LG LMU36CHV Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

The LG LMU36CHV multi air conditioner is a powerful and versatile unit that can be used for both cooling and heating purposes. With a cooling capacity of 36,000 Btu/h and a heating capacity of 32,000 Btu/h, it is suitable for use in large rooms or even small apartments. It also features a number of convenient functions, such as a self-diagnosis system, a 3-minute restart delay, and a night quiet mode. Additionally, the LG LMU36CHV is compatible with a variety of optional accessories, such as a central controller and a simple controller, which can be used to further customize its operation.

The LG LMU36CHV multi air conditioner is a powerful and versatile unit that can be used for both cooling and heating purposes. With a cooling capacity of 36,000 Btu/h and a heating capacity of 32,000 Btu/h, it is suitable for use in large rooms or even small apartments. It also features a number of convenient functions, such as a self-diagnosis system, a 3-minute restart delay, and a night quiet mode. Additionally, the LG LMU36CHV is compatible with a variety of optional accessories, such as a central controller and a simple controller, which can be used to further customize its operation.

Multi Air Conditioner
SVC MANUAL(Exploded View)
MODEL : A4UW36GFA0 [LMU36CHV]
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
- 2 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7°C(80°F) DB / 19.4°C(67°F) WB
Outdoor 35°C(95°F) DB / 23.9°C(75°F) WB
- Heating Temperature : Indoor 21.1°C(70°F) DB / 15.6°C(60°F) WB
Outdoor 8.3°C(47°F) DB / 6.1°C(43°F) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national
code.
3. Due to our policy of innovation some specifications may be changed with-
out notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to
ambient conditions during operation.
* : This temperature (-20 ~ -10°C) can be operated only when Low Ambient
Kit is installed.
Outdoor unit
A4UW36GFA0
[LMU36CHV]
Testing Combination AMNW09GDBL1 * 4EA
Capacity
Cooling
Min.~Rated~Max.
kW
9.37
Min.~Rated~Max.
Btu/h
32,000
Heating
Min.~Rated~Max.
kW
10.6
Min.~Rated~Max.
Btu/h
36,000
Power Input
Cooling Min.~Rated~Max.
kW
2.46
Heating Min.~Rated~Max.
kW
2.54
EER
Btu/Wh
13
SEER / HSPF
-
22.0/10.0
Power Supply
V , Ø , Hz
208/230, 1. 60
Running Current
Cooling Min.~Rated~Max.
A
11
Heating Min.~Rated~Max.
A
11.4
Starting Current
Cooling Max.
A
-
Heating Max.
A
-
Wiring Connections
Power Supply Cable (included Earth)
No. x mm
2
(AWG)
3C x 2.5 (12)
Power and Communication Cable
(included Earth)
Outdoor ~ BD unit No. x mm
2
(AWG)
-
Combination
Sum of Indoor Units Capacity
kBtu/h
48
Number of Indoor Units
EA
4
Number of BD Units
EA
-
Casing Color
-
Warm Gray
Dimensions
W x H x D
mm
950 × 834 × 330
W x H x D
inch
37-13/32 x 32-27/32 x 13
Net Weight
kg (lbs)
62(136.7)
Compressor
Type
-
Twin Rotary
Model
Model x No.
GJT240MA x 1
Motor type
-
BLDC
Motor Output
W x No.
2,020 (at 60Hz) x 1
Refrigerant
Type
-
R410A
Precharged Amount
g (oz)
2,800 (98.8)
Chargeless-Pipe Length
m (ft)
30 (98.4)
Additional Charging Volume
g/m (oz/ft)
20 (0.22)
Control
-
Electronic Expansion Valve
Refrigerant Oil
Type
-
FVC68D
Charged volume
cc x No.
900 x 1
Heat Exchanger (Row x Column x Fins per inch) x No.
-
(2 x 38 x 14) x 1
Fan
Type
-
Propeller
Air Flow Rate
m
3
/min x No. x No.
60 x 1
Fan Motor
Type
-
BLDC
Output
W x No.
124.2 x 1
Sound Pressure Level
Cooling Rated
dB(A)
52
Heating Rated
dB(A)
55
Sound Power Level Cooling Rated
dB(A)
62
Piping Connections
Liquid Outer Dia.
mm(inch) x No.
Ø 6.35 (1/4) x 4
Gas Outer Dia.
mm(inch) x No.
Ø 9.52 (3/8) x 4
Piping Length
Total Piping Max.
m (ft)
75 (246)
Main Piping Max.
m (ft)
-
Total Branch Piping Max.
m (ft)
-
Each Branch Piping Max.
m (ft)
25 (82.0)
Maximum Height Difference
Outdoor Unit ~ Indoor Unit Max.
m (ft)
15 (49.2)
Indoor Unit ~ Indoor Unit Max.
m (ft)
7.5 (24.6)
Operation Range
(Outdoor Temperature)
Cooling Min. ~ Max.
℃ DB (℉ DB)
-18 (0.4)* ~ 48 (118.4)
Heating Min. ~ Max.
℃ WB (℉ WB)
-20 (-4.0) ~ 18 (64.4)
2. List of Functions & Accessory
Note :
O : Applied, × : Not applied
* Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
- 3 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2.2 List of Accessory
2.1 List of Functions
Function
A4UW36GFA0
[LMU36CHV]
Reliability
Defrost / Deicing O
Phase Protection X
Restart Delay(3-minutes) O
Self Diagnosis O
Soft Start O
Test Function X
Convenience
Wiring Error Check O
Night Quiet Mode O
Mode Lock O
Peak Control O
Forced Operation O
CAC Network Function
Central Control(LGAP) O
PDI(Power Distribution Indicator) O
PI485 O
Device
A4UW36GFA0
[LMU36CHV]
Central Controller
Simple Controller X
Function controller X
Function Scheduler X
AC Ez PQCSZ250S0
AC Smart ll PQCSW320A1E
Option Kit (SD card type) PQCSE341A0 / PQCSE342A0
ACP(Advanced Control Platform) PQCPA11A0E / PQCPB11A0E
AC Manager X
PI485 PMNFP14A0 / PMNFP14A1
DO(Digital Output) Kit PQNFP00T0
BNU (Building Network Unit)
LONWORKS Gateway PQNFB16A1
BACnet Gateway PQNFB17B0
Installation
Y branch X X X
Header branch X
Air Guide X
ODU Dry Contact X
Low Ambient Kit O (Logical operation)
- 4 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
3. Piping Diagrams
M
Discharge
Temperature
Thermistor
Suction
Temperature
Thermistor
Inverter
Accumulator
Compressor
Electronic
Expansion
Valve
Condenser Out
Temperature
Thermistor
Inlet Air
Temperature
Thermistor
Outdoor Unit
Ø 6.35
Flare Connection
Ø9.52
Flare Connection
Condensing
Temperature
Thermistor
ROOM A
ROOM A
ROOM B
Field Piping
Liquid(Ø6.35)
Field Piping
Gas(Ø9.52)
: Cooling
: Heating
ROOM B
ROOM C
ROOM D
Main SVC V/V
ROOM C
ROOM D
Main SVC V/V
Pressure
Sensor
- 5 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
4. Wiring Diagrams
CN_PFC_OUT
CN_PFC_IN
CN_4WAY
Dip S/W
CN_MOTOR
CN_EEV 1
CN_COM
CN_EEV 2
CN_EEV 5
CN_EEV 3CN_EEV 4
CN_Power
CN_CENTRAL
CN_LGMV
P_Sensor
CN_TH3 CN_TH2 CN_TH4
CN_HEATER2
- 6 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
5. Exploded View
349480
437211
237202
559010
546810
549610
137213C
447910
435512
554031
435300
554160
550140
W6200
W6640A
649950
548490
268711
430410
137213A
137213B
435301
263230A
263230B
561410
263230C
W6631
437212
552112
552113
552116
W6640B
W49810
552203A
165010
552203B
661400C
661400B
661400A
552200B
661400D
152503
552202
W4986A
W4986B
Location No. Description Sensor Information Housing Color
263230A Temp.Sensor(CN_TH2) Air / Cond Out Pipe Red
263230B Temp.Sensor(CN_TH3) Suction / Discharge Pipe White
263230C Temp.Sensor(CN_TH4) Cond Mid Pipe Orange
165010 Pressure Sensor(P-Sensor(H)) Pressure Sensor Red
P/NO : MFL68280003
FEBRUARY, 2014
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

LG LMU36CHV Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

The LG LMU36CHV multi air conditioner is a powerful and versatile unit that can be used for both cooling and heating purposes. With a cooling capacity of 36,000 Btu/h and a heating capacity of 32,000 Btu/h, it is suitable for use in large rooms or even small apartments. It also features a number of convenient functions, such as a self-diagnosis system, a 3-minute restart delay, and a night quiet mode. Additionally, the LG LMU36CHV is compatible with a variety of optional accessories, such as a central controller and a simple controller, which can be used to further customize its operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI