red light approx. 880 nm
Carrier frequency range 30 kHz - 6 MHz
IR input 50 mV - 3 V / approx. 5 kΩ
Input/output connections BNC sockets
Switching treshold for
automatic on/off function 50 mV
Operating voltage ...-120 85 - 265 V ± 10 %, 50 - 60 Hz
...-EU 85 - 265 V ± 10 %, 50 - 60 Hz
...-UK 85 - 265 V ± 10 %, 50 - 60 Hz
...-24 24 V min., ideally 25 - 35 V DC
Current consumption ...-120 approx. 610 mA (1A) with 120 V
...-EU approx. 350 mA (700 mA) with 230 V
...-UK approx. 350 mA (700 mA) with 240 V
...-24 approx. 1.6 A (3.2 A) with 24 V DC
Stand-by 60 mA max.
Mains fuse for 120/230/240 V 2 A, anti-surge type
in the IEC mains socket
Fuse for 24 V DC 2 A, anti-surge type
Dimensions in mm 250 x 180 x 80 (250 x 288 x 80)
Weight approx. 2.1 kg (approx. 3 kg)
Supply schedule 1 radiator
1 mains cable (2.5 m)
UL-No. (only for 120 volt
USA version) to be advised
116
Printed in Germany
Publ. 06/03 54500 / A03
Änderungen vorbehalten
Subject to alterations
Modificaciones reservadas
Sous réserve de modification
Con riserva di modifiche
Wijzigingen voorbehouden
Sennheiser electronic GmbH & Co. KG
D-30900 Wedemark
Telefon 05130/600-0
Telefax 05130/600 300
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59

Sennheiser SZI 1029 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI