SERVICE MANUAL
June 7, 2004
MODEL
HOSHIZAKI
MODULAR FLAKER
F-801MAH/-C
F-801MWH/-C
73113
June 15, 2005
ISSUED:
NO:
REVISED:
2
IMPORTANT
Only qualified service technicians should attempt to service or maintain this
icemaker. No service or maintenance should be undertaken until the technician
has thoroughly read this Service Manual.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the
service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call or write to the HOSHIZAKI Technical Support Department for
assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: 1-800-843-1056
(770) 487-3360
Web Site: www.hoshizakiamerica.com
Note: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
3
CONTENTS
I. Specification ...................................................................................................................... 5
1. Icemaker ....................................................................................................................... 5
F-801MAH.................................................................................................................. 5
F-801MWH ................................................................................................................. 6
F-801MAH-C .............................................................................................................. 7
F-801MWH-C ............................................................................................................. 8
II. General Information .......................................................................................................... 9
1. Construction .................................................................................................................9
F-801MAH/-C ............................................................................................................. 9
F-801MWH/-C .......................................................................................................... 10
2. Control Box Layout ..................................................................................................... 11
F-801MAH/-C ........................................................................................................... 11
F-801MWH/-C .......................................................................................................... 12
III. Technical Information ..................................................................................................... 13
1. Water Circuit and Refrigeration Circuit........................................................................ 13
F-801MAH/-C ........................................................................................................... 13
F-801MWH/-C .......................................................................................................... 14
2. Wiring Diagrams ......................................................................................................... 15
F-801MAH/-C, F-801MWH/-C .................................................................................. 15
3. Sequence of Electrical Circuit .................................................................................... 16
4. Timing Chart ............................................................................................................... 26
5. Performance Data ....................................................................................................... 29
F-801MAH................................................................................................................ 29
F-801MWH ............................................................................................................... 30
F-801MAH-C ............................................................................................................ 31
F-801MWH-C ........................................................................................................... 32
IV. Adjustment of Components ............................................................................................ 33
1. Adjustment of Water Regulating Valve (water-cooled model only) .............................. 33
2. Adjustment of Flake Size ............................................................................................ 34
V. Service Diagnosis........................................................................................................... 35
1. No Ice Production ....................................................................................................... 35
2. Low Ice Production ..................................................................................................... 37
3. Other ........................................................................................................................... 38
VI. Removal and Replacement of Components .................................................................. 39
1. Service for Refrigerant Lines ...................................................................................... 39
[a] Refrigerant Recovery........................................................................................... 39
[b] Evacuation and Recharge [R-404A] .................................................................... 39
2. Brazing ....................................................................................................................... 40
3. Removal and Replacement of Compressor ................................................................ 41
4. Removal and Replacement of Drier ........................................................................... 42
Please review this manual. It should be read carefully before the icemaker is serviced or
maintenance operations are performed. Only qualified service technicians should service
and maintain the icemaker. This manual should be made available to the technician prior
to service or maintenance.
4
5. Removal and Replacement of Expansion Valve ......................................................... 43
6. Removal and Replacement of Water Regulating Valve (water-cooled model only) .... 44
7. Removal and Replacement of Evaporator Assembly ................................................. 45
8. Removal and Replacement of Fan Motor ................................................................... 49
9. Removal and Replacement of Control Water Valve .................................................... 49
10. Removal and Replacement of Flush Water Valve ..................................................... 50
VII. Cleaning and Maintenance .......................................................................................... 51
1. Preparing the Icemaker for Long Storage ................................................................... 51
2. Cleaning and Sanitizing Instructions .......................................................................... 52
[a] Cleaning Solution ................................................................................................ 52
[b] Cleaning Procedure ............................................................................................ 53
[c] Sanitizing Solution............................................................................................... 54
[d] Sanitizing Procedure - Initial................................................................................ 54
[e] Sanitizing Procedure - Final ................................................................................ 55
3. Maintenance ............................................................................................................... 57
5
I. Specification
1. Icemaker
F-801MAH
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 9.4 RLA 51 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR 115 V 0.85 FLA 1/15 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient
PER 24 HR. Temp.(°F)
lbs./day ( kg/day ) 70 * 823 (373) 786 (357) 748 (339)
Reference without *marks 80 711 (323) 677 (307) 644 (292)
90 613 (278) * 599 (272) 555 (252)
100 528 (239) 502 (228) * 471 (214)
SHAPE OF ICE Flake
ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1131 (4.5) 1089 (3.2)
POTABLE WATER 72 (12) 99 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FP
T
- DRAIN Outlet 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43-C2E-CAA
CONDENSER Air-cooled, Fin and Tube Type
EVAPORATOR Copper Tube on Cylinde
r
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, (800 g)
DESIGN PRESSURE High 427 PSIG, Low 230 PSIG
PC BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Spare Fuse
- REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
1lb 12oz
50
WATER TEMP. (°F)
70 90
6
F-801MWH
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 8.5 RLA 51 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient
PER 24 HR. Temp.(°F)
lbs./day ( kg/day ) 70 * 720 (327) 693 (315) 677 (307)
Reference without *marks 80 661 (300) 646 (293) 630 (286)
90 616 (279) * 605 (274) 587 (266)
100 573 (260) 560 (254) * 520 (236)
SHAPE OF ICE Flake
ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/5F
ELECTRIC W (kWH/100 lbs.) 1078 (4.3) 1076 (3.6)
POTABLE WATER 72 (12) 86 (12)
WATER-COOLED CONDENSER 360 (60) 219 (31)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT Cond. Inlet 1/2" FPT
- DRAIN Outlet 3/4" FP
T
Cond. Outlet 3/8" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43-C2E-CAA
CONDENSER Water-cooled, tube in tube type
EVAPORATOR Copper Tube on Cylinde
r
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, (470 g)
DESIGN PRESSURE High 427 PSIG, Low 230 PSIG
PC BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protecto
r
GEAR MOTOR PROTECTION Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW W ATE R PROTECTION Float Switc h and Time
r
ACCESSORIES - SUPPLIED Spare Fuse
- REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
1lb 1oz
50
WATER TEMP. (°F)
70 90
7
F-801MAH-C
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 9.4 RLA 51 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR 115 V 0.85 FLA 1/15 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient
PER 24 HR. Temp.(°F)
lbs./day ( kg/day ) 70 * 752 (341) 728 (330) 688 (312)
Reference without *marks 80 650 (295) 614 (279) 580 (263)
90 548 (249) * 552 (250) 490 (222)
100 463 (210) 437 (198) * 405 (184)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/5F
ELECTRIC W (kWH/100 lbs.) 1169 (5.1) 1110 (3.5)
POTABLE WATER 66 (12) 90 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FP
T
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43-C2E-CAA
CONDENSER Air-cooled, Fin and Tube Type
EVAPORATOR Copper Tube on Cylinde
r
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, (800 g)
DESIGN PRESSURE High 427 PSIG, Low 230 PSIG
PC BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protecto
r
GEAR MOTOR PROTECTION Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW W ATE R PROTECTION Float Switc h and Time
r
ACCESSORIES - SUPPLIED Spare Fuse
- REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
50
WATER TEMP. (°F)
70 90
1lb 12oz
8
F-801MWH-C
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 8.5 RLA 51 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient
PER 24 HR. Temp.(°F)
lbs./day ( kg/day ) 70 * 645 (293) 620 (281) 608 (276)
Reference without *marks 80 596 (270) 585 (265) 574 (260)
90 563 (255) * 550 (249) 541 (246)
100 531 (241) 521 (236) * 485 (220)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1075 (4.7) 1083 (4.1)
POTABLE WATER 66 (12) 77 (12)
WATER-COOLED CONDENSER 302 (55) 199 (31)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FP
T
Cond. Inlet 1/2" FP
T
- DRAIN Outlet 3/4" FPT Cond. Outlet 3/8" FP
T
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43-C2E-CAA
CONDENSER Water-cooled, tube in tube type
EVAPORATOR Copper Tube on Cylinde
r
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, (470 g)
DESIGN PRESSURE High 427 PSIG, Low 230 PSIG
PC BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Spare Fuse
- REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
1lb 1oz
50
WATER TEMP. (°F)
70 90
9
II. General Information
1. Construction
F-801MAH/-C
Water Supply
Inlet
Junction Box
Condenser
Fan Motor
Compressor
Drier
Control Water Valve
Bin Control
Ice Chute
Evaporator
Expansion
Valve
Flush Water
Valve
Control Box
Gear Motor
10
F-801MWH/-C
Water Supply
Inlet
Junction Box
Water
Regulator
Compressor
Drier
Control Water Valve
Bin Control
Ice Chute
Evaporator
Expansion
Valve
Flush Water
Valve
Control Box
Gear Motor
11
2. Control Box Layout
F-801MAH/-C
Note: The above component names are identical with the wiring label, but not with
the parts list.
PRESSURE
SWITCH
CONNECTOR
START
CAPACITOR
RUN
CAPACITOR
WATER CONTROL
RELAY
FLUSH
TIMER
TRANSFORMER
GEAR
MOTOR
RELAY
GEAR
MOTOR
CAP.
FLUSH
ICE
FAN
MOTOR
CAP
GEAR MOTOR
PROTECT RELAY
STARTER
CONTROL
TIMER
FUSE
(GEAR MOTOR
)
FUSE
POWER
SWITCH
FLUSH
SWITCH
CIRCUIT PROTECT
RELAY
12
F-801MWH/-C
PRESSURE
SWITCH
CONNECTOR
START
CAPACITOR
RUN
CAPACITOR
WATER CONTROL
RELAY
TRANSFORMER
GEAR
MOTOR
RELAY
FLUSH
ICE
GEAR MOTOR
PROTECT RELAY
STARTER
CONTROL
TIMER
FLUSH
SWITCH
POWER
SWITCH
FUSE
FUSE
(GEAR MOTOR)
FLUSH
TIMER
CIRCUIT PROTECT
RELAY
GEAR
MOTOR
CAP.
13
III. Technical Information
1. Water Circuit and Refrigeration Circuit
F-801MAH/-C
14
F-801MWH/-C
15
2. Wiring Diagrams
F-801MAH/-C, F-801MWH/-C
16
3. Sequence of Electrical Circuit
[a] When power switch is moved to “ON” position and flush switch to “ICE” position,
water starts to be supplied to reservoir.
17
[b] When reservoir has been filled, gear motor starts immediately.
18
[c] Compressor starts about 60 sec. after gear motor starts.
19
[d] Bin control operates, and about 6 sec. later, compressor and gear motor stop
simultaneously.
20
[e] Low water (except water-cooled model).
/