About Kardia Standard
Water Distribution
Hot water heater with
2x3KW heating elements
Pressure reducing valve
with filter
Bracket for water meter
Flow-through expansion
tank
Manifold with hot and
cold-water outlets
Electrical
Electrical panel with
main circuit breaker
Residual-current circuit
breakers on all circuits
Intended for use with
exterior cabinet for
electrical meter
Allocated space for
low-voltage equipment
Ventilator
Balanced airflow of 120 liters
per second. Up to 90% heat
recovery efficiency
Central Vacuum
17 L capacity
7 AMP motor
Installation kit
Vacuum hose and
complete set of brushes
Cabinet
LED lighting with sensor
Pair of sliding doors
Compatible with IKEA
PAX sliding door system
(150x201)
Kardia Standard User Manual / 2
Table of contents
1. Hot Water Heater
3
2. Central Vacuum
13
3. Ventilator
21
4. Electrical
34
5. Warranty
36
3 /
Hot Water Heater
Kardia Standard User Manual / 4
01
The supplied OSO SAGA
XPRESS hot water heater stores
200L of water. It provides hot
water three times faster than
standard hot water heaters.
The OSO SAGA has been developed with high
grade material selection and intelligent technical
solutions exclusive to OSO. SAGA boasts class
leading insulation capabilities, resulting in
considerable energy savings, whilst maintaining
a higher temperature than other tanks (75°C) for
unbeatable performance and more hot water in a
smaller unit. SAGA XPRESS makes hot water
available 3 times faster than standard hot water
heaters, without increased energy consumption,
thanks to the flip-flop function between the
immersion heaters.
5 /
The hot water heater has two 3kw heaters, each connected to a
temperature sensor. The upper heater will activate when the hot
water heater fills with cold water. Once the upper water
temperature reaches 70°C, the upper heater will cut out, and the
lower heater will start, until the full tank of water is at 70°C. As
hot water gets consumed, the lower heater will start to heat up
the cold water. When a large quantity of hot water is used in a
short period of time, the upper heater starts again as the hot
water heater gets filled with cold water.
Kardia Standard User Manual / 6
User guide
Thermostat Setting
The thermostat on the unit is adjustable from 60-90°C. The
thermostat should not be set lower than 65°C in order to
prevent bacterial growth.
To adjust the temperature
1. Disconnect the power supply.
2. Remove the front covers (4) with a screwdriver.
3. Adjust the temperatures on the thermostat (7)
with a screwdriver.
4. Fit the covers (4) before connecting the power supply.
Changing the temperature setting on the thermostats only
affects the temperature of the water in the tank. Temperature to
the taps is adjusted using the mixer valve.
7 /
Resetting the safety thermostat
The safety thermostat on the tank cuts out when there is a risk
of overheating. This can be reset by removing the cover (4) and
pressing the red ‘RESET’ button (6). If the thermostat cuts out
repeatedly, contact the installer.
WARNING
Constant voltage present in the junction box. Before
any electrical work is carried out, the power supply
must be disconnected and secured against activation
while the work is in progress.
Setting the mixer valve
The temperature of the outgoing hot water from the tank to
the taps in the home can be adjusted using the knob on the
mixer valve.
To adjust the temperature
A) Turn the adjustable knob (1) all the way to ‘+’.
B) Then turn the knob towards ‘-’ to the desired temperature.
Turns
Temperature
0
Approx. 70°C
1/4
Approx. 60°C
1/2
Approx. 50°C
3/4
Approx. 40°C
Kardia Standard User Manual / 8
Maintenance
Maintenance should only be carried out by persons over 18 years
of age, and with technical knowledge.
Annual inspection of safety valve
Open valve for 1 min. by turning the
knob (3) approx. 90 degrees to the
open position.
Visually check that the water is
flowing freely to the drain.
YES = OK. Close the valve by
turning the knob (3) a further 90
degrees to the closed position.
NO = NOT OK. Disconnect power
supply / shut off water supply.
Contact installer.
9 /
Troubleshooting
Problem
Possible cause
of fault
Possible solution
Water
leaks/drips
from the safety
valve, or is
often present
on the floor
near the
cylinder in the
morning
Pressure
reducing valve,
water meter or
blocked non-
return valve on
the water intake.
Water pressure
into the home is
too high.
Fit an AX expansion
vessel which absorbs
expansion during
heating and fit a
pressure reducing
valve for stable water
pressure inside the
home. The pressure
reducing valve is
adjusted according to
the pressure in the
expansion vessel.
Contact authorized
installer.
The safety valve
is worn, or
particles from
impure water
have become
stuck between
the membrane
and the valve
seat.
Try to flush the safety
valve through with
water. Open valve
approx. 1 minute. If the
valve still leaks, it must
be replaced. Contact
authorized installer.
Leak from
heating element.
Verify as follows:
a) turn off the
electrical supply, b)
unscrew the cover,
c) visually check
whether there is a leak
from the heating
element. If so, replace
Kardia Standard User Manual / 10
Problem
Possible cause
of fault
Possible solution
the gasket/heating
element. Contact
authorized Installer.
Knocking in
the pipes when
the hot tap is
closed
Large pressure
increases when a
tap is closed
quickly.
Completely normal. If
this proves
unacceptable, fit an
AX expansion vessel.
Contact authorized
installer.
No hot water
Power supply
interrupted.
Verify that the fuse is
on / and that the earth
breaker has not been
tripped.
Thermostat has
cut out.
Press the ‘RESET
button on the safety
thermostat; see User
guide
Heating element
is defective.
Replace heating
element. Contact
authorized installer.
Leak in hot
water pipe.
Verify as follows:
a) close the mixer
valve
b) wait 2-3 hours
c) feel the mixer valve
to see whether it is
hot. If so, there is a
leak, either in the hot
water pipe or
elsewhere. Contact
authorized installer.
11 /
Problem
Possible cause
of fault
Possible solution
Not enough
hot water
High
consumption in
the home.
Raise the temperature
on the thermostat to
85°C; see ‘USER
GUIDE’. Switch to a
larger OSO water
heater. Contact
authorized installer.
Too low tem-
perature
The mixer valve
is set at a low
temperature.
Raise the temperature
on the mixer valve; see
User guide, page 6.
The thermostat
is set at a low
temperature.
Raise the temperature
on the thermostat to
85°C; see User guide,
page 6.
Change from
cold to hot water
in taps.
Contact authorized
installer.
Fuse/earth
breaker trips
repeatedly
Possible fault in
the heater’s
electrical system.
Verify as follows:
a) switch off the
electrical supply, b)
unscrew the cover,
c) visually check the
junction box for any
problems. If there are,
contact authorized
installer to check. Refit
the cover.
Kardia Standard User Manual / 12
Problem
Possible cause
of fault
Possible solution
There is a delay
before the hot
water reaches
the tap
Long stretch of
pipe from water
heater to tap.
Fit circulation wire or
heating cable to hot
water pipe. Or fit an
auxiliary heater close
to the tap. Contact
authorized installer.
13 /
Central Vacuum
Kardia Standard User Manual / 14
02
Drainvac Central Vacuum
System makes it simple to keep
your house clean.
Kardia have cooperated with Drainvac to deliver the
best central vacuum system, perfect for residential
use.
Model
230v SE1007
Air Watts
700
Pressure
3880 mm H
2
O
Airflow
315 m
3
/h
Sound power level
58 dB
Current
7 A
Liters
17 L
Size
Ø30 x 58 cm
15 /
Maintenance
The filter must be cleaned, and the dust bag periodically
replaced. This will prevent your vacuum from losing power and
will extend its lifespan.
Vacuum bag
Kardia Item number: 333107
Drainvac item number: SAC-31
Vacuum Filter
Kardia item number: 333108
Drainvac Item number:
FILT-DVI-30
The dust bag CANNOT be washed or emptied and must
be replaced. A reduction in power may be caused by
the bag being full. The bag should normally be replaced
every 2 to 4 months.
DO NOT CHANGE THE DUST BAG WHILE THE UNIT IS RUNNING.
Clean the filter whenever the dust bag is changed. The filter can
easily be cleaned in the washing machine but drying in the
dryer is not recommended. The filter must be COMPLETELY
DRY before re-use.
To avoid delay in using the vacuum unit while waiting for the
filter to dry, it is recommended that an extra filter be purchased
on www.kardia.no.
Kardia Standard User Manual / 16
Using the vacuum unit, without the filter or the dust bag,
will void the warranty. The unit should be used with a dust
bag because this will stabilize the efficiency of the unit and
reduce by 5 to 6 times the maintenance of your unit. This is
due to its large filtration surface. Order replacement bags
and filters on www.kardia.no.
Motor brushes
Beside the occasional external clean, it is recommended that
the motor brushes are inspected after 500 hours of use to
check for wear. Replace as necessary. This inspection should be
carried out on average once every 3 to 5 years. Contact service
for information about the correct time interval for this
maintenance procedure.
17 /
Troubleshooting
Problem
Solution
Unit won’t
start up
1. Check if the LED is illuminated.
2. Check the circuit breaker in your electrical
panel.
3. Check the unit’s circuit fuse/breaker.
4. Check the 24-volt circuit, as follows:
Try to establish electrical contact in a wall inlet
between the two metal contacts with a metal
object (e.g. a coin).
If the unit starts, the suction hose is
defective.
If the unit doesn’t start, check to see if the
24-volt wires are properly connected to
the unit. Try to establish an electrical
contact between the two terminals of the
24-volt circuit on the unit with a metal
object (e.g. a screwdriver).
If the unit starts, a 24-volt wire is either cut
or disconnected from one of the wall
inlets.
If the unit won’t start up after these steps,
the printed circuit is defective.
Unit won’t
shut
down
Check the 24-volt circuit as follows:
Disconnect one of the two wires on the unit’s 24-
volt circuit.
If the unit shuts down, the problem could
be that two 24-volt wires are touching
each other somewhere or that the wall
inlet is defective.
If the unit doesn’t shut down, the printed
circuit is defective. Unplug the power cord.
Kardia Standard User Manual / 18
Basic safety precautions should always be followed when
operating an appliance containing electronics,
Read all manuals before operating the unit.
To reduce risk of fire, electrical shocks or injuries:
Only operate this vacuum unit in the manner described in
this manual. (Use of attachments not approved by the
manufacturer may cause fire, electric shock, injury or
damage to system components).
Do not allow the vacuum unit to be used by children.
Close supervision is necessary when this vacuum is operated
around children.
Do not leave the unit running without supervision.
Disconnect the unit when not in use and prior to
maintenance.
The vacuum unit is designed for dry suction only. Do not use
on wet or moist surfaces. Avoid suction of any flammable
liquids or combustible materials (gasoline, fuel, diesel), hot
debris, flammable materials (cigarettes, ashes, matches),
waste solvents (paint or other), or explosive materials that
would cause harm to the vacuum unit.
Refrain from vacuuming drywall dust or baking flour as these
may damage the vacuum unit.
Avoid sucking up hard or sharp objects in order to prevent
damage or blockage to the hose and the plastic pipes.
Refrain from placing objects into the hose openings. Do not
operate the unit if a hose is blocked. Keep free of dust, lint,
hair and anything that may reduce air flow/suction. A lack of
air flow will cause the motor to overheat. In the case of the
supply cord being damaged, this must be replaced by the
manufacturer, its service agent or similar qualified persons in
order to avoid danger.
19 /
The appliance may be operated by children aged 8 years and
above and also persons with reduced physical, sensory or
mental capabilities or lack of technical knowledge, provided
they are supervised or have been given instructions concerning
the responsible use of the appliance and are aware of the
dangers present. Children must not play with the appliance.
Cleaning and maintenance of the unit shall not be carried out
by children unless supervised.
The vacuum unit produces a suction. Ensure that hair, face,
fingers, all body parts and loose clothing are kept away from
any openings.
Never operate without the dust bag and/or the filter being in
place.
In the case of the power cord being damaged, this must be
replaced with a dedicated cord available only from an
authorized local dealer/distributor.
Never operate the vacuum unit with a damaged cord or
plug, Should the system not be operating properly, or if it has
been dropped or damaged, it must be returned to an
authorized dealer/distributor for repair.
Never handle the plug, the cord or the power unit with moist
hands.
Never disconnect the plug by pulling on the cord. To
disconnect from the outlet, grip the plug, not the cord.
Turn off all controls before unplugging.
Damaged hoses with electrical connections must
not be used.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Kardia Standard V.102 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI