  • Hello! I am an AI chatbot trained to assist you with the Mircom LT-869 QIF-2000 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
QIF-2000
Emergency Voice Alarm System Interface Board
LT-869 Rev. 3
January 2010
Installation Instructions
The QIF-2000 Interface module comes already mounted onto a CH-559 Plate. The CH-559 mounts onto the QBC-
5000B battery charger cover located above the amplifiers in the audio cabinet of the QX-5000 Audio system. The
QBC-5000B must be removed and the QIF-2000, and its plate is mounted onto the QBC-5000B with four #4 screws
behind the QBC-5000B cover. The whole assembly is then mounted back into the audio cabinet over the battery
charger.
Figure 1: Mounting QIF-2000 Interface Module
The QIF-2000 Interface module is used for complex mapping. Inputs 1 through 16 may be programmed via fire
alarm relays to activate different zones with an alert or evacuation tone. The mapping is configured at our factory.
Figure 2: QIF-2000 Interface Wiring Diagram (if using a QIF-1000 see Figure 3)
TOP VIEW
FRONT VIEW of CH-559 PLATE
BACK OF
PLATE
FRONT OF
PLATE
12 VDC BATTERY
12 VDC BATTERY
INLINE FUSE
- BATTERY +
Orange-Yellow-Orange
(MUST BE IN CORRECT ORDER)
XFORMER
SCREW
TERMS
Black
120 VAC INPUT
LIVE / NEUTRAL / GROUND
LUG
IN OUT
SCREW
TERMS
Red
QBC-5000B
BATTERY
CHARGER
CONNECTORS FOR MULTIPLE
QMB-5000B MOTHERBOARDS
SLOT #1
CONNECTOR FOR
QIF-5000B INTERFACE
MODULE
SLOTS #2 - #8
CONNECTORS FOR
QAA- STYLE AMPLIFIERS
CONNECTOR FOR QBC-5000B
BATTERY CHARGER
QPS-5000
POWER SUPPLY
QIF-2000
J7
J8
J6
J5
V+OUT
V+IN
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
QIF-2000
L R
JP1
5-WIRE HARNESS TO
QIF-5000 J11
MD-702 CABLE
NORMALLY OPEN CONTACTS
FROM FIRE ALARM
CONFIGURABLE RELAYS ON
THE FA-1000 OR FX-2000
(MUST BE CLOSE CONDUIT)
JP2
J8 NOT USED UNLESS MULTIPLE QIF-2000 INTERFACE
MODULES ARE USED AND THEN THE MD-758 CABLE IS
CONNECTED FROM HERE TO J7 OF THE NEXT QIF-2000
PUT JUMPER JP1 ON
THE LEFT TWO PINS
TO QIF-5000B
J2-8
TO MASTER PAGING
QMP-5xxx, V+
F1 FUSE 0.5A
F2 0.65A PTC
F1 F2
6 PIN MOLEX
INPUTS
MOUNTING HOLES (4)
EN-OUT
CC -
CC +
RM-1008A
CLOSE NIPPLE CONNECTED BETWEEN QIF-2000 18AWG
AND THE FIRE ALARM PANEL
Figure 3: Wiring Diagram When Using A QIF-1000 And QIF-2000 With The QX-5000
Note: If the fire alarm panel is not nearby (beyond 24 ft. from the QX-5000), the fire alarm panel must be
addressable, FX-2000 and the use of an addressable relay module CR-6 must be used for the QIF-2000
Interface module.
V+
V+
AOUT+
AOUT-
AOUTS
AIN+
AIN-
AINS
AIN+
AIN-
AINS
AUDIO1
AUDIO2
SHIELD
AUDIO1
AUDIO2
SHIELD
RS-485 +
RS-485 -
SHIELD
RS-485 +
RS-485 -
SHIELD
J1
J2
J11
J11
J1-1
J1-1
J1-2
J1-2
J1-5
J1-5
J1-3
J1-3
J1-4
J1-4
J2-8
J2-8
5 wire harness
QIF-1000 V+
QIF-5000B J2-8
Mic -
Mic -
Mic +
Mic +
Shield
Shield
J1-1
J1-1
J1-2
J1-2
J1-3
J1-3
J1-4
J1-4
J1-5
J1-5
J1-5
J1-5
J2-1
J2-1
J2-2
J2-2
PTT+
PTT+
PTT-
PTT-
MD-702
MD-702
J7
J8
T
U
O-
N
E
-
C
C
+C
C
MD-702
MD-702
SEL0
Removed
JP2
OUT
OUT
+V
IN
IN+V
RM-1008A Common
From QMP-5xxx
From QMP-5xxx
From QMP-5xxx V+
#1
#1
QIF-5000B #1
QIF-1000
QIF-2000
QIF-2000 V+ OUT
AUDIO FROM LOCAL QMP
AUDIO FROM OTHER QMP
QIF-1000 #1
ID=1
DIP SW: ALL ON
(MASTER)
JW1 Installed
JW2, 3 removed
MIC OUT +
MIC OUT -
SHIELD
NOTE: When using multiple
QIF-2000s refer to Figure 4
and note that JP2 is not removed
from additional QIF-2000s
Figure 4: Multiple QIF-2000 Wiring Diagram
V
+
O
U
T
V
+
I
N
TO V+ OF THE QMP-TO V+ OF THE QMP-
5100B/5101B OR 5100B/5101B OR
QIF-1000 if used.QIF-1000 if used.
B
B
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
V
+
O
U
T
V
+
I
N
NOTE: MULTIPLE QIF-2000s ARE WIRED AS SHOWN HERE WITH A MAXIMUM OF EIGHT
QIF-2000s PER QX-5000 SYSTEM. FOR SUPERVISION PURPOSES THE 16th
INPUT OF THE LAST UNIT (UNIT 8) MUST BE PERMANENTLY CONNECTED TO VCC.
IF THE QIF-2000 UNIT 1 IS CONNECTED TO A QIF-1000, THEN REMOVE JUMPER JP2
ON THE QIF-2000 UNIT 1 (REFER TO FIGURE 2 FOR THE LOCATION OF JP2).
DO NOT REMOVE JP2 ON UNITS 2 TO 8.
Notes
Canada
25 Interchange Way
Vaughan, ON L4K 5W3
Tel: 905-660-4655 Fax: 905-660-4113
© Mircom 2010
Printed in Canada
Subject to change without prior notice
www.mircom.com
U.S.A.
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Tel: 1-888-660-4655 Fax: 1-888-660-4113
/