11
R-370EZ
TABLE OF CONTENTS
Page
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................1
MICROWAVE MEASUREMENT PROCEDURE ...................................................................................................2
FOREWORD AND WARNING...............................................................................................................................3
PRODUCT DESCRIPTION....................................................................................................................................4
OVEN SCHEMATIC...............................................................................................................................................4
PARTS LIST ..........................................................................................................................................................5
SERVICE INFORMATION .....................................................................................................................................7
PACKING AND ACCESSORIES .........................................................................................................................10
S9125R370EPZ/
MICROWAVE OVEN
MODEL
R-370EZ
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Rectifier
Assembly, High Voltage Harness etc..)
SHARP CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
SUPPLEMENTAL SERVICE MANUAL
This is a supplemental Service Manual for Model R-370EZ. This model is quite similar to base
model R-370EK. Use this supplemental manual together with the Base Model Service Manual
(Refer No. is S4112R370EPS/) for complete operation, service information, etc..
V
e
v
e
r
a
g
e
Popcorn
Rice
C
o
m
p
u
D
e
f
r
o
s
t
K
i
t
c
h
e
n
T
im
e
r
Clock
Frozen
E
n
t
r
e
e
Fish
Seafood
C
h
ic
k
e
n
Breast
R
e
h
e
a
t
S
e
n
s
o
r
B
a
k
e
d
P
o
t
a
t
o
e
s
G
r
o
u
n
d
M
e
a
t
F
r
e
s
h
V
e
g
e
t
a
b
le
s
F
r
o
z
e
n
V
e
g
e
t
a
b
le
s
R
o
l
l
s
&
M
u
f
f
i
n
s
C
u
s
t
o
m
H
e
l
p
P
o
w
e
r
L
e
v
e
l
S
T
O
P
C
l
e
a
r
M
i
n
u
t
e
P
lu
s
S
T
A
R
T
12345
67890
12
R-370EZ
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described
in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave
Measurement Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS
CORPORATION immediately @1-800-237-4277.
If the unit operates with the door open, service person should 1) tell the user not to operate the oven
and 2) contact SHARP ELECTRONICS CORPORATION and The Food and Drug Administration's
Center for Devices and Radiological Health immediately.
Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit
found with emissions in excess of 4mW/cm
2
. The owner of the unit should be instructed not to use
the unit until the oven has been brought into compliance.
1
R-370EZ
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts
may result in a severe, possibly
fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem-
bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconnect the power supply cord , and then
remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
WARNING:RISK OF ELECTRIC SHOCK.
DISCHARGE THE HIGH-VOLTAGE
CAPACITOR BEFORE SERVICING.
The high-voltage capacitor remains charged about 60
seconds after the oven has been switched off. Wait for 60
seconds and then short-circuit the connection of the high-
voltage capacitor (that is the connecting lead of the high-
voltage rectifier) against the chassis with the use of an
insulated screwdriver.
Whenever troubleshooting is performed the power supply
must be disconnected. It may, in some cases, be necessary
to connect the power supply after the outer case has been
removed, in this event,
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power
transformer.
5. Ensure that the leads remain isolated from other
components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power
transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is
installed.
7. Run the oven and check all functions.
After repairing
1. Reconnect all leads removed from components during
testing.
2. Reinstall the outer case (cabinet).
3. Reconnect the power supply cord after the outer case is
installed.
4. Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the
presence of microwave energy within a cavity, place a cup
of cold water on the oven turntable, close the door and set
the power to HIGH and set the microwave timer for two (2)
minutes. When the two minutes has elapsed (timer at zero)
carefully check that the water is now hot. If the water
remains cold, carry out Before Servicing procedure and re-
examine the connections to the component being tested.
When all service work is completed and the oven is fully
assembled, the microwave power output should be checked
and a microwave leakage test should be carried out.
Don't Touch !
Danger High Voltage
2
R-370EZ
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
should not exceed 1mW/cm
2
at any point 5cm or more from the external surface of the oven, measured prior to acquisition
by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm
2
at any point 5cm or more from the external
surface of the oven.
2) Safety interlock switches:
Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement
as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm
2
at
any point 5cm or more from the external surface of the oven.
B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard
for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5˚C (68˚F) in the center of the oven cavity.
The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and
made of an electrically nonconductive material such as glass or plastic.
The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage
is measured accurately.
4) Set the cooking control on Full Power Cooking Mode
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed,
replace it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the
meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal
has been breached (eg., around the switches, indicator, and vents).
While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed
latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm
2
.
NOTE: After servicing, record data on service invoice and microwave leakage report.
3
R-370EZ
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
MICROWAVE OVEN
R-370EZ
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service
Information for the SHARP MICROWAVE OVEN, R-370EZ.
The model R-370EZ is quite similar to base model R-370EK (Refer No. is S4112R370EPS/).
It is recommended that service personnel carefully study the entire text of this manual and the base model's manual so that
they will be qualified to render satisfactory customer service.
Check the interlock switches and the door seal carefully. Special attention should be given to avoid electrical shock and
microwave radiation hazard.
WARNING
Never operate the oven until the following points are ensured.
(A) The door is tightly closed.
(B) The door brackets and hinges are not defective.
(C) The door packing is not damaged.
(D) The door is not deformed or warped.
(E) There is no other visible damage with the oven.
Servicing and repair work must be carried out only by trained service personnel.
DANGER
Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing.
Service personnel - Do not contact the following parts while the appliance is energized;
High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage
Harness;
If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
All the parts marked “*” on parts list are used at voltages more than 250V.
Removal of the outer wrap gives access to voltage above 250V.
All the parts marked “” on parts list may cause undue microwave exposure, by themselves, or when they are damaged,
loosened or removed.
4
R-370EZ
ITEM DESCRIPTION
Power Requirements 120 Volts / 13.5 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output 1000 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions Width 17-1/4"
Height 13-3/8"
Depth 18-3/8"
Cooking Cavity Dimensions Width 13-3/4"
Height 7-1/4"
1.4 Cubic Feet Depth 16-1/2"
Control Complement Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
HIGH................................................Full power throughout the cooking time
P-90 .................................................................... approx. 90% of Full Power
P-80 .................................................................... approx. 80% of Full Power
P-70 .................................................................... approx. 70% of Full Power
P-60 .................................................................... approx. 60% of Full Power
P-50 .................................................................... approx. 50% of Full Power
P-40 .................................................................... approx. 40% of Full Power
P-30 .................................................................... approx. 30% of Full Power
P-20 .................................................................... approx. 20% of Full Power
P-10 .................................................................... approx. 10% of Full Power
P-0 .................................................... No power throughout the cooking time
SENSOR COOKING pads , INSTANT ACTION pads
COMPU DEFROST pads, Number selection pads
CUSTOM HELP PAD, POWER LEVEL pad,
KITCHEN TIMER/CLOCK pad
STOP/CLEAR pad, MINUTE PLUS /START pad
Oven Cavity Light Yes
Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED
2. CLOCK APPEARS ON DISPLAY
NOTE: " " indicates components with potential above 250V.
120V AC
60 Hz
OVEN
LAMP
AH SENSOR
OVEN LAMP
RELAY
TURNTABLE
MOTOR
FAN
MOTOR
POWER
TRANSFORMER
MONITOR
SWITCH
RECTIFIER
MAGNETRON
PRIMARY
INTERLOCK
SWITCH
TTM
OL
FM
FAN
MOTOR
FM
MONITOR
FUSE 20A
N.O.
N.O.
COM.
COM.
DOOR
SENSING
SWITCH
(RY1)
(RY2)
CONTROL UNIT
SECONDARY
INTERLOCK
RELAY
OVEN THERMAL
CUT-OUT
MG. THERMAL CUT-OUT
GRN
B2 B1
CAPACITOR
0.94µF
AC 2200V
F1
F3
F2
5
R-370EZ
REF. NO. PART NO. DESCRIPTION Q'TY CODE
*
*
*
*
*
*
ELECTRIC PARTS
1- 1 FACCDA085WREZ Power supply cord 1 AQ
1- 2 QFSHDA024WRZZ Fuse holder 1 AG
1- 3 QSW-MA137WRE0 Primary interlock switch / door sensing switch 2 AH
1- 4 FFS-BA023WRK0
Monitor fuse 20A and monitor switch (AM51620C53Y1) assembly
1AS
1- 5 RTHM-A116WRE0 Thermal cut-out 125 deg. C (MG) 1 AK
1- 6 FH-DZA100WRKZ High voltage rectifier assembly 1 AQ
1- 7 RC-QZA211WRE0 High voltage capacitor 1 AV
1- 7 RC-QZA286WRZZ High voltage capacitor (Interchangeable) 1 AV
1- 8 RMOTEA400WRZZ Fan motor 2 AX
1- 9 RTRN-A638WRZZ Power transformer 1 BP
1-10 RV-MZA288WRE0 Magnetron 1 BK
1-10 RV-MZA308WRZZ Magnetron (Interchangeable) 1 BL
1-11 RLMPTA082WRZZ Oven lamp 1 AL
1-12 RMOTDA186WRE0 Turntable motor 1 AQ
1-12 RMOTDA211WRE0 Turntable motor (Interchangeable) 1 AS
1-13 RTHM-A123WRZZ Thermal cut-out 125 deg. C (OVEN) 1 AK
1-14 FDTCTA212WRKZ AH sensor 1 AX
CABINET PARTS
2- 1 GDAI-A335WRWZ Base plate 1 AW
2- 2 GLEGPA087WRFZ Front leg 1 AK
2- 3 GLEGPA081WRFZ Leg 1 AC
2- 4 GCABUA807WRPZ Outer case cabinet 1 BD
2- 5 GCOVAA291WRFZ Harness cover 1 AH
POWER UNIT PARTS
3- 1 DPWBFC179WRUZ Power unit 1 BC
3- 1A QCNCMA431DRE0 2-pin connector (CN-B) 1 AC
3- 1B QCNCMA470DRZZ 9-pin connector (CN-C) 1 AF
3- 1C QCNCMA237DRE0 3-pin connector (CN-F) 1 AD
C1 RC-KZA087DRE0 Capacitor 0.1 uF 50V 1 AA
C2 VCEAB31VW108M Capacitor 1000 uF 35V 1 AF
C3 VCEAB31VW106M Capacitor 10 uF 35V 1 AA
C21 VCEAB31VW106M Capacitor 10 uF 35V 1 AA
C50-51 RC-KZA087DRE0 Capacitor 0.1 uF 50V 2 AA
D1-4 RH-DZA006PRE0 Diode (1N4002) 4 AD
D20-22 VHD1SS270A/-1 Diode (1SS270A) 3 AA
D40 VHD1SS270A/-1 Diode (1SS270A) 1 AA
IC2 VHIBA4558//-6 IC (BA4558) 1 AK
Q1 VS2SB1238//-3 Transistor (2SB1238) 1 AA
Q21 VSDTD143ES/-3 Transistor (DTD143ES) 1 AC
Q22 VSDTA143ES/1B Transistor (DTA143ES) 1 AA
R1 VRD-B12EF242J Resistor 2.4k ohm 1/4W 1 AA
R2 VRS-B13AA331J Resistor 330 ohm 1W 1 AA
R4 VRD-B12EF332J Resistor 3.3k ohm 1/4W 1 AA
R50 VRS-B13AA331J Resistor 330 ohm 1W 1 AA
R51 RR-DZA285DRZZ Resistor 3.32k ohm ±0.5% 1/4W 1 AC
R52 RR-DZA286DRZZ Resistor 3.57k ohm ±0.5% 1/4W 1 AC
R53 VRN-B12EK182F Resistor 1.8k ohm ±1.0% 1/4W 1 AA
R54 VRN-B12EK364F Resistor 360k ohm ±1.0% 1/4W 1 AA
RY1 RRLY-A076DRE0 Relay (OMIF-S-124LM) 1 AK
RY2 RRLY-A113DRE0 Relay (DU24D1-1P(M)-R) 1 AM
SP1 RALM-A014DRE0 Buzzer (PKM22EPT) 1 AG
T1 RTRNPA111DRE0 Transformer 1 AP
VRS1 RH-VZA032DRE0 Varistor (10G471K) 1 AE
ZD1 VHEHZ161///-1 Zener diode (HZ16-1) 1 AA
OVEN PARTS
4- 1 PHOK-A118WRFZ Latch hook 1 AH
4- 2 LBNDKA099WRW0 Capacitor holder 1 AD
4- 3 PDUC-A772WRWZ Fan duct 1 AN
4- 4 NFANJA047WREZ Fan blade 2 AL
4- 5 PPACGA084WRF0 TTM packing 1 AE
4- 6 ************* Oven cavity (Not a replaceable part) 1--
4- 7 GCOVHA423WRFZ Choke cover 1 AL
4- 8 LANGQA531WRWZ Lamp angle 1 AP
4- 9 PCOVPA361WREZ Waveguide cover 1 AD
4-10 LANG-A084WRFZ Separate angle A 1 AG
PARTS LIST
Note: The parts marked “” may cause undue microwave exposure.
The parts marked “*” are used in voltage more than 250V.
6
R-370EZ
REF. NO. PART NO. DESCRIPTION Q'TY CODE
4-11 LANG-A085WRFZ Separate angle B 1 AG
4-12 LANG-A086WRFZ Separate angle C 1 AG
4-13 PCLI-A002WREZ PC support clip 2 AD
4-14 FANG-A013WRYZ Magnetron duct assembly 1 AP
4-15 LANGFA200WRPZ Support angle 1 AD
4-16 NCPL-A053WRFZ Coupling 1 AE
4-17 PCUSUA571WRPZ Cushion 1 AH
4-18 PDUC-A775WRTZ Exhaust duct 1 AP
4-19 PPACGA181WREZ Cushion 1 AH
4-20 PPACGA182WREZ Cushion 1 AC
4-21 PCUSUA573WRPZ Cushion 1 AC
4-22 PCUSUA313WRP0 Cushion 1 AF
4-23 PCUSUA578WRPZ Cushion 1 AG
4-24 PCUSUA577WRPZ Cushion 1 AC
4-25 PCUSGA561WREZ Cushion 1 AC
4-26 PCUSUA583WRPZ Cushion 1 AG
4-27 PCUSUA375WRP0 Cushion 1 AH
4-28 PCUSGA560WREZ Cushion 2 AB
4-29 PCUSGA564WREZ Cushion 1 AH
4-30 PCUSGA563WREZ Cushion 1 AH
DOOR PARTS
5- 1 FDORFA347WRTZ Door panel 1 AX
5- 2 PSHEPA775WREZ Sealer film 1 AH
5- 3 FWAKPA352WRKZ Door frame assembly 1 BE
5-3-1 FUNTKB060WREZ Key unit 1 AV
5-3-2 HPNL-A762WRRZ Door screen 1 AU
5- 4 LSTPPA193WRFZ Latch head 1 AE
5- 5 MSPRTA202WREZ Latch spring 1 AD
5- 6 DPWBFC176WRKZ CPU unit 1 BD
5- 7 LHLD-A236WRFZ LCD holder 1 AC
5- 8 PSHEPA786WREZ LED sheet 1 BB
5- 9 FW-VZA272DREZ 9-pin wire harness 1 AL
5-10 PCOVPA372WRWZ PWB cover 1 AF
5-11 PCUSUA567WRPZ Cushion 1 AE
5-12 XEBSD38P08000 Screw : 3.8mm x 8mm 4 AA
5-13 XEPSD30P08XS0 Screw : 3mm x 8mm 3 AA
5-14 LHLD-A237WRFZ Light guide 1 AL
5-15 PCUSUA461WRP0 Cushion 1 AB
MISCELLANEOUS
6- 1 FROLPA079WRK0 Turntable support 1 AP
6- 2 NTNT-A079WRF0 Turntable tray 1 AR
6- 2 NTNT-A084WRE0 Turntable tray (Interchangeable) 1 AQ
6- 3 FW-VZB827WREZ Main wire harness 1 AW
6- 4 QW-QZA242WRZZ High voltage wire B 1 AF
6- 5 TCAUAA265WRRZ DHHS caution label 1 AC
6- 6 TCAUAA254WRR0 Monitor caution label 1 AC
6- 7 TINSEA914WRRZ Instruction book 1 AM
6- 8 FW-VZB828WREZ Switch harness 1 AK
6- 9 FW-VZB802WREZ T.T. motor harness 1 AF
SCREWS,NUTS AND WASHERS
7- 1 XHPSD40P08K00 Screw : 4mm x 8mm 8 AA
7- 2 XHPSD40P08000 Screw : 4mm x 8mm 1 AA
7- 3 XOTSD40P08000 Screw : 4mm x 8mm 9 AA
7- 4 LX-CZA073WRE0 Special screw 1 AC
7- 5 XOTSD40P12000 Screw : 4mm x 12mm 2 AA
7- 6 XHPSD30P08XS0 Screw : 3mm x 8mm 2 AB
7- 7 XHTSD40P08RV0 Screw : 4mm x 8mm 9 AA
7- 8 LX-CZA070WRE0 Special screw (Torx tamper proof screw) 2 AC
7- 9 LX-CZ0052WRE0 Special screw 2 AA
7-10 XHPSD30P06000 Screw : 3mm x 6mm 1 AA
7-11 XHTSD40P08000 Screw : 4mm x 8mm 4 AA
7-12 XHTSD40P12RV0 Screw : 4mm x 12mm 1 AA
7-13 XOTSD40P12RV0 Screw : 4mm x 12mm 4 AA
7-14 XOTSF40P08000 Screw : 4mm x 8mm 2 AA
7-15 LX-EZA060WREZ Special screw 4 AA
7-16 XOTSD40P12000 Screw : 4mm x 12mm 1 AA
7-17 XHBWW30P08000 Screw : 3mm x 8mm 2 AB
7
R-370EZ
HOW TO ORDER REPLACEMENT PARTS
To have your order filled promptly and correctly, please furnish the following information.
1. MODEL NUMBER
2. REF. NO.
3. PART NO.
4. DESCRIPTION
Order Parts from the authorized SHARP parts Distributor for your area.
Defective parts requiring return should be returned as indicated in the Service Policy.
POWER SUPPLY
CORD 120V 60Hz
COM.
COM.
N.O.
N.O.
FAN
MOTOR
POWER
TRANSFORMER
NOTE:
The neutral (WHT) wire must be
connected to the terminal with "N"
mark on the power supply cord.
GRY
BLK
ORG
from Aug. 2001 Prod.
GRY
RED
RED
BLK
RED
BLK
BLK
BLK
MONITOR
FUSE
&
HOLDER
GRY
WHT
RED
WHT
WHT
WHT
RY2
RY1
SECONDARY
INTERLOCK
RELAY
T1
POWER UNIT
H
N
NOTE:
The grounding conductor of
the power supply cord has
been grounded by power
supply cord fixing screw.
The screw must always be
kept tight.
RED
ORG
from Aug. 2001 Prod.
SERVICE INFORMATION
The color of lead wire has been changed as follow.
MODEL EFFECTIVE FROM
R-370EK Serial No. from 26937
R-370ES Serial No. from 04928
R-370EZ 1 st. lot production
8
R-370EZ
6
45
1
2
3
6
45
1
2
3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
7-4
1-14
7-17
7-7
7-7
7-3
7-7
4-2
1-7
2-3
7-16
1-6
4-10
7-6
7-3
1-10
7-7
7-7
1-12
7-1
4-16
7-5
4-20
4-12
4-13
x2
1-4
4-22
7-1
7-9
7-11
7-11
7-13
7-15
7-10
1-9
4-44-11
7-3
7-2
1-8
1-8
4-1
1-1
4-25
4-6
4-24
4-28
4-28
4-17
4-18
6-6
7-14
7-14
7-12
7-3
7-8
4-19
4-21
4-29
7-7
1-5
1-4
1-3
4-5
4-30
1-2
1-3
3-1
4-14
4-8
1-11
4-15
7-5
2-5
4-4
7-1
2-1
7-3
2-2
4-9
6-1
6-2
7-13
4-3
7-1
x2
7-1
x2
4-23
1-13
4-26
6-5
4-27
2-4
7-11
OVEN AND CABINET PARTS
9
R-370EZ
6
45
1
2
3
6
45
1
2
3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Actual wire harness may be different from illustration.
(CAPACITOR)
5-13
5-11
5-12
5-12
5-12
5-10
5-9
5-6
5-13
4-7
5-7
5-1
5-14
5-6
6-3
6-4
5-2
5-8
5-4
5-15
5-12
5-3-2
5-3-1
5-3
6-8
6-9
5-5
MISCELLANEOUS
DOOR PARTS
10
R-370EZ
2001 SHARP CORP. (8S1.700E) Printed in U.S.A
COPYRIGHT © 2001 BY SHARP CORPORATION
ALL RIGHTS RESERVED.
No part of this publication may be reproduced,
stored in retrieval systems, or transmitted in any
form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior
written permission of the publisher.
PACKING AND ACCESSORIES
DOOR PROTECTION SHEET
SPADPA204WRE0
TOP PAD ASSEMBLY
FPADBA451WRKZ
WRAP COVER
SSAKHA072WREZ
Not replaceable items.
PACKING CASE
FPAK-A412WRKZ
BOTTOM PAD ASSEMBLY
FPADBA453WRKZ
6- 2 TURNTABLE TRAY
6-7 INSTRUCTION BOOK
& PRINTING MATTER
6- 1 TURNTABLE SUPPORT
TRAY PAD
SPADFA499WREZ
INTO THE
OVEN CAVITY
CABINET COVER
SPAKHA018WREZ
FOAM SHEET
SPAKHA017WREZ
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Sharp 36-250 User manual

Category
Microwaves
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI