Halo SMD4S6940WH User guide

Type
User guide
SMD - Surface LED Downlight Series
Dimming Guide and Step-down Transformer Application Note
The SMD LED Series provides continuous dimming with reverse or forward phase cut dimmers; as low as 5% depending upon
dimmer and low-end trim of the dimmer.
120V AC dimmed power
to Halo Surface
LED Downlights
120V AC Power
(2 wire + Gnd typical)
120V AC dimmed power
to Halo Surface
LED Downlights
120V AC Power
(2 wire + Gnd typical)
HALO
Figure 1
Recessed Housing
Installation
Figure 2
Direct Mount
Installation
SMD4 SMD4-DM SMD6 SMD6-DM
SMD4R6927WH
SMD4R6930WH
SMD4R6935WH
SMD4R6940WH
SMD4R6950WH
SMD4S6927WH
SMD4RS930WH
SMD4RS935WH
SMD4RS940WH
SMD4RS950WH
SMD4R6927WHDM
SMD4R6930WHDM
SMD4R6935WHDM
SMD4R6940WHDM
SMD4R6950WHDM
SMD4S6927WHDM
SMD4RS930WHDM
SMD4RS935WHDM
SMD4RS940WHDM
SMD4RS950WHDM
SMD6R6927WH
SMD6R6930WH
SMD6R6935WH
SMD6R6940WH
SMD6R6950WH
SMD6S6927WH
SMD6RS930WH
SMD6RS935WH
SMD6RS940WH
SMD6RS950WH
SMD4R6927WHDM
SMD4R6930WHDM
SMD4R6935WHDM
SMD4R6940WHDM
SMD4R6950WHDM
SMD4S6927WHDM
SMD4RS930WHDM
SMD4RS935WHDM
SMD4RS940WHDM
SMD4RS950WHDM
*Note: The Rapid Start feature is used to ensure the right amount of power boost during start-up. When a dimmer with Rapid Start is turned on from a low dimmer setting,
the LED lighting may exhibit a momentary flash. Select dimmer models offer an adjustment of the Rapid Start feature. The user may wish to adjust this setting to reduce the
boost and resulting momentary flash. If this capability is desired, the user should select dimmer models designated as “fully adjustable” or “selectable ON or OFF”.
Eaton's AL Series dimmers offer versatile options
to set the mood and reduce energy consumption.
Visit www.cooperwiringdevices.com/ALSeries for
more information.
Dimmer Features
Decorator dimmer
DAL06P/WBSD-DEC
Slide dimmer
SAL06P/WBSD-SLD
Toggle dimmer
TAL06P/WBSD-TOG
Rapid Start feature* Fully adjustable Fixed ON Fully adjustable
Adjustable high-end trim
Adjustable low-end trim
Wiring configurations Single-pole or 3-way Single-pole or 3-way Single-pole or 3-way
Color change kits
Phase Control 120V Dimming
PA518082EN
February 9, 2017
Dimmer
Make
Dimmer
Series
Dimmer
Model #
Types Of Dimmer Minimum
Luminaires
(per circuit)
Maximum
Recommended
Luminaires
(per circuit)
Min Dimming
percentage
(%)
Max Dimming
percentage
(%)
Low End
Start-up time
EATON Decorator DAL06P
Triac (INC/HAL/MLV/ELV/CFL/
LED)
1 23 3% 98% <1s
EATON Toggle TAL06P
Triac(INC/HAL/MLV/ELV/CFL/
LED)
1 23 4% 98% <2s
EATON Slide SAL06P
Triac(INC/HAL/MLV/ELV/CFL/
LED)
1 23 4% 98% <1s
EATON Slide SLC03P Triac (INC/HAL/CFL/LED) 1 23 4% 98% <1s
EATON Toggle DLC03P Triac (INC/HAL/CFL/LED) 1 23 4% 98% <1s
EATON iLumin SC277-06-UN Control Panel( Leading Edge) 1 38 3% 97% <3s
Lutron Diva DVCL-153P 1 11 4% 97% <1s
Lutron Toggler TGCL-153P 1 11 4% 97% <1s
Lutron Maestro MACL-153-M 1 11 4% 97% <1s
Lutron Skylark SCL-153P-WH 1 11 4% 97% <1s
Lutron LC128 LP-RPM-4U-120 1 150 4% 98% <1s
Lutron LC128 LP-RPM-4A-120 1 94 1% 97% <3s
Leviton SureSlide 6674 1 11 6% 97% <1s
Leviton Illumatech IPL06 1 11 4% 97% <2s
Legrand
Pass&Seymour
Harmony
H703PTUW 1 35 4% 99% <1s
Dimmer Rating - Load Type
INC = Incandescent
HAL = Halogen
MLV = Magnetic Low Voltage
ELV = Electric Low Voltage
CFL = Compact Fluorescent
LED Rated Dimmers
2
Eaton SLD Dimming Guide - PA518058EN
Dimmer
Make
Dimmer
Series
Dimmer
Model #
Types Of Dimmer Minimum
Luminaires
(per circuit)
Maximum
Recommended
Luminaires
(per circuit)
Min Dimming
percentage
(%)
Max Dimming
percentage
(%)
Low End
Start-up time
EATON Toggle TI061 Triac (INC/HAL ) 1 47 3% 95% <1s
EATON Aspire 9530AW Triac(INC) 1 47 3% 100% <3s
EATON Rotary RI061 Triac(INC/HAL) 1 47 15% 98% <1s
EATON Slide SF8AP 1 76 20% 98% <1s
EATON Decorator DE06P ELV 1 47 3% 96% <3s
Lutron Toggler TG-600P Triac (INC ) 1 47 1% 97% <7s
Lutron Diva DV-600P Triac (INC ) 1 47 4% 97% <1s
Lutron Lumea LG600P Triac (INC/HAL ) 1 47 6% 97% <1s
Lutron Skylark S-600P Triac (INC/HAL ) 1 47 3% 97% <1s
Lutron Skylark Contour CT103P Triac (INC/HAL/MLV) 1 79 3% 97% <1s
Lutron Diva DV603P Triac (INC/HAL ) 1 47 4% 97% <1s
Lutron Nova T NTFTU-5A Triac (Fluorescent ) 1 47 16% 97% <1s
Lutron Maestro MAELV600 ELV 1 47 4% 97% <1s
Lutron Faedra FAELV500 ELV 1 39 4% 97% <1s
Lutron Diva DVELV303P ELV 1 23 1% 97% <2s
Lutron Skylark SELV300P ELV 1 23 1% 97% <2s
Leviton Decora 6673 Triac (CFL/INC) 1 47 30% 97% <1s
Leviton SureSlide 6631-2 Triac (INC ) 1 47 4% 97% <1s
Leviton IPI06 1 47 4% 97% <3s
Leviton Vizia VP106 Triac (INC ) 1 47 4% 97% <1s
Leviton Decora 6161 Triac (INC ) 1 39 4% 97% <1s
Leviton Sure Slide 6633-P 1 47 4% 97% <1s
Leviton
Plug In Lamp
Dimmer
TBI03 Triac 1 23 3% 99% NA
1
Leviton Vizia VPE06 ELV 1 47 4% 97% <1s
Leviton Illumatech IPE04 ELV 1 23 6% 97% <1s
Leviton Vizia VZE04 ELV 1 31 4% 97% <1s
Lutron Ariadni AY-600P 1 47 1% 97% <6s
Lutron Contour CT-103P 1 79 3% 97% <1s
Lutron Contour CT-600P 1 47 3% 97% <1s
Lutron Rotary D-600P 1 47 20% 97% <1s
Lutron Diva DV-600P 1 47 3% 97% <1s
Lutron Glyder GL-600P 1 47 3% 97% <1s
Lutron Lumia LG-600PH 1 47 3% 97% <1s
Lutron Maestro MA600 1 47 3% 97% <1s
Lutron Nova N-600 1 47 4% 97% <1s
Lutron Skylark S-600P 1 47 3% 97% <1s
Lutron Centurion C-600P 1 47 0% 98% NA
1
Lutron Ariadni AYLV-600P 1 35 1% 3% <7s
Lutron Glyder GLV-600 1 35 3% 97% <1s
Lutron Diva DVLV-600P 1 35 0% 97% NA
1
Lutron Lumina LG-103P 1 79 3% 97% <1s
Lutron Skylark SLV-600P 1 35 3% 97% <1s
Lutron Vierti VT-600 1 47 4% 97 NA
1
Lutron Nova NTLV-600 1 35 3% 97% <2s
Lutron Nova NT-600 1 47 0% 97% NA
1
1. Will not illuminate at low end start up.
Testing conducted by Eaton's lighting division is not a substitute for and does not imply certification by an independent laboratory or any other standards certification.Refer
to manufacturer specifications for more detailed information on product certifications and standards. Refer to this dimming guide notes section. Consult the dimmer manu-
facturer prior to installation to ensure compatibility.
Incandescent and Electronic Low Voltage Rated Dimmers - For Reference Only
Dimmer Rating - Load Type
INC = Incandescent
HAL = Halogen
MLV = Magnetic Low Voltage
ELV = Electric Low Voltage
CFL = Compact Fluorescent
3
Eaton SLD Dimming Guide - PA518058EN
Dimmer Notes:
1. Start time is measured at the lowest dimmer setting.
2. Some LED rated dimmers have a "rapid start" design used to provide a momentary power boost for LED and CFL
lamps during start-up. When a LED luminaire is on a dimmer with "rapid start" the boost may cause a momentary
flash of the LED lighting. This "flash" is generated by the dimmer, and may be more noticeable when the dimmer
is at a low setting. A solution is available in the following EATON dimmers which provide adjustment capability of
the "rapid start": Decorator (DAL06P), Smart (AAL06), and Toggle (TAL06P). Refer to product specifications online at
www.cooperwiringdevices.com for more details.
Dimming Guide Disclaimer:
1. Leviton
®
is a registered trademark of Leviton Manufacturing Co. Inc.; Lutron
®
is a registered trademark of Lutron
Electronics Co. Inc.; Lightolier
®
is a registered trademark of Philips Lighting; Hubbell
®
is a registered trademark of
Hubbell Incorporated; Legrand
®
and Pass & Seymour
®
are registered trademarks of Legrand
®
. These companies and
their tradenames, trademarks or brands, where noted, are associated with their respective company and are not
associated with EATON.
2. Testing conducted by EATON is not a substitute for and does not imply certification by an independent laboratory or
any other standards certification. Refer to the manufacturer specifications for more detailed information on product
certifications and standards.
3. This is a representative list of typical dimmers as tested by EATON for performance with the designated LED
luminaires only. Test data contained in this literature is based upon dimmers obtained in the marketplace.
Information about these other manufacturers products is obtained from packaging and published information
made available by the manufacturer and is deemed to be reliable, but has not been verified. 
Dimmer performance and perceived limitations of the dimmers are based onfactors outside of EATON's control.
The specifications of these dimming controls and their conditions of use may change without notice to EATON or
any other user.
EATON makes no specific recommendation on product selection and there are no warranties of performance or
compatibility implied. 
Installer must ensure proper local and national electrical codes are followed; and that the dimmer application and
condition of use is per dimmer manufacturer instructions and guidelines.
4
Eaton SLD Dimming Guide - PA518058EN
Transformer Load - H277 (300VA)
1. H277 Transformer at full loading consumes a maximum of 16W of power.
2. When a dimmer or switch is on the secondary (120V) side of the transformer,
power is consumed by the transformer when the dimmer or switch is in OFF”
mode at 6.5W and in ON” mode at 16W maximum under full loading.
3. When a switch is on the primary (277V) side ahead of the transformer, power is
consumed only in ON” mode to a maximum of 16W under full loading. (Use of a
dimmer ahead of the transformer is not recommended)
Transformer Load - H347 (75VA)
1. H347 Transformer at full loading consumes a maximum of 15W of power.
2. When a dimmer or switch is on the secondary (120V) side of the transformer,
power is consumed by the transformer when the dimmer or switch is in OFF”
mode at 2.5W and in ON” mode at 15W maximum under full loading.
3. When a switch is on the primary (347V) side ahead of the transformer, power is
consumed only in ON” mode to a maximum of 15W under full loading.
(Use of a dimmer ahead of the transformer is not recommended)
Transformer Load - H347200 (200VA)
1. H347200 Transformer at full loading on 120V side consumes a maximum of 28W
of power.
2. When a dimmer or switch is on the secondary (120V) side of the transformer,
power is consumed by the transformer when the dimmer or switch is in OFF”
mode at 9.2W and in ON” mode at 28W maximum under full loading.
3. When a switch is on the primary (347V) side ahead of the transformer, power is
consumed only in ON” mode to a maximum of 28W under full loading.
When a switch is on the primary (277V) side ahead of the transformer, power is
consumed only in ON” mode to a maximum of 12W under full loading.
(Use of a dimmer ahead of the transformer is not recommended)
Step Down Transformers
H277 = Steps 277 line voltage down to 120 volts. Attaches to knockout on first fixture’s
junction box in a circuit and is 300VA rated. H277 is a UL recognized Component listed
under the luminaire UL/cUL listing for Halo Non-IC housings.
H347 and H347200 = Steps 347 line voltage down to 120 volts. Attaches to knockout
on first fixture’s junction box in a circuit. H347 is 75VA and H347200 is 200VA rated.
H347 is a CSA/UL Listed Component for use under the luminaire UL/cUL listing with
Halo Non-IC housings.
H347
347V Step Down Transformer,
75VA
2-7/8
2-1/2”
[63mm]
2-3/4”
[70mm]
H347
H347200
347V Step Down Transformer,
200VA
2-7/8
2-3/16”
[56mm]
4-3/4”
[121mm]
H347200
H277
277V Step Down Transformer,
300VA
2-7/8
2-3/16”
[56mm]
4-3/16”
[106mm]
H277
Application Note
H277, H347 and H347200 step-down transformers are qualified to drive multiple Halo LED on a single circuit in Non-IC
construction. Installation of these transformers with individual LED fixtures on circuits with multiple LED loads is not
recommended. This is not recommended due to resulting multiple inductive currents pulled by each transformer; in
this situation the majority of the power would then be reactive (VARS) and not real (WATTS). If H277, H347 or H347200
transformers should be used individually on each LED fixture in a single circuit, then that circuit should be sized for
lowered power factor as well as increased apparent power on the circuit. H277, H347 and H347200 are UL/cUL listed for
use with Halo recessed housings: H750T, H750TCP, H7T, H7TNB, H7RT.
SMD - Surface LED Downlight Series
SMD Maximum Units on Step Down Transformer
Powered Circuits
SMD4, SMD6 - 80 CRI
SMD4 - 90 CRI SMD6 - 90 CRI
VA Rating Max # of Fixtures Max # of Fixtures
H277
300 18 16
H347
75 4 4
H347200
200 12 10
5
Eaton SLD Dimming Guide - PA518058EN
Ground
277V
120V
Hot
Hot
Transformer
Switch*
Neutral
Neutral
LED LED LED
Transformer with Switch on 277V Primary
347V Switch*
347V
120V
Hot
Hot
Transformer
Neutral
Neutral
LED LED LED
Ground
Transformer with Switch on 347V Primary
277V
(347V)
120V
Hot
Transformer
Hot
Neutral
Neutral
LED LED LED
Ground
Transformer with Dimmer/Switch on 120V Secondary
Dimmer Neutral Connection typical with some Dimmers
120V Dimmer or Switch
*Use of a dimmer ahead of the transformer is not recommended
*Use of a dimmer ahead of the transformer is not recommended
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Halo SMD4S6940WH User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI